You are on page 1of 2

TEST REPORT OF COLD ROLLED MS STRIP

1. Information:

Scope of Report Quality Check

Requester Quality Control Department (Refrigerator)

Supplier Name Steel Line Co. Ltd.

Model 0.5X24.9mm Cold Rolled MS Strip

Date of Sampling 10.12.2019

GRN number N/A

Lot quatity 94 COILS

B/E C-1807253

PO No. 4084983

LAB Name & address Electrical & Mechanical IQC Lab.

Test Location IQC Lab (Shed Number-6)

Test method ASTM E 8M, E18 & E 1507

Test date 11.12.2019

Issued date 12.12.2019

Sampling policy 3 sample based

Measurement uncertainty ± 1.7 µm for Micrometer

Ambient Temp. & Humidy 23 °C & 56 %

Problem Qty 0

Problem(%) 0%

Tools used Micrometer (Serial no.- 63154641)

CY- 6040A4 UTM (Chun Yen), SHR 150 CD Hardness tester (Dongguan) &
Machine used
SPECTROLAB LAVM12

2. Test Status: Accepted

3. Remarks:

Ref. No. DOC Code CRS000008 WALTON HI-TECH INDUSTRIES LTD.

Tested By Checked By Approved By Chandra, Kaliakoir, Gazipur


Department: Quality Control (Refrigerator)
Section: Wire Harness QC, IQC & QC Lab.

Sub section: Metal IQC


COMPOSITION AND MECHANICAL TEST REPORT OF COLD ROLLED MS STRIP

Table 1: Chemical Composition Analysis

Chemical Composotion (wt. %)


Sl No. Sample
C Si Mn P S Fe

Tested 0.0033 0.0064 0.04 0.007 0.0001 99.8


MS STRIP
1
0.5x24.9 mm
Standard ≤ 0.005 0.05 Max 0.15 Max ≤ 0.01 ≤ 0.005 Bal.

Table 2: Mechanical Properties

Tensile Strength Hardness


Sl No. Sample Dimension (mm) Yield Strength (MPa) Elongation (%)
(MPa) (HRB)

Thickness-
Tested 0.50,0.51,0.51,0.50,0.51 155 291 44 38
MS STRIP
1 Width-24.91,24.89,24.89
0.5x24.9 mm
Thickness- 0.50
Standard 120-170 270-320 ≥42 30-45
Width-24.9

Remarks:

Ref. No. Doc. Code : CRS000008 WALTON HI-TECH INDUSTRIES LTD.

Checked By Approved by Chandra, Kaliakoir, Gazipur


Department: Quality Control (Refrigerator)
Md. Abdus Sabur (37971) Md. Tahasinul Hoque (10139) Section: Wire Harness QC, IQC & QC Lab.
Sub section: Metal IQC