You are on page 1of 4

Specification Sheet Models VH100 – VH200

Product Dimensions – Alloy Combustor


mm [inches]

190 B.C.
278 7.5
4X 12 THRU
10.9
.5

220
8.7

141
5.6

22 138
.9 1.5" NPT 5.4
105 248
4.1 9.7
3.0" NPT

227
B
8.9

218
8.6

504
19.9

B
Size: Part No.: Job No.:
7001-8001 ASDI STD
ALLOY COMBUSTOR CONFIGURATION Title:
VH-SIZE-4, DETAIL
Scale: Dwg. No.: Sht. No.: Rev.:

1:4 AND NOTED 7001-8001 3 of 4 C



Combustor outlet diameter
Combustor length
Model (“A”)
(“B”)
High Velocity Medium Velocity
VH100 Ø54.0 [2.1] Ø76.5 [3.0] 227 [8.9]
VH150 Ø63.5 [2.5] Ø89.0 [3.5] 227 [8.9]
VH200 Ø85.0 [3.4] Ø105.0 [4.1] 257 [10.12]

Inside dimension of the combustor outlet

© Copyright 2022 Algas-SDI version: 10/19/2022


VH100 – VH200 Specification Sheet

Product Dimensions – Ceramic Combustor


mm [inches]

279 190 B.C.


278
11.0 7.5
4X 12 THRU
10.9
.5

220
8.7

148 141
5.8 5.6

24
22 138
.9
.9 1.5"
1.5"NPT
NPT 5.4
105
107 248
4.1
4.2 9.7
3.0" NPT
3.0" NPT

227
227
B
8.9
8.9

A
A

218
8.6
219
8.6
504
506
19.9
19.9
B
Size: Part No.: Job No.:
7001-8001 ASDI STD
ALLOY COMBUSTOR CONFIGURATION B
Size: Part No.: Job No.:
7001-8001
Title: ASDI STD
VH-SIZE-4, DETAIL
CERAMIC COMBUSTOR CONFIGURATION Title:
VH-SIZE-4,
Scale:
DETAIL Dwg. No.: Sht. No.: Rev.:

Scale: Dwg. No.: 1:4 AND NOTED 7001-8001


Sht. No.: Rev.: 3 of 4 C
✻ 1:4 AND NOTED 7001-8001 4 of 4 C
Combustor outlet diameter
Combustor length
Model (“A”)
(“B”)
High Velocity Medium Velocity
VH100 Ø54.0 [2.1] Ø76.5 [3.0] 227 [8.9]
VH150 Ø63.5 [2.5] Ø89.0 [3.5] 227 [8.9]
VH200 Ø85.0 [3.4] Ø105.0 [4.1] 257 [10.12]

Inside dimension of the combustor outlet

© Copyright 2022 Algas-SDI version: 10/19/2022


VH100 – VH200 Specification Sheet

Model Specifications

Model Parameter VH100 VH150 VH200


Maximum Input, BTU/hr 1,000,000 1,500,000 2,000,000
Minimum Input, BTU/hr (On-ratio) 100,000 150,000 200,000
Minimum Input, BTU/hr (Fixed Air) 20,000 30,000 40,000
Combustor Type HV MV HV MV HV MV
High-velocity (HV), Medium-velocity (MV)
Inlet Fuel Pressure, “w.c. Natural Gas 12.5 5.5 14.5 7.0 9.3 7.1

Propane 15.0 8.0 11.0 8.0 13.0 11.0


Inlet Air Pressure, “w.c. Natural Gas 16.5 9.0 17.5 9.5 12.3 10.0
10% excess air at maximum input

Propane 17.0 8.0 14.0 6.0 17.0 13.0


High fire Visible Flame Length, Natural Gas 33 38 38 43 34 38
inches
Measured from the outlet end of the
Propane 34 37 42 44 36 38
combustor
Approximate Flame Velocity, ft/s 600 300 650 340 480 320
Approximately 10% excess air at maximum output
Maximum Operating Temperature, Alloy
1,750
°F combustor
Ceramic
combustor
2,500
Maximum Combustion Air Temperature, °F 300
For higher temperatures contact Algas-SDI
Flame Detection Flame Rod For operating temperatures up to 2,200°F No

UV Scanner Yes
Fuels Natural gas or Propane
For any other mixed gas, contact Algas-SDI
Burner Weight, lbs 47 47 47

§ All information is based on laboratory testing in neutral (0”w.c) pressure chamber.


Different chamber conditions may affect the data.
§ All inputs based upon standard conditions; 1 atmosphere, 70°F, and higher heating values (HHV).
§ Algas-SDI reserves the right to change the design and/or configuration of Algas-SDI products.

© Copyright 2022 Algas-SDI version: 10/19/2022


VH100 – VH200 Specification Sheet

Setup Specifications
∆P Across Orifice vs. Input (On-ratio operation)

Input BTU/hr
Taps Orifice Size (mm) 500,000 750,000 1,000,000
Natural Gas C-D 18.0 1.0 2.0 3.6
VH100

∆P Across Orifice Propane C-D 13.0 1.0 2.2 4.2


(“w.c. ± 5%)

Air A-B 57.0 1.5 3.2 6.4


750,000 1,125,000 1,500,000
Natural Gas C-D 20.0 1.0 2.6 4.2
VH150

∆P Across Orifice Propane C-D 18.0 0.75 1.5 2.6


(“w.c. ± 5%)

Air A-B 66.0 1.5 3.2 6.6


1,000,000 1,500,000 2,000,000
Natural Gas C-D 24.0 1.0 2.4 4.2
VH200

∆P Across Orifice Propane C-D 18.0 1.3 2.6 4.4


(“w.c. ± 5%)

Air A-B 70.0 1.6 3.6 6.0

§ Plumbing of air and gas will affect accuracy of orifice readings.


§ Information is based on acceptable/industry-established air and gas piping practices.

Pressure Tap Locations

© Copyright 2022 Algas-SDI version: 10/19/2022

You might also like