You are on page 1of 76

SEPTIC TANK

SYSTEMS Product Guide

Septic Tanks

Pump Tanks

Single Chamber Tanks

​Fire Protection/
Water Storage Systems

Privy Tanks

Oil Interceptors

Tank Accessories
Brooklin Concrete is a precast concrete manufacturer of various designs
and sizes in pump tanks, single chamber tanks, septic tanks, and specialty
systems. We maintain strict quality control during production and offer a
comprehensive line of products. Our complete fleet of crane equipped trucks
can deliver and place your new tank. More importantly, our commitment to
customers extends beyond the sale. Quality, versatility and service, along
with competitive pricing constitute our main strengths.

Our in house design staff can prepare shop drawings for engineer review,
including custom designs if required. No project is too big or small for our
team to offer support.

Thank you for your interest in Brooklin Concrete, we hope you will find this
catalogue a valuable guide in your septic system needs. Included for your
use in this guide are product descriptions, design pages for each item, and
accessory descriptions.

For additional information please call us toll free at 1-800-655-3430

You can also visit our website at www.brooklin.com


INDEX
36,300L............................................ 35
Septic Tanks 45,500L............................................ 36
Warranty & Return
3,600L.................................................. 1 72,700L............................................ 37 Exchange Policies
3,600L Low High............................... 2 90,900L............................................ 38
Warranty Policy............................. 61
4,500L.................................................. 3
4,500L Low High............................... 4 Fire Protection/
6,135L.................................................. 5
Water Storage Company Product
7,000L.................................................. 6
Systems Policies
7,500L Low Height........................... 7
9000L................................................... 8 Special Order Policy..................... 63
22,750L Single............................... 39
13,650L............................................... 9 Return/Exchange Policy............. 64
22,750L Nested.............................. 40
13,650L (Ottawa)........................... 10 Septic Tank Delivery Policy........ 65
30,000L Single............................... 41
18,000L............................................ 11
30,000L Nested.............................. 42
22,750L............................................ 12
45,000L Single............................... 43 Guidelines & Testing
30,000............................................... 13
36,300L.............................................14
45,000L Nested.............................. 44
90,000L Single............................... 45
of Tank Installation
45,500L............................................ 15
90,000L Nested.............................. 46 Installation Guidelines................. 67
68,200L............................................ 16
Soil Conditions/Back Filling....... 68
86,000L............................................ 17
Privy Tanks Joint Seal......................................... 69
Joint Seal Cont............................... 70
Pump Tanks Privy 1000 Low Wood.................. 47
Testing.............................................. 71
Privy 2500 Wood........................... 48
Caution............................................. 72
346L................................................... 18 Privy 3000 Wood........................... 49
680L & 1,365L................................ 19 Privy 4000 Wood........................... 50
2,700L............................................... 20 Privy 5000 Wood........................... 51
3,600L Low Height........................ 21
3.600L .............................................. 22
Oil Interceptors
4,500L Low Height........................ 23
4,500L .............................................. 24 Model 65.......................................... 52
6,135L............................................... 25 Model 100........................................ 53
7000L................................................ 26 Model 155........................................ 54
7,500L Low Height........................ 27 Model 250........................................ 55

Single Chamber Tank Accessories


Tanks
Distribution Boxes......................... 56
9,000L Low Height........................ 28
Retrofit Lids..................................... 57
9,000L............................................... 29
Aluminum Accessories............... 58
11,365L............................................ 30
13,650L............................................ 31
18,000L............................................ 32
22,750L............................................ 33
30,000L............................................ 34
2540
[100"]

GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL TAPE AT


THE JOINTS

2. DELIVERY IS MADE BY CRANE-EQUIPPED


TRUCKS

3. EXCAVATION MUST BE READY, SAFE AND


ACCESSIBLE FOR UNLOADING FROM THE
REAR OF THE TRUCK.

[54"]
1372
4. MIN OVERHEAD CLEARANCE OF 18FT IS
REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE IN


FIRM SOIL AWAY FROM ANY VEHICULAR
TRAFFIC

24" x 6" TUF-TITE


RISER WITH COVER TOP VIEW
2 REQUIRED SCALE:1/30
24" x 6" TUF-TITE RISER 24" x 6" TUF-TITE RISER
WITH COVER. 2 REQUIRED WITH COVER. 2 REQUIRED
2438 1270
[96"] [50"]

1
4" INLET
CAST-A-SEAL 402
TUF-TITE EFFLUENT
FILTER EF-6
OPTIONAL INLET OPENING 12" x 4"
4" PVC POLYSEAL 4" OUTLET (TYP.)
CAST-A-SEAL 402 BAFFLE
BAFFLE
127

152
[5"] (TYP.)

1344 [6"](TYP.)
LIQUID DEPTH
[70"]
1778

[67"]
1702
255

[58"]
1470
[56"]
1422 (TYP.)

775
851

[30 1/2"]
[33 1/2"]

76
[3"]

76 76 76

[3"]
76
[3"] [3"] [3"]
2540 1372
[100"] [54"]
SECTION A SECTION B
SCALE:1/30 SCALE:1/30

CONCRETE: 35MPa at 28 days / 5000PSI UNIT WEIGHT: 6,490lbs / 2,943kg DRAWN BY:
AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 3600 LITRES SEPTIC TANK
800 IMPERIAL GALLON
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-B66
BROOKLIN, ON DATE: WORKING CAPACITY: 3,723 LITRES TO INVERT OF OUTLET
A23.1 /A23.3 G30.18 Fy=400MPa
1-800-655-3430 JAN / 2018
TOTAL CAPACITY: 4,259 LITRES TO UNDERSIDE OF CHAMBER LID
2543
[100"]
GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL TAPE AT


THE JOINTS

2. DELIVERY IS MADE BY CRANE-EQUIPPED


TRUCKS

3. EXCAVATION MUST BE READY, SAFE AND


ACCESSIBLE FOR UNLOADING FROM THE
REAR OF THE TRUCK.

[66"]
1679
4. MIN OVERHEAD CLEARANCE OF 18FT IS
REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE IN


FIRM SOIL AWAY FROM ANY VEHICULAR
TRAFFIC

24" x 6" TUF-TITE


RISER WITH COVER TOP VIEW
2 REQUIRED SCALE:1/30

24" x 6" TUF-TITE RISER 24" x 6" TUF-TITE RISER


WITH COVER. 2 REQUIRED WITH COVER. 2 REQUIRED
2467 1603
[97"] [63"]
4" INLET
CAST-A-SEAL 402

2
TUF-TITE EFFLUENT
FILTER EF-6
OPENING 12" x 4" (TYP.)
OPTIONAL INLET
4" PVC POLYSEAL 4" OUTLET
BAFFLE CAST-A-SEAL 402
BAFFLE
102
[4"](TYP.)

1041
LIQUID DEPTH
[59"]
1498

[56"]
1422
357 152

[46"]
1167
[44"]
1117
(TYP.) [6"](TYP.)

635
[25"]
711
[28"]

76
[3"]

76 76 76

[3"]
76
[3"] [3"] [3"]
2543 1679
[100"] [66"]
SECTION A SECTION B
SCALE:1/30 SCALE:1/30
CONCRETE: 35MPa at 28 days/5000PSI UNIT WEIGHT: 6,940lbs / 3,147kg DRAWN BY:
AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND
LOW HEIGHT
800 IMPERIAL GALLON
3600 LITRES SEPTIC TANK
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-B66
DATE: WORKING CAPACITY: 3,668 LITRES TO INVERT OF OUTLET
BROOKLIN, ON A23.1 /A23.3 G30.18 Fy=400MPa
1-800-655-3430 JAN/2018 TOTAL CAPACITY: 4,450 LITRES TO UNDERSIDE OF CHAMBER LID
2540
[100"]
GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL TAPE AT


THE JOINTS

2. DELIVERY IS MADE BY CRANE-EQUIPPED


TRUCKS

3. EXCAVATION MUST BE READY, SAFE AND


ACCESSIBLE FOR UNLOADING FROM THE
REAR OF THE TRUCK.

4. MIN OVERHEAD CLEARANCE OF 18FT IS

[66"]
1676
REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE IN


FIRM SOIL AWAY FROM ANY VEHICULAR
TRAFFIC

24" x 6" TUF-TITE


RISER WITH COVER TOP VIEW
2 REQUIRED
SCALE:1/30

24" x 6" TUF-TITE RISER WITH 24" x 6" TUF-TITE RISER WITH

3
2450 COVER. 2 REQUIRED COVER. 2 REQUIRED 1586
[96 1/2"] [62 1/2"]

76
4" INLET
CAST-A-SEAL 402

[3"](TYP.)
TUF-TITE
EFFLUENT
FILTER EF-6
OPTIONAL INLET OPENING 12" x 4"
4" PVC POLYSEAL 4" OUTLET (TYP.)
CAST-A-SEAL 402
BAFFLE BAFFLE
127
[5"] (TYP.)

1344
LIQUID DEPTH
[69"]
1752

[66"]
[66"]

1676
1676

152 508

[58"]
1472
[56"]
1420

(TYP.) [20"](TYP.)
838
[33"]

76
76

[3"]
[3"]

76 76
[3"] (TYP.) [3"](TYP.)
SECTION A SECTION B
SCALE:1/30 SCALE:1/30

CONCRETE: 35MPa at 28 days / 5000PSI UNIT WEIGHT: 8,200lbs DRAWN BY:


AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 4500 LITRES SEPTIC TANK
1000 IMPERIAL GALLON
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-BB6-00
DATE: WORKING CAPACITY: 4,687 LITRES TO INVERT OF OUTLET
BROOKLIN, ON A23.1 / A23.3. G30.18 Fy=400MPa
1-800-655-3430 JAN/2018 TOTAL CAPACITY: 5,287 LITRES TO UNDERSIDE OF CHAMBER LID
2972
[117"]

GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL TAPE AT


THE JOINTS

2. DELIVERY IS MADE BY CRANE-EQUIPPED


TRUCKS

3. EXCAVATION MUST BE READY, SAFE AND


ACCESSIBLE FOR UNLOADING FROM THE
REAR OF THE TRUCK.

4. MIN OVERHEAD CLEARANCE OF 18FT IS


REQUIRED

[86"]
2184
5. ALL UNITS MUST BE HANDLED WITH
PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE IN


FIRM SOIL AWAY FROM ANY VEHICULAR
TRAFFIC

24" x 6" TUF-TITE


RISER WITH COVER TOP VIEW
2 REQUIRED
SCALE:1/30

24" x 6" TUF-TITE RISER 24" x 6" TUF-TITE RISER


WITH COVER. 2 REQUIRED WITH COVER. 2 REQUIRED
2870 2082

4
[113"] [82"]
4" INLET
CAST-A-SEAL 402
TUF-TITE
EFFLUENT
FILTER EF-6 OPENING 12" x 4"
OPTIONAL INLET
4" PVC POLYSEAL 4" OUTLET (TYP.)
127

CAST-A-SEAL 402
BAFFLE BAFFLE
[5"] (TYP.)

940
LIQUID DEPTH
[54"]
1371

[51"]
1295
153 508

[42"]
1067
[40"]
1016

(TYP.) [20"](TYP.)
648
[25 1/2"]

76
76

[3"]
[3"]

76 76
[3"] (TYP.) SECTION A [3"] SECTION B
SCALE:1/30 SCALE:1/30

CONCRETE: 35MPa at 28 days / 5000PSI UNIT WEIGHT: 11,620 lbs DRAWN BY:
CPA CERTIFIED S.RIMLAND
LOW HEIGHT
AIR ENTRAINMENT: 6-8%
1000 IMPERIAL GALLON
4500 LITRES SEPTIC TANK
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-BB6-00
DATE: WORKING CAPACITY: 5,214 LITRES TO INVERT OF OUTLET
BROOKLIN, ON A23.1 /A23.3 G30.18 Fy=400MPa
1-800-655-3430 JAN/2018 TOTAL CAPACITY: 6,305 LITRES TO UNDERSIDE OF CHAMBER LID
3001
[118 1/8"]
10M LIFTING ANCHOR
4 REQUIRED (TYP.)
GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL TAPE AT


THE JOINTS

2. DELIVERY IS MADE BY CRANE-EQUIPPED


TRUCKS

3. EXCAVATION MUST BE READY, SAFE AND


ACCESSIBLE FOR UNLOADING FROM THE
REAR OF THE TRUCK.

4. MIN OVERHEAD CLEARANCE OF 18FT IS


REQUIRED

5. ALL UNITS MUST BE HANDLED WITH

2290
PROPER LIFTING EQUIPMENT (I.E.

[90 1/8"]
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE IN


FIRM SOIL AWAY FROM ANY VEHICULAR
TRAFFIC

5
24" x 6" TUF-TITE
RISER WITH COVER TOP VIEW
2 REQUIRED
SCALE:1/30
24" x 6" TUF-TITE 10M LIFTING ANCHOR
4" INLET OPTIONAL INLET 24" x 6" TUF-TITE RISER WITH COVER 4 REQUIRED (TYP.)
CAST-A-SEAL 402 4" PVC POLYSEAL RISER WITH COVER 2 REQUIRED
2 REQUIRED
TUF-TITE
EFFLUENT
FILTER EF-6
4" OUTLET
140

CAST-A-SEAL 402
[5 1/2"]

BAFFLE BAFFLE

[63"]
1613

1601
1193
[63 1/2"]

LIQUID DEPTH DIAM. 127 / [5"]

[53"]
1346
[50"]

(TYP.)
1269
724
[28 1/2"]

74 25
SECTION A [2 7/8"] [1"]
SECTION B
SCALE:1/30 SCALE:1/30
CONCRETE: 35MPa at 28 days/5000PSI UNIT WEIGHT: 13,400 lbs DRAWN BY:
AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 6135 LITRES SEPTIC TANK
1350 IMPERIAL GALLON
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-BB6-00
DATE: WORKING CAPACITY: 6,169 LITRES TO INVERT OF OUTLET
BROOKLIN, ON A23.1 /A23.3 G30.18 Fy=400MPa
1-800-655-3430 JAN/2018 TOTAL CAPACITY: 7,192 LITRES TO UNDERSIDE OF CHAMBER LID
3213
GENERAL NOTES:
[126"]
1. UNITS ARE SEALED WITH BUTYL TAPE AT
THE JOINTS

2. DELIVERY IS MADE BY CRANE-EQUIPPED


TRUCKS

3. EXCAVATION MUST BE READY, SAFE AND


ACCESSIBLE FOR UNLOADING FROM THE
REAR OF THE TRUCK.

4. MIN OVERHEAD CLEARANCE OF 18FT IS


REQUIRED

5. ALL UNITS MUST BE HANDLED WITH

2553
PROPER LIFTING EQUIPMENT (I.E.

[101"]
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE IN


FIRM SOIL AWAY FROM ANY VEHICULAR
TRAFFIC

10M LIFTING
ANCHOR.
4 REQUIRED (TYP)

24" x 6" TUF-TITE


RISER WITH COVER
2 REQUIRED
TOP VIEW
SCALE:1/40

2911

6
[114 5/8"]
4" INLET OPTIONAL INLET 24" x 6" TUF-TITE 24" x 6" TUF-TITE 10M LIFTING
CAST-A-SEAL 402 4" PVC POLYSEAL RISER WITH COVER RISER WITH COVER ANCHOR
108

2 REQUIRED 2 REQUIRED 4 REQUIRED (TYP)


[4 1/4"]

TUF-TITE EFFLUENT
FILTER EF-6

4" OUTLET
CAST-A-SEAL 402 BAFFLE
BAFFLE

DIAM. 127 [5"]


1194 3 REQUIRED (TYP)

1581
1581

LIQUID DEPTH 550

[62 1/4"]
[62 1/4"]

[52"]
1321
[50"]
1270
[21 5/8"](TYP.)

76
76

2214
775

[3"](TYP.)
[3"](TYP.)

[87 1/8"]
[30 1/2"]

76 76
[3"](TYP.) [3"](TYP.)

SECTION A SECTION B
SCALE:1/40 SCALE:1/40

CONCRETE: 35MPa at 28 days/5000PSI UNIT WEIGHT: 14,460 lbs DRAWN BY:


AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 7000 LITRES SEPTIC TANK
1550 IMPERIAL GALLON
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-BB6-00
DATE: WORKING CAPACITY: 7,564 LITRES TO INVERT OF OUTLET
BROOKLIN, ON A23.1 /A23.3 G30.18 Fy=400MPa
1-800-655-3430 JAN/2018 TOTAL CAPACITY: 8,892 LITRES TO UNDERSIDE OF CHAMBER LID
4039
[159"]

GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL


TAPE AT THE JOINTS

2. DELIVERY IS MADE BY
CRANE-EQUIPPED TRUCKS
TUF-TITE
EFFLUENT 3. EXCAVATION MUST BE READY, SAFE
FILTER EF-6 AND ACCESSIBLE FOR UNLOADING
FROM THE REAR OF THE TRUCK.

[90"]
2286
4. MIN OVERHEAD CLEARANCE OF
18FT IS REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)
10M LIFTING
ANCHOR. 6. MAXIMUM BURIAL DEPTH = 1 METRE
4 REQUIRED (TYP) IN FIRM SOIL AWAY FROM ANY
VEHICULAR TRAFFIC

24" x 6" TUF-TITE


RISER WITH COVER TOP VIEW
2 REQUIRED SCALE:1/40

7
10M LIFTING
4" INLET OPTIONAL INLET 24" x 6" TUF-TITE 24" x 6" TUF-TITE ANCHOR
CAST-A-SEAL 402 4" PVC POLYSEAL RISER WITH COVER RISER WITH COVER 4 REQUIRED (TYP)
2 REQUIRED

[5"]
2 REQUIRED

127
TUF-TITE
EFFLUENT
FILTER EF-6

4" OUTLET
CAST-A-SEAL 402 BAFFLE
BAFFLE

OPENING
[58"]

[58"]
1473

1473
1092
670 DIAM 4" (TYP.)
LIQUID DEPTH

1232
1181

3 REQUIRED

[48 1/2"]
76
[46 1/2"]

[26 3/8"]
76
711
[28"]

[3"](TYP.)
[3"](TYP.)

76 76
[3"](TYP.) [3"](TYP.)

SECTION A SECTION B
SCALE:1/40 SCALE:1/40

CONCRETE: 35MPa/5000PSI WEIGHT: DRAWN BY: LOW HEIGHT


AIR ENTRAINMENT: 6-8% 17,250lbs / 7,825kg S.RIMLAND
1650 IMPERIAL GALLON
7500 LITRES SEPTIC TANK
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN CPA CERTIFIED
DATE: WORKING CAPACITY: 8,219 LITRES TO INVERT OF OUTLET
BROOKLIN, ON A23.1 /A23.3 G30.18 Fy=400MPa MEETS CSA-BB6-00
1-800-655-3430 JAN/2018 TOTAL CAPACITY: 9,624 LITRES TO UNDERSIDE OF CHAMBER LID
4039
[159"]
24" x 6" TUF-TITE
RISER WITH COVER
2 REQUIRED
GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL


TAPE AT THE JOINTS

2. DELIVERY IS MADE BY
CRANE-EQUIPPED TRUCKS
TUF-TITE
EFFLUENT 3. EXCAVATION MUST BE READY, SAFE
FILTER EF-6 AND ACCESSIBLE FOR UNLOADING
FROM THE REAR OF THE TRUCK.

[90"]
2286
4. MIN OVERHEAD CLEARANCE OF
18FT IS REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)
10M LIFTING
ANCHOR. 6. MAXIMUM BURIAL DEPTH = 1 METRE
4 REQUIRED (TYP) IN FIRM SOIL AWAY FROM ANY
VEHICULAR TRAFFIC

TOP VIEW
SCALE:1/40

24" x 6" TUF-TITE 10M LIFTING


4" INLET OPTIONAL INLET 24" x 6" TUF-TITE RISER WITH COVER ANCHOR
2 REQUIRED 4 REQUIRED (TYP)

8
CAST-A-SEAL 402 4" PVC POLYSEAL RISER WITH COVER

[5"]
2 REQUIRED

127
TUF-TITE
EFFLUENT
FILTER EF-6

4" OUTLET
CAST-A-SEAL 402 BAFFLE
BAFFLE

1295
OPENING
[66"]

[66"]
1677

1677
LIQUID DEPTH
670 DIAM 4" (TYP.)

[56"]
1423
[54"]
1372

3 REQUIRED
[26 3/8"]

76
76
686
[27"]

[3"](TYP.)
[3"](TYP.)

76 76
[3"](TYP.) [3"](TYP.)
SECTION A SECTION B
SCALE:1/40 SCALE:1/40

CONCRETE: 35MPa at 28 days/5000PSI WEIGHT: DRAWN BY:


AIR ENTRAINMENT: 6-8% 17,895lbs / 8,120kg S.RIMLAND 9000 LITRES SEPTIC TANK
2000 IMPERIAL GALLON
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN CPA CERTIFIED
DATE: WORKING CAPACITY: 9,755 LITRES TO INVERT OF OUTLET
BROOKLIN, ON A23.1 /A23.3 G30.18 Fy=400MPa MEETS CSA-BB6-00
1-800-655-3430 JAN/2018 TOTAL CAPACITY: 11,169 LITRES TO UNDERSIDE OF CHAMBER LID
5055
[199"]

GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL TAPE


AT THE JOINTS

TUF-TITE 2. DELIVERY IS MADE BY


EFFLUENT CRANE-EQUIPPED TRUCKS
FILTER EF-6
2 REQUIRED 3. EXCAVATION MUST BE READY, SAFE
AND ACCESSIBLE FOR UNLOADING
FROM THE REAR OF THE TRUCK.

2591
[102"]
4. MIN OVERHEAD CLEARANCE OF 18FT
IS REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE


IN FIRM SOIL AWAY FROM ANY
VEHICULAR TRAFFIC
TUFF TITE 24" COVER
WITH 6"X24" RISER
2 REQUIRED (TYP.) TOP VIEW
SCALE:1/50

9
TUFF TITE 24" COVER TUFF TITE 24" COVER
4" INLET WITH 6"X24" RISER WITH 6"X24" RISER
CAST-A-SEAL 402 2 REQUIRED (TYP.) 2 REQUIRED (TYP.)

[5"]
[5"]

127
127

280
[11"]
OPENING
BAFFLE 4" OUTLET 305 23 4"X12"(TYP.)
CAST-A-SEAL 402 3 REQUIRED
[12"]
70

TUF-TITE
[2 3/4"]

EFFLUENT
FILTER EF-6 127
OPENING

[69"]
[69"]

1753
1753

1238
2 REQUIRED [5"] DIAM. 4"(TYP.)
LIQUID DEPTH

[56"]
1423
[53"]
1346

3 REQUIRED
87

108
108

[4 1/4"]
[4 1/4"]

[3 3/8"]

5055 2591
[199"] [102"]

SECTION A SECTION B
SCALE:1/50 SCALE:1/50

CONCRETE: 35MPa at 28 days/5000PSI WEIGHT: 29,300lbs / 13,290kg DRAWN BY: SEPTIC


S.RIMLAND
AIR ENTRAINMENT: 6-8% CPA CERTIFIED
13650 LITRES
3,000 IMPERIAL GALLON TANK
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN
BROOKLIN, ON A23.1 /A23.3 G30.18 Fy=400MPa DATE: WORKING CAPACITY: 13,797 LITRES TO INVERT OF OUTLET
1-800-655-3430 JAN/2018
TOTAL CAPACITY: 16,920 LITRES TO UNDERSIDE OF CHAMBER LID
5055
[199"]

GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL


TAPE AT THE JOINTS
TUF-TITE
EFFLUENT 2. DELIVERY IS MADE BY
FILTER EF-6 CRANE-EQUIPPED TRUCKS
2 REQUIRED
3. EXCAVATION MUST BE READY, SAFE
AND ACCESSIBLE FOR UNLOADING
FROM THE REAR OF THE TRUCK.

2591
[102"]
4. MIN OVERHEAD CLEARANCE OF
18FT IS REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE


IN FIRM SOIL AWAY FROM ANY
VEHICULAR TRAFFIC
TUFF TITE 24" COVER
WITH 6"X24" RISER
2 REQUIRED (TYP.)
TOP VIEW
SCALE:1/50

TUFF TITE 24" COVER


4" INLET OPTIONAL INLET TUFF TITE 24" COVER WITH 6"X24" RISER
CAST-A-SEAL 402 4" PVC POLYSEAL WITH 6"X24" RISER 2 REQUIRED (TYP.)

10
108
2 REQUIRED (TYP.)

[4 1/4"]
4" OUTLET OPENING
CAST-A-SEAL 402 127 DIAM. 4" (TYP.)
864
[34"]

3 REQUIRED
[5"]
127

BAFFLE [5"]
TUF-TITE
EFFLUENT 127

[68"]
1727
1275 274
FILTER EF-6

1435
[5"]

1383
LIQUID DEPTH 2 REQUIRED [10 3/4"]

[56 1/2"]
[54 1/2"]
86
864
[34"]

108
108

[3 3/8"]

[4 1/4"]
[4 1/4"]

5055 2591
[199"] [102"]

SECTION A SECTION B
SCALE:1/50 SCALE:1/50

CONCRETE: 35MPa at 28 days / 5000PSI WEIGHT: 26,142lbs / 11,857kg DRAWN BY:


AIR ENTRAINMENT: 5-8% BOTTOM: 13,071lbs S.RIMLAND 13650 LITRES SEPTIC
3,000 IMPERIAL GALLON TANK
MANUFACTURED: MEETS CAN/CSA-B66-00 TOP: 13,071lbs
BROOKLIN, ON DATE: WORKING CAPACITY: 14,211 LITRES TO INVERT OF OUTLET
REINFORCEMENT: STEEL TO CSA CAN
CPA CERTIFIED
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018
TOTAL CAPACITY: 16,765 LITRES TO UNDERSIDE OF CHAMBER LID
5055
[199"]

GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL


TAPE AT THE JOINTS

PL-525 EFFLUENT 2. DELIVERY IS MADE BY


FILTER CRANE-EQUIPPED TRUCKS

3. EXCAVATION MUST BE READY, SAFE


AND ACCESSIBLE FOR UNLOADING
FROM THE REAR OF THE TRUCK.

2591
[102"]
4. MIN OVERHEAD CLEARANCE OF
18FT IS REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE


IN FIRM SOIL AWAY FROM ANY
VEHICULAR TRAFFIC
TUFF TITE 24" COVER
WITH 6"X24" RISER
2 REQUIRED (TYP.)
TOP VIEW
SCALE:1/50

11
TUFF TITE 24" COVER
4" INLET TUFF TITE 24" COVER WITH 6"X24" RISER
OPTIONAL INLET
CAST-A-SEAL 402 WITH 6"X24" RISER 2 REQUIRED (TYP.)
4" PVC POLYSEAL

108
[4 1/4"]
2 REQUIRED (TYP.)

4" OUTLET OPENING


CAST-A-SEAL 402 DIAM. 4" (TYP.)
3 REQUIRED
PL-525 EFFLUENT 127
BAFFLE
FILTER
[5"]
127

1344 [5"]
LIQUID DEPTH
4"PVC CAP TAP CON

2096
2096

TO WALL w/4" PVC


127

[82 1/2"]
[82 1/2"]

274
TEE GLUE TO CAP

1810
1758

[71 1/4"]
[69 1/4"]

[10 3/4"] [5"]

86

108
108

[3 3/8"]
[4 1/4"]
[4 1/4"]

5055 2591
[199"] [102"]

SECTION A SECTION B
SCALE:1/50 SCALE:1/50

CONCRETE: 35MPa at 28 days / 5000PSI WEIGHT: 31,140lbs / 14,125kg DRAWN BY:


AIR ENTRAINMENT: 6-8% BOTTOM: 15,780lbs S.RIMLAND 18000 LITRES SEPTIC
4000 IMPERIAL GALLON TANK
MANUFACTURED: MEETS CAN/CSA-B66-00 TOP: 15,360lbs
DATE: WORKING CAPACITY: 18,470 LITRES TO INVERT OF OUTLET
BROOKLIN, ON REINFORCEMENT: STEEL TO CSA CAN
CPA CERTIFIED
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018 TOTAL CAPACITY: 21,007 LITRES TO UNDERSIDE OF CHAMBER LID
5055
[199"]

GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL


PL-525 EFFLUENT TAPE AT THE JOINTS
FILTER
2. DELIVERY IS MADE BY
CRANE-EQUIPPED TRUCKS

3. EXCAVATION MUST BE READY,


SAFE AND ACCESSIBLE FOR
UNLOADING FROM THE REAR OF

2591
[102"]
THE TRUCK.

4. MIN OVERHEAD CLEARANCE OF


18FT IS REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE


IN FIRM SOIL AWAY FROM ANY
VEHICULAR TRAFFIC
TUFF TITE 24" COVER
WITH 6"X24" RISER TOP VIEW
2 REQUIRED (TYP.)
SCALE:1/50

TUFF TITE 24" COVER


WITH 6"X24" RISER
4" INLET OPTIONAL INLET TUFF TITE 24" COVER
2 REQUIRED (TYP.)
CAST-A-SEAL 402 4" PVC POLYSEAL WITH 6"X24" RISER

108
[4 1/4"]
2 REQUIRED (TYP.)

12
OPENING
4" OUTLET
DIAM. 4" (TYP.)
CAST-A-SEAL 402
3 REQUIRED
BAFFLE PL-525 EFFLUENT
FILTER
2076 127
[5"]
127

LIQUID DEPTH [5"]


4"PVC CAP TAP CON
TO WALL w/4" PVC

2527
2527

TEE GLUE TO CAP

[99 1/2"]
[99 1/2"]

274

[88"]
2235
[86"]
2184
[10 3/4"] 127
[5"]

86

108
108

[3 3/8"]

[4 1/4"]
[4 1/4"]

5055 2591
[199"] [102"]

SECTION A SECTION B
SCALE:1/50 SCALE:1/50

CONCRETE: 35MPa at 28 days/5000PSI WEIGHT: 34,870lbs / 15,820kg DRAWN BY:


S.RIMLAND
SEPTIC
AIR ENTRAINMENT: 6-8% CPA CERTIFIED
22750 LITRES
5000 IMPERIAL GALLON TANK
MANUFACTURED: MEETS CAN/CSA-B66-00
DATE: WORKING CAPACITY: 23,248 LITRES TO INVERT OF OUTLET
BROOKLIN, ON REINFORCEMENT: STEEL TO CSA CAN
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018 TOTAL CAPACITY: 25,853 LITRES TO UNDERSIDE OF CHAMBER LID
5055
[199"]

GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL TAPE


AT THE JOINTS
PL-525 EFFLUENT
2. DELIVERY IS MADE BY CRANE-EQUIPPED
FILTER
TRUCKS

3. EXCAVATION MUST BE READY, SAFE


AND ACCESSIBLE FOR UNLOADING
FROM THE REAR OF THE TRUCK.

2591
[102"]
4. MIN OVERHEAD CLEARANCE OF 18FT IS
REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE IN


FIRM SOIL AWAY FROM ANY VEHICULAR
TRAFFIC
TUFF TITE 24" COVER
WITH 6"X24" RISER TOP VIEW
2 REQUIRED (TYP.)
SCALE:1/50

TUFF TITE 24" COVER


4" INLET OPTIONAL INLET TUFF TITE 24" COVER WITH 6"X24" RISER
CAST-A-SEAL 402 4" PVC POLYSEAL WITH 6"X24" RISER 2 REQUIRED (TYP.)

108
2 REQUIRED (TYP.)

13
[4 1/4"]
OPENING
4" OUTLET DIAM. 4" (TYP.)
CAST-A-SEAL 402 3 REQUIRED
PL-525 EFFLUENT
FILTER

2768 4"PVC CAP TAP CON 127


TO WALL w/4" PVC
[5"]

LIQUID DEPTH
127

TEE GLUE TO CAP [5"]

3251
3251

[128"]
[128"]

274

2877
2826

[10 3/4"]

[113 1/4"]
[111 1/4"]

127
[5"]

86

108
108

[3 3/8"]

[4 1/4"]
[4 1/4"]

5055 2591
[199"] [102"]

SECTION A SECTION B
SCALE:1/50 SCALE:1/50

CONCRETE: 35MPa at 28 days / 5000PSI WEIGHT: 40,905lbs / 18,555kg DRAWN BY:


AIR ENTRAINMENT: 6-8% S.RIMLAND
SEPTIC
CPA CERTIFIED 30000 LITRES
MEETS CAN/CSA-B66-00 6600 IMPERIAL GALLON TANK
MANUFACTURED:
REINFORCEMENT : STEEL TO CSA CAN DATE: WORKING CAPACITY: 30,404 LITRES TO INVERT OF OUTLET
BROOKLIN, ON
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018 TOTAL CAPACITY: 33,918 LITRES TO UNDERSIDE OF CHAMBER LID
7315
[288"] 3048

152 [120"]
152 152
[6"]
[6"] 2"X45"OPENING [6"]

[6"]
152
[6"]
152

6"x12"
OPENINGS.
2 REQ.

[88"]
2540

2236
[100"]

2743

3048
[120"]
[108"]
[44"]
1118
[6"]
152

SECTION B
24" x 12" TUF-TITE SCALE:1/60
RISER WITH COVER.
2 REQUIRED
TOP VIEW
SCALE:1/60

24" x12" TUF-TITE


7315
RISER WITH COVER.
[288"] 2 REQUIRED
152 127 2269 152
[6"] [5"] [89 3/8"] [6"]

14
[6"]
152
PL-525
EFFLUENT
FILTER. GENERAL NOTES:
BAFFLE
4" PVC 1. UNITS ARE SEALED WITH BUTYL TAPE
POLYSEAL AT THE JOINTS
CAST-A-SEAL
964 - 4.21" 4" PVC CAP TAP CON
OD-6.9"OD TO WALL w/4" PVC 2. MOBILE CRANE REQUIRED ON SITE TO
TEE GLUE TO CAP UNLOAD THE TANK

2540
[100"]
3. ALL UNITS MUST BE HANDLED WITH

[85"]
2159
PROPER LIFTING EQUIPMENT (I.E.
[82"]
2083

SPREADER BAR)

4. SCHEMATIC ONLY (FURTHER DETAILS


UPON REQUEST)

5. MAXIMUM BURIAL DEPTH=30"


[6"]
152

SECTION A
SCALE:1/60

CONCRETE: 45MPa/6500PSI CSA APPROVED DRAWN BY:


AIR ENTRAINMENT: 6-8% WEIGHT: 39,000lbs / 17,690kg (TOP) S.RIMLAND 36300 LITRES SEPTIC
MEETS CAN/CSA-B66-00 39,000lbs / 17,690kg (BOTTOM) 8000 IMPERIAL GALLON TANK
MANUFACTURED:
OTTAWA, ON REINFORCEMENT: MEETS G30.14-M1983 DATE:
8,000 IMPERIAL GALLON / 36,300 LITRES SEPTIC TANK.
1-800-655-3430 JAN/2018
7315
[288"] 3048
203 4574 203 2132 203
[8"] [120"]
[8"] [180 1/8"] [83 7/8"] [8"]

2"X45"OPENING
PL-525 EFFLUENT
FILTER
[60"]
1524

6"X12"
OPENING. 2
REQUIRED

2642

3048
[120"]
[104"]
2997
[118"]

[58"]
1473

TUFF TITE 24" COVER

[8"]
WITH 12"X24" RISER 2

203
REQUIRED (TYP.)
SECTION B
TOP VIEW SCALE:1/60
SCALE:1/60

15
INLET 4" PVC
POLYSEAL
7315
[288"]
203
[8"]

OUTLET 4" PVC


POLYSEAL
PL-525 EFFLUENT
FILTER

4"PVC CAP TAP CON GENERAL NOTES:


TO WALL w/4" PVC
TEE GLUE TO CAP 1. CONCRETE TO BE 45MPa/6,500 P.S.I.

2997
[118"]
76

2616
2565

[103"]
2. BURIAL DEPTH= 30"
[101"]

[3"]

SECTION A

170
SCALE:1/60

[6 3/4"]
CONCRETE: 45MPa / 6,500PSI CSA APPROVED DRAWN BY:
AIR ENTRAINMENT: 6-8% WEIGHT: 50,700lbs / 23,000kg (TOP) S.RIMLAND 45500 LITRES SEPTIC
MEETS CAN/CSA-B66-00 50,700lbs / 23,000kg (BOTTOM) 10,000 IMPERIAL GALLON TANK
MANUFACTURED:
OTTAWA, ON REINFORCEMENT: MEETS G30.14-M1983 DATE:
10,000 IMPERIAL GALLON / 45,500 LITRES SEPTIC TANK
1-800-655-3430 JAN/2018
9145
[360"]
203 203 2745 203 3660
[8"] [8"] [108 1/8"] [8"] (TYP) [144 1/8"]

12" x 4" OPENING


(TYP.)

833

1250
PL-525 EFFLUENT

[49 1/4"]
[32 3/4"] FILTER
2 REQUIRED

3660
6" X 20" OPENING

[144 1/8"]
2 REQUIRED (TYP.)

1800
TUFF- TITE 12" X 24" TUFF- TITE 12" X 24" EZset 12" X 30" RISER

[70 7/8"]
WITH COVER WITH COVER WITH COVER
2 REQUIRED 2 REQUIRED 1 REQUIRED

SECTION B
TOP VIEW SCALE:1/30
SCALE:1/30
9145
[360"]
EZset 12" X 30" RISER
WITH COVER
1 REQUIRED

16
4" PVC
12" X 4" OPENING OUTLET
4" PVC INLET
(TYP.)

203

1047
NOTE 5

[41 1/4"]
[8"](TYP.)
GENERAL NOTES:
77
1. CONCRETE TO BE 45MPa/6,500 P.S.I.

3050
[3"]

[120 1/8"]
2670
2600

2. REINFORCEMENT TO CONFORM TO

[105 1/8"]
[102 3/8"]

CSA-G30.12-400Pa

203 203 3. BURIAL DEPTH: 30"

[8"](TYP.) [8"] 4. REINFORCEMENT

TANK: 20M @ 150 O/C BOTH WAYS


LID: 20M @ 150 O/C BOTH WAYS

5. 4" PVC SUPPORT PIPE FOR


EFFLUENT FILTER NOT PROVIDED

203
SECTION A

[8"](TYP.)
SCALE:1/30

CONCRETE: 45MPa / 6,500PSI CPA CERTIFIED DRAWN BY:


AIR ENTRAINMENT: 6-8% S.RIMLAND 68200 LITRES SEPTIC
WEIGHT: 63,150lbs/28,645kg (TOP)
MEETS CAN/CSA-B66-00 15000 IMPERIAL GALLON TANK
MANUFACTURED: 81,625lbs/37,025kg (BOTTOM) DATE:
OTTAWA, ON REINFORCEMENT : STEEL TO CSA CAN
JAN / 2018 15,000 IMPERIAL GALLON / 68,200 LITRES
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa
9145 3660
[360"] [144 1/8"]
203 203 2745 203
[8"] [8"] [108 1/8"] [8"] (TYP)

12"x 4" OPENING


(TYP.)

203
[8"](TYP.)

[71"]
1804
838 PL-525 EFFLUENT
[33"] FILTER. 2 REQ.

3660
152

[144 1/8"]
[6"](TYP.) 6"x 20"
OPENING
TUFF- TITE 12" X 24" TUFF- TITE 12" X 24" (TYP.)
EZset 12" X 30" RISER
WITH COVER WITH COVER
WITH COVER
[71"]
1804
2 REQUIRED 2 REQUIRED
1 REQUIRED 203
[8"](TYP.)

TOP VIEW SECTION B


203

17
SCALE:1/30 SCALE:1/30
[8"](TYP.)

9145
CAST-A-SEAL [360"]
964 - 4.21" EZset 12" X 30" RISER
OD-6.9"OD WITH COVER
1 REQUIRED
4" PVC
OUTLET

NOTE 5

GENERAL NOTES:

1. CONCRETE TO BE 45MPa/6,500 P.S.I.

3607
[142"]
77

3230
3150
[124"]

[3"] 2. REINFORCEMENT TO CONFORM TO

[127 1/8"]
CSA-G30.12-400Pa

3. BURIAL DEPTH: 30"

4. REINFORCEMENT

TANK: 20M @ 150 O/C BOTH WAYS


LID: 20M @ 150 O/C BOTH WAYS

5. 4" PVC SUPPORT PIPE FOR


SECTION A EFFLUENT FILTER NOT PROVIDED
SCALE:1/30

CONCRETE: 45MPa / 6,500PSI CPA CERTIFIED DRAWN BY:


AIR ENTRAINMENT: 6-8% WEIGHT: 81,065lbs/36,770kg (TOP) S.RIMLAND 86000 LITRES SEPTIC
MEETS CAN/CSA-B66-00 18900 IMPERIAL GALLON TANK
MANUFACTURED: 81,625lbs/37,025kg (BOTTOM)
REINFORCEMENT : STEEL TO CSA CAN DATE:
OTTAWA, ON
JAN / 2018 18,900 IMPERIAL GALLON / 86,000 LITRES
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa
GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL TAPE AT


THE JOINTS

2. DELIVERY IS MADE BY CRANE-EQUIPPED


TRUCKS

3" DIAL CORD SEAL 3. EXCAVATION MUST BE READY, SAFE AND


ACCESSIBLE FOR UNLOADING FROM THE
REAR OF THE TRUCK.

4. MIN OVERHEAD CLEARANCE OF 18FT IS


REQUIRED

914
[36"]
[42"]
1067
5. ALL UNITS MUST BE HANDLED WITH
PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE IN


FIRM SOIL AWAY FROM ANY VEHICULAR
TRAFFIC

TOP VIEW
SCALE:1/16

18
3" DIAL CORD SEAL

24" x 6" TUF-TITE


RISER WITH COVER
1 REQUIRED

76
[3"]
4" INLET PVC 4" OUTLET PVC
POLYSEAL POLYSEAL

889
[35"]
737
[29"]

597
584
[23"]

[23 1/2"]
51
[2"]
SECTION A
SCALE:1/16

CONCRETE: 35MPa/5000PSI WEIGHT: DRAWN BY:


AIR ENTRAINMENT: 6-8% 1,460lbs / 662kg S.RIMLAND 364 LITRES PUMP TANK
80 IMPERIAL GALLON
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN CPA CERTIFIED
BROOKLIN, ON DATE:
A23.1 /A23.3 G30.18 Fy=400MPa MEETS CSA-BB6-00
JAN/2018
80 IMPERIAL GALLON / 364 LITRES PUMP TANK
1-800-655-3430
1346
[53"] GENERAL NOTES:
76
1. UNITS ARE SEALED WITH BUTYL TAPE AT
[3"] (TYP.) THE JOINTS

2. DELIVERY IS MADE BY CRANE-EQUIPPED


TRUCKS

3. EXCAVATION MUST BE READY, SAFE AND


3" DIAL CORD SEAL

76
ACCESSIBLE FOR UNLOADING FROM THE
REAR OF THE TRUCK.

[3"] (TYP.)
4. MIN OVERHEAD CLEARANCE OF 18FT IS
REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

[50"]
1270
6. MAXIMUM BURIAL DEPTH = 1 METRE IN
FIRM SOIL AWAY FROM ANY VEHICULAR
TRAFFIC
4" INLET 2" OUTLET
CAST-A-SEAL 402 CAST-A-SEAL 402
*WILL BE CONVERTING TO A 2" CAST-A-SEAL OUTLET FOR 2018*

3" DIAL CORD SEAL

76
[3"] (TYP.)
680 & 1365 LITRES TOP VIEW 24" x 6" TUF-TITE
RISER WITH COVER
SCALE: 1/20

3" DIAL CORD SEAL

76

19
[3"]
24" x 6" TUF-TITE
RISER WITH COVER

1359
[53 1/2"]
[45"]
1143
[43"]
1092

838
[33"]
621
594
76

[24 1/2"]
[23 1/2"]
[3"] (TYP.)

88 1346
[3 1/2"] 1346
[53"]
[53"]
680 LITRES SECTION A 1365 LITRES SECTION A
SCALE: 1/20 SCALE: 1/20

CONCRETE: 35MPa at 28 days/5000PSI CPA CERTIFIED DRAWN BY: PUMP


AIR ENTRAINMENT: 6-8% WEIGHT: S.RIMLAND 680 & 1365 LITRES
150 & 300 IMPERIAL GALLON TANK
MANUFACTURED: MEETS CAN/CSA-B66-00 680 LITRES- 2,520 lbs / 1,143kg
DATE:
BROOKLIN, ON REINFORCEMENT: STEEL TO CSA CAN 1365 LITRES- 3,560 lbs / 1,614kg
JAN/2018 150 & 300 IMPERIAL GALLON / 680 & 1365 LITRES
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa
2438
[96"]
3" DIAMETER GENERAL NOTES:
CORD SEAL
1. UNITS ARE SEALED WITH BUTYL TAPE
AT THE JOINTS

2. DELIVERY IS MADE BY
CRANE-EQUIPPED TRUCKS

3. EXCAVATION MUST BE READY, SAFE


AND ACCESSIBLE FOR UNLOADING
FROM THE REAR OF THE TRUCK.

[48"]
1219
4. MIN OVERHEAD CLEARANCE OF 18FT
IS REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE IN


24" x 6" TUF-TITE FIRM SOIL AWAY FROM ANY
RISER WITH COVER TOP VIEW VEHICULAR TRAFFIC
2 REQUIRED (TYP.)
SCALE:1/30
*WILL BE CONVERTING TO A 2" CAST-A-SEAL OUTLET FOR 2018*

3" DIAMETER 24" x 6" TUF-TITE RISER 24" x 6" TUF-TITE RISER 3" DIAMETER
CORD SEAL WITH COVER. 2 REQUIRED WITH COVER. 2 REQUIRED CORD SEAL
2386 1142
[94"] [45"]
4" INLET
CAST-A-SEAL 402

20
76
[3"]

4" INLET
2" OUTLET CAST-A-SEAL 402
CAST-A-SEAL 402

[64"]
[64"]

1625
1625

[53"]
[53"]

1346
1346

[51"]
1295

737
[29"]
813
[32"]

76 76 76

76
[3"]
[3"] [3"] [3"]
2438 1219
[96"] [48"]

SECTION A SECTION B
SCALE:1/30 SCALE:1/30

CONCRETE: 35MPa at 28 days/5000PSI UNIT WEIGHT: 5,720lbs DRAWN BY:


AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 2700 LITRES PUMP TANK
MANUFACTURED: 600 IMPERIAL GALLON
REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-BB6-00
BROOKLIN, ON DATE:
A23.1 /A23.3 G30.18 Fy=400MPa
1-800-655-3430 JAN/2018 600 IMPERIAL GALLON / 2,700 LITRES
2543
[100"] 3" DIAMETER
CORD SEAL
GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL TAPE AT


THE JOINTS

2. DELIVERY IS MADE BY CRANE-EQUIPPED


TRUCKS

3. EXCAVATION MUST BE READY, SAFE AND


ACCESSIBLE FOR UNLOADING FROM THE
REAR OF THE TRUCK.

[66"]
1679
4. MIN OVERHEAD CLEARANCE OF 18FT IS
REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE IN


FIRM SOIL AWAY FROM ANY VEHICULAR
TRAFFIC

24" x 6" TUF-TITE


*WILL BE CONVERTING TO A 2" CAST-A-SEAL OUTLET FOR 2018*
RISER WITH COVER TOP VIEW
2 REQUIRED SCALE:1/30

3" DIAMETER 24" x 6" TUF-TITE RISER 3" DIAMETER


24" x 6" TUF-TITE RISER
CORD SEAL WITH COVER. 2 REQUIRED CORD SEAL
WITH COVER. 2 REQUIRED
2467 1603
[97"] [63"]
4" INLET
CAST-A-SEAL 402

21
OPTIONAL INLET
4" PVC POLYSEAL
2" OUTLET
CAST-A-SEAL 402
[59"]
1498

[56"]
1422
[46"]
1167
[44"]
1117

635
[25"]
711
[28"]

76
[3"]

76 76 76

[3"]
76
[3"] [3"] [3"]
2543 1679
[100"] [66"]
SECTION A SECTION B
SCALE:1/30 SCALE:1/30
CONCRETE: 35MPa at 28 days/5000PSI UNIT WEIGHT: 6,940lbs / 3,147kg DRAWN BY:
AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 3600 LITRES LOW HEIGHT
800 IMPERIAL GALLON PUMP TANK
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-B66
BROOKLIN, ON DATE:
A23.1 /A23.3 G30.18 Fy=400MPa
JAN/2018 800 IMPERIAL GALLON / 3,600 LITRES
1-800-655-3430
2540
[100"]
3" DIAMETER GENERAL NOTES:
CORD SEAL
1. UNITS ARE SEALED WITH BUTYL TAPE AT
THE JOINTS

2. DELIVERY IS MADE BY CRANE-EQUIPPED


TRUCKS

3. EXCAVATION MUST BE READY, SAFE AND


ACCESSIBLE FOR UNLOADING FROM THE
REAR OF THE TRUCK.

[54"]
1372
4. MIN OVERHEAD CLEARANCE OF 18FT IS
REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE IN


FIRM SOIL AWAY FROM ANY VEHICULAR
TRAFFIC

24" x 6" TUF-TITE


RISER WITH COVER TOP VIEW *WILL BE CONVERTING TO A 2" CAST-A-SEAL OUTLET FOR 2018*
2 REQUIRED SCALE:1/30
3" DIAMETER 24" x 6" TUF-TITE RISER 3" DIAMETER
24" x 6" TUF-TITE RISER
CORD SEAL WITH COVER. 2 REQUIRED CORD SEAL
WITH COVER. 2 REQUIRED 2438 1270
[96"] [50"]

22
4" INLET
CAST-A-SEAL 402

OPTIONAL INLET
4" PVC POLYSEAL 2" OUTLET
CAST-A-SEAL 402
[70"]
1778

[67"]
1702
[58"]
1470
[56"]
1422

775
851

[30 1/2"]
[33 1/2"]

76
[3"]

76 76 76

[3"]
76
[3"] [3"] [3"]
2540 1372
[100"] [54"]
SECTION A SECTION B
SCALE:1/30 SCALE:1/30

CONCRETE: 35MPa at 28 days / 5000PSI UNIT WEIGHT: 6,490lbs / 2,943kg DRAWN BY:
AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 3600 LITRES PUMP TANK
800 IMPERIAL GALLON
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-B66
BROOKLIN, ON DATE:
A23.1 /A23.3 G30.18 Fy=400MPa 800 IMPERIAL GALLON / 3,600 LITRES
1-800-655-3430 JAN / 2018
2972
[117"]

GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL TAPE AT


3" DIAMETER THE JOINTS
CORD SEAL
2. DELIVERY IS MADE BY CRANE-EQUIPPED
TRUCKS

3. EXCAVATION MUST BE READY, SAFE AND


ACCESSIBLE FOR UNLOADING FROM THE
REAR OF THE TRUCK.

4. MIN OVERHEAD CLEARANCE OF 18FT IS


REQUIRED

[86"]
2184
5. ALL UNITS MUST BE HANDLED WITH
PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE IN


FIRM SOIL AWAY FROM ANY VEHICULAR
TRAFFIC

*WILL BE CONVERTING TO A 2" CAST-A-SEAL OUTLET FOR 2018*

24" x 6" TUF-TITE


RISER WITH COVER TOP VIEW
2 REQUIRED
SCALE:1/30

3" DIAMETER 24" x 6" TUF-TITE RISER 24" x 6" TUF-TITE RISER 3" DIAMETER
CORD SEAL WITH COVER. 2 REQUIRED WITH COVER. 2 REQUIRED CORD SEAL
2870 2082

23
[113"] [82"]
4" INLET
CAST-A-SEAL 402

OPTIONAL INLET
4" PVC POLYSEAL 2" OUTLET
CAST-A-SEAL 402
[54"]
1371

[51"]
1295
[42"]
1067
[40"]
1016
648
[25 1/2"]

76
76

[3"]
[3"]

76 76
[3"] (TYP.) SECTION A [3"] SECTION B
SCALE:1/30 SCALE:1/30

CONCRETE: 35MPa at 28 days / 5000PSI UNIT WEIGHT: 11,620 lbs DRAWN BY:
CPA CERTIFIED S.RIMLAND
LOW HEIGHT
AIR ENTRAINMENT: 6-8% 4500 LITRES
1000 IMPERIAL GALLON PUMP TANK
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-BB6-00
BROOKLIN, ON DATE:
A23.1 /A23.3 G30.18 Fy=400MPa
JAN/2018 1000 IMPERIAL GALLON / 4,500 LITRES
1-800-655-3430
2540
[100"]
GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL TAPE AT


THE JOINTS

3" DIAMETER 2. DELIVERY IS MADE BY CRANE-EQUIPPED


CORD SEAL TRUCKS

3. EXCAVATION MUST BE READY, SAFE AND


ACCESSIBLE FOR UNLOADING FROM THE
REAR OF THE TRUCK.

4. MIN OVERHEAD CLEARANCE OF 18FT IS

[66"]
1676
REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE IN


FIRM SOIL AWAY FROM ANY VEHICULAR
TRAFFIC

*WILL BE CONVERTING TO A 2" CAST-A-SEAL OUTLET FOR 2018*


24" x 6" TUF-TITE
RISER WITH COVER TOP VIEW
2 REQUIRED
SCALE:1/30

3" DIAMETER 24" x 6" TUF-TITE RISER WITH 24" x 6" TUF-TITE RISER WITH 3" DIAMETER
2450 CORD SEAL COVER. 2 REQUIRED COVER. 2 REQUIRED 1586 CORD SEAL

24
[96 1/2"] [62 1/2"]

76
4" INLET
CAST-A-SEAL 402

[3"](TYP.)
OPTIONAL INLET
4" PVC POLYSEAL 2" OUTLET
CAST-A-SEAL 402
[69"]
1752

[66"]
[66"]

1676
1676

[58"]
1472
[56"]
1420
838
[33"]

76
76

[3"]
[3"]

76 76
[3"] (TYP.) [3"](TYP.)
SECTION A SECTION B
SCALE:1/30 SCALE:1/30

CONCRETE: 35MPa at 28 days / 5000PSI UNIT WEIGHT: 8,200lbs DRAWN BY:


AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 4500 LITRES PUMP TANK
1000 IMPERIAL GALLON
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-BB6-00
BROOKLIN, ON A23.1 / A23.3. G30.18 Fy=400MPa DATE:
JAN/2018 1000 IMPERIAL GALLON / 4,500 LITRES
1-800-655-3430
3001
[118 1/8"]
10M LIFTING ANCHOR 3" DIAMETER
4 REQUIRED (TYP.) CORD SEAL
GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL TAPE AT


THE JOINTS

2. DELIVERY IS MADE BY CRANE-EQUIPPED


TRUCKS

3. EXCAVATION MUST BE READY, SAFE AND


ACCESSIBLE FOR UNLOADING FROM THE
REAR OF THE TRUCK.

4. MIN OVERHEAD CLEARANCE OF 18FT IS


REQUIRED

5. ALL UNITS MUST BE HANDLED WITH

2290
PROPER LIFTING EQUIPMENT (I.E.

[90 1/8"]
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE IN


FIRM SOIL AWAY FROM ANY VEHICULAR
TRAFFIC

*WILL BE CONVERTING TO A 2" CAST-A-SEAL OUTLET FOR 2018*

24" x 6" TUF-TITE


RISER WITH COVER TOP VIEW 3" DIAMETER
2 REQUIRED CORD SEAL
SCALE:1/30
24" x 6" TUF-TITE 10M LIFTING ANCHOR
4" INLET OPTIONAL INLET 24" x 6" TUF-TITE RISER WITH COVER 4 REQUIRED (TYP.)
CAST-A-SEAL 402 4" PVC POLYSEAL RISER WITH COVER 2 REQUIRED

25
2 REQUIRED

2" OUTLET
140

CAST-A-SEAL 402
[5 1/2"]

[63"]
1613

1601
[63 1/2"]

[53"]
1346
[50"]
1269

74 25
SECTION A [2 7/8"] [1"]
SECTION B
SCALE:1/30 SCALE:1/30
CONCRETE: 35MPa at 28 days/5000PSI UNIT WEIGHT: 13,400 lbs DRAWN BY:
AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 6135 LITRES PUMP TANK
1350 IMPERIAL GALLON
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-BB6-00
BROOKLIN, ON DATE:
A23.1 /A23.3 G30.18 Fy=400MPa
JAN/2018
1350 IMPERIAL GALLON / 6,135 LITRES
1-800-655-3430
3213
GENERAL NOTES:
[126"] 3" DIAMETER
CORD SEAL 1. UNITS ARE SEALED WITH BUTYL TAPE AT
THE JOINTS

2. DELIVERY IS MADE BY CRANE-EQUIPPED


TRUCKS

3. EXCAVATION MUST BE READY, SAFE AND


ACCESSIBLE FOR UNLOADING FROM THE
REAR OF THE TRUCK.

4. MIN OVERHEAD CLEARANCE OF 18FT IS


REQUIRED

5. ALL UNITS MUST BE HANDLED WITH

2553
PROPER LIFTING EQUIPMENT (I.E.

[101"]
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE IN


FIRM SOIL AWAY FROM ANY VEHICULAR
TRAFFIC

10M LIFTING *WILL BE CONVERTING TO A 2" CAST-A-SEAL OUTLET FOR 2018*


ANCHOR.
4 REQUIRED (TYP)

24" x 6" TUF-TITE


RISER WITH COVER
2 REQUIRED
TOP VIEW
SCALE:1/40

26
3" DIAMETER
CORD SEAL
2911
24" x 6" TUF-TITE 10M LIFTING
[114 5/8"] RISER WITH COVER ANCHOR
2 REQUIRED 4 REQUIRED (TYP)
4" INLET OPTIONAL INLET 24" x 6" TUF-TITE
CAST-A-SEAL 402 4" PVC POLYSEAL RISER WITH COVER
2 REQUIRED

2" OUTLET
CAST-A-SEAL 402
108
[4 1/4"]

2214

1581
1581

[87 1/8"]

[62 1/4"]
[62 1/4"]

[52"]
1321
[50"]
1270

76
76

[3"](TYP.)
[3"](TYP.)

76 76
[3"](TYP.) [3"](TYP.)

SECTION A SECTION B
SCALE:1/40 SCALE:1/40

CONCRETE: 35MPa at 28 days/5000PSI UNIT WEIGHT: 14,460 lbs DRAWN BY:


AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 7000 LITRES PUMP TANK
1550 IMPERIAL GALLON
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN MEETS CSA-BB6-00
BROOKLIN, ON DATE:
A23.1 /A23.3 G30.18 Fy=400MPa 1550 IMPERIAL GALLON / 7,000 LITRES
1-800-655-3430 JAN/2018
4039
[159"]

GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL


TAPE AT THE JOINTS

3" DIAMETER 2. DELIVERY IS MADE BY


CORD SEAL CRANE-EQUIPPED TRUCKS

3. EXCAVATION MUST BE READY, SAFE


AND ACCESSIBLE FOR UNLOADING
FROM THE REAR OF THE TRUCK.

[90"]
2286
4. MIN OVERHEAD CLEARANCE OF
18FT IS REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)
10M LIFTING
ANCHOR. 6. MAXIMUM BURIAL DEPTH = 1 METRE
4 REQUIRED (TYP) IN FIRM SOIL AWAY FROM ANY
VEHICULAR TRAFFIC

*WILL BE CONVERTING TO A 2" CAST-A-SEAL OUTLET FOR 2018*

24" x 6" TUF-TITE


RISER WITH COVER TOP VIEW
2 REQUIRED SCALE:1/40

10M LIFTING
4" INLET 3" DIAMETER 24" x 6" TUF-TITE ANCHOR
24" x 6" TUF-TITE
CAST-A-SEAL 402 CORD SEAL RISER WITH COVER 4 REQUIRED (TYP)

27
RISER WITH COVER
2 REQUIRED
2 REQUIRED

[5"]
127
OPTIONAL INLET
4" PVC POLYSEAL 2" OUTLET
CAST-A-SEAL 402
[58"]

[58"]
1473

1473
1232
1181

[48 1/2"]
76
[46 1/2"]

76

[3"](TYP.)
[3"](TYP.)

76 76
[3"](TYP.) [3"](TYP.)

SECTION A SECTION B
SCALE:1/40 SCALE:1/40

CONCRETE: 35MPa/5000PSI WEIGHT: DRAWN BY: LOW HEIGHT


AIR ENTRAINMENT: 6-8% 17,250lbs / 7,825kg S.RIMLAND 7500 LITRES
1650 IMPERIAL GALLON PUMP TANK
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN CPA CERTIFIED
BROOKLIN, ON MEETS CSA-BB6-00 DATE:
A23.1 /A23.3 G30.18 Fy=400MPa
1-800-655-3430 JAN/2018 1650 IMPERIAL GALLON / 7,500 LITRES
4039
INLET 4" PVC [159"] 3" DIAMETER GENERAL NOTES:
POLYSEAL INLET CORD SEAL
ON LID 1. UNITS ARE SEALED WITH BUTYL
TAPE AT THE JOINTS

2. DELIVERY IS MADE BY
CRANE-EQUIPPED TRUCKS

3. EXCAVATION MUST BE READY, SAFE


AND ACCESSIBLE FOR UNLOADING
FROM THE REAR OF THE TRUCK.

4. MIN OVERHEAD CLEARANCE OF


18FT IS REQUIRED

5. ALL UNITS MUST BE HANDLED WITH

[90"]
2286
PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE

[60"]
1524
IN FIRM SOIL AWAY FROM ANY
VEHICULAR TRAFFIC
10M LIFTING
ANCHOR.
4 REQUIRED (TYP)

24" x 6" TUF-TITE


RISER WITH COVER TOP VIEW

28
2 REQUIRED SCALE:1/40

24" x 6" TUF-TITE 3" DIAMETER 10M LIFTING


24" x 6" TUF-TITE 3" DIAMETER RISER WITH COVER CORD SEAL ANCHOR
4" INLET
RISER WITH COVER CORD SEAL 2 REQUIRED 4 REQUIRED (TYP)
CAST-A-SEAL 402

[5"]
2 REQUIRED

127
OPTIONAL INLET
4" OUTLET PVC
4" PVC POLYSEAL
POLYSEAL
4" INLET
*9,000 LITRES TO ROOF*
CAST-A-SEAL 402
[58"]

[58"]
1473

1472
[48"]
1219
[46"]
1168
76

76
[3"](TYP.)

[3"](TYP.)
76 76
[3"](TYP.) [3"](TYP.)
SECTION A SECTION B
SCALE:1/40 SCALE:1/40

CONCRETE: 35MPa/5000PSI WEIGHT: DRAWN BY: LOW HEIGHT


AIR ENTRAINMENT: 6-8% 16,050lbs / 7,280kg S.RIMLAND 9000 LITRESSINGLE
MANUFACTURED:
CHAMBER
2000 IMPERIAL GALLON
REINFORCEMENT: STEEL TO CSA CAN CPA CERTIFIED
BROOKLIN, ON DATE:
A23.1 /A23.3 G30.18 Fy=400MPa MEETS CSA-BB6-00 2,000 IMPERIAL GALLON / 9,000 LITRES SINGLE CHAMBER
1-800-655-3430 JAN/2018
4039
[159"]
24" x 6" TUF-TITE
RISER WITH COVER
2 REQUIRED
GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL


TAPE AT THE JOINTS
3" DIAM.
CORD SEAL 2. DELIVERY IS MADE BY
CRANE-EQUIPPED TRUCKS

3. EXCAVATION MUST BE READY, SAFE


AND ACCESSIBLE FOR UNLOADING
FROM THE REAR OF THE TRUCK.

[90"]
2286
4. MIN OVERHEAD CLEARANCE OF
18FT IS REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)
10M LIFTING
ANCHOR. 6. MAXIMUM BURIAL DEPTH = 1 METRE
4 REQUIRED (TYP) IN FIRM SOIL AWAY FROM ANY
VEHICULAR TRAFFIC

TOP VIEW
SCALE:1/40

3" DIAMETER
CORD SEAL

24" x 6" TUF-TITE 3" DIAMETER 24" x 6" TUF-TITE 10M LIFTING
4" INLET OPTIONAL INLET RISER WITH COVER CORD SEAL RISER WITH COVER ANCHOR
CAST-A-SEAL 402 4" PVC POLYSEAL 2 REQUIRED 2 REQUIRED 4 REQUIRED (TYP)

[5"]
127

29
4" OUTLET PVC
POLYSEAL
4" INLET
CAST-A-SEAL 402
[66"]

[66"]
1677

1677
[56"]
1423
[54"]
1372

76
76

[3"](TYP.)
[3"](TYP.)

76 76
[3"](TYP.) [3"](TYP.)
SECTION A SECTION B
SCALE:1/40 SCALE:1/40

CONCRETE: 35MPa at 28 days/5000PSI WEIGHT: DRAWN BY:


S.RIMLAND
SINGLE
AIR ENTRAINMENT: 6-8% 17,895lbs / 8,120kg 9000 LITRES
2000 IMPERIAL GALLON CHAMBER
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN CPA CERTIFIED
BROOKLIN, ON MEETS CSA-BB6-00 DATE:
A23.1 /A23.3 G30.18 Fy=400MPa
2,000 IMPERIAL GALLON / 9,000 LITRES SINGLE CHAMBER
1-800-655-3430 JAN/2018
5055
[199"]

GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL


TAPE AT THE JOINTS
3" DIAMETER
CORD SEAL 2. DELIVERY IS MADE BY
CRANE-EQUIPPED TRUCKS

3. EXCAVATION MUST BE READY, SAFE


AND ACCESSIBLE FOR UNLOADING
FROM THE REAR OF THE TRUCK.

2591
[102"]
4. MIN OVERHEAD CLEARANCE OF
18FT IS REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE


IN FIRM SOIL AWAY FROM ANY
VEHICULAR TRAFFIC
TUFF TITE 24" COVER
WITH 12"X24" RISER
2 REQUIRED (TYP.)
TOP VIEW
SCALE:1/50

30
TUFF TITE 24" COVER TUFF TITE 24" COVER 3" DIAMETER
4" INLET WITH 12"X24" RISER 3" DIAMETER WITH 12"X24" RISER CORD SEAL
CAST-A-SEAL 402 2 REQUIRED (TYP.) CORD SEAL 2 REQUIRED (TYP.)

[5"]
127
OPTIONAL INLET
4" OUTLET PVC
4" PVC POLYSEAL
POLYSEAL
127 4" INLET
CAST-A-SEAL 402
[5"]
[60"]

[59"]
1524

1499
[47"]
1194
[45"]
1143

87

108
108

[4 1/4"]
[4 1/4"]

[3 3/8"]

5055 2591
[199"] [102"]

SECTION A SECTION B
SCALE:1/50 SCALE:1/50

CONCRETE: 35MPa at 28 days/5000PSI WEIGHT: 27,180lbs / 12,330kg DRAWN BY: SINGLE


AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 11365 LITRES
2500 IMPERIAL GALLON CHAMBER
MANUFACTURED: MEETS CAN/CSA-B66-00
BROOKLIN, ON REINFORCEMENT: STEEL TO CSA CAN DATE:
2,500 IMPERIAL GALLON / 11,365 LITRES SINGLE CHAMBER
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018
5055
[199"]

GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL


TAPE AT THE JOINTS
3" DIAM.
CORD SEAL 2. DELIVERY IS MADE BY
CRANE-EQUIPPED TRUCKS

3. EXCAVATION MUST BE READY, SAFE


AND ACCESSIBLE FOR UNLOADING
FROM THE REAR OF THE TRUCK.

2591
[102"]
4. MIN OVERHEAD CLEARANCE OF
18FT IS REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE


IN FIRM SOIL AWAY FROM ANY
VEHICULAR TRAFFIC
TUFF TITE 24" COVER
WITH 6"X24" RISER
2 REQUIRED (TYP.)
TOP VIEW
SCALE:1/50

4" INLET TUFF TITE 24" COVER 3" DIAMETER TUFF TITE 24" COVER 3" DIAMETER
CAST-A-SEAL 402 WITH 6"X24" RISER CORD SEAL WITH 6"X24" RISER CORD SEAL
2 REQUIRED (TYP.) 2 REQUIRED (TYP.)

31
108
[4 1/4"]
OPTIONAL INLET
4" OUTLET
4" PVC POLYSEAL
PVC POLYSEAL
864
[34"]

4" INLET
CAST-A-SEAL 402

127

[68"]
1727
1435
[5"]

1383

[56 1/2"]
[54 1/2"]
86
864
[34"]

108
108

[3 3/8"]

[4 1/4"]
[4 1/4"]

5055 2591
[199"] [102"]

SECTION A SECTION B
SCALE:1/50 SCALE:1/50

CONCRETE: 35MPa at 28 days / 5000PSI WEIGHT: 26,142lbs / 11,857kg DRAWN BY: SINGLE
AIR ENTRAINMENT: 5-8% S.RIMLAND 13650 LITRES
CPA CERTIFIED 3,000 IMPERIAL GALLON CHAMBER
MANUFACTURED: MEETS CAN/CSA-B66-00
BROOKLIN, ON DATE:
REINFORCEMENT: STEEL TO CSA CAN
3,000 IMPERIAL GALLON / 13,650 LITRES SINGLE CHAMBER
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018
5055
[199"]

GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL


TAPE AT THE JOINTS
3" DIAMETER
CORD SEAL 2. DELIVERY IS MADE BY
CRANE-EQUIPPED TRUCKS

3. EXCAVATION MUST BE READY, SAFE


AND ACCESSIBLE FOR UNLOADING
FROM THE REAR OF THE TRUCK.

2591
[102"]
4. MIN OVERHEAD CLEARANCE OF
18FT IS REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE


IN FIRM SOIL AWAY FROM ANY
VEHICULAR TRAFFIC
TUFF TITE 24" COVER
WITH 6"X24" RISER
2 REQUIRED (TYP.)
TOP VIEW
SCALE:1/50

32
OPTIONAL INLET 3" DIAMETER TUFF TITE 24" COVER TUFF TITE 24" COVER 3" DIAMETER
4" INLET 4" PVC POLYSEAL CORD SEAL WITH 6"X24" RISER WITH 6"X24" RISER CORD SEAL
CAST-A-SEAL 402 2 REQUIRED (TYP.) 2 REQUIRED (TYP.)

108
[4 1/4"]
4" OUTLET PVC
POLYSEAL
4" INLET
CAST-A-SEAL 402

2096
2096

127

[82 1/2"]
[82 1/2"]

1810
1759

[71 1/4"]
[69 1/4"]

[5"]

86

108
108

[3 3/8"]

[4 1/4"]
[4 1/4"]

5055 2591
[199"] [102"]

SECTION A SECTION B
SCALE:1/50 SCALE:1/50

CONCRETE: 35MPa at 28 days / 5000PSI WEIGHT: 31,140lbs / 14,125kg DRAWN BY:


AIR ENTRAINMENT: 6-8% BOTTOM: 15,780lbs S.RIMLAND 18000 LITRES SINGLE
4000 IMPERIAL GALLON CHAMBER
MANUFACTURED: MEETS CAN/CSA-B66-00 TOP: 15,360lbs
BROOKLIN, ON REINFORCEMENT: STEEL TO CSA CAN DATE:
CPA CERTIFIED 4,000 IMPERIAL GALLON / 18,000 LITRES SINGLE CHAMBER
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018
5055
[199"]

GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL


TAPE AT THE JOINTS
3" DIAMETER
CORD SEAL 2. DELIVERY IS MADE BY
CRANE-EQUIPPED TRUCKS

3. EXCAVATION MUST BE READY,


SAFE AND ACCESSIBLE FOR
UNLOADING FROM THE REAR OF

2591
[102"]
THE TRUCK.

4. MIN OVERHEAD CLEARANCE OF


18FT IS REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE


IN FIRM SOIL AWAY FROM ANY
VEHICULAR TRAFFIC
TUFF TITE 24" COVER
WITH 6"X24" RISER TOP VIEW
2 REQUIRED (TYP.)
SCALE:1/50

4" INLET OPTIONAL INLET 3" DIAMETER TUFF TITE 24" COVER TUFF TITE 24" COVER 3" DIAMETER
CAST-A-SEAL 402 4" PVC POLYSEAL CORD SEAL WITH 6"X24" RISER WITH 6"X24" RISER CORD SEAL
2 REQUIRED (TYP.) 2 REQUIRED (TYP.)

108
[4 1/4"]

33
4" OUTLET PVC
POLYSEAL
4" INLET
CAST-A-SEAL 402

2527
2527

[99 1/2"]
[99 1/2"]

[88"]
2235
[86"]
2184
127
[5"]

86

108
108

[3 3/8"]

[4 1/4"]
[4 1/4"]

5055 2591
[199"] [102"]

SECTION A SECTION B
SCALE:1/50 SCALE:1/50

CONCRETE: 35MPa at 28 days/5000PSI WEIGHT: 34,870lbs / 15,820kg DRAWN BY:


S.RIMLAND
SINGLE
AIR ENTRAINMENT: 6-8% CPA CERTIFIED
22750 LITRES
5000 IMPERIAL GALLON CHAMBER
MANUFACTURED: MEETS CAN/CSA-B66-00
BROOKLIN, ON DATE:
REINFORCEMENT: STEEL TO CSA CAN 5,000 IMPERIAL GALLON / 22,750 LITRES SINGLE CHAMBER
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018
5055
[199"]

GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL TAPE


3" DIAMETER AT THE JOINTS
CORD SEAL
2. DELIVERY IS MADE BY CRANE-EQUIPPED
TRUCKS

3. EXCAVATION MUST BE READY, SAFE


AND ACCESSIBLE FOR UNLOADING
FROM THE REAR OF THE TRUCK.

2591
[102"]
4. MIN OVERHEAD CLEARANCE OF 18FT IS
REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE IN


FIRM SOIL AWAY FROM ANY VEHICULAR
TRAFFIC
TUFF TITE 24" COVER
WITH 6"X24" RISER TOP VIEW
2 REQUIRED (TYP.)
SCALE:1/50

3" DIAMETER TUFF TITE 24" COVER TUFF TITE 24" COVER 3" DIAMETER
4" INLET OPTIONAL INLET CORD SEAL WITH 6"X24" RISER WITH 6"X24" RISER CORD SEAL
CAST-A-SEAL 402 4" PVC POLYSEAL 2 REQUIRED (TYP.) 2 REQUIRED (TYP.)

108

34
[4 1/4"]
4" OUTLET PVC
POLYSEAL
4" INLET
CAST-A-SEAL 402

3251
3251

[128"]
[128"]

2877
2826

[113 1/4"]
[111 1/4"]

127
[5"]

86

108
108

[3 3/8"]

[4 1/4"]
[4 1/4"]

5055 2591
[199"] [102"]

SECTION A SECTION B
SCALE:1/50 SCALE:1/50

CONCRETE: 35MPa at 28 days / 5000PSI WEIGHT: 40,905lbs / 18,555kg DRAWN BY:


AIR ENTRAINMENT: 6-8% S.RIMLAND
SINGLE
CPA CERTIFIED 30000 LITRES
MEETS CAN/CSA-B66-00 6600 IMPERIAL GALLON CHAMBER
MANUFACTURED:
BROOKLIN, ON REINFORCEMENT : STEEL TO CSA CAN DATE:
6,600 IMPERIAL GALLON / 30,000 LITRES SINGLE CHAMBER
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018
7315
[288"] 3048

152 [120"]
152 152
[6"]
3" DIAMETER [6"] 2"X45"OPENING [6"]
CORD SEAL

[6"]
152
[6"]
152

6"x12"
OPENINGS.
2 REQ.
2540
[100"]

3048
[120"]
[44"]
1118

24"X24"
[6"]
152

(600mmX600mm) SECTION B
24" x 12" TUF-TITE KNOCKOUT PANEL. SCALE:1/60
TOP VIEW RISER WITH COVER.
SCALE:1/60 2 REQUIRED

24" x12" TUF-TITE


7315
RISER WITH COVER.
[288"] 2 REQUIRED
152 127 2269 152
[6"] [5"] [89 3/8"] [6"]

35
[6"]
152
4" OUTLET PVC
GENERAL NOTES:
POLYSEAL
BAFFLE
1. UNITS ARE SEALED WITH BUTYL TAPE
CAST-A-SEAL AT THE JOINTS
964 - 4.21"
OD-6.9"OD 2. MOBILE CRANE REQUIRED ON SITE TO
UNLOAD THE TANK

2540
[100"]
3. ALL UNITS MUST BE HANDLED WITH

[85"]
2159
PROPER LIFTING EQUIPMENT
[82"]
2083

4. SCHEMATIC ONLY (FURTHER DETAILS


UPON REQUEST)

5. MAXIMUM BURIAL DEPTH=30"


[6"]
152

SECTION A
SCALE:1/60

CONCRETE: 45MPa/6500PSI CSA APPROVED DRAWN BY:


WEIGHT: 39,000lbs / 17,690kg (TOP) S.RIMLAND
SINGLE
AIR ENTRAINMENT: 6-8% 36300 LITRES
39,000lbs / 17,690kg (BOTTOM) 8000 IMPERIAL GALLON CHAMBER
MANUFACTURED: MEETS CAN/CSA-B66-00
OTTAWA, ON REINFORCEMENT: MEETS G30.14-M1983 DATE:
8,000 IMPERIAL GALLON / 36,300 LITRES SINGLE CHAMBER TANK
1-800-655-3430 JAN/2018
7315
[288"] 3048
203 4574 203 2132 203
[8"] [120"]
[8"] [180 1/8"] [83 7/8"] [8"]

2"X45"OPENING
[60"]
1524

6"X12"
OPENING. 2
REQUIRED

2642

3048
[120"]
[104"]
2997
[118"]

[58"]
1473

TUFF TITE 24" COVER


24"X24"

[8"]
WITH 12"X24" RISER 2

203
(600mmX600mm)
REQUIRED (TYP.)
SECTION B KNOCKOUT PANEL.
TOP VIEW SCALE:1/60
SCALE:1/60

36
INLET 4" PVC
POLYSEAL
7315
[288"]
203
[8"]

OUTLET 4" PVC


POLYSEAL

GENERAL NOTES:

1. CONCRETE TO BE 45MPa/6,500 P.S.I.

2997
[118"]
76

2616
2565

[103"]
2. BURIAL DEPTH= 30"
[101"]

[3"]

SECTION A

170
SCALE:1/60

[6 3/4"]
CONCRETE: 45MPa / 6,500PSI CSA APPROVED DRAWN BY:
AIR ENTRAINMENT: 6-8% WEIGHT: 50,700lbs / 23,000kg (TOP) S.RIMLAND 45500 LITRES SINGLE
MEETS CAN/CSA-B66-00 50,700lbs / 23,000kg (BOTTOM) 10,000 IMPERIAL GALLON CHAMBER
MANUFACTURED:
OTTAWA, ON REINFORCEMENT: MEETS G30.14-M1983 DATE:
10,000 IMPERIAL GALLON / 45,500 LITRES SINGLE CHAMBER TANK
1-800-655-3430 JAN/2018
9145 TUFF- TITE 12" X 24"
[360"] WITH COVER
203 203 2745 203 3 REQUIRED
3660
[8"] [8"] [108 1/8"] [8"] (TYP) [144 1/8"]

12" x 4" OPENING

1250
(TYP.)
TUFF- TITE 12" X 24"

[49 1/4"]
WITH COVER
3 REQUIRED

6"X20"

3660
OPENING. 2

[144 1/8"]
REQUIRED
2' X 2' OPENING
(TYP.)
838

1800
[70 7/8"]
[33"]

SECTION B
TOP VIEW SCALE:1/30
SCALE:1/30

9145
TUFF- TITE 12" X 24" [360"] 447
WITH COVER
[17 5/8"]

37
3 REQUIRED
4" PVC POLYSEAL
12" X 4" OPENING
CAST-A-SEAL 964 -
(TYP.)
4.21" OD-6.9"OD

203
*16,000 IMPERIAL GALLON /

[8"](TYP.)
72,700 LITRES TO ROOF

GENERAL NOTES:
77
1. CONCRETE TO BE 45MPa/6,500 P.S.I.

3050
[3"]

[120 1/8"]
2671
2601

2. REINFORCEMENT TO CONFORM TO

[105 1/8"]
CSA-G30.12-400Pa
[102 3/8"]

3. REINFORCEMENT
203
203 TANK: 20M @ 150 O/C BOTH WAYS
610
[24"]
[8"](TYP.)
[8"] LID: 20M @ 150 O/C BOTH WAYS

SECTION A

203
SCALE:1/30

[8"](TYP.)
CONCRETE: 45MPa / 6,500PSI CPA CERTIFIED DRAWN BY:
AIR ENTRAINMENT: 6-8% S.RIMLAND 72700 LITRES SINGLE
WEIGHT: 63,150lbs/28,645kg (TOP) 16,000 IMPERIAL GALLON CHAMBER
MANUFACTURED: MEETS CAN/CSA-B66-00
81,625lbs/37,025kg (BOTTOM)
OTTAWA, ON REINFORCEMENT : STEEL TO CSA CAN DATE:
16,000 IMPERIAL GALLON / 72,700 LITRES SINGLE CHAMBER TANK
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018
9145 3660
[360"] [144 1/8"]
203 203 2745 203
[8"] [8"] [108 1/8"] [8"] (TYP)

12"x 4" OPENING


(TYP.)

203
[8"](TYP.)
838

[71"]
1804
TUFF- TITE 12" X 24"
WITH COVER [33"]
6"X20"
3 REQUIRED OPENING. 2
REQUIRED

3660
152

[144 1/8"]
[6"](TYP.)
2'x2' OPENING
(TYP.)
[71"]
1804 203
[8"](TYP.)

TOP VIEW SECTION B


203

SCALE:1/30 SCALE:1/30
[8"](TYP.)

38
9145
[360"]
TUFF- TITE 12" X 24"
4" PVC
WITH COVER
INLET
3 REQUIRED
4" PVC
4" PVC INLET OUTLET

91,000 LITRES TO ROOF


20,000 IMPERIAL GALLONS

GENERAL NOTES:

1. CONCRETE TO BE 45MPa/6,500 P.S.I.

3607
[142"]
77

3230
3150
[124"]

[3"] 2. REINFORCEMENT TO CONFORM TO

[127 1/8"]
CSA-G30.12-400Pa

3. BURIAL DEPTH: 30"

KNOCKOUT 4. REINFORCEMENT
PANEL
610
[24"]

TANK: 20M @ 150 O/C BOTH WAYS


LID: 20M @ 150 O/C BOTH WAYS

SECTION A
SCALE:1/30

CONCRETE: 45MPa / 6,500PSI CPA CERTIFIED DRAWN BY:


S.RIMLAND
SINGLE
AIR ENTRAINMENT: 6-8% WEIGHT: 81,065lbs/36,770kg (TOP) 90900 LITRES
20000 IMPERIAL GALLON CHAMBER
MANUFACTURED: MEETS CAN/CSA-B66-00 81,625lbs/37,025kg (BOTTOM) DATE:
OTTAWA, ON REINFORCEMENT : STEEL TO CSA CAN
JAN / 2018 20,000 IMPERIAL GALLON / 90,900 LITRES
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa
5055
[199"]

GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL


TAPE AT THE JOINTS
175mmØ OPENING
FOR DRY HYDRANT 2. DELIVERY IS MADE BY
DIXON-dfh 9140-600 CRANE-EQUIPPED TRUCKS

3. EXCAVATION MUST BE READY, SAFE


AND ACCESSIBLE FOR UNLOADING
FROM THE REAR OF THE TRUCK.

2591
[102"]
4. MIN OVERHEAD CLEARANCE OF 18FT
IS REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
100mm VENT
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE


IN FIRM SOIL AWAY FROM ANY
VEHICULAR TRAFFIC
TUFF TITE 24" COVER
WITH 12"X24" RISER TOP VIEW
2 REQUIRED (TYP.)
SCALE:1/50

39
TUFF TITE 24" COVER DRY HYDRANT
4" INLET 100mm VENT
WITH 12"X24" RISER DIXON-dfh 9140-600

610
[24"]

108
CAST-A-SEAL 402

[4 1/4"]
2 REQUIRED (TYP.)

4" INLET
CAST-A-SEAL
402 4" PVC PIPE
2406

2527
2527

[94 3/4"]

[99 1/2"]
[99 1/2"]

[88"]
2235
127
[5"]

86

108
108

[3 3/8"]

[4 1/4"]
[4 1/4"]

5055 2591
[199"] [102"]

SECTION A SECTION B
SCALE:1/50 SCALE:1/50

*SINGLE FIRE WATER TANK*


CONCRETE: 35MPa/5000PSI WEIGHT: 34,870lbs / 15,820kg DRAWN BY:
AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 22750 LITRES
5000 IMPERIAL GALLON
MANUFACTURED: MEETS CAN/CSA-B66-00
BROOKLIN, ON REINFORCEMENT: STEEL TO CSA CAN DATE:
TOTAL CAPACITY: 25,853 LITRES TO UNDERSIDE OF CHAMBER LID
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018
5055
[199"]

108
4" INLET

[4 1/4"]
610
[24"]
4" INLET CAST-A-SEAL 402
175mmØ OPENING
CAST-A-SEAL
FOR DRY HYDRANT
402
DIXON-dfh 9140-600

TANK 2
4" PVC PIPE

TANK 2
2406

2527
100mm VENT
[94 3/4"]

[99 1/2"]
[88"]
2235
NOTE 1

108
1352 2351 1352

[4 1/4"]
[53 1/4"] [92 1/2"] [53 1/4"]
5055
1352
127 [199"] CAS 603 FOR

[5"]
128
[53 1/4"] 8" I.D. SDR 35

410
[5"]

[16 1/8"]
SECTION A
SCALE:1/60
CAS 603 FOR
175mmØ OPENING
8" I.D. SDR 35
FOR DRY HYDRANT
100mm VENT
12" X 24" TUFF-TITE DIXON-dfh 9140-600
WITH COVER 2
100mm VENT REQ. PER UNIT
TANK 1

2591
[102"]
12" X 24" TUFF-TITE
WITH COVER 2
REQ. PER UNIT 100mm VENT

40
4" INLET
CAST-A-SEAL 402
TANK 1 TANK 2

[5"]
128
2527
TOP VIEW 127

[99 1/2"]
SCALE:1/60 [5"]
86
[3 3/8"]
108
[4 1/4"]

GENERAL NOTES:

1. CAS 603- CAST CLOSE AS POSSIBLE TO THE BOTTOM OF TANK


2591 CAS 603 FOR 2591
2. UNITS ARE SEALED WITH BUTYL TAPE AT THE JOINTS 8" I.D. SDR 35
[102"] [102"]
3. DELIVERY IS MADE BY CRANE-EQUIPPED TRUCKS

4. EXCAVATION MUST BE READY, SAFE AND ACCESSIBLE FOR UNLOADING FROM THE REAR OF THE TRUCK.

5. MIN OVERHEAD CLEARANCE OF 18FT IS REQUIRED SECTION B


SCALE:1/60
6. ALL UNITS MUST BE HANDLED WITH PROPER LIFTING EQUIPMENT (I.E. SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE IN FIRM SOIL AWAY FROM ANY VEHICULAR TRAFFIC

*2-NESTED FIRE WATER TANKS*


CONCRETE: 35MPa/5000PSI WEIGHT: 34,870lbs / 15,820kg DRAWN BY:
AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 22750 LITRES
5000 IMPERIAL GALLON
MANUFACTURED: MEETS CAN/CSA-B66-00
DATE: TOTAL CAPACITY: 25,853 LITRES TO UNDERSIDE OF CHAMBER LID
BROOKLIN, ON REINFORCEMENT: STEEL TO CSA CAN
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018 PER TANK
5055
[199"]

GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL


TAPE AT THE JOINTS
175mmØ OPENING
FOR DRY HYDRANT 2. DELIVERY IS MADE BY
DIXON-dfh 9140-600 CRANE-EQUIPPED TRUCKS

3. EXCAVATION MUST BE READY,


SAFE AND ACCESSIBLE FOR
UNLOADING FROM THE REAR OF

2591
[102"]
THE TRUCK.

4. MIN OVERHEAD CLEARANCE OF


18FT IS REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


100mm VENT
PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE


IN FIRM SOIL AWAY FROM ANY
VEHICULAR TRAFFIC
TUFF TITE 24" COVER
WITH 12"X24" RISER TOP VIEW
2 REQUIRED (TYP.)
SCALE:1/50
DRY HYDRANT
100mm VENT DIXON-dfh 9140-600

TUFF TITE 24" COVER

41
4" INLET
WITH 12"X24" RISER

610
[24"]

108
CAST-A-SEAL 402

[4 1/4"]
2 REQUIRED (TYP.)

4" PVC PIPE


4" INLET
CAST-A-SEAL 402

3067

127

3188
3188

[120 3/4"]

[125 1/2"]
[125 1/2"]

[5"]

2896
[114"]
86
[3 3/8"]

108
108

[4 1/4"]
[4 1/4"]

SECTION A SECTION B
SCALE:1/50 SCALE:1/50
*SINGLE FIRE WATER TANK*
CONCRETE: 35MPa/5000PSI WEIGHT: 40,905lbs / 18,555kg DRAWN BY:
AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 30000 LITRES
6600 IMPERIAL GALLON
MANUFACTURED: MEETS CAN/CSA-B66-00
BROOKLIN, ON DATE:
REINFORCEMENT: STEEL TO CSA CAN TOTAL CAPACITY: 33,918 LITRES TO UNDERSIDE OF CHAMBER LID
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018
5055
[199"]

108
4" PVC

[4 1/4"]
610
[24"]
4" INLET INLET
CAST-A-SEAL 175mmØ OPENING
402 FOR DRY HYDRANT
DIXON-dfh 9140-600

TANK 2
4" PVC PIPE
TANK 2

100mm VENT

3188
3188

2896

[125 1/2"]
[125 1/2"]

[114"]
1352 2351 1352 NOTE 1
[53 1/4"] [92 1/2"] [53 1/4"]
5055

108
[4 1/4"]
127 [199"]

[5"]
128
[5"]

1352
CAS 603 FOR

410
[53 1/4"] 8" I.D. SDR 35

[16 1/8"]
CAS 603 FOR
8" I.D. SDR 35 SECTION A
SCALE:1/60

2591
TANK 1 100mm VENT

[102"]
DRY HYDRANT
DIXON-dfh 9140-600
100mm VENT 12" X 24" TUFF-TITE
12" X 24" TUFF-TITE WITH COVER
WITH COVER
2 REQ. PER UNIT 2 REQ. PER UNIT

42
[5"]
128
4" INLET
TOP VIEW CAST-A-SEAL
SCALE:1/60 402

GENERAL NOTES: TANK 1 TANK 2

3188
1. CAS 603- CAST CLOSE AS POSSIBLE TO THE BOTTOM OF TANK
127
[125 1/2"]
2. UNITS ARE SEALED WITH BUTYL TAPE AT THE JOINTS [5"]

3. DELIVERY IS MADE BY CRANE-EQUIPPED TRUCKS CAS 603 FOR


87 8" I.D. SDR 35
4. EXCAVATION MUST BE READY, SAFE AND ACCESSIBLE FOR UNLOADING
108

FROM THE REAR OF THE TRUCK. [3 3/8"]


[4 1/4"]

5. MIN OVERHEAD CLEARANCE OF 18FT IS REQUIRED

6. ALL UNITS MUST BE HANDLED WITH PROPER LIFTING EQUIPMENT (I.E. 2591
SPREADER BAR)
[102"] SECTION B
6. MAXIMUM BURIAL DEPTH = 1 METRE IN FIRM SOIL AWAY FROM ANY SCALE:1/60
VEHICULAR TRAFFIC
*2-NESTED FIRE WATER TANKS*
CONCRETE: 35MPa/5000PSI WEIGHT: 40,905lbs / 18,555kg DRAWN BY:
AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND 30000 LITRES
6600 IMPERIAL GALLON
MANUFACTURED: MEETS CAN/CSA-B66-00
DATE: TOTAL CAPACITY: 33,918 LITRES TO UNDERSIDE OF CHAMBER LID
BROOKLIN, ON REINFORCEMENT: STEEL TO CSA CAN
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018
PER TANK
7315
203 [288"] 203
[8"] [8"]

175mmØ OPENING
FOR DRY HYDRANT
DIXON-dfh 9140-600
GENERAL NOTES:

1. CONCRETE TO BE 45MPa/6,500 P.S.I.

2642

3048
[120"]
[104"]
2. MAXIMUM BURIAL DEPTH = 1 METRE IN
FIRM SOIL AWAY FROM ANY VEHICULAR
100mm VENT TRAFFIC

TUFF TITE 24" COVER

[8"]
203
WITH 12"X24" RISER 2
REQUIRED (TYP.)

TOP VIEW
SCALE:1/60
DRY HYDRANT 100mm VENT
DIXON-dfh 9140-600

43
4" INLET
CAST-A-SEAL 402 7315 3048
[288"] [120"]
610
[24"]
[60"]
1524

4" PVC PIPE


2799

2997
2997

[118"]
[118"]

[110 1/4"]

2616
[103"]
[58"]
1473

SECTION A SECTION B

170
[6 3/4"]
SCALE:1/60 SCALE:1/60

*SINGLE FIRE WATER TANK*


CONCRETE: 45MPa / 6,500PSI CSA APPROVED DRAWN BY:
AIR ENTRAINMENT: 6-8% WEIGHT: 47,000lbs / 21,000kg (TOP) S.RIMLAND 45500 LITRES
47,000lbs / 21,000kg (BOTTOM) 10000 IMPERIAL GALLON
MANUFACTURED: MEETS CAN/CSA-B66-00
OTTAWA, ON REINFORCEMENT: MEETS G30.14-M1983 DATE:
1-800-655-3430 JAN/2018 10,000 IMPERIAL GALLON / 45,500 LITRES
7315
[288"]
203 7315
[8"] [288"]
4" INLET 12" X 24" TUFF-TITE
CAST-A-SEAL 402 WITH COVER
2 REQ. PER TANK
610
[24"]

4" INLET
175mmØ OPENING
CAST-A-SEAL 402
FOR DRY HYDRANT
DIXON-dfh 9140-600
TANK 1
TANK 1
2799

2997
100mm VENT

[118"]
[110 1/4"]

2616
[103"]
NOTE 1

410
[16 1/8"]
170
[6 3/4"]
1352 4611 1352
[53 1/4"] [181 1/2"] [53 1/4"]
1352
CAS 603 FOR
[53 1/4"] 8" I.D. SDR 35
SECTION A
CAS 603 FOR SCALE:1/80
8" I.D. SDR 35

3048
TANK 2

[120"]
12" X 24" TUFF-TITE 100mm VENT DRY HYDRANT
WITH COVER DIXON-dfh 9140-600

[8"]
203
100mm VENT 3048
2 REQ. PER TANK
[120"]

44
TOP VIEW
SCALE:1/80
4" PVC PIPE
[60"]
1524

2997 TANK 1 TANK 2


[118"]

GENERAL NOTES:

1. CAS 603 - CAST CLOSE AS POSSIBLE TO


[58"]
1473
170
[6 5/8"]

THE BOTTOM OF TANK

2. CONCRETE TO BE 45MPa/6,500 P.S.I.


CAS 603 FOR
3048 8" I.D. SDR 35
3. MAXIMUM BURIAL DEPTH = 1 METRE IN
FIRM SOIL AWAY FROM ANY VEHICULAR [120"]
TRAFFIC
SECTION B
SCALE:1/80

*2-NESTED FIRE WATER TANKS*


CONCRETE: 45MPa / 6,500PSI CSA APPROVED DRAWN BY:
AIR ENTRAINMENT: 6-8% WEIGHT: 47,000lbs / 21,000kg (TOP) S.RIMLAND 45500 LITRES
47,000lbs / 21,000kg (BOTTOM) 10000 IMPERIAL GALLON
MANUFACTURED: MEETS CAN/CSA-B66-00
OTTAWA, ON REINFORCEMENT: MEETS G30.14-M1983 PER TANK DATE:
1-800-655-3430 JAN/2018 10,000 IMPERIAL GALLON / 45,500 LITRES
9145 3660
[360"] [144 1/8"]
203 203 2745 203
[8"] [8"] [108 1/8"] [8"]

12"x 4" OPENING


(TYP.)
838 175mmØ OPENING

206

[71"]
[33"] FOR DRY HYDRANT

1804
TUFF- TITE 12" X 24" DIXON-dfh 9140-600

[8 1/8"](TYP.)
WITH COVER 6"X20"
3 REQUIRED OPENING. 2
REQUIRED

3660
152

[144 1/8"]
[6"](TYP.)
2'x2' OPENING
[71"] (TYP.)
100mm VENT 1803 203
[8"](TYP.)

TOP VIEW SECTION B


203

SCALE:1/60 SCALE:1/60
[8"](TYP.)

45
9145
[360"]
TUFF- TITE 12" X 24"
4" PVC
WITH COVER
610
[24"]

INLET
3 REQUIRED

91,000 LITRES TO ROOF


20,000 IMPERIAL GALLONS 4" PVC PIPE

GENERAL NOTES:
3391

1. CONCRETE TO BE 45MPa/6,500 P.S.I.

3607
[142"]
[133 1/2"]

77

3230
[3"] 2. REINFORCEMENT TO CONFORM TO

[127 1/8"]
CSA-G30.12-400Pa

3. BURIAL DEPTH: 30"

KNOCKOUT 4. REINFORCEMENT
PANEL
610
[24"]

TANK: 20M @ 150 O/C BOTH WAYS


LID: 20M @ 150 O/C BOTH WAYS

SECTION A
SCALE:1/60 *SINGLE FIRE WATER TANK*
CONCRETE: 45MPa / 6,500PSI CPA CERTIFIED DRAWN BY:
AIR ENTRAINMENT: 6-8% WEIGHT: 77,100lbs/34,970kg (TOP) S.RIMLAND 90900 LITRES
20000 IMPERIAL GALLON
MANUFACTURED: MEETS CAN/CSA-B66-00 77,700lbs/35,244kg (BOTTOM)
OTTAWA, ON REINFORCEMENT : STEEL TO CSA CAN DATE:
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018 20,000 IMPERIAL GALLON / 91,000 LITRES
9145 9145
[360"] [360"]
203 203 2745 203
[8"] [8"] [108 1/8"] [8"]
610
[24"]

175mmØ OPENING
FOR DRY HYDRANT
4" PVC DIXON-dfh 9140-600
INLET
TANK 1
KNOCKOUT
TANK 1 PANEL
3391

3607
[142"]
77
[133 1/2"]

3230
[3"]

[127 1/8"]
838 NOTE 1

410
[33"] 100mm VENT

[16 1/8"]
610
1352 6440 1352
1352 [24"] CAS 603 FOR
[53 1/4"] 8" I.D. SDR 35
[53 1/4"] [253 1/2"] [53 1/4"] SECTION A
SCALE:1/90

CAS 603 FOR


8" I.D. SDR 35

TANK 2

3660
[144 1/8"]
3660
12" X 24" TUFF-TITE [144 1/8"]
100mm VENT 100mm VENT
WITH COVER 175mmØ OPENING

[8"]
203

46
3 REQ. PER TANK FOR DRY HYDRANT
DIXON-dfh 9140-600

TOP VIEW
12"x 4" OPENING
SCALE:1/90 4" PVC PIPE (TYP.)

TANK 1 TANK 2
GENERAL NOTES:
3607
[142"]

6"X20"
1. CAS 603 - CAST CLOSE AS POSSIBLE TO THE BOTTOM OF THE TANK 2'x2' OPENING OPENING. 2
(TYP.) REQUIRED
2. CONCRETE TO BE 45MPa/6,500 P.S.I.

3. REINFORCEMENT TO CONFORM TO CSA-G30.12-400Pa

4. BURIAL DEPTH: 30" CAS 603 FOR


8" I.D. SDR 35

5. REINFORCEMENT
SECTION B
TANK: 20M @ 150 O/C BOTH WAYS SCALE:1/90
LID: 20M @ 150 O/C BOTH WAYS

*2-NESTED FIRE WATER TANKS*


CONCRETE: 45MPa / 6,500PSI CPA CERTIFIED DRAWN BY:
AIR ENTRAINMENT: 6-8% WEIGHT: 81,065lbs/36,770kg (TOP) S.RIMLAND 90900 LITRES
20000 IMPERIAL GALLON
MANUFACTURED: MEETS CAN/CSA-B66-00 81,625lbs/37,025kg (BOTTOM)
OTTAWA, ON REINFORCEMENT : STEEL TO CSA CAN DATE:
PER TANK
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018 20,000 IMPERIAL GALLON / 91,000 LITRES
2972
[117"]
711 495 203 203 495 711
[28"] [19 1/2"] [8"] [8"] [19 1/2"] [28"]

GENERAL NOTES:

254
[10"]
1. UNITS ARE SEALED WITH BUTYL TAPE AT
THE JOINTS

508
[20"]
429
2. DELIVERY IS MADE BY CRANE-EQUIPPED
[16 7/8"]
TRUCKS

3. EXCAVATION MUST BE READY, SAFE AND


ACCESSIBLE FOR UNLOADING FROM THE
REAR OF THE TRUCK.

214
6" OPENING
FOR VENT 4. MIN OVERHEAD CLEARANCE OF 18FT IS
2 REQ. REQUIRED
SEE DETAIL 1

[86"]
2184
537
108
TOILET RISER 5. ALL UNITS MUST BE HANDLED WITH

[21 1/8"]
OPENING PROPER LIFTING EQUIPMENT (I.E.
2 REQ. SPREADER BAR)

214
6. MAXIMUM BURIAL DEPTH = 1 METRE IN

[8 7/16"] [4 1/4"] [8 7/16"]


R2
[R 14 FIRM SOIL AWAY FROM ANY VEHICULAR
8 TRAFFIC
7/
16
"]
DETAIL 1: TOILET RISER
OPENING
SCALE:1/16

47
TOP VIEW
SCALE:1/30

2870 2082
[113"] [82"]

76
[3"]

[51"]
1295
648
[25 1/2"]

76
76

[3"]
[3"]

76 76
[3"] (TYP.) SECTION A [3"] SECTION B
SCALE:1/30 SCALE:1/30

CONCRETE: 35MPa at 28 days / 5000PSI UNIT WEIGHT: 11,620 lbs DRAWN BY:
AIR ENTRAINMENT: 6-8% CPA CERTIFIED S.RIMLAND PRIVY 1000 LOW WOOD
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN
BROOKLIN, ON DATE:
A23.1 /A23.3 G30.18 Fy=400MPa
FEB/2018 1000 IMPERIAL GALLON / 4,500 LITRES
1-800-655-3430
5055
[199"]
572 1182
[22 1/2"] SEE DETAIL 1 [46 1/2"]
305 TOILET RISER OPENING 864 GENERAL NOTES:
2 REQ.
[12"] [34"]
1. UNITS ARE SEALED WITH BUTYL
TAPE AT THE JOINTS

305
305

[12"]
[12"]

521
521
2. DELIVERY IS MADE BY

[20 1/2"]
[20 1/2"]
CRANE-EQUIPPED TRUCKS

3. EXCAVATION MUST BE READY,


SAFE AND ACCESSIBLE FOR
TUFF TITE 12" COVER 429 UNLOADING FROM THE REAR OF
4" PVC COUPLER 4" PVC COUPLER
TO CONNECT TO CONNECT WITH 12"X12" RISER [16 7/8"] THE TRUCK.
4" PIPE 4" PIPE
4. MIN OVERHEAD CLEARANCE OF

2591
[102"]
18FT IS REQUIRED

214
5. ALL UNITS MUST BE HANDLED WITH

[8 7/16"]
PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

537
108
6. MAXIMUM BURIAL DEPTH = 1 METRE

[4 1/4"]

[21 1/8"]
IN FIRM SOIL AWAY FROM ANY
VEHICULAR TRAFFIC

214
[8 7/16"]
R2
[R 14
8
7/
16
TOP VIEW "]

SCALE:1/50 DETAIL 1: TOILET RISER


OPENING
SCALE:1/16

48
TUFF TITE 12" COVER TUFF TITE 12" COVER
WITH 12"X12" RISER WITH 12"X12" RISER

[5"]
127
127
[5"]

[59"]
[59"]

1499
1499

87

108
108

[4 1/4"]
[4 1/4"]

[3 3/8"]

5055 2591
[199"] [102"]

SECTION A SECTION B
SCALE:1/50 SCALE:1/50

CONCRETE: 35MPa/5000PSI WEIGHT: 27,180lbs / 12,330kg DRAWN BY:


AIR ENTRAINMENT: 6-8% S.RIMLAND
CPA CERTIFIED PRIVY 2500 WOOD
MANUFACTURED: MEETS CAN/CSA-B66-00
BROOKLIN, ON REINFORCEMENT: STEEL TO CSA CAN DATE:
2,500 IMPERIAL GALLON / 11,365 LITRES
1-800-655-3430 A23.1 /A23.3 G30.18 Fy=400MPa JAN/2018
4876
[192"]

2-20mmØ ST. STEEL 4190 2591


CAST IN PLACE BARS
EQUALLY SPACED [165"] [102"] 2-20mmØ ST. STEEL
IN OPENING CAST IN PLACE BARS
SEE DETAIL 1 EQUALLY SPACED
550 1274 542 1274 550 686 IN OPENING
12" x 16" TUFF-TITE SEE DETAIL 2
[21 5/8"] [50 1/8"] [21 3/8"] [50 1/8"] [21 5/8"] [27"] RISER WITH COVER

WOOD
[6"]
152
STRUCTURE

407
[16"]

529
529

[20 7/8"]
[20 7/8"]
50

1339
[52 3/4"]
356mmØ OPENING 356mmØ OPENING 400
[2"] FOR VENT FOR VENT
2 REQUIRED 2 REQUIRED [15 3/4"]
372mmØ HOLE IN 372mmØ HOLE IN
CONC. SLAB TOP CONC. SLAB TOP
[59"]
1499

2591
FOR TOILET FOR TOILET

[102"]
2 REQUIRED 2 REQUIRED

2095 12" x 16" TUFF-TITE


RISER WITH COVER
[82 1/2"]

WOOD

1250
[49 1/4"]
STRUCTURE

[4"]
102
[6"]

102
152

[4"] SECTION B
SCALE:1/50
102
[4"] 372
[14 5/8"]
TOP VIEW
372mmØ HOLE IN NOTCH TOILET
SCALE:1/50 CONC. SLAB TOP RISER TO
FOR TOILET ACCOMMODATE

49
2 REQUIRED 2-STAINLESS
124 124 124 STEEL BARS
124

[4 7/8"] [4 7/8"] [4 7/8"]

4876
124

[192"]
50
124

[2"] 2-20mmØ ST. STEEL 2-20mmØ ST. STEEL


[4 7/8"] [4 7/8"] [4 7/8"]

550 1274 542 1274 550 686 CAST IN PLACE BARS CAST IN PLACE BARS
EQUALLY SPACED EQUALLY SPACED
[21 5/8"] [50 1/8"] [21 3/8"] [50 1/8"] [21 5/8"] [27"] 12" x 16" TUFF-TITE
ON CENTER ON CENTER
IN OPENING IN OPENING
RISER WITH COVER
WOOD
451
STRUCTURE
[17 3/4"]
[6"]
152

DETAIL 1: TOILET UNIT PLAN DETAIL 2: TOILET UNIT SECTION


SCALE: 1/16 SCALE: 1/16
GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL TAPE AT THE JOINTS

[71"]
1803
2. EXCAVATION MUST BE READY, SAFE AND ACCESSIBLE FOR UNLOADING FROM THE REAR
OF THE TRUCK.

3. MIN OVERHEAD CLEARANCE OF 18FT IS REQUIRED

4. ALL UNITS MUST BE HANDLED WITH PROPER LIFTING EQUIPMENT (I.E. SPREADER BAR)

5. SCHEMATIC ONLY (FURTHER DETAIL UPON REQUEST)


102
[4"] SECTION A 6. MAXIMUM BURIAL DEPTH=30"
SCALE:1/50
*CONCRETE BUILDING OPTIONS AVAILABLE*
CONCRETE: 35MPa/5000PSI WEIGHT: DRAWN BY:
AIR ENTRAINMENT: 6-8% TOP: 16,000lbs/7,250kg S.RIMLAND PRIVY 3000 WOOD
BOTTOM: 16,000lbs/7,250kg
MANUFACTURED: MEETS CAN/CSA-B66-00
CSA APPROVED DATE:
OTTAWA, ON REINFORCEMENT: MEETS G30.14-M1983
3,000 IMPERIAL GALLON / 13,650 LITRES
1-800-655-3430 JAN/2018
4876
2591
[192"]
[102"] 2-19mmØ ST. STEEL
CAST IN PLACE BARS
2-19mmØ ST. STEEL 4190 EQUALLY SPACED
CAST IN PLACE BARS IN OPENING
EQUALLY SPACED [165"] 12" x 16" TUFF-TITE SEE DETAIL 2
IN OPENING RISER WITH COVER
SEE DETAIL 1
550 1274 542 1274 550 686

[6"]
152
[21 5/8"] [50 1/8"] [21 3/8"] [50 1/8"] [21 5/8"] [27"]

407
[16"]

529
529

[20 7/8"]
[20 7/8"]
50

1339
[52 3/4"]
310mmØ OPENING 310mmØ OPENING 400
[2"] FOR VENT FOR VENT
2 REQUIRED 2 REQUIRED [15 3/4"]
372mmØ HOLE IN 372mmØ HOLE IN
1876

CONC. SLAB TOP CONC. SLAB TOP


[73 7/8"]

2591
FOR TOILET FOR TOILET

[102"]
2 REQUIRED 2 REQUIRED

2095 12" x 16" TUFF-TITE


RISER WITH COVER
[82 1/2"]
WOOD

1250
STRUCTURE

[49 1/4"]

[4"]
102
102
[4"]
[6"]
152

SECTION B
102
SCALE:1/50
[4"] 372
[14 5/8"]
TOP VIEW
372mmØ HOLE IN NOTCH TOILET
SCALE:1/50 CONC. SLAB TOP RISER TO
FOR TOILET ACCOMMODATE
2 REQUIRED 2-STAINLESS
124 124 124 STEEL BARS
4876 PROVIDED BY

124
[4 7/8"] [4 7/8"] [4 7/8"] ONTARIO PARKS
[192"]
124
550 1274 542 1274 550 686

50
[21 5/8"] [50 1/8"] [21 3/8"] [50 1/8"] [21 5/8"] [27"] 50
12" x 16" TUFF-TITE
124

RISER WITH COVER [2"] 2-19mmØ ST. STEEL 2-19mmØ ST. STEEL
[4 7/8"] [4 7/8"] [4 7/8"]

CAST IN PLACE BARS CAST IN PLACE BARS


WOOD
EQUALLY SPACED EQUALLY SPACED

[6"]
STRUCTURE

152
ON CENTER ON CENTER
IN OPENING IN OPENING
451
[17 3/4"]

DETAIL 1: TOILET UNIT PLAN DETAIL 2: TOILET UNIT SECTION


SCALE: 1/16 SCALE: 1/16

GENERAL NOTES:

2180
[85 7/8"]
1. UNITS ARE SEALED WITH BUTYL TAPE AT THE JOINTS

2. EXCAVATION MUST BE READY, SAFE AND ACCESSIBLE FOR UNLOADING FROM THE REAR
OF THE TRUCK.

3. MIN OVERHEAD CLEARANCE OF 18FT IS REQUIRED

4. ALL UNITS MUST BE HANDLED WITH PROPER LIFTING EQUIPMENT (I.E. SPREADER BAR)

102 5. SCHEMATIC ONLY (FURTHER DETAIL UPON REQUEST)


[4"] SECTION A
SCALE:1/50 6. MAXIMUM BURIAL DEPTH=30"

*CONCRETE BUILDING OPTIONS AVAILABLE*


CONCRETE: 35MPa/5000PSI WEIGHT: DRAWN BY:
AIR ENTRAINMENT: 6-8% TOP: 19,365lbs/8,784kg S.RIMLAND PRIVY 4000 WOOD
BOTTOM: 19,365lbs/8,784kg
MANUFACTURED: MEETS CAN/CSA-B66-00
OTTAWA, ON CSA APPROVED DATE:
REINFORCEMENT: MEETS G30.14-M1983 4,000 IMPERIAL GALLON / 19,000 LITRES SEPTIC
1-800-655-3430 JAN/2018
4876
[192"]
2591
2-19mmØ ST. STEEL 4190 [102"]
CAST IN PLACE BARS 2-19mmØ ST. STEEL
EQUALLY SPACED [165"] CAST IN PLACE BARS
IN OPENING EQUALLY SPACED
SEE DETAIL 1 12" x 16" TUFF-TITE IN OPENING
550 1274 542 1274 550 686
RISER WITH COVER SEE DETAIL 2
[21 5/8"] [50 1/8"] [21 3/8"] [50 1/8"] [21 5/8"] [27"]
[6"]
152

407
[16"]

529
529

[20 7/8"]
[20 7/8"]
50

1339
[52 3/4"]
310mmØ OPENING 310mmØ OPENING 400
[2"] FOR VENT FOR VENT
2 REQUIRED 2 REQUIRED [15 3/4"]
372mmØ HOLE IN 372mmØ HOLE IN
CONC. SLAB TOP CONC. SLAB TOP
[89"]
2261

2591
FOR TOILET FOR TOILET

[102"]
2 REQUIRED 2 REQUIRED

2095 12" x 16" TUFF-TITE


RISER WITH COVER
[82 1/2"]
WOOD

1250
STRUCTURE

[49 1/4"]

[4"]
102
102
[6"]
152

[4"] SECTION B
102
SCALE:1/60
[4"] 372
[14 5/8"]
TOP VIEW
372mmØ HOLE IN NOTCH TOILET
CONC. SLAB TOP RISER TO

51
SCALE:1/50
FOR TOILET ACCOMMODATE
2 REQUIRED 2-STAINLESS
124 124 124 STEEL BARS
PROVIDED BY
124

[4 7/8"] [4 7/8"] [4 7/8"] ONTARIO PARKS


4876
[192"]
124

550 1274 542 1274 550 686 50


124

[21 5/8"] [50 1/8"] [21 3/8"] [50 1/8"] [21 5/8"] [27"] 12" x 16" TUFF-TITE [2"] 2-19mmØ ST. STEEL 2-19mmØ ST. STEEL
[4 7/8"] [4 7/8"] [4 7/8"]

RISER WITH COVER CAST IN PLACE BARS CAST IN PLACE BARS


EQUALLY SPACED EQUALLY SPACED
ON CENTER ON CENTER
WOOD IN OPENING IN OPENING

[6"]
152
STRUCTURE 451
[17 3/4"]

DETAIL 1: TOILET UNIT PLAN DETAIL 2: TOILET UNIT SECTION


SCALE: 1/16 SCALE: 1/16
GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL TAPE AT THE JOINTS

2565
[101"]
2. EXCAVATION MUST BE READY, SAFE AND ACCESSIBLE FOR UNLOADING FROM THE REAR
OF THE TRUCK.

3. MIN OVERHEAD CLEARANCE OF 18FT IS REQUIRED

4. ALL UNITS MUST BE HANDLED WITH PROPER LIFTING EQUIPMENT (I.E. SPREADER BAR)

5. SCHEMATIC ONLY (FURTHER DETAIL UPON REQUEST)


102 SECTION A
6. MAXIMUM BURIAL DEPTH=30"
[4"] SCALE:1/60
*CONCRETE BUILDING OPTIONS AVAILABLE*
CONCRETE: 35MPa/5000PSI WEIGHT: DRAWN BY:
AIR ENTRAINMENT: 6-8% TOP: 20,000lbs/9,070kg S.RIMLAND
BOTTOM: 20,000lbs/9,070kg
MANUFACTURED: MEETS CAN/CSA-B66-00
PRIVY 5000 WOOD
CSA APPROVED DATE:
OTTAWA, ON REINFORCEMENT: MEETS G30.14-M1983
5,000 IMPERIAL GALLON / 22,730 LITRES SEPTIC
1-800-655-3430 JAN/2018
2286
[90"]
GENERAL NOTES:
3" DIAMETER
PVC PIPING 1. UNITS ARE SEALED WITH BUTYL TAPE AT
FOR VENT THE JOINTS

2. DELIVERY IS MADE BY CRANE-EQUIPPED


TRUCKS

3. EXCAVATION MUST BE READY, SAFE AND


ACCESSIBLE FOR UNLOADING FROM THE
REAR OF THE TRUCK.

4. MIN OVERHEAD CLEARANCE OF 18FT IS

[60"]
1524
REQUIRED

5. ALL UNITS MUST BE HANDLED WITH


PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE IN


FIRM SOIL AWAY FROM ANY VEHICULAR
TRAFFIC

24" x 6" TUF-TITE


RISER WITH COVER TOP VIEW
3 REQUIRED
SCALE:1/30

4" INLET PIPE 3" PVC 3" DIAMETER 24" x 6" TUF-TITE 3" DIAMETER

52
CAST-A-SEAL 402 VENT VENT 4 RISER WITH COVER PVC PIPING
REQUIRED 3 REQUIRED FOR VENT

[4"]
102
PIPE 4" PVC

4" OUTLET
CAST-A-SEAL 402 PIPE 4" PVC

[66"]
[66"]

1676
1676

[54"]
1371
[52"]
1321

200
DIAM. [4"]

[7 7/8"]
3 REQUIRED (TYP)

356
[14"]

76
432

[3"]
[17"]

OPENING 8" x 4"

76 76
[3"](TYP.) [3"](TYP.)
178

SECTION A SECTION B
[7"](TYP.)

SCALE:1/30 SCALE:1/30

CONCRETE: 35MPa / 5,000PSI UNIT WEIGHT: DRAWN BY: OIL


AIR ENTRAINMENT: 6-8% 10,230 lbs / 4,650 KG S.RIMLAND MODEL 65
MANUFACTURED: REINFORCEMENT : STEEL TO CSA CAN CPA CERTIFIED
INTERCEPTOR
BROOKLIN, ON A23.1 / A23.3. G30.18 Fy=400MPa MEETS CSA-BB6-00
DATE: 650 IMPERIAL GALLON / 3,000 LITRES
1-800-655-3430 JAN/2018 OPTIMUM FLOW RATE: 36 L/MINUTE
2540
[100"]
3" DIAMETER
VENT
GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL TAPE AT


THE JOINTS

2. DELIVERY IS MADE BY CRANE-EQUIPPED


TRUCKS

3. EXCAVATION MUST BE READY, SAFE AND


ACCESSIBLE FOR UNLOADING FROM THE
REAR OF THE TRUCK.

4. MIN OVERHEAD CLEARANCE OF 18FT IS

1834
REQUIRED

[72 1/4"]
5. ALL UNITS MUST BE HANDLED WITH
PROPER LIFTING EQUIPMENT (I.E.
SPREADER BAR)

10M LIFTING 6. MAXIMUM BURIAL DEPTH = 1 METRE IN


ANCHOR. FIRM SOIL AWAY FROM ANY VEHICULAR
4 REQUIRED (TYP) TRAFFIC

24" x 6" TUF-TITE


RISER WITH COVER TOP VIEW
3 REQUIRED SCALE:1/30

4" INLET 3" DIAMETER 24" x 6" TUF-TITE 24" x 6" TUF-TITE
CAST-A-SEAL 402 VENT RISER WITH COVER RISER WITH COVER
4 REQUIRED 3 REQUIRED 3 REQUIRED
[4"]
102

SANITARY TY

53
4" OUTLET
CAST-A-SEAL 402

PIPE 4" PVC

1664
1664

[65 1/2"]
[65 1/2"]

1359
1309

[53 1/2"]
[51 1/2"]
DIAM. [4"]
3 REQUIRED (TYP)

200
[7 7/8"]

[5"]

76
127

457
[18"]
533
[21"]

[3"](TYP.)
OPENING 30" x 5"
[8"]
203

76 76
SECTION A [3"](TYP.) SECTION B [3"](TYP.)
SCALE:1/30 SCALE:1/30
CONCRETE: 35MPa / 5,000PSI UNIT WEIGHT: DRAWN BY:
AIR ENTRAINMENT: 6-8% 11,390 lbs / 5,170 KG S.RIMLAND
OIL
MANUFACTURED: REINFORCEMENT : STEEL TO CSA CAN CPA CERTIFIED
MODEL 100 INTERCEPTOR
BROOKLIN, ON A23.1 / A23.3. G30.18 Fy=400MPa MEETS CSA-BB6-00 DATE: 960 IMPERIAL GALLON / 4,400 LITRES
1-800-655-3430 JAN/2018
OPTIMUM FLOW RATE: 53 L/MINUTE
3213
[126 1/2"]
3" PVC PIPING GENERAL NOTES:
FOR VENT
1. UNITS ARE SEALED WITH BUTYL TAPE AT
THE JOINTS

2. DELIVERY IS MADE BY CRANE-EQUIPPED


COUPLINGS TRUCKS

3. EXCAVATION MUST BE READY, SAFE AND


ACCESSIBLE FOR UNLOADING FROM THE
REAR OF THE TRUCK.

4. MIN OVERHEAD CLEARANCE OF 18FT IS


REQUIRED

5. ALL UNITS MUST BE HANDLED WITH

2553
PROPER LIFTING EQUIPMENT (I.E.

[100 1/2"]
SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE IN


FIRM SOIL AWAY FROM ANY VEHICULAR
TRAFFIC
10M LIFTING
ANCHOR.
4 REQUIRED (TYP)

24" x 6" TUF-TITE


RISER WITH COVER
3 REQUIRED
TOP VIEW
SCALE:1/40

54
4" INLET OPTIONAL INLET 24" x 6" TUF-TITE 3" PVC PIPING 24" x 6" TUF-TITE 3" PVC PIPING 10M LIFTING
CAST-A-SEAL 402 4" PVC POLYSEAL RISER WITH COVER FOR VENT RISER WITH COVER FOR VENT ANCHOR
3 REQUIRED 4 REQUIRED 3 REQUIRED 4 REQUIRED 4 REQUIRED (TYP)
140
[5 1/2"]

4" OUTLET
CAST-A-SEAL 402 PIPE 4" PVC

[63"]
[63"]

1601
1601

[53"]
1346
[51"]
1296
DIAM. [4"]
76

76
3 REQUIRED (TYP)

[5"]
127
[4"]
102

[3"](TYP.)
[3"] (TYP.)

457
[18"]
OPENING 30" x 5"

76 76
[3"](TYP.) [3"](TYP.)

SECTION A SECTION B
SCALE:1/40 SCALE:1/40

CONCRETE: 35MPa / 5,000PSI UNIT WEIGHT: DRAWN BY: OIL


AIR ENTRAINMENT: 6-8% 15,485 lbs / 7,025 KG S.RIMLAND MODEL 155 INTERCEPTOR
MANUFACTURED: REINFORCEMENT : STEEL TO CSA CAN CPA CERTIFIED
BROOKLIN, ON DATE: 1,550 IMPERIAL GALLON / 7,000 LITRES
A23.1 / A23.3. G30.18 Fy=400MPa MEETS CSA-BB6-00
1-800-655-3430 JAN/2018 OPTIMUM FLOW RATE: 86 L/MINUTE
5055
[199"] GENERAL NOTES:

1. UNITS ARE SEALED WITH BUTYL TAPE AT THE JOINTS

2. DELIVERY IS MADE BY CRANE-EQUIPPED TRUCKS

3. EXCAVATION MUST BE READY, SAFE AND


ACCESSIBLE FOR UNLOADING FROM THE REAR OF
THE TRUCK.

4. MIN OVERHEAD CLEARANCE OF 18FT IS REQUIRED

5. ALL UNITS MUST BE HANDLED WITH PROPER LIFTING


EQUIPMENT (I.E. SPREADER BAR)

6. MAXIMUM BURIAL DEPTH = 1 METRE IN FIRM SOIL

2591
[102"]
AWAY FROM ANY VEHICULAR TRAFFIC

7. STOP VALVE BALL MUST BE KEPT FREE OF LOCK OR


SEAT POSITION DURING INSTALLATION.

8. ONCE THE TANK IS INSTALLED, PRIME WITH WATER


TO MAINTAIN A WATER LEVEL ABOVE STOP VALVE
SEAT POSITION AT ALL TIMES.

9. IF THE TANK IS PUMPED FROM TIME TO TIME, WATER


MUST BE ADDED TO KEEP THE STOP VALVE BALL
CHAMFERED EDGES
TUFF TITE 24" COVER 3" DIAMETER VENT. FLOATING.
AT BASE ON INTERIOR
WITH 12"X24" RISER 3 REQUIRED
3 REQUIRED (TYP.) 10.IF THE STOP VALVE SEATS ITSELF IN CLOSE
TOP VIEW POSITION, RELEASE BY PULLING THE ROPE
SCALE:1/50 ATTACHED TO THE BALL. THE ROPE CAN BE
REACHED FROM THE MANHOLE AT OUTLET END.

11. SPECIFIC OIL GRAVITY .88 TO .90 WHICH IS TOO LOW


TO FLOAT THE BALL AND THEREFORE PREVENTS OIL
FROM ESCAPING FROM THE OIL INTERCEPTOR.

55
100Ø T-PIPE
ASSEMBLY
3" DIAMETER VENT- 3 TUFF TITE 24" COVER
4" INLET REQUIRED.3 4" CLEARSTONE WITH 12"X24" RISER 4" INLET
CAST-A-SEAL 402 @300MM RADIUS AROUND 3 REQUIRED (TYP.) CAST-A-SEAL 402

[5"]
127
PIPE
POLYSEAL WITH 3" DIAMETER VENT.
FLANGE 3 REQUIRED

350
[13 3/4"]
4" OUTLET
DIAM 4" OPENING. CAST-A-SEAL 402
3 REQUIRED (TYP.) 127
[5"]
[59"]

[59"]
1499
1499

30" x 5" DIAM 4" OPENING.

1149
[44"]
1118

[45 1/4"]
380
OPENING AT 3 REQUIRED (TYP.)

[15"]
87

600
108
108

[4 1/4"]

457
BASE LEVEL

[18"]
[4 1/4"]

100Ø ENQUIP. OIL

[23 5/8"]
[3 3/8"]
STOP VALVE W/ OPENING 30" x 5"
P-TRAP ASSEMBLY. AT BASE LEVEL

170
[6 3/4"]
5055 2591
[199"] [102"]

SECTION A SECTION B
SCALE:1/50 SCALE:1/50

CONCRETE: 35MPa / 5,000PSI WEIGHT: DRAWN BY: OIL


17,895lbs / 8,120kg S.RIMLAND
AIR ENTRAINMENT: 6-8% MODEL 250
CPA CERTIFIED INTERCEPTOR
MANUFACTURED: REINFORCEMENT : STEEL TO CSA CAN
MEETS CSA-BB6-00 DATE:
BROOKLIN, ON A23.1 / A23.3. G30.18 Fy=400MPa
1-800-655-3430 JAN/2018 2,500 IMPERIAL GALLON / 11,365 LITRES
TOP VIEW TOP VIEW
SCALE:1/16 SCALE:1/16

56
610 914 305 610
[24"] [36"] [12"] [24"]
51

51
[2"]

[2"]
432
432

[17"]
[17"]

381

381
[15"]

[15"]
SECTION A SECTION B SECTION A SECTION B
SCALE:1/16 SCALE:1/16 SCALE:1/16 SCALE:1/16

LARGE DISTRIBUTION BOX SMALL DISTRIBUTION BOX


1 INLET - 15 OUTLET 1 INLET - 7 OUTLET

CONCRETE: 35MPa/5000PSI CPA CERTIFIED DRAWN BY:


AIR ENTRAINMENT: 6-8% MEETS CSA-BB6-00 S.RIMLAND DISTRIBUTION BOXES
MANUFACTURED: REINFORCEMENT: STEEL TO CSA CAN
BROOKLIN, ON A23.1 /A23.3 G30.18 Fy=400MPa DATE:
1-800-655-3430 JAN/2018
660
[26"] 660 RETROFIT 22"X26"
[26"]
406
[16"] I.D.

76
[3"]

559
[22"]
[6"]
154
CROSS SECTION
SCALE:1/16
16"DIA. X 6"
TOP VIEW TUF-TITE RISER
2 - 5 116" GALV. LIFTING
HOOK WITH COVER
SCALE:1/16

610
[24"] RETROFIT 20"X24"
610
[24"]

406
[16"]

508
[20"]
76
[3"]

[6"]
154
CROSS SECTION
SCALE:1/16

57
2 - 5 116" GALV. LIFTING TOP VIEW 16"DIA. X 6"
HOOK SCALE:1/16 TUF-TITE RISER
WITH COVER

813
[32"]
2 - 5 116" GALV. LIFTING
HOOK
RETROFIT 32"X32"

76
[3"]
813
[32"]
406

813
[32"]
[16"] I.D.
76
[3"]

[6"]
152
16"DIA. X 6"
TUF-TITE RISER
WITH COVER

TOP VIEW CROSS SECTION


SCALE:1/20 SCALE:1/16

CONCRETE: 35MPa / 4600PSI UNIT WEIGHT: DRAWN BY:


AIR ENTRAINMENT: 6-8% LID 22"X26": 132lbs / 60kgs S.RIMLAND RETROFIT LIDS
MANUFACTURED: REINFORCEMENT : STEEL TO CSA LID 20"X24": 110lbs / 50kgs
BROOKLIN, ON CAN A23.1 / A23.3. G30.18 LID 32"X32": 214lbs / 97kgs DATE:
1-800-655-3430 Fy=400MPa JAN/2018
Aluminum Tank Accessories Available on Request

Drip Proof
Access Doors

Standard Opening Sizes – 36 x 36


30 x 30
24 x 24
Custom size Openings and Heights Available on Special Order

Flush Mount
Access Doors

Standard Opening Sizes – 36 x 36


32 x 35
30 x 21
Custom size Openings on Special Order

Access Ladders

Non-Slip Aluminum Rungs on 12” Centers


Order to Required Height

58
BROOKLIN OFFICE NEWMARKET OFFICE HUNTSVILLE /HALIBURTON OFFICE
brooklinsales@brooklin.com newmarketsales@brooklin.com huntsvillesales@brooklin.com

T: 905-655-3311 1-800-655-3430 T: 905-895-2373 1-888-407-6443 T: 705-789-2338 1-800-264-3302


F: 905-655-3847 F: 905-898-3264 F: 705-789-9829

60
Warranty Policy

Brooklin Concrete Products warrants its product to be free of


defects in material and workmanship, insofar as such products
are of its own manufacture and are installed and used in
accordance with our recommendations and/or installation
guidelines.

This warranty shall be in effect for a period of one year from


the day of shipment. This limited warranty covers the repair or
replacement, as Brooklin Concrete Products may elect, of
defective products regarding which, upon discovery of the
defect, the purchaser has given immediate written notice.

This warranty does not apply to any product that has been
subjected to abuse or misuse, or to a product that has been
altered or modified by others in any way so as, in our judgment,
to affect its dependability. Brooklin Concrete Product’s liability
shall be limited to the repair or replacement of its product, the
cost of which shall not exceed the original purchase price of the
product.

61
COMPANY PRODUCT
POLICIES

BROOKLIN OFFICE NEWMARKET OFFICE HUNTSVILLE /HALIBURTON OFFICE


brooklinsales@brooklin.com newmarketsales@brooklin.com huntsvillesales@brooklin.com

T: 905-655-3311 1-800-655-3430 T: 905-895-2373 1-888-407-6443 T: 705-789-2338 1-800-264-3302


F: 905-655-3847 F: 905-898-3264 F: 705-789-9829

62
Special Order Policy

It is Brooklin Concrete Products’ policy to request a deposit on


specially manufactured products that are produced or modified
to meet the unique requirements of a specific project.

A minimum deposit of 50% must be received before production


of the special order will begin.

This policy has been implemented to ensure the monetary


involvement of a purchaser ordering a tailor‐made product is
no reflection on a customer’s credit worthiness.

Special order products cannot be returned for refund.

63
Return/Exchange Policy

Items being returned for credit or exchange must be returned


within 30 days from the date of original sale. A minimum 25%
restocking charge will apply to ALL returned product. In order
for a credit to be issued, the product must be in its “original”
condition and accompanied by the purchase receipt. Product
that has been altered or damaged in any way will not be
accepted, or credited. We will not refund for product that has
been custom‐made (special order).

64
Septic Tank Delivery Policy

Many of our products are delivered to site on our self‐unloading crane


trucks. Precast Concrete sections weighing in excess of 2500kg that are
delivered to a jobsite on a Brooklin Concrete Products crane truck can
be placed in their permanent position only if proper access is provided
to a firm, flat, level and obstruction free area of sufficient size to
accommodate our vehicle. The center of the placement location must
be located directly to the rear of the crane truck and within 3 to 5
meters behind the vehicle. E.g. Depending on the size of the tank;
sections weighing less than 2500 kg are not normally placed but are
simply offloaded for others to move in to position. Our crane operators
are instructed to refuse to attempt any operation that may involve a
safety hazard, or may jeopardize our equipment.

Please see our installation guidelines for more information.

NOTE: We recommend a site inspection be arranged through the office if a


contractor is unsure of the placing of a tank e.g. 2500 gallon up to 6600 gallon

65
GUIDELINES & TESTING
OF TANK INSTALLATION

BROOKLIN OFFICE NEWMARKET OFFICE HUNTSVILLE /HALIBURTON OFFICE


brooklinsales@brooklin.com newmarketsales@brooklin.com huntsvillesales@brooklin.com

T: 905-655-3311 1-800-655-3430 T: 905-895-2373 1-888-407-6443 T: 705-789-2338 1-800-264-3302


F: 905-655-3847 F: 905-898-3264 F: 705-789-9829

66
Installation Guidelines

Site

The installation site must be accessible to large heavy crane


equipment. A firm, flat and level area of sufficient size to allow
maneuvering room for this type of equipment must be
provided. This area must be free of overhead wires, tree limbs,
or other above‐grade obstructions which could affect normal
crane operation.

Excavation

Excavation length and width should allow for a safe clearance


on all sides of the precast. To minimize stress on a tank or
chamber, it should be placed on a base of gravel or crushed
stone, minimum 150mm thick. Soil conditions must be firm and
stable.

67
Soil Conditions

Most of our precast tanks are designed for installation in firm


stable soil. Unless designed for such use our product warranty
is void where an installation involves saturated/unstable soils.
Regardless of any design enhancements the precast structure
must always be placed on a flat, firm supporting surface.

Back Filling

Back fill material must be free of boulders and large stones.


Back fill must be placed in layers progressively against the four
sides of the precast structure. When back filling with an
excavator do not drop back fill on the precast or in to the
excavation from a height greater than one meter. The wheels
or tracks of back filling equipment must be kept at least one
meter away from the tank or chamber. At no time should heavy
equipment come in contact with any part of the precast.

Compaction of fill around a tank can impose stresses sufficient


to cause failure of the walls. Discretion must be used in this
operation. Naturally large tanks with comparatively thin walls
should be backfilled and compacted to minimize this stress.

68
Joint Seal

1. The mating surfaces of the joint must be clean and dry. The
lower precast section should be placed in its final position in
the excavation. The joint of this section should be made clean
and dry, then mastic strips of sealant applied. Ensure that the
ends of each strip overlap by a minimum of 26mm as the
sealant is laid around the joint.

2. Using lifting equipment that is safely adequate for the job,


hoist each subsequent precast section a few feet above the
ground in an open area away from the excavation. The joint
surface of this section must now be inspected. A broom should
be used to sweep away adherent debris. Care must be taken
that the people preforming this task have ample room to
maneuver and do not at any time work directly under the
hanging load. Should it prove impossible to clean the joint
properly in this way, the section must be safely blocked up in
position to allow access from underneath.

3. Once the joint surfaces are clean, dry, free of debris and
extra mastic has been applied in areas where the male or
female joint might have been chipped or broken in handling,
the upper section can be carefully set directly onto the lower
section.

69
4. Allow the structure to stand until the mastic is completely
crushed in to all parts of the joint and it stops extruding from
the sides. Remove the excess mastic and ensure the outer wall
is clean and dry in the area 8” above and below the joint. Apply
TWO COATS of mastic primer using a paint roller to the outer
wall surface. (8” above and below the joint)

5. Apply the mastic membrane to the primed area making sure


it is centered over the joint. The protective paper backing
should be removed progressively as the mastic band is applied.
Using a roller or other blunt shape, push the mastic firmly on to
the primed surface rolling out any ripples or folds.

6. An overlap is necessary when joints occur in the mastic band.


Apply primer to back of the section that will be overlapped
approximately 12”. Place the overlapping end on to the primed
section and roll in to place.

70
Testing
Pipe Connections

Fill the tank with water to 18 inches (460mm) above the


connection at the outside of the tank for a suitable period of
time; usually between 2 ‐ 24 hours. If no leaks occur around the
pipe in the suitable period of time, backfill around pipes and
compact the soils before backfilling to the joint.

Joint

Fill the tank with water to 18 inches (460mm) above the joint.
Observe the outside of the tank at the joint for a suitable
period of time; usually 2 – 24 hours.

Assembled Tank

Fill the tank to the underside of the roof slab or to a point up


inside the access riser. This access riser should be a one piece
casting integral with or mechanically connected and sealed to
the top of the tank. Note the liquid level, let stand for a suitable
amount of time and then check the level.

71
Caution: Filling the tank with liquid before
backfilling
Many of the precast tanks detailed in this catalogue rely on
support from the surrounding earth, in which they are buried,
to resist stress imposed by the contained liquid. It is
recommended that the tank at no time be filled higher than 24
inches (600mm) above the lowest outside level of backfill.

72
BROOKLIN OFFICE NEWMARKET OFFICE HUNTSVILLE /HALIBURTON OFFICE
brooklinsales@brooklin.com newmarketsales@brooklin.com huntsvillesales@brooklin.com

T: 905-655-3311 1-800-655-3430 T: 905-895-2373 1-888-407-6443 T: 705-789-2338 1-800-264-3302


F: 905-655-3847 F: 905-898-3264 F: 705-789-9829

WWW.BROOKLIN.COM

You might also like