Project Name:
Project#:
Name Initials Date Completed
Designer
Checker
Piping Lead
Designer
Designer
Designer
Checker
Checker
Checker
Checklist Items
1 As the project proceeds through each model review each model must be
updated to incorporate any changes from the model review log.
2 Confirm the current civil model is loaded and updated to latest design
comments.
3 Confirm the current electrical model is loaded and updated to latest design
comments.
4 Confirm all stress comments are incorporated as per the stress engineer's
comments. Does stress markup match current design or has it changed?
Notify stress of any major changes.
5 Confirm the current equipment models are loaded and updated to latest
vendor data.
6 Before isometrics are run, the designer will check his/her P&ID's against the
Contract Master stick file. He/she will then yellow off NWD model against
the updated P&IDs to ensure it is accurate and all items on the P&ID are
included in the model.
7 Review model to plot plan.
8 Confirm clearance between equipment and buildings for maintenance
vehicles.
9 Consider crane access for equipment lifts during construction and
maintenance requirements such as tube removals etc.
10 Confirm accessibility sufficient around equipment for adequate operability of
instruments and valving etc.
11 Tank farm – are cleanouts close to each other to minimize contamination or
damage? Is there adequate truck access for both truck out and maintenance?
Is there room for heater withdrawals? Tank elevation vs pump elevation?
12 Check access, egress, headroom, maintenance areas, stiles & platform
accessibility.
13 All walkways, platforms, man accessible areas are clear from potential head
collisions and knee knockers.
14 Piping is run in an efficient manner, common pipe supports, platforms, etc.
15 As each line is being reviewed all inline instruments and instrument
connections are to be checked against the vendor data supplied by the
instrument group.
16 Adequate up and down stream straight pipe lengths for meter runs, tap
orientations.
LL-CHK-0005
Rev_2
Energy & Process Page 1 of 2 Rev Date: 2021-01-15
Piping Model Finalization Checklist
Yes No N/A
Designer
Designer
Designer
Checker
Checker
Checker
Checklist Items
NOTE: Once a model/drawing is in checking it should be considered frozen and no further modifications done until
checking complete.
LL-CHK-0005
Rev_2