You are on page 1of 4

CPP-1 BOILER & COMBUSTER DATA

LINE-1 GRADE N220


DATE
SR NO. PARAMETER UNIT
06.06.2022 26.04.2022
1 MAIN STEAM FLOW TPH 38.91 40
2 FD FAN-B IGV % 40 100
3 FD FAN HEADER PRESSURE MMWC 452 489
4 FD AIR TEMP ⁰C 45.3 33.7
5 AIR FOR OIL FLOW/IGV NM3/HR/% 4255/24 7100/40
6 AIR FOR CO FLOW/IGV NM3/HR/% 29186/70 31300/70
7 AIR FOR DILUSION FLOW/IGV NM3/HR/% 3707/35 4590/50
8 TOTAL AIR FLOW NM3/HR 37278 42990
9 TAIL GAS INLET PRESSURE MMWC 228 164
10 TAIL GAS TEMP ⁰C 226 225
11 TAIL GAS FLOW NM3/HR 36272 42974
12 COMBUSTER PRESSURE IN LOCAL GAUGE NM3/HR 100 -
13 COMBUSTER PRESSURE IN DCS NM3/HR 81/78 54
14 COMBUSTER TEMP ⁰C 1145/1147 1093/1054
15 EVAPORATOR INLET TEMP ⁰C 684 695
16 ECONOMISER INLET TEMP ⁰C 311 310
17 ECONOMISER DP NM3/HR 68 32
18 ECONOMISER INLET PRESSURE GAUGE NM3/HR 38 -
19 ECONOMISER OUTLET PRESSURE GAUGE NM3/HR -35 -
20 O2 ANALYSER READING % 2.8 4.4
21 STACK INLET TEMP ⁰C 194.7 191
1.027735 1.000372
ATE
26.04.2022
40
100
489
33.7
7100/40
31300/70
4590/50
42990
164
225
42974
-
54
1093/1054
695
310
32
-
-
4.4
191
Chart Title
100 4.50

90 4.00

80
3.50

70
3.00

60
2.50

50

2.00
40

1.50
30

1.00
20

10 0.50

0 0.00
76354 79971 84670 85565 89099 89005 89003 91640

Total Flue Gas Flow

ECONOMISER DP (DCS) O2 ANALYSER READING AIRFLOW/TAILGAS FLOW


CPP-1 BOILER & COMBUSTER DATA
LINE-1 GRADE N330 DATE: 07.06.2022
FD FAN-B FD FAN-B FD FAN-B FD FAN-B FD FAN-B FD FAN-A FD FAN-A FD FAN-A
SR NO. PARAMETER UNIT
11:15 12:00 12:30 12:55 13:30 14:30 14:50 15:15
1 MAIN STEAM FLOW TPH 39.15 41.5 44.57 46.93 47.8 47.71 47.07 50.23 61.7
2 FD FAN-B IGV % 50 70 100 100 100 100 100 100
3 FD FAN HEADER PRESSURE MMWC 412 402 412 413 362 423 365 400
4 FD AIR TEMP ⁰C 43.92 43.61 44.27 44.84 45.08 45.19 45.13 45.43
5 AIR FOR OIL FLOW/IGV NM3/HR/% 4547/24 4940/28 4838/28 4632/28 4505/30 5141/30 5341/35 5265/30
6 AIR FOR CO FLOW/IGV NM3/HR/% 33620/78 34095/80 36707/85 36612/85 40108/99 38633/88 40215/99 39965/95
7 AIR FOR DILUSION FLOW/IGV NM3/HR/% 3308/35 4681/26 4562/26 4491/26 4002/26 4672/26 5562/45 3789/23
8 TOTAL AIR FLOW NM3/HR 41384 43670 46020 45615 48518 48409 51200 49063
9 TAIL GAS INLET PRESSURE MMWC 238 208 213 206 215 200 234 200
10 TAIL GAS TEMP ⁰C 227 227 226 226 226 225 225 225
11 TAIL GAS FLOW NM3/HR 34970 36301 38650 39950 40581 40596 37803 42577 64750
12 COMBUSTER PRESSURE IN LOCAL GAUGE MMWC 100 100 120 120 140 140 140 140
13 COMBUSTER PRESSURE IN DCS MMWC 78/80 89/91 101/102 108/110 115/117 114/117 115/118 121/123
14 COMBUSTER TEMP ⁰C 1162/1165 1164/1166 1168/1169 1188/1190 1178/1179 1188/1191 1144/1148 1197/1198
15 EVAPORATOR INLET TEMP ⁰C 698 710 715 727 728 732 721 737
16 ECONOMISER INLET TEMP ⁰C 311 310 317 319 319 320 319 321
17 STACK INLET TEMP ⁰C 196 193 197 194 191 191 190 191
18 ECONOMISER INLET PRESSURE GAUGE MMWC 20 40 50 50 60 60 60 70
19 ECONOMISER OUTLET PRESSURE GAUGE MMWC -30 -30 -30 -30 -30 -30 -30 -30
20 ECONOMISER DP (DCS) MMWC 67 72 80 84 89 89 88 91
21 O2 ANALYSER READING % 3.55 3.26 3.32 2.71 3.02 2.81 3.97 2.71
22 AIRFLOW/TAILGAS FLOW 1.183 1.203 1.191 1.142 1.196 1.192 1.354 1.152
TOTAL FG FLOW NM3/HR 76354 79971 84670 85565 89099 89005 89003 91640
Boiler Efficiency % 92.82 90.93 90.14 91.83 92.08 91.87 89.65 89.66 89.24
Fuel GCV Kg/NM^3 825 860 875 875 875 875 950 900 725

ECONOMISER DP (DCS) 67 72 80 84 89 89 88 91
O2 ANALYSER READING 3.55 3.26 3.32 2.71 3.02 2.81 3.97 2.71
AIRFLOW/TAILGAS FLOW 1.18 1.20 1.19 1.14 1.20 1.19 1.35 1.15
TOTAL FG FLOW 76354 79971 84670 85565 89099 89005 89003 91640