- 411 -
Floors ventilation. The openings were modeled with their
The building has two types of floors, flooring and dimensions and percentage of glass according to the
hydraulic tiles. Hydraulic tile is used on the ground survey of restoration. The wooden window was
and in terraces. The flooring is used in part of the configured as internal solar protector.
ground and in the entire second floor.
The hydraulic tile was simplified with a layer of
hydraulic tile of 0.01 m and a layer of light concrete
of 0.07 m.
On the ground floor, the flooring was considered
with wood, air and land layer. (Figure 7)
- 412 -
Occupancy Ground temperature
The occupancy was calculated the same way as the Soil temperature was obtained through Slab,
thermal gains were. First, a survey on the number assistant program of EnergyPlus, which calculates
of people that occupy the House during working the monthly mean temperature of the soil from the
hours was fulfilled. Two areas are art galleries and internal air mean temperature and the external mean
had their occupancy calculation based on NBR temperature.
9077. The number of occupants was defined to each
Modelling challenges
ambient individually.
The type of activity performed by the occupants is The greatest challenges found during the simulation
also important to the configuration of the process of the Casarão, were related to modeling.
occupancy and it was considered as light office The building has different thicknesses of external
service, Met value equals 1. Winter wearing value and internal walls, situation that cannot be
equals 1 Clo and Summer wearing equals 0.5 Clo represented in the modeling in DesignBuilder. The
(the winter wearing value is equal 1 Clo and walls were, therefore, modeled with equal
summer wearing is equal 0.5clo) thicknesses and later configured in aba
‘construction’ with individual characteristics of
Natural ventilation
each one. The surveys obtained show that the walls
Natural ventilation was configured by schedule. are not orthogonal, where a simplification to
The windows are opened to allow ventilation from facilitate the modeling and avoid conflict between
the setpoint temperature. Wood-wickets configured adjacent surfaces of different blocks of the building
as solar protector were configured with percentage is necessary. In the specific case of simulating
of air flux permeability (airflow permeability) of building in Brazil, the generation of all materials to
11%, calculated from the window opening as use in the process is demanded, thus the library in
Figure 10 shows. the program is very different from the reality here.
Windows were modeled from the percentage of
glass and frames, and the working system was
configured from the percentage of opening for
ventilation.
The process would be easier and more accurate if
modeling allowed that even non-parallel surfaces
could be joined, forming one unique block.
Drawing walls of different thicknesses and not
necessarily perpendicular, would guarantee walls
overlapping.
RESULT ANALYSIS
The data obtained were evaluated from adaptive
model De Dear and Brager, to ASHRAE Norm 55.
Such model considers the external temperature as
reference to naturally ventilated ambient. The users
must have free access to windows that must open
outwards and have the possibility to adapt their
clothing as well. Therefore, the mean air
temperature and the radiant temperature are used to
calculate the operative temperature and stipulate the
acceptable levels of comfort to 80 and 90% of
people satisfied, considering the external
Figure 10 - window shade airflow permeability temperature. Mean external temperature shall be
between 10 and 30°C. In order to stipulate
Setpoint of temperature operative temperature of comfort the following
The ventilation temperature setpoint of 25°C was formula is used:
based on the work of Martins (2009). The system of Toc = 18.9 + 0.255Text . (2)
natural ventilation promotes the opening of the
windows when the exterior temperature is inferior To determine 90% of people satisfied, the operative
to the interior temperature of rooms and inferior to temperature of comfort is the interval of Toc -2.2°C
25°C. and Toc +2.5°C and to 80% of people satisfied it is
Toc -3.2°C and Toc +3.5°C.
For first analysis, the results were from all hours of
the year, to 90% of people satisfied, resulting in
- 413 -
48.70% of hours inside the acceptable limits of 100%
comfort, with 13% of discomfort by cold and
cold
38.30% of discomfort by heat. Considering the 80%
limits of temperature stipulated to the interior of the 66%
60% heat
building, the external temperature throughout the
year was in the limits in 20.25% of the time.
40% 27% 28,21% comfort
(Figure 11)
20% 7% external
100% comfort
0%
cold
80% 80% acceptability
- 414 -
80% NOMENCLATURE
70% ρ, density of apparent mass;
60%
50% M, mass;
40% cold V, volume;
30% Toc , Operative temperature of comfort;
20% heat
10% Text, External monthly mean temperature;
0% comfort
AKNOWLEDGEMENTS
June
January
May
February
March
July
September
October
December
April
August
November
The authors would like to give thanks to CAPES
for the support for the accomplishment of this
research.
Figure 15 – Monthly results for 90% acceptability
BIBLIOGRAPHY
Considering 80% of acceptability, where tolerance
ABNT – ASSOCIAÇÃO BRASILEIRA DE
is greater, it is possible to verify milder results, but
still responding to specific climate variations of the NORMAS TÉCNICAS. NBR 15.220. Norma
region. January presents discomfort because of heat Brasileira de Desempenho Térmico para
in 60% of occupancy hours. And June shows Edificações de Interesse Social, Parte 2:
discomfort because of cold in 42% of the time, as Métodos de cálculo da transmitância térmica,
Figure 16 shows. da capacidade térmica, do atraso térmico e do
fator solar de elementos e componentes de
90% edificações. Rio de Janeiro: ABNT, 2005.
80%
70%
60% ____. NBR 15.220. Norma Brasileira de
50% Desempenho Térmico para Edificações de
40% cold
30% Interesse Social, Parte 3: Zoneamento
20% heat
10%
bioclimático brasileiro e diretrizes construtivas
0% comfort para habitações unifamiliares de interesse
June
January
February
May
October
April
August
March
July
September
December
November
- 415 -
LAMBERTS, R.; DUTRA, L.; PEREIRA, F. O. R. Ministério da Cultura – Patrimônio Vivo, Pelotas –
Eficiência Energética na Arquitetura. 2a RS. Brasília, DF: IPHAN / Programa
edição. São Paulo: ProLivros, 2004. Monumenta, 2007
MARTINS, D. J., RAU, S. L., RECKZIEGEL, S., ORDENES, M., PEDRINI, A., GHISI, E.
FERRUGEM, A. P., SILVA, A. C. S. B. LAMBERTS, R. Metodologia Utilizada na
Ensaio Sobre A Utilização Da Automação De Elaboração da Biblioteca de Materiais e
Aberturas Na Simulação Do Desempenho Componentes Construtivos Brasileiros para
Térmico De Edificações. In: X Encontro Simulações no VisualDOE – 3.1. Laboratório
Nacional e VI Encontro Latino Americano de de Eficiência Energética em Edificações.
Conforto no Ambiente Construído. Anais. Universidade Federal de Santa Catarina.
Natal, 2009. Florianópolis, 2003.
- 416 -