Substation Configuration Diagram M1

This document provides a diagram and overview of the connections between various components in an electrical substation automation system. It shows connections between equipment like RTUs, HMIs, control panels, and protection panels. These components are connected through different types of lines like electrical lines using TCP/IP and MODBUS protocols, and fiber optic lines using the IEC 61850 protocol. The document is intended to illustrate the proposed functionalities but notes that actual installed equipment may vary in appearance.

Uploaded by

dimasrimantikto
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
660 views1 page

Substation Configuration Diagram M1

This document provides a diagram and overview of the connections between various components in an electrical substation automation system. It shows connections between equipment like RTUs, HMIs, control panels, and protection panels. These components are connected through different types of lines like electrical lines using TCP/IP and MODBUS protocols, and fiber optic lines using the IEC 61850 protocol. The document is intended to illustrate the proposed functionalities but notes that actual installed equipment may vary in appearance.

Uploaded by

dimasrimantikto
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

LEGEND :

Blue lines Electrical line connection (TCP/IP)


Red lines Fiber optic LAN connection (IEC61850)
Black lines Equipment connection non LAN
Green lines Electrical line connection (MODBUS)

Disclaimer :The shown product pictures are mainly for


illustration of the proposed functionalities. The supplied
goods might look different from the illustrations shown
.

GIS CENTRAL
RELAY ROOM CONTROL ROOM
SCADA

FO Patch FO Patch HMI


HMI RTU/ Panel Panel
Gateway To DCS IEC OCYR8913 16
61850 fibres MM Plant DCS
GPS
Common System
System
Clock ABB, RTU560

0AYG01
RTU Panel CAB
PROTECTION &
IEC 61850 AUTOMATION ROOM
Modbus

ETH Switch ABB, AFS670 ETH Switch ABB, AFS670


Patch Patch
terminal terminal
Armoured fiber
optic cable

=E03+CC1, 0AWE03 =E01+CC1, 0AWE01 =E02+CP1, 0ARE01 =E05+CP1, 1CHB05 =E03+CP1, 0CHB03
=E05+CC1, 0AWE05
=E04+CC1, 0AWE04 =E07+CC1, 0AWE07 =E07+CP1, 0ARE07 =E06+CP1, 2CHB06 =E04+CP1, 0CHB04
=E06+CC1. 0AWE06 =E02+CC1, 0AWE02 =E00+CP1, 0ARE02
Control Panel Control Panel Prot. Panel Prot. Panel Prot. Panel
Control Panel Control Panel Prot. Panel

87L,
79, 25
87T, REF 87T, REF
27, 59 87BB

V/V Sync f/f


Supplied by
PTCL
A, V, A, V, A, V, A, V, ABB, RET670 ABB, RET670
W,Var, W,Var, W,Var, Alstom, P543 ABB, REB670
W,Var,
f, PF f, PF f, PF f, PF
87B, REF
Patch
terminal

ABB, REB670
ABB, RET670
50/51, AVR
50N/51N
50/51, 50/51, 50/51, 50/51, Tariff (UAT)
50N/51N 50N/51N 50N/51N 50N/51N Meter ABB, REB670 ABB, REF615 ABB, REU615
50BF, 25 50BF 50BF, 25 50BF, 25 Schneider,
ION
ABB, REF615 ABB, REF615 ABB, REF615 ABB, REF615
FO to
2 x 150kV OHTL 150kV Bus Coupler remote 2 x 150kV OHTL 150kV Busbars 2 x 150/15kV GSUT 2 x 150/6.3kV SST
2 x 150/15kV GSUT 2 x 150/6.3kV SST relay
1BAT10 & 2BAT10 0AET10 & 0AET20 OHTL1 & OHTL2 COUPLER OHTL1 & OHTL2 BUSBAR PROT 1BAT10 & 2BAT10 0AET10 & 0AET20

Title Project
Customer GIS BABELAN 150KV
150 KV GIS BABELAN
M1
M0
Rev.
As commented
For approval
Revision note
24.03.16
07.10.14
Date
UA
UA
Name
PT Cikarang Listrindo ABB SUBSTATION CONFIGURATION DIAGRAM
Dwg. No.

BPS-0AE-28037 Sheet
01
N.Sheet
-

87T, REF
50/51,
50N/51N
50BF, 25
2 x 150/15kV GSUT
1BAT10 & 2BAT10
=E05+CC1, 0AWE05
=E06+CC1. 0AWE06
Control Panel
150 KV GIS