DBITS,PILANI— DUBAI CAMPUS FIRST SEMESTER 2019 - 2020 EEEVINSTR/ ECE F211 ELECTRICAL MACHINES TEST 1 (CLOSED BOOK) MAXIMUM MARKS: 30, WEIGHTAGE: 15% DATE: 24.09.19 DURATION: 50 MINUTES "NOTE: 1) Ifa question is answered wvice and no encelled, ony the fist tempt wil be evaluated. 2) Show ealulations stepwise. 3) Sketches! diagrams are tobe complete, 1A SRVA, 200 /400 V, 50 Hz, single phase transformer when tested gave the following results: 0C tes, measurement on LY sie: 70 W, 0.7 A, 200 V SC tet, measurement on HV side: 85 W, 10, 15 V |A) Is the SC test done at accurate current level? If net, mention the corect SC test readings of watt meter and ammeter. B) Determine (the ternal voltage on the HY se, (i) its percentage regulation when it supplies fl load at 08 power factor leading, the supply voltage being 200 V. (©) At what pf, will the percentage regulation be 220? 'D) At what pf, wil the peteentage regulation be maximum’? past) 2. A 100 KVA, three phase, 50 Hz, 3300/400 V, AV Y connected transformer has primary resistance of 3.5 0 and secondary resistance of 0.02 Q per phase. If iron loss is 1700 W, determine te efficiency when it supplies full lod a 08 power factor lagging. [10M], 3, The HY terminals of 3-phase bank ofa thee single phase transformers are connected to £3 wir, thee phase, 66 KV (line-o-tine) system. The LV terminals are comneced ta 3 ‘wire, thre phase balanced load rated of 6000 KVA at 33 RV (lne-o-line) Calula the ‘voltage rating (frimary side to secondary side ratio) ofthe single phase wansformer for the following 3-phase transformer connections ayy BY/a ary Dara tot) BITS, PILANI— DUBAI CAMPUS FIRST SEMESTER 2019 - 2020 EEE/INSTR/ ECE F211 ELECTRICAL MACHINES TEST 2 (OPEN BOOK) MAXIMUM MARKS: 40 WEIGHTAGE: 20 % DATE: 12:14. 2019, DURATION: 50 MINUTES ‘NOTE: 1) Only prescribed text book and hand written class notes are allowed. 2) Ifa question is answered twice and not cancelled, only the firs atomps wll be evaluated. 3) Show calculations stepwise ) Sketches diagrams sre to be complete 1. A200 V de shunt motor takes a line curent of 10 A when running on nodoed Calculate the following. if amature and feld resistances are 02 and 100 C2 respectively. 8) Efficiency asa generator ata load current of 100 A b) Maximum efficiency a5 a generator ‘©, Which type of loss can not be determined by Swinbure's test and how thie is estimated? 112M) 2. Atarated load, a 250 V de shunt motor runs at 1140 rpm, delivering a net torque of 83.76 Nem to the shaf, drawing @ line curent of 50 A. "The foal armature ieut resistance Ra is 0.5 Q and field resistance RF is 200 0. Assume armature reaction demagnetizes the field by 4%, Calculate the following at no-load conditions ') Torque developed by Speed ©) Rotational losses tM) 3. Which type of motor can never be run on no-load? Why’? Mention a mgjoradvattage this motor offers, PM) 4. An 8 pole, 3 phase, 50 Hz induction motor is running at a speed of 710 spm wih an input power of 35 kW. The stator loses at this operating candition i 1200 W while ‘the fection and windage losses afe 600 W. Find the following: 4) gross torque and gross mechanical power ‘net orque and net mechanical power «) olor copper loss frequency of rotor emt fam [BITS, PILANI~ DUBAT CAMPUS FIRST SEMESTER 2019 - 2020 EEE/INSTRI ECE F211 ELECTRICAL MACHINES (COMPREHENSIVE EXAMINATION (CLOSED BOOK) MAXIMUM MARKS: 60 WEIGHTAGE: 30 % DATE: 18.12.2018, DURATION: 3 HOURS, eee "NOTE: 1) Ifa question is answered twice and not cancelled, only the frst, attempt wil be evaluated, 2) Show calulations stepwise 3) Sketches/ diagrams are tobe complete, 1, A200 VA, $0 Ha, single phase transformer has 98 % efficiency at fl oad 0:8 powe: factor lagging, H the maximum efficiency occurs at three-ourh of fll load, determine the folowing: ie, A) ron loss 8) Full load copper loss © Bificieney at thre-fourth fl load, unity power fate. 2. A100 KVA, three phase, 30 Hz, 33001400 V, AY Y connected, transformer has prinasry resistance of 3.5 @ and secondary resistance of 0.02 0 per phase. Secondary equivalent impedance (Zen) 0.16 2 pee phase |A) Determine () Secondary voltage and (i) its percentage regulation wen it supp ies ful oad a 0.8 power factor lagging, wih rated primary voltage. 'B) At what pf, will the percentage regulation be zero? (© At what pf, will the percentage regulation be maximum? om 3, A250 V de shunt motor takes a line curent of SA when running on no-load Its mature ad field resistances are 0.5 and 250 0 respectively |A) Caleulite efficiency a8 a moto at line curent of 28. 1B) Maximum efficiency asa motor 10M) 4. A.220V, 4 pole, DC shunt generator with « shunt eld resistance of 100 0 and an armature resistance of 1 has 378 wave-connected conductors in its armature. The fux TiPate 5 por pole is 0.02 Wb and its runing at 1000 rpm. Ifthe machine is now operated as 8 ‘motor atthe same terminal voltage withthe same armature current, calculate the molor speed, Assume tat the flux per pole is made to decease by 10 % as the operation is changed over from genertor to motor. My ‘AG ole, 50 Ha, 3 phase induction mator uns 960 spon ful oad with rotor curent pe phase of 35 A. I the net power developed by moor is 18.65 kW, andi estimated that eon and windage losses ae S00 W, fing the flloing a ilo 28) Resistance pe phase of3 phase rotor wining 1) Power ares sireap ©) Grosstorgue 4, Trguein synchronous wats oo) For 3 phise induction moter, Starting fom the basi torque equation T= @ Ir cos 0),

You might also like