Professional Documents
Culture Documents
Group 3 Electrical Component Specification: A B C A
Group 3 Electrical Component Specification: A B C A
※ Check contact
Glow plug relay
24V 200A Normal : 0.942Ω
(For terminal 1-GND)
CR-24
5
4
1
6
2
3
※ Check contact
B-BR : 24V 1A
B
STC BR ACC H
CS-2
A SUPPLY
B SIG
C RETURN ※ Check contact
Pressure 8~30V
sensor CD-6CD-7
CD-7 CD-16 CD-24 Normal : 0.1Ω
CD-31 CD-32 CD-35 CD-42
CD-43 CD-44 CD-69 CD-70
CD-71
A A
B 4W ※ Check resistance
Resistor
C B A-B : 120Ω
CN-173
4-21
Part name Symbol Specifications Check
CN-80
C 1 ※ Check resistance
Temperature 50˚C : 804Ω
-
sensor 2 80˚C : 310Ω
(hydraulic)
CD-8 100˚C : 180Ω
CD-1
※ Check contact
Air cleaner Pa High level : ∞Ω
pressure switch (N.O TYPE)
Low level : 0Ω
CD-10
※ Check resistance
Full : 50Ω 6/12 : 350Ω
2 11/12 : 100Ω 5/12 : 400Ω
10/12 : 150Ω 4/12 : 450Ω
Fuel sender 1 - 9/12 : 200Ω 3/12 : 500Ω
8/12 : 250Ω 2/12 : 550Ω
CD-2 7/12 : 300Ω 1/12 : 600Ω
Empty warning : 700Ω
3 4 4 ※ Check resistance
3 Normal : About 200Ω
Relay
(air con blower)
2 24V 20A (for terminal 1-3)
1 2 1 0Ω
CR-46 (for terminal 2-4)
1
4 5 1 ※ Check resistance
2
3 Normal : About 160 Ω
Relay 4 24V 16A (for terminal 1-2)
3 2
5 0Ω(for terminal 3-4)
CR-2
CR-2 CR-5 CR-36
CR-36 ∞Ω(for terminal 3-5)
CR-45 CR-62
CR-45 CR-62
4-22
Part name Symbol Specifications Check
30
86
87a 87 85 ※ Check resistance
87 Normal : About 160 Ω
Relay
85 24V 16A (for terminal 85-86)
30 86
87a 0Ω(for terminal 30-87a)
CR-4
CR-4 CR-7
CR-7 CR-9 ∞Ω(for terminal 30-87)
CR-13 CR-35 CR-46
CR-13 CR-35 CR-46
1
※ Check resistance
Solenoid valve 2 24V 1A Normal : 15~25Ω
CN-66 CN-68 CN-70 (for terminal 1-2)
CN-88 CN-135 CN-140
CN-149 CN-236 CN-237
1
※ Check resistance
EPPR valve 2 700mA Normal : 15~25Ω
1
※ Check resistance
Speaker 2 20W
Normal : A fewΩ
CN-23(LH)
CN-24(RH)
7
6
3
2
1
8
※ Check contact
12
5
11
10
11
2
8
Normal
Switch ON : 0 Ω(for terminal 3-7, 4-8)
24V 8A ∞Ω(for terminal 7-9, 8-10)
(locking type)
10
12
12
9
4
※ Check resist
Normal : About 5kΩ
(for terminal A-C)
A +
Accel dial ※ Check voltage
B S - Normal : About 5V
C - (for terminal A-C)
CN-142 : 2~4.5V
(for terminal C-B)
4-23
Part name Symbol Specifications Check
3 ※ Check disconnection
Normal : 1.0Ω
2 ON : 0Ω(For terminal 1-2)
Room lamp 24V 10W ∞Ω(For terminal 1-3)
1
OFF : ∞Ω(For terminal 1-2)
CL-1 0Ω(For terminal 1-3)
CL-7
-
CL-7
1 M
24V 10A ※ Check resistance
Fuel filler pump 2 35ℓ /min Normal : 1.0Ω
CN-61
3 ※ Check operation
2
h S
upply power(24V) to terminal
Hour meter 16~32V
1 No.2 and connect terminal No.1
CN-48 and ground
1 ※ Check operation
Horn DC22~28V Supply power(24V) to each
2 2A terminal and connect ground.
CN-20 CN-25
4-24
Part name Symbol Specifications Check
※ Check contact
2 3 1
Normal : 0Ω(for terminal 1-2)
24V 15A
Safety switch 2 ∞Ω(for terminal 1-3)
(N.C TYPE)
Operating : ∞Ω(for terminal 1-2)
3
1 0Ω(for terminal 1-3)
CS-4
CS-4
1
Receiver dryer P ※ Check contact
2 24V 2.5A Normal : ∞Ω
CN-29
CN-29
10
11
12
13
14
15
16
1
2
3
4
5
6
7
9
8
24V 2A
SPK FRT RH+
20~25V
REMOCON+
USB plalyer
BACK UP+
TEL MUTE
ANT 12V
GND
ACC
ILL+
ILL-
NC
NC
CN-27
CN-22
3 1
2
5 3
4 ※ Check disconnection
Wiper motor 4
24V 2A
5
Normal : 7Ω(for terminal 2-6)
6 M 2 6
CN-21
4-25
Part name Symbol Specifications Check
3 12V 12V
DC/DC ※ Check voltage
2 24V
Converter 1 GND 24V 12V 3A 24V (for terminal 1-2)
12V (for terminal 1-3)
CN-138
B+
G
L
3~
Delco Remy ※ Check contact
Alternator U
24V 55A Normal : 0Ω (for terminal B+-I)
Normal : 24~27.5V
CN-74
M
M
Denso ※ Check contact
Starter
24V 4.5kW Normal : 0.1Ω
B+
CN-45
※ Check contact
Travel alarm 24V 0.5A Normal : 5.2Ω
CN-81
1
Aircon ※ Check contact
compressor 24V 79W Normal : 13.4Ω
CN-28
4-26
Part name Symbol Specifications Check
CR-23
1 M ※ Check resistance
Blower motor 24V 9.5A
2 Normal : 2.5Ω(for terminal 1-2)
※ Check resistance
Duct sensor 2 1˚C OFF Normal : 0Ω(for terminal 1-2),
(switch) 4˚C ON the atmosphere temp :
1
Over 4˚C
CS-1
CS-1
Switch
(power max, 1 ※ Check resistance
one touch 24V 6A
2 Normal : ∞Ω
decal, horn,
breaker)
CS-5 CS-19
CS-26 CS-29
※ Check disconnection
2
Normal : 0Ω
Circuit breaker 1 60A (connect ring terminal and check
CS-60 CS-95
resist between terminal 1 and 2)
4-27
Part name Symbol Specifications Check
※ Check disconnection
Master switch 6-36V
Normal : 0.1Ω
CS-74A, CS-74B
1
Quick clamp 24V 200mA
buzzer 2 107±4dB
-
CN-113
1
Socket 2
12V 10A -
CN-139
※ Check contact
Normal
1
2
3
6
7
4
12
5
11
10
11
10
4
12
※ Check contact
1 DOC OUTLET TEMP
2 RETURN Normal
DPF temp 3 DOC INLET TEMP 5.0V 0.2A 0Ω(for terminal 1-2, 47.5Ω)
sensor 4 DPF OUTLET TEMP
∞Ω(for terminal 1-3, 1kΩ)
CD-94 ∞Ω(for terminal 4-1, 1kΩ)
※ Check contact
1 RETURN
2 DPF DELTTA PRESS Normal
DPF pressure 3 DPF OUTLET PRESS 5.0V 0.2A 0Ω(for terminal 1-2, 47.5Ω)
sensor 4 PRESS SENSOR POWER
∞Ω(for terminal 1-3, 1kΩ)
CD-95 ∞Ω(for terminal 4-1, 1kΩ)
2
※ Check contact
WIF sensor 1 -
Normal : 68.8 ~ 4.94Ω
CD-45
4-28