Professional Documents
Culture Documents
Septic Tanks
Pump Tanks
Fire Protection/
Water Storage Systems
Privy Tanks
Oil Interceptors
Tank Accessories
Brooklin Concrete is a precast concrete manufacturer of various designs
and sizes in pump tanks, single chamber tanks, septic tanks, and specialty
systems. We maintain strict quality control during production and offer a
comprehensive line of products. Our complete fleet of crane equipped trucks
can deliver and place your new tank. More importantly, our commitment to
customers extends beyond the sale. Quality, versatility and service, along
with competitive pricing constitute our main strengths.
Our in house design staff can prepare shop drawings for engineer review,
including custom designs if required. No project is too big or small for our
team to offer support.
Thank you for your interest in Brooklin Concrete, we hope you will find this
catalogue a valuable guide in your septic system needs. Included for your
use in this guide are product descriptions, design pages for each item, and
accessory descriptions.
GENERAL NOTES:
[54"]
1372
4. MIN OVERHEAD CLEARANCE OF 18FT IS
REQUIRED
1
4" INLET
CAST-A-SEAL 402
TUF-TITE EFFLUENT
FILTER EF-6
OPTIONAL INLET OPENING 12" x 4"
4" PVC POLYSEAL 4" OUTLET (TYP.)
CAST-A-SEAL 402 BAFFLE
BAFFLE
127
152
[5"] (TYP.)
1344 [6"](TYP.)
LIQUID DEPTH
[70"]
1778
[67"]
1702
255
[58"]
1470
[56"]
1422 (TYP.)
775
851
[30 1/2"]
[33 1/2"]
76
[3"]
76 76 76
[3"]
76
[3"] [3"] [3"]
2540 1372
[100"] [54"]
SECTION A SECTION B
SCALE:1/30 SCALE:1/30
CONCRETE: 35MPa at 28 days / 5000PSI UNIT WEIGHT: 6,490lbs / 2,943kg DRAWN BY:
AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 3600 LITRES SEPTIC TANK
800 IMPERIAL GALLON
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-B66
BROOKLIN, ON DATE: WORKING CAPACITY: 3,723 LITRES TO INVERT OF OUTLET
A23.1 /A23.3 G30.18 Fy=400MPa
1-800-655-3430 JAN / 2018
TOTAL CAPACITY: 4,259 LITRES TO UNDERSIDE OF CHAMBER LID
2543
[100"]
GENERAL NOTES:
[66"]
1679
4. MIN OVERHEAD CLEARANCE OF 18FT IS
REQUIRED
2
TUF-TITE EFFLUENT
FILTER EF-6
OPENING 12" x 4" (TYP.)
OPTIONAL INLET
4" PVC POLYSEAL 4" OUTLET
BAFFLE CAST-A-SEAL 402
BAFFLE
102
[4"](TYP.)
1041
LIQUID DEPTH
[59"]
1498
[56"]
1422
357 152
[46"]
1167
[44"]
1117
(TYP.) [6"](TYP.)
635
[25"]
711
[28"]
76
[3"]
76 76 76
[3"]
76
[3"] [3"] [3"]
2543 1679
[100"] [66"]
SECTION A SECTION B
SCALE:1/30 SCALE:1/30
CONCRETE: 35MPa at 28 days/5000PSI UNIT WEIGHT: 6,940lbs / 3,147kg DRAWN BY:
AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND
LOW HEIGHT
800 IMPERIAL GALLON
3600 LITRES SEPTIC TANK
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-B66
DATE: WORKING CAPACITY: 3,668 LITRES TO INVERT OF OUTLET
BROOKLIN, ON A23.1 /A23.3 G30.18 Fy=400MPa
1-800-655-3430 JAN/2018 TOTAL CAPACITY: 4,450 LITRES TO UNDERSIDE OF CHAMBER LID
2540
[100"]
GENERAL NOTES:
[66"]
1676
REQUIRED
24" x 6" TUF-TITE RISER WITH 24" x 6" TUF-TITE RISER WITH
3
2450 COVER. 2 REQUIRED COVER. 2 REQUIRED 1586
[96 1/2"] [62 1/2"]
76
4" INLET
CAST-A-SEAL 402
[3"](TYP.)
TUF-TITE
EFFLUENT
FILTER EF-6
OPTIONAL INLET OPENING 12" x 4"
4" PVC POLYSEAL 4" OUTLET (TYP.)
CAST-A-SEAL 402
BAFFLE BAFFLE
127
[5"] (TYP.)
1344
LIQUID DEPTH
[69"]
1752
[66"]
[66"]
1676
1676
152 508
[58"]
1472
[56"]
1420
(TYP.) [20"](TYP.)
838
[33"]
76
76
[3"]
[3"]
76 76
[3"] (TYP.) [3"](TYP.)
SECTION A SECTION B
SCALE:1/30 SCALE:1/30
GENERAL NOTES:
[86"]
2184
5. ALL UNITS MUST BE HANDLED WITH
PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)
4
[113"] [82"]
4" INLET
CAST-A-SEAL 402
TUF-TITE
EFFLUENT
FILTER EF-6 OPENING 12" x 4"
OPTIONAL INLET
4" PVC POLYSEAL 4" OUTLET (TYP.)
127
CAST-A-SEAL 402
BAFFLE BAFFLE
[5"] (TYP.)
940
LIQUID DEPTH
[54"]
1371
[51"]
1295
153 508
[42"]
1067
[40"]
1016
(TYP.) [20"](TYP.)
648
[25 1/2"]
76
76
[3"]
[3"]
76 76
[3"] (TYP.) SECTION A [3"] SECTION B
SCALE:1/30 SCALE:1/30
CONCRETE: 35MPa at 28 days / 5000PSI UNIT WEIGHT: 11,620 lbs DRAWN BY:
CPA CERTIFIED S.RIMLAND
LOW HEIGHT
AIR ENTRAINMENT: 6-8%
1000 IMPERIAL GALLON
4500 LITRES SEPTIC TANK
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-BB6-00
DATE: WORKING CAPACITY: 5,214 LITRES TO INVERT OF OUTLET
BROOKLIN, ON A23.1 /A23.3 G30.18 Fy=400MPa
1-800-655-3430 JAN/2018 TOTAL CAPACITY: 6,305 LITRES TO UNDERSIDE OF CHAMBER LID
3001
[118 1/8"]
10M LIFTING ANCHOR
4 REQUIRED (TYP.)
GENERAL NOTES:
2290
PROPER LIFTING EQUIPMENT (I.E.
[90 1/8"]
SPREADER BAR)
5
24" x 6" TUF-TITE
RISER WITH COVER TOP VIEW
2 REQUIRED
SCALE:1/30
24" x 6" TUF-TITE 10M LIFTING ANCHOR
4" INLET OPTIONAL INLET 24" x 6" TUF-TITE RISER WITH COVER 4 REQUIRED (TYP.)
CAST-A-SEAL 402 4" PVC POLYSEAL RISER WITH COVER 2 REQUIRED
2 REQUIRED
TUF-TITE
EFFLUENT
FILTER EF-6
4" OUTLET
140
CAST-A-SEAL 402
[5 1/2"]
BAFFLE BAFFLE
[63"]
1613
1601
1193
[63 1/2"]
[53"]
1346
[50"]
(TYP.)
1269
724
[28 1/2"]
74 25
SECTION A [2 7/8"] [1"]
SECTION B
SCALE:1/30 SCALE:1/30
CONCRETE: 35MPa at 28 days/5000PSI UNIT WEIGHT: 13,400 lbs DRAWN BY:
AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 6135 LITRES SEPTIC TANK
1350 IMPERIAL GALLON
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-BB6-00
DATE: WORKING CAPACITY: 6,169 LITRES TO INVERT OF OUTLET
BROOKLIN, ON A23.1 /A23.3 G30.18 Fy=400MPa
1-800-655-3430 JAN/2018 TOTAL CAPACITY: 7,192 LITRES TO UNDERSIDE OF CHAMBER LID
3213
GENERAL NOTES:
[126"]
1. UNITS ARE SEALED WITH BUTYL TAPE AT
THE JOINTS
2553
PROPER LIFTING EQUIPMENT (I.E.
[101"]
SPREADER BAR)
10M LIFTING
ANCHOR.
4 REQUIRED (TYP)
2911
6
[114 5/8"]
4" INLET OPTIONAL INLET 24" x 6" TUF-TITE 24" x 6" TUF-TITE 10M LIFTING
CAST-A-SEAL 402 4" PVC POLYSEAL RISER WITH COVER RISER WITH COVER ANCHOR
108
TUF-TITE EFFLUENT
FILTER EF-6
4" OUTLET
CAST-A-SEAL 402 BAFFLE
BAFFLE
1581
1581
[62 1/4"]
[62 1/4"]
[52"]
1321
[50"]
1270
[21 5/8"](TYP.)
76
76
2214
775
[3"](TYP.)
[3"](TYP.)
[87 1/8"]
[30 1/2"]
76 76
[3"](TYP.) [3"](TYP.)
SECTION A SECTION B
SCALE:1/40 SCALE:1/40
GENERAL NOTES:
2. DELIVERY IS MADE BY
CRANE-EQUIPPED TRUCKS
TUF-TITE
EFFLUENT 3. EXCAVATION MUST BE READY, SAFE
FILTER EF-6 AND ACCESSIBLE FOR UNLOADING
FROM THE REAR OF THE TRUCK.
[90"]
2286
4. MIN OVERHEAD CLEARANCE OF
18FT IS REQUIRED
7
10M LIFTING
4" INLET OPTIONAL INLET 24" x 6" TUF-TITE 24" x 6" TUF-TITE ANCHOR
CAST-A-SEAL 402 4" PVC POLYSEAL RISER WITH COVER RISER WITH COVER 4 REQUIRED (TYP)
2 REQUIRED
[5"]
2 REQUIRED
127
TUF-TITE
EFFLUENT
FILTER EF-6
4" OUTLET
CAST-A-SEAL 402 BAFFLE
BAFFLE
OPENING
[58"]
[58"]
1473
1473
1092
670 DIAM 4" (TYP.)
LIQUID DEPTH
1232
1181
3 REQUIRED
[48 1/2"]
76
[46 1/2"]
[26 3/8"]
76
711
[28"]
[3"](TYP.)
[3"](TYP.)
76 76
[3"](TYP.) [3"](TYP.)
SECTION A SECTION B
SCALE:1/40 SCALE:1/40
2. DELIVERY IS MADE BY
CRANE-EQUIPPED TRUCKS
TUF-TITE
EFFLUENT 3. EXCAVATION MUST BE READY, SAFE
FILTER EF-6 AND ACCESSIBLE FOR UNLOADING
FROM THE REAR OF THE TRUCK.
[90"]
2286
4. MIN OVERHEAD CLEARANCE OF
18FT IS REQUIRED
TOP VIEW
SCALE:1/40
8
CAST-A-SEAL 402 4" PVC POLYSEAL RISER WITH COVER
[5"]
2 REQUIRED
127
TUF-TITE
EFFLUENT
FILTER EF-6
4" OUTLET
CAST-A-SEAL 402 BAFFLE
BAFFLE
1295
OPENING
[66"]
[66"]
1677
1677
LIQUID DEPTH
670 DIAM 4" (TYP.)
[56"]
1423
[54"]
1372
3 REQUIRED
[26 3/8"]
76
76
686
[27"]
[3"](TYP.)
[3"](TYP.)
76 76
[3"](TYP.) [3"](TYP.)
SECTION A SECTION B
SCALE:1/40 SCALE:1/40
GENERAL NOTES:
2591
[102"]
4. MIN OVERHEAD CLEARANCE OF 18FT
IS REQUIRED
9
TUFF TITE 24" COVER TUFF TITE 24" COVER
4" INLET WITH 6"X24" RISER WITH 6"X24" RISER
CAST-A-SEAL 402 2 REQUIRED (TYP.) 2 REQUIRED (TYP.)
[5"]
[5"]
127
127
280
[11"]
OPENING
BAFFLE 4" OUTLET 305 23 4"X12"(TYP.)
CAST-A-SEAL 402 3 REQUIRED
[12"]
70
TUF-TITE
[2 3/4"]
EFFLUENT
FILTER EF-6 127
OPENING
[69"]
[69"]
1753
1753
1238
2 REQUIRED [5"] DIAM. 4"(TYP.)
LIQUID DEPTH
[56"]
1423
[53"]
1346
3 REQUIRED
87
108
108
[4 1/4"]
[4 1/4"]
[3 3/8"]
5055 2591
[199"] [102"]
SECTION A SECTION B
SCALE:1/50 SCALE:1/50
GENERAL NOTES:
2591
[102"]
4. MIN OVERHEAD CLEARANCE OF
18FT IS REQUIRED
10
108
2 REQUIRED (TYP.)
[4 1/4"]
4" OUTLET OPENING
CAST-A-SEAL 402 127 DIAM. 4" (TYP.)
864
[34"]
3 REQUIRED
[5"]
127
BAFFLE [5"]
TUF-TITE
EFFLUENT 127
[68"]
1727
1275 274
FILTER EF-6
1435
[5"]
1383
LIQUID DEPTH 2 REQUIRED [10 3/4"]
[56 1/2"]
[54 1/2"]
86
864
[34"]
108
108
[3 3/8"]
[4 1/4"]
[4 1/4"]
5055 2591
[199"] [102"]
SECTION A SECTION B
SCALE:1/50 SCALE:1/50
GENERAL NOTES:
2591
[102"]
4. MIN OVERHEAD CLEARANCE OF
18FT IS REQUIRED
11
TUFF TITE 24" COVER
4" INLET TUFF TITE 24" COVER WITH 6"X24" RISER
OPTIONAL INLET
CAST-A-SEAL 402 WITH 6"X24" RISER 2 REQUIRED (TYP.)
4" PVC POLYSEAL
108
[4 1/4"]
2 REQUIRED (TYP.)
1344 [5"]
LIQUID DEPTH
4"PVC CAP TAP CON
2096
2096
[82 1/2"]
[82 1/2"]
274
TEE GLUE TO CAP
1810
1758
[71 1/4"]
[69 1/4"]
86
108
108
[3 3/8"]
[4 1/4"]
[4 1/4"]
5055 2591
[199"] [102"]
SECTION A SECTION B
SCALE:1/50 SCALE:1/50
GENERAL NOTES:
2591
[102"]
THE TRUCK.
108
[4 1/4"]
2 REQUIRED (TYP.)
12
OPENING
4" OUTLET
DIAM. 4" (TYP.)
CAST-A-SEAL 402
3 REQUIRED
BAFFLE PL-525 EFFLUENT
FILTER
2076 127
[5"]
127
2527
2527
[99 1/2"]
[99 1/2"]
274
[88"]
2235
[86"]
2184
[10 3/4"] 127
[5"]
86
108
108
[3 3/8"]
[4 1/4"]
[4 1/4"]
5055 2591
[199"] [102"]
SECTION A SECTION B
SCALE:1/50 SCALE:1/50
GENERAL NOTES:
2591
[102"]
4. MIN OVERHEAD CLEARANCE OF 18FT IS
REQUIRED
108
2 REQUIRED (TYP.)
13
[4 1/4"]
OPENING
4" OUTLET DIAM. 4" (TYP.)
CAST-A-SEAL 402 3 REQUIRED
PL-525 EFFLUENT
FILTER
LIQUID DEPTH
127
3251
3251
[128"]
[128"]
274
2877
2826
[10 3/4"]
[113 1/4"]
[111 1/4"]
127
[5"]
86
108
108
[3 3/8"]
[4 1/4"]
[4 1/4"]
5055 2591
[199"] [102"]
SECTION A SECTION B
SCALE:1/50 SCALE:1/50
152 [120"]
152 152
[6"]
[6"] 2"X45"OPENING [6"]
[6"]
152
[6"]
152
6"x12"
OPENINGS.
2 REQ.
[88"]
2540
2236
[100"]
2743
3048
[120"]
[108"]
[44"]
1118
[6"]
152
SECTION B
24" x 12" TUF-TITE SCALE:1/60
RISER WITH COVER.
2 REQUIRED
TOP VIEW
SCALE:1/60
14
[6"]
152
PL-525
EFFLUENT
FILTER. GENERAL NOTES:
BAFFLE
4" PVC 1. UNITS ARE SEALED WITH BUTYL TAPE
POLYSEAL AT THE JOINTS
CAST-A-SEAL
964 - 4.21" 4" PVC CAP TAP CON
OD-6.9"OD TO WALL w/4" PVC 2. MOBILE CRANE REQUIRED ON SITE TO
TEE GLUE TO CAP UNLOAD THE TANK
2540
[100"]
3. ALL UNITS MUST BE HANDLED WITH
[85"]
2159
PROPER LIFTING EQUIPMENT (I.E.
[82"]
2083
SPREADER BAR)
SECTION A
SCALE:1/60
2"X45"OPENING
PL-525 EFFLUENT
FILTER
[60"]
1524
6"X12"
OPENING. 2
REQUIRED
2642
3048
[120"]
[104"]
2997
[118"]
[58"]
1473
[8"]
WITH 12"X24" RISER 2
203
REQUIRED (TYP.)
SECTION B
TOP VIEW SCALE:1/60
SCALE:1/60
15
INLET 4" PVC
POLYSEAL
7315
[288"]
203
[8"]
2997
[118"]
76
2616
2565
[103"]
2. BURIAL DEPTH= 30"
[101"]
[3"]
SECTION A
170
SCALE:1/60
[6 3/4"]
CONCRETE: 45MPa / 6,500PSI CSA APPROVED DRAWN BY:
AIR ENTRAINMENT: 6-8% WEIGHT: 50,700lbs / 23,000kg (TOP) S.RIMLAND 45500 LITRES SEPTIC
MEETS CAN/CSA-B66-00 50,700lbs / 23,000kg (BOTTOM) 10,000 IMPERIAL GALLON TANK
MANUFACTURED:
OTTAWA, ON REINFORCEMENT: MEETS G30.14-M1983 DATE:
10,000 IMPERIAL GALLON / 45,500 LITRES SEPTIC TANK
1-800-655-3430 JAN/2018
9145
[360"]
203 203 2745 203 3660
[8"] [8"] [108 1/8"] [8"] (TYP) [144 1/8"]
833
1250
PL-525 EFFLUENT
[49 1/4"]
[32 3/4"] FILTER
2 REQUIRED
3660
6" X 20" OPENING
[144 1/8"]
2 REQUIRED (TYP.)
1800
TUFF- TITE 12" X 24" TUFF- TITE 12" X 24" EZset 12" X 30" RISER
[70 7/8"]
WITH COVER WITH COVER WITH COVER
2 REQUIRED 2 REQUIRED 1 REQUIRED
SECTION B
TOP VIEW SCALE:1/30
SCALE:1/30
9145
[360"]
EZset 12" X 30" RISER
WITH COVER
1 REQUIRED
16
4" PVC
12" X 4" OPENING OUTLET
4" PVC INLET
(TYP.)
203
1047
NOTE 5
[41 1/4"]
[8"](TYP.)
GENERAL NOTES:
77
1. CONCRETE TO BE 45MPa/6,500 P.S.I.
3050
[3"]
[120 1/8"]
2670
2600
2. REINFORCEMENT TO CONFORM TO
[105 1/8"]
[102 3/8"]
CSA-G30.12-400Pa
203
SECTION A
[8"](TYP.)
SCALE:1/30
203
[8"](TYP.)
[71"]
1804
838 PL-525 EFFLUENT
[33"] FILTER. 2 REQ.
3660
152
[144 1/8"]
[6"](TYP.) 6"x 20"
OPENING
TUFF- TITE 12" X 24" TUFF- TITE 12" X 24" (TYP.)
EZset 12" X 30" RISER
WITH COVER WITH COVER
WITH COVER
[71"]
1804
2 REQUIRED 2 REQUIRED
1 REQUIRED 203
[8"](TYP.)
17
SCALE:1/30 SCALE:1/30
[8"](TYP.)
9145
CAST-A-SEAL [360"]
964 - 4.21" EZset 12" X 30" RISER
OD-6.9"OD WITH COVER
1 REQUIRED
4" PVC
OUTLET
NOTE 5
GENERAL NOTES:
3607
[142"]
77
3230
3150
[124"]
[127 1/8"]
CSA-G30.12-400Pa
4. REINFORCEMENT
914
[36"]
[42"]
1067
5. ALL UNITS MUST BE HANDLED WITH
PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)
TOP VIEW
SCALE:1/16
18
3" DIAL CORD SEAL
76
[3"]
4" INLET PVC 4" OUTLET PVC
POLYSEAL POLYSEAL
889
[35"]
737
[29"]
597
584
[23"]
[23 1/2"]
51
[2"]
SECTION A
SCALE:1/16
76
ACCESSIBLE FOR UNLOADING FROM THE
REAR OF THE TRUCK.
[3"] (TYP.)
4. MIN OVERHEAD CLEARANCE OF 18FT IS
REQUIRED
[50"]
1270
6. MAXIMUM BURIAL DEPTH = 1 METRE IN
FIRM SOIL AWAY FROM ANY VEHICULAR
TRAFFIC
4" INLET 2" OUTLET
CAST-A-SEAL 402 CAST-A-SEAL 402
*WILL BE CONVERTING TO A 2" CAST-A-SEAL OUTLET FOR 2018*
76
[3"] (TYP.)
680 & 1365 LITRES TOP VIEW 24" x 6" TUF-TITE
RISER WITH COVER
SCALE: 1/20
76
19
[3"]
24" x 6" TUF-TITE
RISER WITH COVER
1359
[53 1/2"]
[45"]
1143
[43"]
1092
838
[33"]
621
594
76
[24 1/2"]
[23 1/2"]
[3"] (TYP.)
88 1346
[3 1/2"] 1346
[53"]
[53"]
680 LITRES SECTION A 1365 LITRES SECTION A
SCALE: 1/20 SCALE: 1/20
2. DELIVERY IS MADE BY
CRANE-EQUIPPED TRUCKS
[48"]
1219
4. MIN OVERHEAD CLEARANCE OF 18FT
IS REQUIRED
3" DIAMETER 24" x 6" TUF-TITE RISER 24" x 6" TUF-TITE RISER 3" DIAMETER
CORD SEAL WITH COVER. 2 REQUIRED WITH COVER. 2 REQUIRED CORD SEAL
2386 1142
[94"] [45"]
4" INLET
CAST-A-SEAL 402
20
76
[3"]
4" INLET
2" OUTLET CAST-A-SEAL 402
CAST-A-SEAL 402
[64"]
[64"]
1625
1625
[53"]
[53"]
1346
1346
[51"]
1295
737
[29"]
813
[32"]
76 76 76
76
[3"]
[3"] [3"] [3"]
2438 1219
[96"] [48"]
SECTION A SECTION B
SCALE:1/30 SCALE:1/30
[66"]
1679
4. MIN OVERHEAD CLEARANCE OF 18FT IS
REQUIRED
21
OPTIONAL INLET
4" PVC POLYSEAL
2" OUTLET
CAST-A-SEAL 402
[59"]
1498
[56"]
1422
[46"]
1167
[44"]
1117
635
[25"]
711
[28"]
76
[3"]
76 76 76
[3"]
76
[3"] [3"] [3"]
2543 1679
[100"] [66"]
SECTION A SECTION B
SCALE:1/30 SCALE:1/30
CONCRETE: 35MPa at 28 days/5000PSI UNIT WEIGHT: 6,940lbs / 3,147kg DRAWN BY:
AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 3600 LITRES LOW HEIGHT
800 IMPERIAL GALLON PUMP TANK
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-B66
BROOKLIN, ON DATE:
A23.1 /A23.3 G30.18 Fy=400MPa
JAN/2018 800 IMPERIAL GALLON / 3,600 LITRES
1-800-655-3430
2540
[100"]
3" DIAMETER GENERAL NOTES:
CORD SEAL
1. UNITS ARE SEALED WITH BUTYL TAPE AT
THE JOINTS
[54"]
1372
4. MIN OVERHEAD CLEARANCE OF 18FT IS
REQUIRED
22
4" INLET
CAST-A-SEAL 402
OPTIONAL INLET
4" PVC POLYSEAL 2" OUTLET
CAST-A-SEAL 402
[70"]
1778
[67"]
1702
[58"]
1470
[56"]
1422
775
851
[30 1/2"]
[33 1/2"]
76
[3"]
76 76 76
[3"]
76
[3"] [3"] [3"]
2540 1372
[100"] [54"]
SECTION A SECTION B
SCALE:1/30 SCALE:1/30
CONCRETE: 35MPa at 28 days / 5000PSI UNIT WEIGHT: 6,490lbs / 2,943kg DRAWN BY:
AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 3600 LITRES PUMP TANK
800 IMPERIAL GALLON
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-B66
BROOKLIN, ON DATE:
A23.1 /A23.3 G30.18 Fy=400MPa 800 IMPERIAL GALLON / 3,600 LITRES
1-800-655-3430 JAN / 2018
2972
[117"]
GENERAL NOTES:
[86"]
2184
5. ALL UNITS MUST BE HANDLED WITH
PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)
3" DIAMETER 24" x 6" TUF-TITE RISER 24" x 6" TUF-TITE RISER 3" DIAMETER
CORD SEAL WITH COVER. 2 REQUIRED WITH COVER. 2 REQUIRED CORD SEAL
2870 2082
23
[113"] [82"]
4" INLET
CAST-A-SEAL 402
OPTIONAL INLET
4" PVC POLYSEAL 2" OUTLET
CAST-A-SEAL 402
[54"]
1371
[51"]
1295
[42"]
1067
[40"]
1016
648
[25 1/2"]
76
76
[3"]
[3"]
76 76
[3"] (TYP.) SECTION A [3"] SECTION B
SCALE:1/30 SCALE:1/30
CONCRETE: 35MPa at 28 days / 5000PSI UNIT WEIGHT: 11,620 lbs DRAWN BY:
CPA CERTIFIED S.RIMLAND
LOW HEIGHT
AIR ENTRAINMENT: 6-8% 4500 LITRES
1000 IMPERIAL GALLON PUMP TANK
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-BB6-00
BROOKLIN, ON DATE:
A23.1 /A23.3 G30.18 Fy=400MPa
JAN/2018 1000 IMPERIAL GALLON / 4,500 LITRES
1-800-655-3430
2540
[100"]
GENERAL NOTES:
[66"]
1676
REQUIRED
3" DIAMETER 24" x 6" TUF-TITE RISER WITH 24" x 6" TUF-TITE RISER WITH 3" DIAMETER
2450 CORD SEAL COVER. 2 REQUIRED COVER. 2 REQUIRED 1586 CORD SEAL
24
[96 1/2"] [62 1/2"]
76
4" INLET
CAST-A-SEAL 402
[3"](TYP.)
OPTIONAL INLET
4" PVC POLYSEAL 2" OUTLET
CAST-A-SEAL 402
[69"]
1752
[66"]
[66"]
1676
1676
[58"]
1472
[56"]
1420
838
[33"]
76
76
[3"]
[3"]
76 76
[3"] (TYP.) [3"](TYP.)
SECTION A SECTION B
SCALE:1/30 SCALE:1/30
2290
PROPER LIFTING EQUIPMENT (I.E.
[90 1/8"]
SPREADER BAR)
25
2 REQUIRED
2" OUTLET
140
CAST-A-SEAL 402
[5 1/2"]
[63"]
1613
1601
[63 1/2"]
[53"]
1346
[50"]
1269
74 25
SECTION A [2 7/8"] [1"]
SECTION B
SCALE:1/30 SCALE:1/30
CONCRETE: 35MPa at 28 days/5000PSI UNIT WEIGHT: 13,400 lbs DRAWN BY:
AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 6135 LITRES PUMP TANK
1350 IMPERIAL GALLON
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-BB6-00
BROOKLIN, ON DATE:
A23.1 /A23.3 G30.18 Fy=400MPa
JAN/2018
1350 IMPERIAL GALLON / 6,135 LITRES
1-800-655-3430
3213
GENERAL NOTES:
[126"] 3" DIAMETER
CORD SEAL 1. UNITS ARE SEALED WITH BUTYL TAPE AT
THE JOINTS
2553
PROPER LIFTING EQUIPMENT (I.E.
[101"]
SPREADER BAR)
26
3" DIAMETER
CORD SEAL
2911
24" x 6" TUF-TITE 10M LIFTING
[114 5/8"] RISER WITH COVER ANCHOR
2 REQUIRED 4 REQUIRED (TYP)
4" INLET OPTIONAL INLET 24" x 6" TUF-TITE
CAST-A-SEAL 402 4" PVC POLYSEAL RISER WITH COVER
2 REQUIRED
2" OUTLET
CAST-A-SEAL 402
108
[4 1/4"]
2214
1581
1581
[87 1/8"]
[62 1/4"]
[62 1/4"]
[52"]
1321
[50"]
1270
76
76
[3"](TYP.)
[3"](TYP.)
76 76
[3"](TYP.) [3"](TYP.)
SECTION A SECTION B
SCALE:1/40 SCALE:1/40
GENERAL NOTES:
[90"]
2286
4. MIN OVERHEAD CLEARANCE OF
18FT IS REQUIRED
10M LIFTING
4" INLET 3" DIAMETER 24" x 6" TUF-TITE ANCHOR
24" x 6" TUF-TITE
CAST-A-SEAL 402 CORD SEAL RISER WITH COVER 4 REQUIRED (TYP)
27
RISER WITH COVER
2 REQUIRED
2 REQUIRED
[5"]
127
OPTIONAL INLET
4" PVC POLYSEAL 2" OUTLET
CAST-A-SEAL 402
[58"]
[58"]
1473
1473
1232
1181
[48 1/2"]
76
[46 1/2"]
76
[3"](TYP.)
[3"](TYP.)
76 76
[3"](TYP.) [3"](TYP.)
SECTION A SECTION B
SCALE:1/40 SCALE:1/40
2. DELIVERY IS MADE BY
CRANE-EQUIPPED TRUCKS
[90"]
2286
PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)
[60"]
1524
IN FIRM SOIL AWAY FROM ANY
VEHICULAR TRAFFIC
10M LIFTING
ANCHOR.
4 REQUIRED (TYP)
28
2 REQUIRED SCALE:1/40
[5"]
2 REQUIRED
127
OPTIONAL INLET
4" OUTLET PVC
4" PVC POLYSEAL
POLYSEAL
4" INLET
*9,000 LITRES TO ROOF*
CAST-A-SEAL 402
[58"]
[58"]
1473
1472
[48"]
1219
[46"]
1168
76
76
[3"](TYP.)
[3"](TYP.)
76 76
[3"](TYP.) [3"](TYP.)
SECTION A SECTION B
SCALE:1/40 SCALE:1/40
[90"]
2286
4. MIN OVERHEAD CLEARANCE OF
18FT IS REQUIRED
TOP VIEW
SCALE:1/40
3" DIAMETER
CORD SEAL
24" x 6" TUF-TITE 3" DIAMETER 24" x 6" TUF-TITE 10M LIFTING
4" INLET OPTIONAL INLET RISER WITH COVER CORD SEAL RISER WITH COVER ANCHOR
CAST-A-SEAL 402 4" PVC POLYSEAL 2 REQUIRED 2 REQUIRED 4 REQUIRED (TYP)
[5"]
127
29
4" OUTLET PVC
POLYSEAL
4" INLET
CAST-A-SEAL 402
[66"]
[66"]
1677
1677
[56"]
1423
[54"]
1372
76
76
[3"](TYP.)
[3"](TYP.)
76 76
[3"](TYP.) [3"](TYP.)
SECTION A SECTION B
SCALE:1/40 SCALE:1/40
GENERAL NOTES:
2591
[102"]
4. MIN OVERHEAD CLEARANCE OF
18FT IS REQUIRED
30
TUFF TITE 24" COVER TUFF TITE 24" COVER 3" DIAMETER
4" INLET WITH 12"X24" RISER 3" DIAMETER WITH 12"X24" RISER CORD SEAL
CAST-A-SEAL 402 2 REQUIRED (TYP.) CORD SEAL 2 REQUIRED (TYP.)
[5"]
127
OPTIONAL INLET
4" OUTLET PVC
4" PVC POLYSEAL
POLYSEAL
127 4" INLET
CAST-A-SEAL 402
[5"]
[60"]
[59"]
1524
1499
[47"]
1194
[45"]
1143
87
108
108
[4 1/4"]
[4 1/4"]
[3 3/8"]
5055 2591
[199"] [102"]
SECTION A SECTION B
SCALE:1/50 SCALE:1/50
GENERAL NOTES:
2591
[102"]
4. MIN OVERHEAD CLEARANCE OF
18FT IS REQUIRED
4" INLET TUFF TITE 24" COVER 3" DIAMETER TUFF TITE 24" COVER 3" DIAMETER
CAST-A-SEAL 402 WITH 6"X24" RISER CORD SEAL WITH 6"X24" RISER CORD SEAL
2 REQUIRED (TYP.) 2 REQUIRED (TYP.)
31
108
[4 1/4"]
OPTIONAL INLET
4" OUTLET
4" PVC POLYSEAL
PVC POLYSEAL
864
[34"]
4" INLET
CAST-A-SEAL 402
127
[68"]
1727
1435
[5"]
1383
[56 1/2"]
[54 1/2"]
86
864
[34"]
108
108
[3 3/8"]
[4 1/4"]
[4 1/4"]
5055 2591
[199"] [102"]
SECTION A SECTION B
SCALE:1/50 SCALE:1/50
CONCRETE: 35MPa at 28 days / 5000PSI WEIGHT: 26,142lbs / 11,857kg DRAWN BY: SINGLE
AIR ENTRAINMENT: 5-8% S.RIMLAND 13650 LITRES
CPA CERTIFIED 3,000 IMPERIAL GALLON CHAMBER
MANUFACTURED: MEETS CAN/CSA-B66-00
BROOKLIN, ON DATE:
REINFORCEMENT: STEEL TO CSA CAN
3,000 IMPERIAL GALLON / 13,650 LITRES SINGLE CHAMBER
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018
5055
[199"]
GENERAL NOTES:
2591
[102"]
4. MIN OVERHEAD CLEARANCE OF
18FT IS REQUIRED
32
OPTIONAL INLET 3" DIAMETER TUFF TITE 24" COVER TUFF TITE 24" COVER 3" DIAMETER
4" INLET 4" PVC POLYSEAL CORD SEAL WITH 6"X24" RISER WITH 6"X24" RISER CORD SEAL
CAST-A-SEAL 402 2 REQUIRED (TYP.) 2 REQUIRED (TYP.)
108
[4 1/4"]
4" OUTLET PVC
POLYSEAL
4" INLET
CAST-A-SEAL 402
2096
2096
127
[82 1/2"]
[82 1/2"]
1810
1759
[71 1/4"]
[69 1/4"]
[5"]
86
108
108
[3 3/8"]
[4 1/4"]
[4 1/4"]
5055 2591
[199"] [102"]
SECTION A SECTION B
SCALE:1/50 SCALE:1/50
GENERAL NOTES:
2591
[102"]
THE TRUCK.
4" INLET OPTIONAL INLET 3" DIAMETER TUFF TITE 24" COVER TUFF TITE 24" COVER 3" DIAMETER
CAST-A-SEAL 402 4" PVC POLYSEAL CORD SEAL WITH 6"X24" RISER WITH 6"X24" RISER CORD SEAL
2 REQUIRED (TYP.) 2 REQUIRED (TYP.)
108
[4 1/4"]
33
4" OUTLET PVC
POLYSEAL
4" INLET
CAST-A-SEAL 402
2527
2527
[99 1/2"]
[99 1/2"]
[88"]
2235
[86"]
2184
127
[5"]
86
108
108
[3 3/8"]
[4 1/4"]
[4 1/4"]
5055 2591
[199"] [102"]
SECTION A SECTION B
SCALE:1/50 SCALE:1/50
GENERAL NOTES:
2591
[102"]
4. MIN OVERHEAD CLEARANCE OF 18FT IS
REQUIRED
3" DIAMETER TUFF TITE 24" COVER TUFF TITE 24" COVER 3" DIAMETER
4" INLET OPTIONAL INLET CORD SEAL WITH 6"X24" RISER WITH 6"X24" RISER CORD SEAL
CAST-A-SEAL 402 4" PVC POLYSEAL 2 REQUIRED (TYP.) 2 REQUIRED (TYP.)
108
34
[4 1/4"]
4" OUTLET PVC
POLYSEAL
4" INLET
CAST-A-SEAL 402
3251
3251
[128"]
[128"]
2877
2826
[113 1/4"]
[111 1/4"]
127
[5"]
86
108
108
[3 3/8"]
[4 1/4"]
[4 1/4"]
5055 2591
[199"] [102"]
SECTION A SECTION B
SCALE:1/50 SCALE:1/50
152 [120"]
152 152
[6"]
3" DIAMETER [6"] 2"X45"OPENING [6"]
CORD SEAL
[6"]
152
[6"]
152
6"x12"
OPENINGS.
2 REQ.
2540
[100"]
3048
[120"]
[44"]
1118
24"X24"
[6"]
152
(600mmX600mm) SECTION B
24" x 12" TUF-TITE KNOCKOUT PANEL. SCALE:1/60
TOP VIEW RISER WITH COVER.
SCALE:1/60 2 REQUIRED
35
[6"]
152
4" OUTLET PVC
GENERAL NOTES:
POLYSEAL
BAFFLE
1. UNITS ARE SEALED WITH BUTYL TAPE
CAST-A-SEAL AT THE JOINTS
964 - 4.21"
OD-6.9"OD 2. MOBILE CRANE REQUIRED ON SITE TO
UNLOAD THE TANK
2540
[100"]
3. ALL UNITS MUST BE HANDLED WITH
[85"]
2159
PROPER LIFTING EQUIPMENT
[82"]
2083
SECTION A
SCALE:1/60
2"X45"OPENING
[60"]
1524
6"X12"
OPENING. 2
REQUIRED
2642
3048
[120"]
[104"]
2997
[118"]
[58"]
1473
[8"]
WITH 12"X24" RISER 2
203
(600mmX600mm)
REQUIRED (TYP.)
SECTION B KNOCKOUT PANEL.
TOP VIEW SCALE:1/60
SCALE:1/60
36
INLET 4" PVC
POLYSEAL
7315
[288"]
203
[8"]
GENERAL NOTES:
2997
[118"]
76
2616
2565
[103"]
2. BURIAL DEPTH= 30"
[101"]
[3"]
SECTION A
170
SCALE:1/60
[6 3/4"]
CONCRETE: 45MPa / 6,500PSI CSA APPROVED DRAWN BY:
AIR ENTRAINMENT: 6-8% WEIGHT: 50,700lbs / 23,000kg (TOP) S.RIMLAND 45500 LITRES SINGLE
MEETS CAN/CSA-B66-00 50,700lbs / 23,000kg (BOTTOM) 10,000 IMPERIAL GALLON CHAMBER
MANUFACTURED:
OTTAWA, ON REINFORCEMENT: MEETS G30.14-M1983 DATE:
10,000 IMPERIAL GALLON / 45,500 LITRES SINGLE CHAMBER TANK
1-800-655-3430 JAN/2018
9145 TUFF- TITE 12" X 24"
[360"] WITH COVER
203 203 2745 203 3 REQUIRED
3660
[8"] [8"] [108 1/8"] [8"] (TYP) [144 1/8"]
1250
(TYP.)
TUFF- TITE 12" X 24"
[49 1/4"]
WITH COVER
3 REQUIRED
6"X20"
3660
OPENING. 2
[144 1/8"]
REQUIRED
2' X 2' OPENING
(TYP.)
838
1800
[70 7/8"]
[33"]
SECTION B
TOP VIEW SCALE:1/30
SCALE:1/30
9145
TUFF- TITE 12" X 24" [360"] 447
WITH COVER
[17 5/8"]
37
3 REQUIRED
4" PVC POLYSEAL
12" X 4" OPENING
CAST-A-SEAL 964 -
(TYP.)
4.21" OD-6.9"OD
203
*16,000 IMPERIAL GALLON /
[8"](TYP.)
72,700 LITRES TO ROOF
GENERAL NOTES:
77
1. CONCRETE TO BE 45MPa/6,500 P.S.I.
3050
[3"]
[120 1/8"]
2671
2601
2. REINFORCEMENT TO CONFORM TO
[105 1/8"]
CSA-G30.12-400Pa
[102 3/8"]
3. REINFORCEMENT
203
203 TANK: 20M @ 150 O/C BOTH WAYS
610
[24"]
[8"](TYP.)
[8"] LID: 20M @ 150 O/C BOTH WAYS
SECTION A
203
SCALE:1/30
[8"](TYP.)
CONCRETE: 45MPa / 6,500PSI CPA CERTIFIED DRAWN BY:
AIR ENTRAINMENT: 6-8% S.RIMLAND 72700 LITRES SINGLE
WEIGHT: 63,150lbs/28,645kg (TOP) 16,000 IMPERIAL GALLON CHAMBER
MANUFACTURED: MEETS CAN/CSA-B66-00
81,625lbs/37,025kg (BOTTOM)
OTTAWA, ON REINFORCEMENT : STEEL TO CSA CAN DATE:
16,000 IMPERIAL GALLON / 72,700 LITRES SINGLE CHAMBER TANK
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018
9145 3660
[360"] [144 1/8"]
203 203 2745 203
[8"] [8"] [108 1/8"] [8"] (TYP)
203
[8"](TYP.)
838
[71"]
1804
TUFF- TITE 12" X 24"
WITH COVER [33"]
6"X20"
3 REQUIRED OPENING. 2
REQUIRED
3660
152
[144 1/8"]
[6"](TYP.)
2'x2' OPENING
(TYP.)
[71"]
1804 203
[8"](TYP.)
SCALE:1/30 SCALE:1/30
[8"](TYP.)
38
9145
[360"]
TUFF- TITE 12" X 24"
4" PVC
WITH COVER
INLET
3 REQUIRED
4" PVC
4" PVC INLET OUTLET
GENERAL NOTES:
3607
[142"]
77
3230
3150
[124"]
[127 1/8"]
CSA-G30.12-400Pa
KNOCKOUT 4. REINFORCEMENT
PANEL
610
[24"]
SECTION A
SCALE:1/30
GENERAL NOTES:
2591
[102"]
4. MIN OVERHEAD CLEARANCE OF 18FT
IS REQUIRED
39
TUFF TITE 24" COVER DRY HYDRANT
4" INLET 100mm VENT
WITH 12"X24" RISER DIXON-dfh 9140-600
610
[24"]
108
CAST-A-SEAL 402
[4 1/4"]
2 REQUIRED (TYP.)
4" INLET
CAST-A-SEAL
402 4" PVC PIPE
2406
2527
2527
[94 3/4"]
[99 1/2"]
[99 1/2"]
[88"]
2235
127
[5"]
86
108
108
[3 3/8"]
[4 1/4"]
[4 1/4"]
5055 2591
[199"] [102"]
SECTION A SECTION B
SCALE:1/50 SCALE:1/50
108
4" INLET
[4 1/4"]
610
[24"]
4" INLET CAST-A-SEAL 402
175mmØ OPENING
CAST-A-SEAL
FOR DRY HYDRANT
402
DIXON-dfh 9140-600
TANK 2
4" PVC PIPE
TANK 2
2406
2527
100mm VENT
[94 3/4"]
[99 1/2"]
[88"]
2235
NOTE 1
108
1352 2351 1352
[4 1/4"]
[53 1/4"] [92 1/2"] [53 1/4"]
5055
1352
127 [199"] CAS 603 FOR
[5"]
128
[53 1/4"] 8" I.D. SDR 35
410
[5"]
[16 1/8"]
SECTION A
SCALE:1/60
CAS 603 FOR
175mmØ OPENING
8" I.D. SDR 35
FOR DRY HYDRANT
100mm VENT
12" X 24" TUFF-TITE DIXON-dfh 9140-600
WITH COVER 2
100mm VENT REQ. PER UNIT
TANK 1
2591
[102"]
12" X 24" TUFF-TITE
WITH COVER 2
REQ. PER UNIT 100mm VENT
40
4" INLET
CAST-A-SEAL 402
TANK 1 TANK 2
[5"]
128
2527
TOP VIEW 127
[99 1/2"]
SCALE:1/60 [5"]
86
[3 3/8"]
108
[4 1/4"]
GENERAL NOTES:
4. EXCAVATION MUST BE READY, SAFE AND ACCESSIBLE FOR UNLOADING FROM THE REAR OF THE TRUCK.
6. MAXIMUM BURIAL DEPTH = 1 METRE IN FIRM SOIL AWAY FROM ANY VEHICULAR TRAFFIC
GENERAL NOTES:
2591
[102"]
THE TRUCK.
41
4" INLET
WITH 12"X24" RISER
610
[24"]
108
CAST-A-SEAL 402
[4 1/4"]
2 REQUIRED (TYP.)
3067
127
3188
3188
[120 3/4"]
[125 1/2"]
[125 1/2"]
[5"]
2896
[114"]
86
[3 3/8"]
108
108
[4 1/4"]
[4 1/4"]
SECTION A SECTION B
SCALE:1/50 SCALE:1/50
*SINGLE FIRE WATER TANK*
CONCRETE: 35MPa/5000PSI WEIGHT: 40,905lbs / 18,555kg DRAWN BY:
AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 30000 LITRES
6600 IMPERIAL GALLON
MANUFACTURED: MEETS CAN/CSA-B66-00
BROOKLIN, ON DATE:
REINFORCEMENT: STEEL TO CSA CAN TOTAL CAPACITY: 33,918 LITRES TO UNDERSIDE OF CHAMBER LID
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018
5055
[199"]
108
4" PVC
[4 1/4"]
610
[24"]
4" INLET INLET
CAST-A-SEAL 175mmØ OPENING
402 FOR DRY HYDRANT
DIXON-dfh 9140-600
TANK 2
4" PVC PIPE
TANK 2
100mm VENT
3188
3188
2896
[125 1/2"]
[125 1/2"]
[114"]
1352 2351 1352 NOTE 1
[53 1/4"] [92 1/2"] [53 1/4"]
5055
108
[4 1/4"]
127 [199"]
[5"]
128
[5"]
1352
CAS 603 FOR
410
[53 1/4"] 8" I.D. SDR 35
[16 1/8"]
CAS 603 FOR
8" I.D. SDR 35 SECTION A
SCALE:1/60
2591
TANK 1 100mm VENT
[102"]
DRY HYDRANT
DIXON-dfh 9140-600
100mm VENT 12" X 24" TUFF-TITE
12" X 24" TUFF-TITE WITH COVER
WITH COVER
2 REQ. PER UNIT 2 REQ. PER UNIT
42
[5"]
128
4" INLET
TOP VIEW CAST-A-SEAL
SCALE:1/60 402
3188
1. CAS 603- CAST CLOSE AS POSSIBLE TO THE BOTTOM OF TANK
127
[125 1/2"]
2. UNITS ARE SEALED WITH BUTYL TAPE AT THE JOINTS [5"]
6. ALL UNITS MUST BE HANDLED WITH PROPER LIFTING EQUIPMENT (I.E. 2591
SPREADER BAR)
[102"] SECTION B
6. MAXIMUM BURIAL DEPTH = 1 METRE IN FIRM SOIL AWAY FROM ANY SCALE:1/60
VEHICULAR TRAFFIC
*2-NESTED FIRE WATER TANKS*
CONCRETE: 35MPa/5000PSI WEIGHT: 40,905lbs / 18,555kg DRAWN BY:
AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 30000 LITRES
6600 IMPERIAL GALLON
MANUFACTURED: MEETS CAN/CSA-B66-00
DATE: TOTAL CAPACITY: 33,918 LITRES TO UNDERSIDE OF CHAMBER LID
BROOKLIN, ON REINFORCEMENT: STEEL TO CSA CAN
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018
PER TANK
7315
203 [288"] 203
[8"] [8"]
175mmØ OPENING
FOR DRY HYDRANT
DIXON-dfh 9140-600
GENERAL NOTES:
2642
3048
[120"]
[104"]
2. MAXIMUM BURIAL DEPTH = 1 METRE IN
FIRM SOIL AWAY FROM ANY VEHICULAR
100mm VENT TRAFFIC
[8"]
203
WITH 12"X24" RISER 2
REQUIRED (TYP.)
TOP VIEW
SCALE:1/60
DRY HYDRANT 100mm VENT
DIXON-dfh 9140-600
43
4" INLET
CAST-A-SEAL 402 7315 3048
[288"] [120"]
610
[24"]
[60"]
1524
2997
2997
[118"]
[118"]
[110 1/4"]
2616
[103"]
[58"]
1473
SECTION A SECTION B
170
[6 3/4"]
SCALE:1/60 SCALE:1/60
4" INLET
175mmØ OPENING
CAST-A-SEAL 402
FOR DRY HYDRANT
DIXON-dfh 9140-600
TANK 1
TANK 1
2799
2997
100mm VENT
[118"]
[110 1/4"]
2616
[103"]
NOTE 1
410
[16 1/8"]
170
[6 3/4"]
1352 4611 1352
[53 1/4"] [181 1/2"] [53 1/4"]
1352
CAS 603 FOR
[53 1/4"] 8" I.D. SDR 35
SECTION A
CAS 603 FOR SCALE:1/80
8" I.D. SDR 35
3048
TANK 2
[120"]
12" X 24" TUFF-TITE 100mm VENT DRY HYDRANT
WITH COVER DIXON-dfh 9140-600
[8"]
203
100mm VENT 3048
2 REQ. PER TANK
[120"]
44
TOP VIEW
SCALE:1/80
4" PVC PIPE
[60"]
1524
GENERAL NOTES:
206
[71"]
[33"] FOR DRY HYDRANT
1804
TUFF- TITE 12" X 24" DIXON-dfh 9140-600
[8 1/8"](TYP.)
WITH COVER 6"X20"
3 REQUIRED OPENING. 2
REQUIRED
3660
152
[144 1/8"]
[6"](TYP.)
2'x2' OPENING
[71"] (TYP.)
100mm VENT 1803 203
[8"](TYP.)
SCALE:1/60 SCALE:1/60
[8"](TYP.)
45
9145
[360"]
TUFF- TITE 12" X 24"
4" PVC
WITH COVER
610
[24"]
INLET
3 REQUIRED
GENERAL NOTES:
3391
3607
[142"]
[133 1/2"]
77
3230
[3"] 2. REINFORCEMENT TO CONFORM TO
[127 1/8"]
CSA-G30.12-400Pa
KNOCKOUT 4. REINFORCEMENT
PANEL
610
[24"]
SECTION A
SCALE:1/60 *SINGLE FIRE WATER TANK*
CONCRETE: 45MPa / 6,500PSI CPA CERTIFIED DRAWN BY:
AIR ENTRAINMENT: 6-8% WEIGHT: 77,100lbs/34,970kg (TOP) S.RIMLAND 90900 LITRES
20000 IMPERIAL GALLON
MANUFACTURED: MEETS CAN/CSA-B66-00 77,700lbs/35,244kg (BOTTOM)
OTTAWA, ON REINFORCEMENT : STEEL TO CSA CAN DATE:
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018 20,000 IMPERIAL GALLON / 91,000 LITRES
9145 9145
[360"] [360"]
203 203 2745 203
[8"] [8"] [108 1/8"] [8"]
610
[24"]
175mmØ OPENING
FOR DRY HYDRANT
4" PVC DIXON-dfh 9140-600
INLET
TANK 1
KNOCKOUT
TANK 1 PANEL
3391
3607
[142"]
77
[133 1/2"]
3230
[3"]
[127 1/8"]
838 NOTE 1
410
[33"] 100mm VENT
[16 1/8"]
610
1352 6440 1352
1352 [24"] CAS 603 FOR
[53 1/4"] 8" I.D. SDR 35
[53 1/4"] [253 1/2"] [53 1/4"] SECTION A
SCALE:1/90
TANK 2
3660
[144 1/8"]
3660
12" X 24" TUFF-TITE [144 1/8"]
100mm VENT 100mm VENT
WITH COVER 175mmØ OPENING
[8"]
203
46
3 REQ. PER TANK FOR DRY HYDRANT
DIXON-dfh 9140-600
TOP VIEW
12"x 4" OPENING
SCALE:1/90 4" PVC PIPE (TYP.)
TANK 1 TANK 2
GENERAL NOTES:
3607
[142"]
6"X20"
1. CAS 603 - CAST CLOSE AS POSSIBLE TO THE BOTTOM OF THE TANK 2'x2' OPENING OPENING. 2
(TYP.) REQUIRED
2. CONCRETE TO BE 45MPa/6,500 P.S.I.
5. REINFORCEMENT
SECTION B
TANK: 20M @ 150 O/C BOTH WAYS SCALE:1/90
LID: 20M @ 150 O/C BOTH WAYS
GENERAL NOTES:
254
[10"]
1. UNITS ARE SEALED WITH BUTYL TAPE AT
THE JOINTS
508
[20"]
429
2. DELIVERY IS MADE BY CRANE-EQUIPPED
[16 7/8"]
TRUCKS
214
6" OPENING
FOR VENT 4. MIN OVERHEAD CLEARANCE OF 18FT IS
2 REQ. REQUIRED
SEE DETAIL 1
[86"]
2184
537
108
TOILET RISER 5. ALL UNITS MUST BE HANDLED WITH
[21 1/8"]
OPENING PROPER LIFTING EQUIPMENT (I.E.
2 REQ. SPREADER BAR)
214
6. MAXIMUM BURIAL DEPTH = 1 METRE IN
47
TOP VIEW
SCALE:1/30
2870 2082
[113"] [82"]
76
[3"]
[51"]
1295
648
[25 1/2"]
76
76
[3"]
[3"]
76 76
[3"] (TYP.) SECTION A [3"] SECTION B
SCALE:1/30 SCALE:1/30
CONCRETE: 35MPa at 28 days / 5000PSI UNIT WEIGHT: 11,620 lbs DRAWN BY:
AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND PRIVY 1000 LOW WOOD
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN
BROOKLIN, ON DATE:
A23.1 /A23.3 G30.18 Fy=400MPa
FEB/2018 1000 IMPERIAL GALLON / 4,500 LITRES
1-800-655-3430
5055
[199"]
572 1182
[22 1/2"] SEE DETAIL 1 [46 1/2"]
305 TOILET RISER OPENING 864 GENERAL NOTES:
2 REQ.
[12"] [34"]
1. UNITS ARE SEALED WITH BUTYL
TAPE AT THE JOINTS
305
305
[12"]
[12"]
521
521
2. DELIVERY IS MADE BY
[20 1/2"]
[20 1/2"]
CRANE-EQUIPPED TRUCKS
2591
[102"]
18FT IS REQUIRED
214
5. ALL UNITS MUST BE HANDLED WITH
[8 7/16"]
PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)
537
108
6. MAXIMUM BURIAL DEPTH = 1 METRE
[4 1/4"]
[21 1/8"]
IN FIRM SOIL AWAY FROM ANY
VEHICULAR TRAFFIC
214
[8 7/16"]
R2
[R 14
8
7/
16
TOP VIEW "]
48
TUFF TITE 12" COVER TUFF TITE 12" COVER
WITH 12"X12" RISER WITH 12"X12" RISER
[5"]
127
127
[5"]
[59"]
[59"]
1499
1499
87
108
108
[4 1/4"]
[4 1/4"]
[3 3/8"]
5055 2591
[199"] [102"]
SECTION A SECTION B
SCALE:1/50 SCALE:1/50
WOOD
[6"]
152
STRUCTURE
407
[16"]
529
529
[20 7/8"]
[20 7/8"]
50
1339
[52 3/4"]
356mmØ OPENING 356mmØ OPENING 400
[2"] FOR VENT FOR VENT
2 REQUIRED 2 REQUIRED [15 3/4"]
372mmØ HOLE IN 372mmØ HOLE IN
CONC. SLAB TOP CONC. SLAB TOP
[59"]
1499
2591
FOR TOILET FOR TOILET
[102"]
2 REQUIRED 2 REQUIRED
WOOD
1250
[49 1/4"]
STRUCTURE
[4"]
102
[6"]
102
152
[4"] SECTION B
SCALE:1/50
102
[4"] 372
[14 5/8"]
TOP VIEW
372mmØ HOLE IN NOTCH TOILET
SCALE:1/50 CONC. SLAB TOP RISER TO
FOR TOILET ACCOMMODATE
49
2 REQUIRED 2-STAINLESS
124 124 124 STEEL BARS
124
4876
124
[192"]
50
124
550 1274 542 1274 550 686 CAST IN PLACE BARS CAST IN PLACE BARS
EQUALLY SPACED EQUALLY SPACED
[21 5/8"] [50 1/8"] [21 3/8"] [50 1/8"] [21 5/8"] [27"] 12" x 16" TUFF-TITE
ON CENTER ON CENTER
IN OPENING IN OPENING
RISER WITH COVER
WOOD
451
STRUCTURE
[17 3/4"]
[6"]
152
[71"]
1803
2. EXCAVATION MUST BE READY, SAFE AND ACCESSIBLE FOR UNLOADING FROM THE REAR
OF THE TRUCK.
4. ALL UNITS MUST BE HANDLED WITH PROPER LIFTING EQUIPMENT (I.E. SPREADER BAR)
[6"]
152
[21 5/8"] [50 1/8"] [21 3/8"] [50 1/8"] [21 5/8"] [27"]
407
[16"]
529
529
[20 7/8"]
[20 7/8"]
50
1339
[52 3/4"]
310mmØ OPENING 310mmØ OPENING 400
[2"] FOR VENT FOR VENT
2 REQUIRED 2 REQUIRED [15 3/4"]
372mmØ HOLE IN 372mmØ HOLE IN
1876
2591
FOR TOILET FOR TOILET
[102"]
2 REQUIRED 2 REQUIRED
1250
STRUCTURE
[49 1/4"]
[4"]
102
102
[4"]
[6"]
152
SECTION B
102
SCALE:1/50
[4"] 372
[14 5/8"]
TOP VIEW
372mmØ HOLE IN NOTCH TOILET
SCALE:1/50 CONC. SLAB TOP RISER TO
FOR TOILET ACCOMMODATE
2 REQUIRED 2-STAINLESS
124 124 124 STEEL BARS
4876 PROVIDED BY
124
[4 7/8"] [4 7/8"] [4 7/8"] ONTARIO PARKS
[192"]
124
550 1274 542 1274 550 686
50
[21 5/8"] [50 1/8"] [21 3/8"] [50 1/8"] [21 5/8"] [27"] 50
12" x 16" TUFF-TITE
124
RISER WITH COVER [2"] 2-19mmØ ST. STEEL 2-19mmØ ST. STEEL
[4 7/8"] [4 7/8"] [4 7/8"]
[6"]
STRUCTURE
152
ON CENTER ON CENTER
IN OPENING IN OPENING
451
[17 3/4"]
GENERAL NOTES:
2180
[85 7/8"]
1. UNITS ARE SEALED WITH BUTYL TAPE AT THE JOINTS
2. EXCAVATION MUST BE READY, SAFE AND ACCESSIBLE FOR UNLOADING FROM THE REAR
OF THE TRUCK.
4. ALL UNITS MUST BE HANDLED WITH PROPER LIFTING EQUIPMENT (I.E. SPREADER BAR)
407
[16"]
529
529
[20 7/8"]
[20 7/8"]
50
1339
[52 3/4"]
310mmØ OPENING 310mmØ OPENING 400
[2"] FOR VENT FOR VENT
2 REQUIRED 2 REQUIRED [15 3/4"]
372mmØ HOLE IN 372mmØ HOLE IN
CONC. SLAB TOP CONC. SLAB TOP
[89"]
2261
2591
FOR TOILET FOR TOILET
[102"]
2 REQUIRED 2 REQUIRED
1250
STRUCTURE
[49 1/4"]
[4"]
102
102
[6"]
152
[4"] SECTION B
102
SCALE:1/60
[4"] 372
[14 5/8"]
TOP VIEW
372mmØ HOLE IN NOTCH TOILET
CONC. SLAB TOP RISER TO
51
SCALE:1/50
FOR TOILET ACCOMMODATE
2 REQUIRED 2-STAINLESS
124 124 124 STEEL BARS
PROVIDED BY
124
[21 5/8"] [50 1/8"] [21 3/8"] [50 1/8"] [21 5/8"] [27"] 12" x 16" TUFF-TITE [2"] 2-19mmØ ST. STEEL 2-19mmØ ST. STEEL
[4 7/8"] [4 7/8"] [4 7/8"]
[6"]
152
STRUCTURE 451
[17 3/4"]
2565
[101"]
2. EXCAVATION MUST BE READY, SAFE AND ACCESSIBLE FOR UNLOADING FROM THE REAR
OF THE TRUCK.
4. ALL UNITS MUST BE HANDLED WITH PROPER LIFTING EQUIPMENT (I.E. SPREADER BAR)
[60"]
1524
REQUIRED
4" INLET PIPE 3" PVC 3" DIAMETER 24" x 6" TUF-TITE 3" DIAMETER
52
CAST-A-SEAL 402 VENT VENT 4 RISER WITH COVER PVC PIPING
REQUIRED 3 REQUIRED FOR VENT
[4"]
102
PIPE 4" PVC
4" OUTLET
CAST-A-SEAL 402 PIPE 4" PVC
[66"]
[66"]
1676
1676
[54"]
1371
[52"]
1321
200
DIAM. [4"]
[7 7/8"]
3 REQUIRED (TYP)
356
[14"]
76
432
[3"]
[17"]
76 76
[3"](TYP.) [3"](TYP.)
178
SECTION A SECTION B
[7"](TYP.)
SCALE:1/30 SCALE:1/30
1834
REQUIRED
[72 1/4"]
5. ALL UNITS MUST BE HANDLED WITH
PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)
4" INLET 3" DIAMETER 24" x 6" TUF-TITE 24" x 6" TUF-TITE
CAST-A-SEAL 402 VENT RISER WITH COVER RISER WITH COVER
4 REQUIRED 3 REQUIRED 3 REQUIRED
[4"]
102
SANITARY TY
53
4" OUTLET
CAST-A-SEAL 402
1664
1664
[65 1/2"]
[65 1/2"]
1359
1309
[53 1/2"]
[51 1/2"]
DIAM. [4"]
3 REQUIRED (TYP)
200
[7 7/8"]
[5"]
76
127
457
[18"]
533
[21"]
[3"](TYP.)
OPENING 30" x 5"
[8"]
203
76 76
SECTION A [3"](TYP.) SECTION B [3"](TYP.)
SCALE:1/30 SCALE:1/30
CONCRETE: 35MPa / 5,000PSI UNIT WEIGHT: DRAWN BY:
AIR ENTRAINMENT: 6-8% 11,390 lbs / 5,170 KG S.RIMLAND
OIL
MANUFACTURED: REINFORCEMENT : STEEL TO CSA CAN CPA CERTIFIED
MODEL 100 INTERCEPTOR
BROOKLIN, ON A23.1 / A23.3. G30.18 Fy=400MPa MEETS CSA-BB6-00 DATE: 960 IMPERIAL GALLON / 4,400 LITRES
1-800-655-3430 JAN/2018
OPTIMUM FLOW RATE: 53 L/MINUTE
3213
[126 1/2"]
3" PVC PIPING GENERAL NOTES:
FOR VENT
1. UNITS ARE SEALED WITH BUTYL TAPE AT
THE JOINTS
2553
PROPER LIFTING EQUIPMENT (I.E.
[100 1/2"]
SPREADER BAR)
54
4" INLET OPTIONAL INLET 24" x 6" TUF-TITE 3" PVC PIPING 24" x 6" TUF-TITE 3" PVC PIPING 10M LIFTING
CAST-A-SEAL 402 4" PVC POLYSEAL RISER WITH COVER FOR VENT RISER WITH COVER FOR VENT ANCHOR
3 REQUIRED 4 REQUIRED 3 REQUIRED 4 REQUIRED 4 REQUIRED (TYP)
140
[5 1/2"]
4" OUTLET
CAST-A-SEAL 402 PIPE 4" PVC
[63"]
[63"]
1601
1601
[53"]
1346
[51"]
1296
DIAM. [4"]
76
76
3 REQUIRED (TYP)
[5"]
127
[4"]
102
[3"](TYP.)
[3"] (TYP.)
457
[18"]
OPENING 30" x 5"
76 76
[3"](TYP.) [3"](TYP.)
SECTION A SECTION B
SCALE:1/40 SCALE:1/40
2591
[102"]
AWAY FROM ANY VEHICULAR TRAFFIC
55
100Ø T-PIPE
ASSEMBLY
3" DIAMETER VENT- 3 TUFF TITE 24" COVER
4" INLET REQUIRED.3 4" CLEARSTONE WITH 12"X24" RISER 4" INLET
CAST-A-SEAL 402 @300MM RADIUS AROUND 3 REQUIRED (TYP.) CAST-A-SEAL 402
[5"]
127
PIPE
POLYSEAL WITH 3" DIAMETER VENT.
FLANGE 3 REQUIRED
350
[13 3/4"]
4" OUTLET
DIAM 4" OPENING. CAST-A-SEAL 402
3 REQUIRED (TYP.) 127
[5"]
[59"]
[59"]
1499
1499
1149
[44"]
1118
[45 1/4"]
380
OPENING AT 3 REQUIRED (TYP.)
[15"]
87
600
108
108
[4 1/4"]
457
BASE LEVEL
[18"]
[4 1/4"]
[23 5/8"]
[3 3/8"]
STOP VALVE W/ OPENING 30" x 5"
P-TRAP ASSEMBLY. AT BASE LEVEL
170
[6 3/4"]
5055 2591
[199"] [102"]
SECTION A SECTION B
SCALE:1/50 SCALE:1/50
56
610 914 305 610
[24"] [36"] [12"] [24"]
51
51
[2"]
[2"]
432
432
[17"]
[17"]
381
381
[15"]
[15"]
SECTION A SECTION B SECTION A SECTION B
SCALE:1/16 SCALE:1/16 SCALE:1/16 SCALE:1/16
76
[3"]
559
[22"]
[6"]
154
CROSS SECTION
SCALE:1/16
16"DIA. X 6"
TOP VIEW TUF-TITE RISER
2 - 5 116" GALV. LIFTING
HOOK WITH COVER
SCALE:1/16
610
[24"] RETROFIT 20"X24"
610
[24"]
406
[16"]
508
[20"]
76
[3"]
[6"]
154
CROSS SECTION
SCALE:1/16
57
2 - 5 116" GALV. LIFTING TOP VIEW 16"DIA. X 6"
HOOK SCALE:1/16 TUF-TITE RISER
WITH COVER
813
[32"]
2 - 5 116" GALV. LIFTING
HOOK
RETROFIT 32"X32"
76
[3"]
813
[32"]
406
813
[32"]
[16"] I.D.
76
[3"]
[6"]
152
16"DIA. X 6"
TUF-TITE RISER
WITH COVER
Drip Proof
Access Doors
Flush Mount
Access Doors
Access Ladders
58
BROOKLIN OFFICE NEWMARKET OFFICE HUNTSVILLE /HALIBURTON OFFICE
brooklinsales@brooklin.com newmarketsales@brooklin.com huntsvillesales@brooklin.com
60
Warranty Policy
This warranty does not apply to any product that has been
subjected to abuse or misuse, or to a product that has been
altered or modified by others in any way so as, in our judgment,
to affect its dependability. Brooklin Concrete Product’s liability
shall be limited to the repair or replacement of its product, the
cost of which shall not exceed the original purchase price of the
product.
61
COMPANY PRODUCT
POLICIES
62
Special Order Policy
63
Return/Exchange Policy
64
Septic Tank Delivery Policy
65
GUIDELINES & TESTING
OF TANK INSTALLATION
66
Installation Guidelines
Site
Excavation
67
Soil Conditions
Back Filling
68
Joint Seal
1. The mating surfaces of the joint must be clean and dry. The
lower precast section should be placed in its final position in
the excavation. The joint of this section should be made clean
and dry, then mastic strips of sealant applied. Ensure that the
ends of each strip overlap by a minimum of 26mm as the
sealant is laid around the joint.
3. Once the joint surfaces are clean, dry, free of debris and
extra mastic has been applied in areas where the male or
female joint might have been chipped or broken in handling,
the upper section can be carefully set directly onto the lower
section.
69
4. Allow the structure to stand until the mastic is completely
crushed in to all parts of the joint and it stops extruding from
the sides. Remove the excess mastic and ensure the outer wall
is clean and dry in the area 8” above and below the joint. Apply
TWO COATS of mastic primer using a paint roller to the outer
wall surface. (8” above and below the joint)
70
Testing
Pipe Connections
Joint
Fill the tank with water to 18 inches (460mm) above the joint.
Observe the outside of the tank at the joint for a suitable
period of time; usually 2 – 24 hours.
Assembled Tank
71
Caution: Filling the tank with liquid before
backfilling
Many of the precast tanks detailed in this catalogue rely on
support from the surrounding earth, in which they are buried,
to resist stress imposed by the contained liquid. It is
recommended that the tank at no time be filled higher than 24
inches (600mm) above the lowest outside level of backfill.
72
BROOKLIN OFFICE NEWMARKET OFFICE HUNTSVILLE /HALIBURTON OFFICE
brooklinsales@brooklin.com newmarketsales@brooklin.com huntsvillesales@brooklin.com
WWW.BROOKLIN.COM