You are on page 1of 15

Water 

Feature ‐01
Design summary

Water Feature details

Shape : Irrgegular Length : m


Type : Weir Edge Width : m
Water : Fresh water Area : 175 m2
Location : Above ground Depth : 0.3 m
Water Feature: Overflow Volume : 52.50 m3
Total WF Volume : 52.50 m3
Total Volume : 6.18 m3

Filtration System
Pump
Turnover rate : 1 Hrs
Recirculation rate : 6.18 m³/hr
No.of acting pumps : 1 no's
Pump flow rate : 6.18 m³/hr

Filter:

Filter area required = Design Flow rate/Filtration Rate
Design Flow rate : 6.18 m3/hr
Filtration rate/velocity : 50 m3/m2/hr
Filter area : 0.123552 m2
Max. Working pressure : 2.5 Kg/Cm2

Proposed sand media filter
Make :
Model :
Diameter : mm
3
Flow Rate : 9 m /hr
No. of sand media Filters : 1 Duty

Weir Circulation System

Perimeter of Wate Feature weir at Water Fall (1 no. of basin) : 52 m
Flow required to Form 1mm Thick Weir of 1Mtr Length Flow required : 19.8 lpm
Weit Thickness : 2 mm
Required Circulation rate for 1 no. of basin : 123.552 m³/hr
No. of basin : 1 no's
Required Circulation rate : 123.552 m³/hr

Balancing Tank

Water feature volume : 52.5 m³/hr


Circulation flow : 123.552 m³/hr
Water from pump to water feature and overflow drain to balancing tank takes : 3 min
Required Balancing tank capcity 6.18 m³
Chemical Dosing system

Chlorine and bromine feeder  5Kg

Capacity  : 5Kg
Make :
Model :

Pipe Size & Pool fittings

1. Water velocity in pipe network

Suction pipe network : 1.5 m/s


Discharge pipe network : 2 m/s
Gravity pipe network : 0.5 m/s

2. Design flow rate : 123.55 m3/hr

3. Pipe size selection

A. Overflow pipe size
Design flow rate : 123.55 m³/hr
Using the mass flow equation, Q     = AV
Area of the skimmer pipe line, A = Q/V : 0.06864 m2
Diameter of the pipe : 0.295627 m
Overflow line size : 11.6 inch
Proposed Overflow line pipe size : 6" x 3 no's

B. Return inlet pipe size
Design flow rate : 123.55 m³/hr
Using the mass flow equation, Q     = AV
Area of the Return pipe line, A = Q/V : 0.01716 m2
Diameter of the pipe : 0.147813 m
Return line size : 5.82 inch
Proposed Return inlet Pipe size : 6"x2 no's

4. Overflow Fitting
Proposed Overflow fitting
Make : Astral
Model : 00302
Flow rate : 7 m³/hr
Circulation rate  : 123.55 m³
No. of Overflow fittings required : 18 no's
No. of Overflow fittings Proposed : 20 no's

5. Inlet Fitting
Proposed Inlet Fitting
Make : Astral
15839
Model :
Flow rate : 14 m³/hr
Circulation rate  : 123.55 m³
No. of Inlet fittings required : 9 no's
No. of inlet fittings Proposed : 22 no's
Head Loss in circulation network

Total Head Loss in the Circulation Pipe Network = Head loss in pipes + Head loss in valves and fittings + Head loss in equipments

1. Head loss in pipes

Friction head loss in feet of water in 100 feet of pipe(Hazen‐williams Equation) (f) = 0.2083(100/c) 1.852 x Q1.852/ D4.8655
C ‐ Hazen ‐Williams  Roughness constant
Q ‐ Flow rate in Gallons/Min.
D ‐ Internal dia of the pipe in inch

Hazen ‐ 
Friction 
Williams  Pipe Diameter Flow(Q) Quantity Total head loss (H)
S.No. Pipe Length Description head loss(f)
Roughness
constant  inch mm m3/hr Gal/min (m) (f) (f) (m)
1 From  pump to  Inlet header 150 6 152.40 61.78 271.99 0.0051912 50 164.04 0.85 0.259561
2 From  pump to  Inlet header 150 6 152.40 61.78 272.01 0.0051918 50 164.04 0.85 0.259592
Total Head loss in Pipes (m) 0.52

2. Head loss in valves and fittings
hL = ζ x V2/2g
hL ‐ Head loss in fittings
ζ ‐ Minor Loss co‐efficient 
V ‐ Velocity = Discharge(Q)/Area(mm)
g ‐ Acceleration due to gravity

Acceleratio
Minor Loss 
Velocity n due to  Total 
S.no. Description Diameter Quantity Flow(Q) Area(A) V2/2g co‐
(V) =Q/A gravity Head Loss
efficient 
(g)
3
inch mm no's m /hr m3/sec m2 m/s m/s 2
m ζ m
1 Elbow 90° 6 152.40 6 61.78 0.01716 0.0182415 0.94 9.81 0.045104 1 0.270625
2 Elbow 45° 6 152.40 6 61.78 0.01716 0.0182415 0.94 9.81 0.045104 0.4 0.10825
3 90° Tee 6 152.40 6 61.78 0.017161 0.0182415 0.94 9.81 0.04511 0.35 0.094731
4 Butterfly valve 6 152.40 2 61.78 0.017161 0.0182415 0.94 9.81 0.04511 0.3 0.027066
5 Check valve 6 152.40 2 61.78 0.017161 0.0182415 0.94 9.81 0.04511 2 0.18044
6 Elbow 90° 3 76.20 4 25.00 0.006944 0.0045604 1.52 9.81 0.118189 0.35 0.165464
7 Elbow 45° 3 76.20 4 25.00 0.006944 0.0045604 1.52 9.81 0.118189 0.3 0.141827
8 90° Tee 3 76.20 4 25.00 0.006944 0.0045604 1.52 9.81 0.118189 2 0.94551
Total Head loss in Fittings (m) 1.933912

Total Head Loss in the circulation Pipe Network
Total Head Loss in the Filtration pipe 
S.No. Total head loss(H)
network
1 Head loss in pipes (H1) 0.519
2 Head loss in Valves & Fittings (H2) 1.934
3 Elevation Difference (H3) 6.000
Total Head loss 8.453
Factor of Safety 10% 0.845
Total Head Required (H) 9.30

3
Required pump capacity :75 m /hr @ 15 m of Head 

Proposed Circulation Pump

Make
Model : 
3
Capacity : 75 m /hr @ 15 m of Head 
No.of Pumps : 2 Duty + 1 Standby

Head Loss in Filtration network

Total Head Loss in the Filtration Pipe Network = Head loss in pipes + Head loss in valves and fittings + Head loss in equipments

1. Head loss in pipes

Friction head loss in feet of water in 100 feet of pipe(Hazen‐williams Equation) (f) = 0.2083(100/c) 1.852 x Q1.852/ D4.8655
C ‐ Hazen ‐Williams  Roughness constant
Q ‐ Flow rate in Gallons/Min.
D ‐ Internal dia of the pipe in inch

Hazen ‐ 
Friction 
Williams  Pipe Diameter Flow(Q) Quantity Total head loss (H)
S.No. Pipe Length Description head loss(f)
Roughness
constant  inch mm m3/hr Gal/min (m) (f) (f) (m)
1 From  pump to  Inlet 150 2 50.80 6.18 27.20 0.0153004 20 65.62 1.00 0.306008
Total Head loss in Pipes (m) 0.31

2. Head loss in valves and fittings
2
hL = ζ x V /2g
hL ‐ Head loss in fittings
ζ ‐ Minor Loss co‐efficient 
V ‐ Velocity = Discharge(Q)/Area(mm)
g ‐ Acceleration due to gravity
Acceleratio
Minor Loss 
Velocity n due to  2 Total 
S.no. Description Diameter Quantity Flow(Q) Area(A) V /2g co‐
(V) =Q/A gravity Head Loss
efficient 
(g)
3
inch mm no's m /hr m3/sec m2 m/s m/s2 m ζ m
1 Elbow 90° 2 50.80 6 6.18 0.001716 0.0020268 0.85 9.81 0.036534 1 0.219206
2 Elbow 45° 2 50.80 4 6.18 0.001716 0.0020268 0.85 9.81 0.036534 0.4 0.058455
3 90° Tee 2 50.80 2 6.18 0.001716 0.0020268 0.85 9.81 0.036534 0.35 0.025574
4 Butterfly valve 2 50.80 2 6.18 0.001716 0.0020268 0.85 9.81 0.036534 0.3 0.021921
5 Check valve 2 50.80 1 6.18 0.001716 0.0020268 0.85 9.81 0.036534 2 0.073069
Total Head loss in Fittings (m) 0.398224

3. Head loss in equipments

Total head 
S.no Equipment Description Loss (H)
(m)
1 Sand media filter 5
Total Head loss in Equipments (m) 5

Total Head Loss in the Filtration Pipe Network

Total Head Loss in the Filtration pipe 
S.No. Total head loss(H)
network
1 Head loss in pipes (H1) 0.306
2 Head loss in Valves & Fittings (H2) 0.398
3 Head Loss in Equipments (H3) 5.000
4 Elevation Difference (H3) 2.000
Total Head loss 7.704
Factor of Safety 10% 0.770
Total Head Required (H) 8.47

Required pump capacity : 8 m3/hr @ 10 m of Head 

Proposed Filtration Pump

Make
Model
3
Capacity : 8 m /hr @ 10 m of Head 
No.of Pumps : 1 Duty + 1 Standby
Water Feature ‐02
Design summary

Water Feature details

Shape : Irrgegular Length : m


Type : Weir Edge Width : m
Water : Fresh water Area : 100 m2
Location : Above ground Depth : 0.3 m
Water Feature: Overflow Volume : 30.00 m3
Total WF Volume : 30.00 m3
Total Volume : 4.90 m3

Filtration System
Pump
Turnover rate : 2 Hrs
Recirculation rate : 2.45 m³/hr
No.of acting pumps : 1 no's
Pump flow rate : 2.45 m³/hr

Filter:

Filter area required = Design Flow rate/Filtration Rate
Design Flow rate : 2.45 m3/hr
Filtration rate/velocity : 50 m3/m2/hr
Filter area : 0.049005 m2
Max. Working pressure : 2.5 Kg/Cm2

Proposed sand media filter
Make :
Model :
Diameter : mm
3
Flow Rate : 9 m /hr
No. of sand media Filters : 1 Duty

Weir Circulation System

Perimeter of Wate Feature weir at Water Fall (1 no. of basin) : 55 m
Flow required to Form 1mm Thick Weir of 1Mtr Length Flow required : 19.8 lpm
Weit Thickness : 1.5 mm
Required Circulation rate for 1 no. of basin : 98.01 m³/hr
No. of basin : 1 no's
Required Circulation rate : 98.01 m³/hr

Balancing Tank

Water feature volume : 30 m³/hr
Circulation flow : 98.01 m³/hr
Water from pump to water feature and overflow drain to balancing tank takes : 3 min
Required Balancing tank capcity 4.90 m³
Chemical Dosing system

Chlorine and bromine feeder  5Kg

Capacity  : 5Kg
Make :
Model :

Pipe Size & Pool fittings

1. Water velocity in pipe network

Suction pipe network : 1.5 m/s


Discharge pipe network : 2 m/s
Gravity pipe network : 0.5 m/s

2. Design flow rate : 98.01 m3/hr

3. Pipe size selection

A. Overflow pipe size
Design flow rate : 98.01 m³/hr
Using the mass flow equation, Q     = AV
Area of the skimmer pipe line, A = Q/V : 0.05445 m2
Diameter of the pipe : 0.263302 m
Overflow line size : 10.4 inch
Proposed Overflow line pipe size : 6" x 3 no's

B. Return inlet pipe size
Design flow rate : 98.01 m³/hr
Using the mass flow equation, Q     = AV
Area of the Return pipe line, A = Q/V : 0.013613 m2
Diameter of the pipe : 0.131651 m
Return line size : 5.18 inch
Proposed Return inlet Pipe size : 8.00 Inch

4. Overflow Fitting
Proposed Overflow fitting
Make : Astral
Model : 00302
Flow rate : 7 m³/hr
Circulation rate  : 98.01 m³
No. of Overflow fittings required : 15 no's
No. of Overflow fittings Proposed : 30 no's

5. Inlet Fitting
Proposed Inlet Fitting
Make : Astral
15839
Model :
Flow rate : 14 m³/hr
Circulation rate  : 98.01 m³
No. of Inlet fittings required : 8 no's
No. of inlet fittings Proposed : 20 no's
Head Loss in circulation network

Total Head Loss in the Circulation Pipe Network = Head loss in pipes + Head loss in valves and fittings + Head loss in equipments

1. Head loss in pipes

Friction head loss in feet of water in 100 feet of pipe(Hazen‐williams Equation) (f) = 0.2083(100/c) 1.852 x Q1.852/ D4.8655
C ‐ Hazen ‐Williams  Roughness constant
Q ‐ Flow rate in Gallons/Min.
D ‐ Internal dia of the pipe in inch

Hazen ‐ 
Friction 
Williams  Pipe Diameter Flow(Q) Quantity Total head loss (H)
S.No. Pipe Length Description head loss(f)
Roughness
constant  inch mm m3/hr Gal/min (m) (f) (f) (m)
1 From  pump to  Inlet header 150 8 203.20 98.01 431.53 0.0030103 50 164.04 0.49 0.150517
2 From  pump to  Inlet header 150 6 152.40 49.01 215.76 0.0033806 50 164.04 0.55 0.169031
3 From  pump to  Inlet header 150 4 101.60 24.50 107.88 0.0067338 50 164.04 1.10 0.336691
Total Head loss in Pipes (m) 0.49

2. Head loss in valves and fittings
hL = ζ x V2/2g
hL ‐ Head loss in fittings
ζ ‐ Minor Loss co‐efficient 
V ‐ Velocity = Discharge(Q)/Area(mm)
g ‐ Acceleration due to gravity

Acceleratio
Minor Loss 
Velocity n due to  2 Total 
S.no. Description Diameter Quantity Flow(Q) Area(A) V /2g co‐
(V) =Q/A gravity Head Loss
efficient 
(g)
3
inch mm no's m /hr m3/sec m2 m/s m/s 2
m ζ m
1 Elbow 90° 8 203.20 15 98.01 0.027225 0.0324293 0.84 9.81 0.035922 1 0.538832
2 Elbow 45° 8 203.20 15 98.01 0.027225 0.0324293 0.84 9.81 0.035922 0.4 0.215533
3 90° Tee 8 203.20 15 24.50 0.006806 0.0324293 0.21 9.81 0.002245 0.35 0.011787
4 Butterfly valve 8 203.20 3 24.50 0.006806 0.0324293 0.21 9.81 0.002245 0.3 0.002021
5 Check valve 8 203.20 3 24.50 0.006806 0.0324293 0.21 9.81 0.002245 2 0.013471
6 Elbow 90° 6 152.40 20 25.00 0.006944 0.0182415 0.38 9.81 0.007387 0.35 0.051708
7 Elbow 45° 6 152.40 20 25.00 0.006944 0.0182415 0.38 9.81 0.007387 0.3 0.044321
8 90° Tee 6 152.40 20 25.00 0.006944 0.0182415 0.38 9.81 0.007387 2 0.295472
Total Head loss in Fittings (m) 1.173144

Total Head Loss in the circulation Pipe Network
Total Head Loss in the Filtration pipe 
S.No. Total head loss(H)
network
1 Head loss in pipes (H1) 0.487
2 Head loss in Valves & Fittings (H2) 1.173
3 Elevation Difference (H3) 6.000
Total Head loss 7.660
Factor of Safety 10% 0.766
Total Head Required (H) 8.43

3
Required pump capacity :50 m /hr @ 18 m of Head 

Proposed Circulation Pump

Make
Model : 
3
Capacity : 50 m /hr @ 18 m of Head 
No.of Pumps : 2 Duty + 1 Standby

Head Loss in Filtration network
s
Total Head Loss in the Filtration Pipe Network = Head loss in pipes + Head loss in valves and fittings + Head loss in equipments

1. Head loss in pipes

Friction head loss in feet of water in 100 feet of pipe(Hazen‐williams Equation) (f) = 0.2083(100/c) 1.852 x Q1.852/ D4.8655
C ‐ Hazen ‐Williams  Roughness constant
Q ‐ Flow rate in Gallons/Min.
D ‐ Internal dia of the pipe in inch

Hazen ‐ 
Friction 
Williams  Pipe Diameter Flow(Q) Quantity Total head loss (H)
S.No. Pipe Length Description head loss(f)
Roughness
constant  inch mm m3/hr Gal/min (m) (f) (f) (m)
1 From  pump to  Inlet 150 2 50.80 2.45 10.79 0.0027601 20 65.62 0.18 0.055202
Total Head loss in Pipes (m) 0.06

2. Head loss in valves and fittings
hL = ζ x V2/2g
hL ‐ Head loss in fittings
ζ ‐ Minor Loss co‐efficient 
V ‐ Velocity = Discharge(Q)/Area(mm)
g ‐ Acceleration due to gravity

Acceleratio
Minor Loss 
Velocity n due to  2 Total 
S.no. Description Diameter Quantity Flow(Q) Area(A) V /2g co‐
(V) =Q/A gravity Head Loss
efficient 
(g)
3
inch mm no's m /hr m3/sec m2 m/s m/s2 m ζ m
1 Elbow 90° 2 50.80 6 2.45 0.000681 0.0020268 0.34 9.81 0.005748 1 0.034485
2 Elbow 45° 2 50.80 4 2.45 0.000681 0.0020268 0.34 9.81 0.005748 0.4 0.009196
3 90° Tee 2 50.80 2 2.45 0.000681 0.0020268 0.34 9.81 0.005748 0.35 0.004023
4 Butterfly valve 2 50.80 2 2.45 0.000681 0.0020268 0.34 9.81 0.005748 0.3 0.003449
5 Check valve 2 50.80 1 2.45 0.000681 0.0020268 0.34 9.81 0.005748 2 0.011495
Total Head loss in Fittings (m) 0.062648

3. Head loss in equipments

Total head 
S.no Equipment Description Loss (H)
(m)
1 Sand media filter 5
Total Head loss in Equipments (m) 5

Total Head Loss in the Filtration Pipe Network

Total Head Loss in the Filtration pipe 
S.No. Total head loss(H)
network
1 Head loss in pipes (H1) 0.055
2 Head loss in Valves & Fittings (H2) 0.063
3 Head Loss in Equipments (H3) 5.000
4 Elevation Difference (H3) 2.000
Total Head loss 7.118
Factor of Safety 10% 0.712
Total Head Required (H) 7.83

3
Required pump capacity : 8 m /hr @ 10 m of Head 

Proposed Filtration Pump

Make
Model
3
Capacity : 8 m /hr @ 10 m of Head 
No.of Pumps : 1 Duty + 1 Standby
Water Feature ‐03
Design summary

Water Feature details

Shape : Irrgegular Length : m


Type : Weir Edge Width : m
Water : Fresh water Area : 133 m2
Location : Above ground Depth : 0.3 m
Water Feature: Overflow Volume : 39.90 m3
Total WF Volume : 39.90 m3
Balancing Tank : 13.31 m3

Filtration System
Pump
Turnover rate : 2 Hrs
Recirculation rate : 6.65 m³/hr
No.of acting pumps : 1 no's
Pump flow rate : 6.65 m³/hr

Filter:

Filter area required = Design Flow rate/Filtration Rate
Design Flow rate : 6.65 m3/hr
Filtration rate/velocity : 50 m3/m2/hr
Filter area : 0.133056 m2
Max. Working pressure : 2.5 Kg/Cm2

Proposed sand media filter
Make :
Model :
Diameter : mm
3
Flow Rate : 9 m /hr
No. of sand media Filters : 1 Duty

Weir Circulation System

Perimeter of Wate Feature weir at Water Fall (1 no. of basin) : 112 m
Flow required to Form 1mm Thick Weir of 1Mtr Length Flow required : 19.8 lpm
Weit Thickness : 2 mm
Required Circulation rate for 1 no. of basin : 266.112 m³/hr
No. of basin : 1 no's
Required Circulation rate : 266.112 m³/hr

Balancing Tank

Water feature volume : 39.9 m³/hr


Circulation flow : 266.112 m³/hr
Water from pump to water feature and overflow drain to balancing tank takes : 3 min
Required Balancing tank capcity 13.31 m³
Chemical Dosing system

Chlorine and bromine feeder  5Kg

Capacity  : 5Kg
Make :
Model :

Pipe Size & Pool fittings

1. Water velocity in pipe network

Suction pipe network : 1.5 m/s


Discharge pipe network : 2 m/s
Gravity pipe network : 0.5 m/s

2. Design flow rate : 266.11 m3/hr

3. Pipe size selection

A. Overflow pipe size
Design flow rate : 266.11 m³/hr
Using the mass flow equation, Q     = AV
Area of the skimmer pipe line, A = Q/V : 0.14784 m2
Diameter of the pipe : 0.433861 m
Overflow line size : 17.1 inch
Proposed Overflow line pipe size : 8" x 3 no's

B. Return inlet pipe size
Design flow rate : 266.11 m³/hr
Using the mass flow equation, Q     = AV
Area of the Return pipe line, A = Q/V : 0.03696 m2
Diameter of the pipe : 0.216931 m
Return line size : 8.54 inch
Proposed Return inlet Pipe size : 8"x2 no's

4. Overflow Fitting
Proposed Overflow fitting
Make : Astral
Model : 00302
Flow rate : 7 m³/hr
Circulation rate  : 266.11 m³
No. of Overflow fittings required : 39 no's
No. of Overflow fittings Proposed : 40 no's

5. Inlet Fitting
Proposed Inlet Fitting
Make : Astral
15839
Model :
Flow rate : 14 m³/hr
Circulation rate  : 266.11 m³
No. of Inlet fittings required : 20 no's
No. of inlet fittings Proposed : 25 no's
Head Loss in circulation network

Total Head Loss in the Circulation Pipe Network = Head loss in pipes + Head loss in valves and fittings + Head loss in equipments

1. Head loss in pipes

Friction head loss in feet of water in 100 feet of pipe(Hazen‐williams Equation) (f) = 0.2083(100/c) 1.852 x Q1.852/ D4.8655
C ‐ Hazen ‐Williams  Roughness constant
Q ‐ Flow rate in Gallons/Min.
D ‐ Internal dia of the pipe in inch

Hazen ‐ 
Friction 
Williams  Pipe Diameter Flow(Q) Quantity Total head loss (H)
S.No. Pipe Length Description head loss(f)
Roughness
constant  inch mm m3/hr Gal/min (m) (f) (f) (m)
1 From  pump to  Inlet header 150 8 203.20 88.70 390.55 0.0025025 50 164.04 0.41 0.125125
2 From  pump to  Inlet header 150 8 203.20 59.40 261.53 0.0011908 50 164.04 0.20 0.059539
3 From  pump to  Inlet header 150 8 203.20 59.40 261.53 0.0011908 50 164.04 0.20 0.059539
Total Head loss in Pipes (m) 0.18

2. Head loss in valves and fittings
hL = ζ x V2/2g
hL ‐ Head loss in fittings
ζ ‐ Minor Loss co‐efficient 
V ‐ Velocity = Discharge(Q)/Area(mm)
g ‐ Acceleration due to gravity

Acceleratio
Minor Loss 
Velocity n due to  2 Total 
S.no. Description Diameter Quantity Flow(Q) Area(A) V /2g co‐
(V) =Q/A gravity Head Loss
efficient 
(g)
3
inch mm no's m /hr m3/sec m2 m/s m/s 2
m ζ m
1 Elbow 90° 8 203.20 15 88.70 0.02464 0.0324293 0.76 9.81 0.029424 1 0.441366
2 Elbow 45° 8 203.20 15 88.70 0.02464 0.0324293 0.76 9.81 0.029424 0.4 0.176546
3 90° Tee 8 203.20 15 59.40 0.0165 0.0324293 0.51 9.81 0.013195 0.35 0.069271
4 Butterfly valve 8 203.20 3 59.40 0.0165 0.0324293 0.51 9.81 0.013195 0.3 0.011875
5 Check valve 8 203.20 3 59.40 0.0165 0.0324293 0.51 9.81 0.013195 2 0.079167
6 Elbow 90° 4 101.60 20 25.00 0.006944 0.0081073 0.86 9.81 0.037396 0.35 0.26177
7 Elbow 45° 4 101.60 20 25.00 0.006944 0.0081073 0.86 9.81 0.037396 0.3 0.224374
8 90° Tee 4 101.60 20 25.00 0.006944 0.0081073 0.86 9.81 0.037396 2 1.495827
Total Head loss in Fittings (m) 2.760197

Total Head Loss in the circulation Pipe Network
Total Head Loss in the Filtration pipe 
S.No. Total head loss(H)
network
1 Head loss in pipes (H1) 0.185
2 Head loss in Valves & Fittings (H2) 2.760
3 Elevation Difference (H3) 6.000
Total Head loss 8.945
Factor of Safety 10% 0.894
Total Head Required (H) 9.84

3
Required pump capacity :100 m /hr @ 18 m of Head 

Proposed Circulation Pump

Make
Model : 
3
Capacity : 100 m /hr @ 18 m of Head 
No.of Pumps : 3 Duty + 1 Standby

Head Loss in Filtration network
s
Total Head Loss in the Filtration Pipe Network = Head loss in pipes + Head loss in valves and fittings + Head loss in equipments

1. Head loss in pipes

Friction head loss in feet of water in 100 feet of pipe(Hazen‐williams Equation) (f) = 0.2083(100/c) 1.852 x Q1.852/ D4.8655
C ‐ Hazen ‐Williams  Roughness constant
Q ‐ Flow rate in Gallons/Min.
D ‐ Internal dia of the pipe in inch

Hazen ‐ 
Friction 
Williams  Pipe Diameter Flow(Q) Quantity Total head loss (H)
S.No. Pipe Length Description head loss(f)
Roughness
constant  inch mm m3/hr Gal/min (m) (f) (f) (m)
1 From  pump to  Inlet 150 2 50.80 6.65 29.29 0.0175513 20 65.62 1.15 0.351026
Total Head loss in Pipes (m) 0.35

2. Head loss in valves and fittings
hL = ζ x V2/2g
hL ‐ Head loss in fittings
ζ ‐ Minor Loss co‐efficient 
V ‐ Velocity = Discharge(Q)/Area(mm)
g ‐ Acceleration due to gravity

Acceleratio
Minor Loss 
Velocity n due to  2 Total 
S.no. Description Diameter Quantity Flow(Q) Area(A) V /2g co‐
(V) =Q/A gravity Head Loss
efficient 
(g)
3
inch mm no's m /hr m3/sec m2 m/s m/s2 m ζ m
1 Elbow 90° 2 50.80 6 6.65 0.001848 0.0020268 0.91 9.81 0.042371 1 0.254227
2 Elbow 45° 2 50.80 4 6.65 0.001848 0.0020268 0.91 9.81 0.042371 0.4 0.067794
3 90° Tee 2 50.80 2 6.65 0.001848 0.0020268 0.91 9.81 0.042371 0.35 0.02966
4 Butterfly valve 2 50.80 2 6.65 0.001848 0.0020268 0.91 9.81 0.042371 0.3 0.025423
5 Check valve 2 50.80 1 6.65 0.001848 0.0020268 0.91 9.81 0.042371 2 0.084742
Total Head loss in Fittings (m) 0.461846

3. Head loss in equipments

Total head 
S.no Equipment Description Loss (H)
(m)
1 Sand media filter 5
Total Head loss in Equipments (m) 5

Total Head Loss in the Filtration Pipe Network

Total Head Loss in the Filtration pipe 
S.No. Total head loss(H)
network
1 Head loss in pipes (H1) 0.351
2 Head loss in Valves & Fittings (H2) 0.462
3 Head Loss in Equipments (H3) 5.000
4 Elevation Difference (H3) 2.000
Total Head loss 7.813
Factor of Safety 10% 0.781
Total Head Required (H) 8.59

3
Required pump capacity : 8 m /hr @ 10 m of Head 

Proposed Filtration Pump

Make
Model
3
Capacity : 8 m /hr @ 10 m of Head 
No.of Pumps : 1 Duty + 1 Standby

You might also like