You are on page 1of 2
CALIESYS (LaRNON ETSI SEE Teter rena ed sertifikat | calibration Delete Heleman (page) 1 dar (out 0) 2 Nomor Number) 11200435 Mdentites Alat (Instruments isentty) Nomorldentiikast ‘ertication Numbor Nama Nome Merek Pabrik Manufacturer Tipe | Nomor Seri Type (Serial Number Rentang Ukur Resolusi Range /Resoluion Thermometer Infrared Fluke 568 / 45330395 WS 40-800 °C 1 04 °C Identitas Pemilik (Owner's Identity), NamaPelanggan ‘chases Nes PT. PUTRA TUNGGAL MANDIRITAMA, Alamat — ‘Acisea Kompiek Ruko Balkpapan Baru Blok AB2 No. 28 Balkpapan - KALTIM Tanggal Diterima —= — Delv'of Acceptence 222 October 2020 Tanggel Kalibrasi Date of Calsration Tompat Kalibrasi (06 November 2020 PT. Catesys Indonesia Facet Cabraton Kone inghungan suka Kelombatan mo a1 “ Environmental Condition (Temperature) ‘ 0) (Humidity) 89 5514) Ketelusuran Hasil kalibrasi dilaporkan tertelusur ke satuan pengukuran SI InlllCobretn oss & rece tote Ienetora Sion of Tracecity Gres ug) SNSU-25N Diertan Tenaga ples 11 Noverbe2000 Distsjuoten opoveey Ge E SYD samtusin Mansjomen Tk Tectia Manegonat Qy ee ee ream SiN SoS Prenreysinnovesi CALIESYS eee ee) sertifikat | calibration kalibrasi | certificate Helaman (page) 2 dar (out of 2 Nomor (Number) :__ 811200895, Hasil Kalibrasi/ Caltraton Rosut entitas Standar (Standards Identity) Nama Standar eee Bockoody Source Marek Pabrik aa Manuectrer eruetier erie 6508 /362178/9SSHOS Rentang kur ‘Measurements Range ere Penuniukan Alat ‘Koreksi Instruments Readeg | Correcton Uncertty © CC 7 ey 400.0 13 38 150.0 17 : 37 2000 20 39 2500 22 42 30.0 23 45 500 26 a9 4000 23 55 450.0 24 ae 5000 18 52 Keterangan (Note): Emisivitas daritarmometer radiasidi set pada 0.95, The emissivity of a radiation thermometer is set 2t0.95 Jarak alibrasi 300 mm 2 The estance of caibration is 200mm Nai Koreksi dan ketidakpastian hanya bertaku bila bonda yang dlukur memilikiemisivtes a 095 The correction and uncertainty values vata when the objectto be measured have the emishly 095 ‘4, Alat ini ikalibrasi menggunakan metode perbandingan langsung temnadap Blackbody ‘ork: Isoteeh; no slat: SSHOS berdasarkan prosedurkalloraciMKSP IRT-C1. ‘The Instrument was calibrated using drect comparison method to Blackbody :Ictech, 10: ‘SSHOS basod/on caltraton prosedure MKSPIRT-OF 5, Ketidakpastian pengukuran yang dlaporkan adalah keidakpastian bentangan pada * tingkat kepercayaan sehitar 95% dengan factor cakupan k= 2. The report ofmessurementsuncertay is expended uncer wih confidence vel approximately 96% wih coverage tacerk =2 ¢,_ Ponunjukan Sebenamya =Panunjukan Alst + Koroks! ‘Aetil Resting = natn nents Reading + Corecton hy ‘akhirserfkat end of cartons aang engrtantday|staumenpuiteta esopan Serine nea PY Cates nana ‘spree rote oe rue part ont of eae outa rd ao PT CALTESYS INDONESIA

You might also like