Performance Scheme for Steam Atomising Oilburner

Plant name: Carnival Breeze / Boiler No. 1 Date: 31-3-2012


Boiler type/No:CHB – 15000 / 8119 Burner type/No: KBSA 1200 / 16394
Fueltype/quality: 380 cst at 50 degree centigrade Atomizer ID. No: 1200-6-8-85-1.25
dp-transmitter,range airflow: 0 to 360 mmWG Min. load: 25 %
Ign. load: 25 % Service Engineer: mlu
Measurements: A= 30mm ; B= 17mm ; C= 145mm ; D= 108mm
Load / fuel BURNER
1 flow % 25 30 40 50 60 70 80 90 100 STOP
2 Fuel amount L/h 270 320 420 550 650 780 880 990 1100
3 Fuel pressure at burner inlet Barg 2,4 3,1 4,8 6,5 8,2 10 11,2 12,8 14,6
4 Fuel temperature at burner inlet °C 108 108 108 109 110 112 114 116 116
5 Fuel oil pressure in ring line barg 20 20 20 20 20 20 20 20 20
6 Fuel temperature in tank °C 95 95 95 95 95 95 95 95 95
7 Atomising steam pressure barg 2,7 3,1 4 4,8 5,6 6 6 6 6
8 Air damper open on positioner % 6,7 8 11 16 20 26 33 44 57
9 Combustion air fan current A 21 21 23 25 26 29 33 37 43
10 Air temperature in windbox °C 34 33 32 30 29 29 28 28 28
11 Delta – P combustion air fan mm H2O 17 26 51 82 116 160 210 270 335
12 Delta – P combustion air fan mA 7,5 8,3 10 11,6 13,1 14,7 16,3 17,8 19,4
13 Fuel oil temperature in preheater °C 130 129 129 128 127 126 126 127 127
14 Static pressure in uptake mm H2O
15 Fluegastemperature in uptake °C
16 O2 in uptake % 6 5,8 6 6,3 6,5 6,5 6,5 6,8 6,8
17 Soot, “BACHARACH” No.
18 CO ppm
19 Smoke density unit % 0,5 0,5 0,5 0,5 0 1,5 2 2,5 3,5
20 Boiler pressure barg 8 8 8 8 8 8 8 8 8

Received by Fincantieri shipyard: ______________________________

Date: