You are on page 1of 1

SS 1032626 Successful Regen Reference for

EPA07 Series 60 Engines

Summary: When reviewing a parked regen with DDDL, it is important to know what parameters to
monitor, and what normal results look like. This guide will assist with diagnosing regen related codes
and issues for EPA07 Series 60 Engines.

Engine Speed 1600 rpm

Fuel Cut Off Valve 100% (On)

Throttle Valve Actual 85 – 88%

Fuel Comp Pressure 70 – 85 psi


Doser Fuel Line Pressure 20 – 30 psi
DOC Inlet Temp 653° F
DOC Outlet Temp 1103° F

DOC Outlet Model Delay 1110° F


(A drastic drop may indicate a bad doser block)

DPF Outlet Temp 1058° F


DPF Inlet Pressure 1.0 psi or lower

DPF Outlet Pressure 0.5 psi or lower


Doser Injection Status 9% – 14%

Inlet Manifold Pressure 7 – 9 psi with ITV closed


20 – 22 psi with ITV open

EGR Actual Valve Position 0%


EGR Commanded Governor Value 0%
Coolant Temp Must reach 140° F before the ITV closes
Main Injection Start 7° during regen
(If not at 7 and ITV is normal,
this may indicate injectors are
bad)