Professional Documents
Culture Documents
Analyzer
Atlas Copco GA 75 VSD vs. IR N 75
Analysis for capacity and specific power
Comparison Conclusions:
• At full load capacity and energy consumption of both machines are very similar. For almost the same
capacity the N75 has a significant lower energy consumption.
• The separate inverter for the fan on the N75 enables the compressor
• to operate at low and constant specific power at any load.
• to operate quieter than any other compressor by slowing down or turning of the fan.
• considered fan energy consumption is at its “worst case”: the fan at normal conditions runs less
often, consuming less energy than stated.
• The specific power of the GA75 starts to be good from 50% load, but is fluctuating, whereas the N75 is
constantly low.
• This difference, and with it the saved energy, is extreme in the lower speed range where the GA75
needs to serve at lower speed because it can’t cycle as often as a Nirvana. This shows that the Nirvana
is a true VSD Compressor.
Ingersoll-Rand European Sales Ltd Strictly Confidential - Do not copy For internal use only