REQUEST BY : QC ITEM NO. :- W/O NO. :- SERIAL NO. :- COST CENTRE :- MATERIAL : C/S CONTRACT NO. : TEMPERATURE : Ambient JOB LOCATION : KRS Workshop PROCEDURE NO. : PO/AE.MIG-OPS/26 DRAWING NO. : FL-RTWS-002 REPORT NO. : /MT.SCI/ MTA /KRS/ XII /2023 DATE OF INSP : Desember 12' 2023 SHEET NO. : 1 of 1
Prepared Edge After Hydrostatic Test
Stage of Examination Finished Weld After Repair After PWHT Other ( Base Material / Pipe Body ) As Welded As Ground Surface Preparation As Machined Other ( After brushing ) Equipment Used : Yoke Permanent Magnet + MPT Kit Magnetic Particle Used : Magnaflux 7HF Contrast Medium : Magnaflux WCP 2 Acceptance Criteria : AWS D1.1 : Identification No. Defect Joint No. Result Remark (ISO Dwg No.) Type Antena Monopole MTA 954 Sw.1 - ACC 25 Meter Sw.2 - ACC
Sw.3 - ACC
Sw.4 - ACC
Sw.5 - ACC
SW 6 - ACC
SW 7 - ACC
Legend of Defect Type
Ri : Rounded Indication Lm : Lamination Li : Linear Indication Por : Porosity Cr : Crack
Interpreted by, Reviewed by, Reviewed by, Reviewed /Approved by
Eddy Agus Wahyudi Hadi S Frans E. Ginting
NDE Level II Client Representative
FOR/SMR.AE.MIG/003 Rev.00 Tgl. Berlaku: 01/08/2019 Hal.1 dari 1