Test Report

Page 1 of 13
Report No.: ES140416001RE/02

Client : SHENZHEN ZTE MOBILE TELECOM CO., LTD.


Address : 7/F, A TOWER, Hans Innovation Mansion, North Ring Rd, No. 9018, High-Tech Park
Nanshan District, Shenzhen, China.

Sample Name : Mobile Phone

Sample Received Date : Apr.16, 2014


Sample Tested Date : Apr.16, 2014~ Apr.24, 2014

Reference Standard : ISTA 3A:2008


Test Item : As Below Table
Test Sequence Test Item
1 Temperature and Humidity Test
2 Packaged Drop Test
3 Random Vibration Test (0.53Grms)
4 Random Vibration Test (0.46Grms)

Test Results: Please refer to page 3~7.

Inspected By: Date:

Reviewed By: Date:

Approved By: Date:

Report No.:ES140416001RE/02
Test Report
Page 2 of 13
Tested Sample:

Sample No. Sample Name Model/Type Quantity


ES140416001RE-001 9B0410210056 1pc
ES140416001RE-002 Mobile Phone 9B0410210037 1pc
ES140416001RE-003 9B0410210041 1pc

Test Sequence:

Test Sequence Test Item Sample No.

1 Temperature and Humidity Test 001~003

2 Packaged Drop Test 001~003

3 Random Vibration Test (0.53Grms) 001~003

4 Random Vibration Test (0.46Grms) 001~003

Definition of Side:

Report No.:ES140416001RE/02
Test Report
Page 3 of 13
Test Item 1: Temperature and Humidity Test

(1) Test Equipment:

Name Model Serial No. Valid Date to

Temperature & Humidity


ESL-04KA ER-059 May 27, 2014
Test Chamber

(2) Environmental Conditions:

Temperature: 18℃ Humidity: 60%RH

(3) Test Conditions:

---Temperature: 38℃

---Humidity: 85%RH

---Test duration: 72hours

(4) Acceptance Criteria: After test, check if there is any damage on the appearance of the sample.

(5) Test Results: After test, there was no visible damage on the appearance of the samples.

Other characteristics should be evaluated by the client.

(6) Test Photos Refer to Appendix

Report No.:ES140416001RE/02
Test Report
Page 4 of 13
Test Item 2: Random Vibration Test(0.53Grms)
(1) Test Equipment:

Name Model Serial No. Valid Date to

Vibration Test System EM-3500F2K-75N600 ER-018 Nov. 13, 2014

(2) Environmental Conditions:

Temperature: 22℃ Humidity: 61%RH

(3) Test Conditions:

Frequency(Hz) PSD Level (g2/Hz) Acceleration (Grms)

1 0.0007

3 0.02

5 0.02

7 0.001

12 0.001

15 0.004
0.53
24 0.004

28 0.001

36 0.001

42 0.003

75 0.003

200 0.000004

--- Test face: face 1 and face 2

--- Test time: 30 minutes for each face

--- Test load: 36 kg

(4) Acceptance Criteria: After test, check if there is any damage on the appearance of the sample.

(5) Test Results: After test, there was no visible damage on the appearance of the sample.

Other characteristics should be evaluated by the client.

(6) Test Photos and Curve Refer to Appendix

Report No.:ES140416001RE/02
Test Report
Page 5 of 13
Test Item 3: Random Vibration Test(0.46Grms)

(1) Test Equipment:

Name Model Serial No. Valid Date to

Vibration Test System EM-3500F2K-75N600 ER-018 Nov. 13, 2014

(2) Environmental Conditions:

Temperature: 22℃ Humidity: 60%RH

(3) Test Conditions:

Frequency(Hz) PSD Level (g2/Hz) Acceleration (Grms)

1 0.001

3 0.035

4 0.035

7 0.0003

13 0.0003

15 0.001
0.46
24 0.001

29 0.0001

50 0.0001

70 0.002

100 0.002

200 0.00005

--- Test face: face 3

--- Test time: 30 minutes

(4) Acceptance Criteria: After test, check if there is any damage on the appearance of the sample.

(5) Test Results: After test, there was no visible damage on the appearance of the sample.

Other characteristics should be evaluated by the client.


(6) Test Photos and Curve Refer to Appendix

Report No.:ES140416001RE/02
Test Report
Page 6 of 13
Test Item 4: Packaged Drop Test (First)

(1) Test Equipment:

Name Model Serial No. Valid Date to

Free Fall Tester SY41-300 ER-020 May 27, 2014

(2) Environmental Conditions:

Temperature: 27℃ Humidity: 62%RH

(3) Test Conditions:

Drop Sequence Drop Height (mm) Orientation

1 Edge 3-4

2 Edge 3-6

3 Edge 4-6

4 460 Corner 3-4-6

5 Corner 2-3-5

6 Edge 2-3

7 Edge 1-2

8 910
Face 3
9 460

(4) Acceptance Criteria: After test, check if there is any damage on the appearance of the sample.

(5) Test Results: After test, there was no visible damage on the appearance of the sample.

Other characteristics should be evaluated by the client.

(6) Test Photos Refer to Appendix

Report No.:ES140416001RE/02
Test Report
Page 7 of 13
Test Item 4: Packaged Drop Test (Second)

(1) Test Equipment:

Name Model Serial No. Valid Date to

Free Fall Tester SY41-300 ER-020 May 27, 2014

(2) Environmental Conditions:

Temperature: 24℃ Humidity: 62%RH

(3) Test Conditions:

Drop Sequence Drop Height (mm) Orientation

1 Face 4

2 Face 1

3 Face 2

4 610 Face 3

5 Face 1

6 Face 2

7 Face 4

(4) Acceptance Criteria: After test, check if there is any damage on the appearance of the sample.

(5) Test Results: After test, there was no visible damage on the appearance of the sample.

Other characteristics should be evaluated by the client.

(6) Test Photos Refer to Appendix

Report No.:ES140416001RE/02
Test Report
Page 8 of 13
Appendix: Test Photos

Before the test Sample-001 Before the test Sample-0012

Before the test Sample-003 In the test-Temperature and Humidity Test

In the test- Random Vibration Test (face 1) In the test- Random Vibration Test (face 2)

Report No.:ES140416001RE/02
Test Report
Page 9 of 13
Appendix: Test Photos

In the test- Random Vibration Test (face 3) In the test-Packaged Drop Test (Sample-001)

In the test-Packaged Drop Test (Sample-002) In the test-Packaged Drop Test (Sample-003)

After the test Sample-001 After the test Sample-002

Report No.:ES140416001RE/02
Test Report
Page 10 of 13
Appendix: Test Photos

The Blank

After the test Sample-003

Report No.:ES140416001RE/02
Test Report
Page 11 of 13
Appendix: Random Vibration Test Curve (0.53Grms)

Face 1

Report No.:ES140416001RE/02
Test Report
Page 12 of 13
Appendix: Random Vibration Test Curve (0.53Grms)

Face 2

Report No.:ES140416001RE/02
Test Report
Page 13 of 13
Appendix: Random Vibration Test Curve (0.46Grms)

Face 3

*** End of report ***