0% found this document useful (0 votes)
1K views2 pages

Spec Sheet - Flare Stack Design

This document is a flare stack design specification sheet for a customer. It requests information about the equipment requirements, design parameters, pilot and ignition system for a flare stack. The equipment requirements section asks whether a utility or smokeless flare is needed and how it will be supported. The design parameters section requests information about flow rates, pressures, temperatures and regulations. It also requests a fuel and waste gas analysis. The pilot and ignition system section inquires about the type of pilot and power sources available on site.

Uploaded by

Scylar
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views2 pages

Spec Sheet - Flare Stack Design

This document is a flare stack design specification sheet for a customer. It requests information about the equipment requirements, design parameters, pilot and ignition system for a flare stack. The equipment requirements section asks whether a utility or smokeless flare is needed and how it will be supported. The design parameters section requests information about flow rates, pressures, temperatures and regulations. It also requests a fuel and waste gas analysis. The pilot and ignition system section inquires about the type of pilot and power sources available on site.

Uploaded by

Scylar
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Flare Stack

Design Specification Sheet

Attention: Customer:
Company Name: General Location:
Phone: Site Elevation:
Fax: Required By Date:
Email: Today’s Date:
Project Reference:

EQUIPMENT REQUIREMENTS
Utility Flare: 씲 No 씲 Yes 씮 씲 Intermittent 씲 Continuous
Smokeless Flare: 씲 No 씲 Yes 씮 씲 Air-Assist 씲 Steam-Assist 씲 Gas-Assist
________ % smokeless of total flow
Support: 씲 Self-Support 씲 Guyed 씲 Derrick
Knockout Drum: 씲 No 씲 Yes 씮 씲 Integral 씲 Separate
Flame Arrestor: 씲 No 씲 Yes 씮 씲 Deflagration 씲 Detonation
Velocity Seal: 씲 No 씲 Yes
Other Seal: 씲 Molecular 씲 Liquid

DESIGN PARAMETERS
If Flare Dimensions Known: Stack diameter: in. Stack height: ft.
If Flare Dimensions Unknown:
Design Flow Rate: (scfd) (scfh) (#/hr) (mol/hr)
Allowable Pressure Drop: PSIG
Pressure of Flare Gas: PSIG
Temperature of Flare Gas: (°F) (°C)
Allowable Radiation at Grade: (BTU/ft2/hr) (kW/m2)
Atmospheric Pressure: PSI (a)
Design Regulatory Authority: 씲 API 521 씲 ASME B31.1 씲 40CFR 60.13
Fuel Gas Analysis – provide details:
Waste Gas Analysis – provide details on a separate sheet or complete page two.

PILOT AND IGNITION SYSTEM


Continuous Pilot: 씲 No 씲 Yes 씮 씲 Natural Gas 씲 Propane
Add Flame Monitor/Auto-Relight: 씲 No 씲 Yes
Electronic (Arch- Light) Igniter: 씲 No 씲 Yes
Power: Solar Package (12 VDC) 씲 No 씲 Yes
Available Onsite: 씲 No 씲 Yes 씮 씲 120 VAC 씲 24 VDC 씲 Other
Other:

Page 1 of 2

TORNADO Technologies Inc. • Tel: 403-244-3333 • Fax: 403-245-1821 • www.tornadotech.com


Flare Stack
Waste Gas Analysis

Component Mole Percent Mole Fraction Pound Moles Per Hour

TOTALS:

Page 2 of 2

TORNADO Technologies Inc. • Tel: 403-244-3333 • Fax: 403-245-1821 • www.tornadotech.com

TORNADO Technologies Inc.   •    Tel: 403-244-3333   •    Fax: 403-245-1821   •   www.tornadotech.com
 
EQUIPMENT REQUIREMENT
TORNADO Technologies Inc.   •    Tel: 403-244-3333   •    Fax: 403-245-1821   •   www.tornadotech.com
Flare Stack
Waste Gas A

You might also like