You are on page 1of 1

VERDANA HOMES RECOMMENDING APPROVAL:

PLANTAZIONNE

APPROVED:
north
GENERAL SPECIFICATIONS: HEAD MECHANICAL SECTION : DATE

SCHEDULE OF MACHINERIES
1. ALL MECHANICAL INSTALLATIONS SHALL CONFORM
TO THE RULES & REGULATIONS OF C.A. 294 ROBINSON'S PLACE
CIRCUIT MOTOR LOCATION DESCRIPTION REMARKS BUILDING OFFICIAL DATE
OTHERWISE KNOWN AS THE MECHANICAL ENG'G.
LAW OF THE PHILS.
CKT FCU 1 LIVING ROOM 2.0 HP SPLIT TYPE
PROVINCIAL
MANDALAGAN
2. ALL MECH'L. INSTALLATIONS SHALL BE UNDER CAPITOL BLDG
JOLLIBEE
THE SUPERVISION OF A LICENSE PROF. MECH'L. ENGR. BUSINESS INN CKT FCU 2 LIVING ROOM 2.0 HP SPLIT TYPE
MCDONALDS
HOTEL

3. ALL BELTINGS AND GEARS SHALL BE PROVIDED BACOLOD


RECLAMATION CKT FCU 3 MASTER'S BEDROOM 1.0 HP SPLIT TYPE
WITH BELT GUARDS AND CASINGS AREA

4. CONCRETE MIXTURE MUST BE CLASS "A" CKT FCU 4 BEDROOM 1 1.0 HP SPLIT TYPE

CKT FCU 5 BEDROOM 2 1.0 HP SPLIT TYPE


BACOLOD AIRPORT

3 VICINITY MAP
NOT TO SCALE
M-01
A C
A1 B D E
450 11105 3050

F A D"
4000 675 2000 5480

A1 B D D' E F
11105

450 4000 1625 1325 4155 3045


LANAI SUCTION PIPE
ACCU 1 ACCU 2
LIQUID PIPE

5 FCU1 -2.0HP
AIR DISCHARGE
GRILLE OUTLET
FIELD WIRING CKT. BREAKER

MAID'S 5 AIR SUCTION


GRILLE INLET
OVERHEAD CABINET

ROOM FCU3 - 1hp FCU4 - 1hp CONTROL PANEL


DRAIN PIPE
RANGE
KITCHEN

SHELVE

SHELVE
4900

RANGE HOOD
MASTER'S

4450
LIVING DINING BEDROOM
SINK BEDROOM GROUNDING WIRE
1
AIR OUTLET
LAUNDRY/
1100

FAN GUARD
DRYING
2300
LT
4' 3 WALL MOUNTED ACU DETAIL
9350

NOT TO SCALE
9350

M-01
4
450

FCU2 -2.0HP
MAID'S
DM 4 18

17
DN

16

PANTRY T&B WM
POWDER 15
WINDOW SEAT
2750

2750

ROOM 14

FOYER POWDER STO. 13

ROOM 12

11 11

10 10
FAMILY DEN/ GUEST RM ACCU 3
MIRROR
9

3 1 2 3 4 5 6 7
9

8 3 1 2 3 4 5 6 7 8
ACCU 4 LEGEND
1700
1700

UP FCU5 - 1hp
GARAGE ACCU 5

2 2 ACCU (OUTDOOR UNIT)


2005
2005

WALL MOUNTED
FCU (INDOOR UNIT)
1
1
1005

RANGE HOOD

1 GROUND FLOOR MECHANICAL LAYOUT 2 SECOND FLOOR MECHANICAL LAYOUT


SCALE 1:100 METERS SCALE 1:100 METERS
M-01 M-02

THIS DRAWINGS DULY SIGNED, STAMPED OR SEALED, PROJECT TITLE : PROJECT OWNER: SHEET CONTENTS CADD JEPHTI SHEET NO.
AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL
PROPERTIES AND DOCUMENTS OF THE ARCHITECT,
WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS VICINITY MAP DATE 6 - 27 - 2013
PROFESSIONAL MECHANICAL ENGINEER EXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR ANY GROUND FLOOR MECHANICAL LAYOUT
PERSON, WITHOUT THE CONSENT OF THE ARCHITECT
SECOND FLOOR MECHANICAL LAYOUT CHECKED RYAN
OR AUTHOR OF SAID DOCUMENTS TO DUPLICATE OR
PRC NO. : 03430 VALIDITY : 10 FEB 2016 TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE FILE PATH STATION J
PTR NO. : 03322260 DATE : 26 MAR 2013 REPETITION OF AND FOR OTHER PROJECTS OR
BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE.
PLACE : MANDAUE CITY TIN : 119-265-987 - R.A.9266 ARTICLE IV, SECTION XXXIII
LOCATION: PLANTAZIONNE, VERDANA TALISAY CITY, NEGROS OCCIDENTAL ADDRESS: PLANTAZIONNE, VERDANA TALISAY CITY, NEGROS OCCIDENTAL UPDATED