30 - Reservoiur Outlet

ABB AquaMaster4 R DN250 AC Powered Estimated Accuracy ABB AquaMaster4 R DN250 AC Powered Estimated Accuracy
(Log Scales) 0 to 0.5 m/s Flow Velocity
5 ‐ 5

4  ‐

4.5
3  ‐

4
2  ‐

3.5

3
1
Accuracy +/-%

Accuracy +/-%
2.5

0.4  ‐
1.5

1
0.2  ‐

0.5

0
0.1 0 0.1 0.2 0.3 0.4 0.5
0.001 0.01 0.1 1 10
Velocity (m/s) Velocity m/s
0.177 1.767 17.67 176.71 1767.1 0 17.67 35.34 53.01 70.7 88.4
Flow Rate (m³/hr) Flow Rate (m³/hr)

Estimated Accuracy Class 1 (AC 0.2%) Specified Point:


Estimated Accuracy Class 2 (AC 0.4%) Velocity 0.532 m/s Class 1 Accuracy ± 0.20 %
Flow Rate 94 m³/hr Class 2 Accuracy ± 0.40 %
30 - Reservoiur Outlet

ABB AquaMaster4 R DN250 AC Powered Estimated Accuracy ABB AquaMaster4 R DN250 AC Powered Estimated Accuracy
(Log Scales) 0 to 0.5 m/s Flow Velocity
5 ‐ 5

4  ‐

4.5
3  ‐

4
2  ‐

3.5

3
1
Accuracy +/-%

Accuracy +/-%
2.5

0.4  ‐
1.5

1
0.2  ‐

0.5

0
0.1 0 0.1 0.2 0.3 0.4 0.5
0.001 0.01 0.1 1 10
Velocity (m/s) Velocity m/s
0.177 1.767 17.67 176.71 1767.1 0 17.67 35.34 53.01 70.7 88.4
Flow Rate (m³/hr) Flow Rate (m³/hr)

Estimated Accuracy Class 1 (AC 0.2%) Specified Point:


Estimated Accuracy Class 2 (AC 0.4%) Velocity 1.856 m/s Class 1 Accuracy ± 0.20 %
Flow Rate 328 m³/hr Class 2 Accuracy ± 0.40 %