GENERAL ELECTRIC MODEL PG9171E Uprate GAS TURBINE


Estimated Perfomance - Configuration : Standard
Compressor Inlet Conditions 59F (15°C), 60% Relative Humidity
Atmospheric Pressure 14.7 psia (1.013bar)

Fuel NATURAL GAS


Design Output kW 125 800.
Design Heat Rate (LVH) kJ/kWh 10 700.
Design Heat Cons (LVH)*10^6 kJ/h 1 346.1
Design Exhaust Flow * 10^3 kg/h 1509
Exhaust Temperature °C 543
Mode BASE LOAD
Cycle Deck: IPS- Version Code - 3.8.1/182A0/3.8.0/PG9171-06A-0908
Notes:
1. Altitude correction on curve 416HA662 Rev B
2. Ambient temperature correction on curve 544HA933-2 Rev 1
3. Effect on modulating IGV's on exhaust temperature and flow on curve 544HA933-3 Rev 1
4. Humidity effects on curve 498HA697 Rev B - all performance calculated with a constant
specific humidity of .0064 or less so as not to exceed 100% relative humidity.
5. Plant Performances is measured at the generator terminals and includes allowances
for the effects of excitation power, shaft driven auxiliaries, and 3.5 in H20 inlet and 5 in H20
exhaust pressure drops
6. Additional inlet and exhaust pressure loss effects:
% Efffect on Effect on
Output Heat Rate Exhaust Temp.
4 in Water (10.0 mbar) inlet -1.45% 0.5% 2 °F (1.1 °C)
4 in Water (10.0 mbar) outlet -0.4% 0.4% 2 °F (1.1 °C)

130

120
0 °F
110
Heat Consumption - Percent Design

100
59 °F
90

80

70
120 °F
60

50

40

30

20

10

0
0 10 20 30 40 50 60 70 80 90 100 110 120 130
Generator Output - Percent

P. de NONANCOURT Number 544HA933-1


14/11/2008 Revision 1
GENERAL ELECTRIC MODEL PG9171E Uprate GAS TURBINE
Effect of compressor Inlet Temperature on
Output,Heat Rate, Heat Consumption, Exhaust Flow
And Exhaust Temperature at BASE LOAD

Fuel NATURAL GAS @ 80deg F


Combustor STANDARD

1060

1050
Exhaust Temperature (°F)

1040

1030

1020

1010

1000

990

980

970 and 3.5 in H20 inlet and 5 in H20


960
0 10 20 30 40 50 60 70 80 90 100 110 120

120

115

110

Heat Rate
105
Percent Design

100

95
Exhaust Flow
90

85 Heat Consumption

Output
80

75

70
0 10 20 30 40 50 60 70 80 90 100 110 120

COMPRESSOR INLET TEMPERATURE (°F)

P. de NONANCOURT Number 544HA933-2


14/11/2008 Revision 1
GENERAL ELECTRIC MODEL PG9171E Uprate GAS TURBINE
Effect of Inlet Guide Vane on Exhaust Flow and Temperature
As a function of Output and Compressor Inlet Temperature

Fuel NATURAL GAS @ 80deg F


Combustor STANDARD
1150
1100
1050
1000
950
Exhaust Temperature (°F)

900
850
0°F
800 30°F
750
59°F
700
650 90°F
600
120°F
550
500
450
400
0 10 20 30 40 50 60 70 80 90 100 110 120

120
0°F

110
30°F
59°F
100
Exhaust Flow - Percent Design

90°F
120°F
90

80

70

60

50

40
0 10 20 30 40 50 60 70 80 90 100 110 120
Generator Output - Percent

P. de NONANCOURT Number 544HA933-3


14/11/2008 Revision 1