GENERAL INFORMATION PROGRAMMING THE TIMER #1

This Panel-Mount Digital Timer A .Functional description to buttons on panel


series can be operated in 4 1. TIMER : Programs review & setting programs
separate power supplies,ranges 2. MANUAL : To select “ ON , AUTO or OFF ”
from 240 Vac to 12 Vdc. Output 3. CLOCK : To adjust current DAY and TIME
format can be produced to be 4. Day : To adjust day of week
Volt-free or voltaic-ouput. 5. HOUR : To adjust Hour
6. MIN : To adjust minute
Batteries of Lithium CR2032 or 7. P : Reset Timer’s setting
rechargeable V80H available for 8. LED : To indicate ON/OFF status
option which is for retaining
the programing during Timer’s Press P button to reset Timer before programming
operating power disconnected. TM-619-series
B.Adjusting CLOCK
Press and hold CLOCK and then press DAY key, HOUR key,
This Digital Timer is accurate to the minute, designed with MIN key respectively to adjust clock of Timer to accurate DATE,
either 6 or 8 ON/OFF(event) per day Graphic description, HOUR, MINUTE . In 12-Hour-Format, PM & AM shall appear on LCD
as below: screen. In 24-Hour-Format LCD screen shall indicate 0:00 ~23:59
ON
OFF Programmed Input
C. Start to programming the TIMER
Time line 1. Press TIMER key. LCD screen shall show
--
ON
1 - - : - -
Timer output status
2. Press DAY key to select any of 15-combination
Also ,it provides 15-combination of Daily-Programs which can of Daily-Programs to your application demand.
lead great convenience to users upon choosing the required Continuing to press DAY key, LCD shall alternating
days in a week for operating the timer. indicate among 15-combinations.
1. MO TU WE TH FR SA SU
3. Press HOUR , MIN respectively to set
2. MO
desired Hour and Minute for 1ON
3. TU
ON
4. WE 4. After finished setting of 1 , Press TIMER key again,
5. TH shall appear on LCD screen.
--
OFF
1 --:--
6. FR
7. SA 5 . Press DAY key to select any of 15-combination
8. SU of Daily-Programs to your application demand.
9. MO TU WE TH FR Continuing to press DAY key, LCD shall alternating
10. SA SU indicate among 15-combinations.
11. MO TU WE TH FR SA Day-combination chosen in each of ON/OFF
12. MO TU WE program-period must be consistent.
13. TH FR SA
14. MO WE FR 6.Repeat Programming procedure “3 “ to set desired
15. TU TH SA Hour & Minute for 1OFF
OFF
&1
ON
7. When finished setting 1 , Press TIMER ,
DESCRIPTIONS TO MODEL CODE
--
ON
2 - - : - - shall appear on LCD screen.
1.12H or 24H clock format 2. 6 or 8 on/off per day
3.Lithium CR2032 or rechargeable V80H batteries
above 3 items are prefixed at production. 8. Repeat programming procedure above to complete
rest of ON/OFF program-period(event)
OFF
-- 2 - - : - - --
ON OFF
: Volt-Free contact, 250Vac/16Amp Rating 1 --:-- 8 - - : - - --
H : Volt Output, 250Vac/20Amp Rating or just to the desired number of ON/OFF(event)
L : Volt Output, 250Vac/16Amp Rating setting for demand of practicable application.
OFF
1 - - : - - -- 2 - - : - - --
ON
1 - - : - - --
OFF ON
5 - - : - - --
9.When finished program-setting(event),
press CLOCK , Timer shall start to execute programs.
TM-619 --1~4 TM-619H--1~4 TM-619L--1~4
D. To review programs
Timer’s Keep to press TIMER , display on LCD screen
Model Number shall alternating display among each of
6 or 8 ON/OFF
1 ~ 4 Power supply for Timer
1: 120Vac ± 10%
2: 240Vac ± 10%
3: 24Vac/Vdc
4: 12Vdc B1-61900-003B0
VER:20091112
PROGRAMMING THE TIMER #2 PROPOSED APPLICATION
E. How to use OVERRIDE functions Output terminal of Timer is
DANGER
619-programming-modeTimer is designed with produced with Flat-head
2 Override function, so as to widen its usage upon Electric Shock Or Fire Hazard Jack-Type socket to provide
practicable application. Override function convenient electrical wiring
READ ALL WIRE SIZING, VOLTAGE REQUIREMENT AND SAFETY
DATA AVOID PROPERTY DAMAGE AND PERSONAL INJURY

is effective only when Timer is running upon mounting Timer on


under AUTO mode. equipments.
Subject to output formats and formats of Contact Rating,
Temporary-Override --- Follow procedure below: there are 3 different styles in TM-619-series.

Condition-1 When Timer’s output status is “ ON ” Remark:


Pressing MANUAL key, to move indicator 1. For voltage and electrical RATING information,
from “ AUTO “ to “ OFF”, Timer output shall turn please refer to the markings on the back of timer.
to “ OFF” status, programs overrided. 2. See the back of timer for proper wire connections.
Pressing MANUAL again to switch Timer status 3.Timer may need to be connected to power source
to “ AUTO “, Timer’s output shall continue in order to set the program.
maintaining “ OFF “. Timer shall resume its automatic
operation when next program(event) calls for “ ON “. Follow graphic description below & Refer to section of
(With next opposite set point). Descriptions to Model Code on this instruction-sheet
upon proceeding electrical wiring.
Condition-2 When Timer’s output status is “ OFF ”
Pressing MANUAL key, to move indicator from
“ AUTO “ to “ ON”, timer output shall turn to “ ON” 1.TH-619 - 1~4 Volt Free output
status, programs overrided.
Input voltage
Pressing MANUAL again to switch Timer status 1.
to “ AUTO “, Timer’s output shall continue maintaining 2.
“ ON “. Timer shall resume its automatic operation 3.
4. L
when next program(event) calls for “ OF “.
(Until next opposite set point) Load N

L N COM NC NO

R andom-Start-Up Override – Press and hold DAY P


key and then press MIN key. There shall be a symbol
shows on left corner of LCD screen, to indicate
this Override in executing.
2.TH-619L - 1~4 Volt output
When this Override is being executed, the original
Input voltage
programs will be stopped, and once every
1.
10 to 120 minutes Timers shall automatically 2.
turn its output to “ON” status. 3.
4.
Load
In practicable application which is applied to
home-use, this Override function also called Anti-Burglar
Override. L N

Once again to press and hold DAY key, and then


press MIN key shall terminate this Override. 3.TH-619H - 1~4 Volt output
Input voltage
1. 30Amp 250Vac 50/60Hz
1HP 125 Vac, 2HP 250Vac
HOW TO REPLACE BATTERIES 2.
3.
20Amp 30Vdc

4. Load
For Model with Lithium CR2032

L N

To replace Battery

B1-61900-003B0
VER:20091112

You might also like