BIEN-AIR REPAIRED PRODUCT INSPECTION INSTRUCTION IC 751-015 Rév.
0005 SWITZERLAND
INSTRUCTION N o : 12 Modified 18.12.09
CONCERNED ARTICLE CONCERNED ARTICLE
DESIGNATION OLD REFERENCE NEW REFERENCE DESIGNATION OLD REFERENCE NEW REFERENCE
PM 830 131.11.01A -- CA 10:1 41 133.38.01C 1600038C
C PML 1:1 21 131.12.01 A 1600156 A CA 10:1 133.38.03 1600385C PM 1122 131.16.01A -- CA 10:1 31 133.39.01 1600425 A A A A PM 1132 / 1123 131.22.01 / 131.22.02 1600054 / 1600052 CA 100:122 133.40.01 1600201 A 133.41.01 1600290 PM1132 Sudo 131.22.03 -- CAP 15:1 21 A A 133.42.01 1600319 PM 1132 131.22.10 1600404 CAP 15:141 PM 1:1 131.22.12A 1600383A CAE 10:1 41 133.46.01C 1600050C PM 1124 -- 1600612 CAE 10:1 31 133.47.01 1600051 A A A A PM 860 / 861 131.24.01 / 131.24.03 -- / -- PMRM 111 / 1122 131.18.02 / 131.18.04 -- / 1600206A PMP 10:1 21 131.27.01 A 1600289 A PMRM 1122 INTRA-NASAL 131.18.06A 1600329A CA 111 133.03.01 -- PMRM 1122/95 INTRA-NASAL 131.18.07 A 1600340A CA 1:1 21 133.08.01 -- PMRM 1122/125 INTRA-NASAL 131.18.08 A 1600341A CA 1141 133.24.01B -- PMAM 111 / 1122 133.06.02A / 133.06.03 -- / 1600207 CA 7141 133.25.01 B -- PMAM 1122 INTRA-NASAL 133.06.04A 1600328A CA 1132 133.27.01 1600055 PMAM 1122/95 INTRA-NASAL 133.06.05A 1600336A CA 1122 133.08.05 1600200 PMAM 1122/125 INTRA-NASAL 133.06.06 A 1600337A CA 30:122 133.52.01 1600284 PMAM 1221 133.15.01A 1600295A A CA 7132 133.28.01 1600056 PMAM 1221/95 133.15.02 1600338A A CA 1142 133.32.01C 1600061C PMAM 1221/125 133.15.03 1600339A CA 1:1 133.32.06C 1600384C PMAM 10121 133.16.01A 1600202A CA 1:1 33 133.34.01 1600424 PM FISCH PM MICRO 1600470A C CA 1:1 sp. ext. -- 1600603 CA 20:1 L 1600598 PM HP 1:2 -- 1600436 CA 20:1 1600632
Inspection UNIT, TOLERANCES AND EVALUATION
INSPECTION CRITERIA instrument Ok CRITERIA LUBRICATE THE INSTRUMENT BEFORE INSPECTION 1600064 Lubrifluid PROGRESSIVELY (STEP BY STEP) RUN THE 107.70.01 / Inspection rack HANDPIECE/CONTRA-ANGLE 107.70.02 RUN IN THE HANDPIECE/CONTRA-ANGLE 3 min at 30'000 rpm and 2 min at 40'000 rpm MEASURING OF THE CURRENT ON THE INSPECTION 107.70.01 / Maxi 0.40 A RACK 107.70.02 AXIAL BUT GRIPPING ON HANDPIECE 107.61.02 Minimum holding red line 40 N A (tap the inspection gauge 2-3 times before the test) Holding 1st green line 45 N A AXIAL BUR GRIPPING ON CONTRA-ANCLE Left to the operator's discretion VIBRATION, NOISE Left to the operator's discretion OVERHEATING Left to the operator's discretion QUALITY OF THE SPRAY (air-water 2 bar) Left to the operator's discretion WATERTIGHTNESS OF THE HANDPIECE/CONTRA- No leak when the water/air outlet is blocked ANGLE LUMINOSITY A 3.5 VDC +/- 0.1 V* 3600001-001 B 1 klux minimum LUMINOSITY A 3.5 VDC +/- 0.1 V* 3600001-001 2 klux minimumC LUMINOSITY A 3.5 VDC +/1 0.1 V* Visual, white light CHECK COUPLING OF HANDPIECE OR CONTRA- Left to the operator's discretion ANGLE ON MOTOR DEVICE FUNCTIONING OF THE DRIVE Left to the operator's discretion OVERALL OUTSIDE ASPECT Left to the operator's discretion