Page 1 of 33
1. Features
2. Specification
3. Dimensions
5. Operation limits
6. Wiring diagram
7. Troubleshooting
8. Electronic function
Page 2 of 33
1.Features
1.1 Compact design
1.2 High efficiency and quiet operation
1.3 Unitary outdoor unit design
Page 3 of 33
2 Specification
2.1 Indoor unit
Model EL-KFR26G/TN2Y-A(B) EL-KFR36G/TN2Y-A(B)
Power supply Ph-V-Hz 1, 220-240V~,50Hz 1, 220-240V~,50Hz
Capacity Btu/h 9000 12000
Cooling Input W 36.5 51.5
Rated current A 0.17 0.24
Capacity Btu/h 10000 13000
Heating Input W 36.5 51.5
Rated current A 0.17 0.24
Model RPG13H RPG20D
Brand Welling WELLING
Indoor fan motor Input W 36.5 51.5
Capacitor uF 1.2 1.5
Speed(hi/mi/lo) r/min 1180/1080/1000 1250/1000/800
a.Number of rows 2 2
b.Tube pitch(a)x row pitch(b) mm 21x13.37 21×13.37
c.Fin spacing mm 1.3 1.3
Indoor coil d.Fin type (code) Hydrophilic aluminium Hydr0philiC aluminium
e.Tube outside dia.and type mm φ7 INNEGROOVE TUBE φ7, innergroove tube
f.Coil length x height x width mm 578X252X26.74 635×315×27.34
g.Number of circuits 2 2
Indoor air flow (Hi/Mi/Lo) m3/h 500/460/410 680/520/420
Indoor noise level (Hi/Mi/Lo) dB(A) 40.5/37.4/34.6 42.0/35.0/30.0
Dimension (W*H*D) mm 750×250×214(210) 815x282x217
Indoor unit Packing (W*H*D) mm 837X340X295 915x360x295
Net/Gross weight Kg 9/11 10.5kg/12kg
Design pressure(Hi/Lo) MPa 2.8/1.2 2.8/1.2
Liquid side/ Gas side mm Ф6.35/Ф9.53 Ф6.35/Ф12.7
Refrigerant piping Max. refrigerant pipe length m 10 10
Max. difference in level m 5 5
Connection wiring No No
Plug type 10A 16A
Thermostat type Electronic control Electronic control
Operation temp ℃ 17-30 17-30
Ambient temp ℃ 18-45 18-45
Application area m2 14-21 18-26
Page 4 of 33
2.2 Outdoor unit
Model M2OA-18HRN2 M2OA-21HRN2 M3OA-27HRN2 M3OA-30HRN2
Power supply Ph-V-Hz 1Ph,220-240V,50Hz 1Ph,220-240V,50Hz 1Ph,220-240V,50Hz 1Ph,220-240V,50Hz
Capacity Btu/h 9000X2 9000+12000 9000x3 9000x2+12000
Input W 1050X2 960+1100 1050X3 1800+1300
Rated
Cooling A 4.6X2 5+6 4.6X3 8.2+5.8
current
Btu/w
EER 8.6 8.8 8.5, 8.9, 8.5,
.h
Capacity Btu/h 10600X2 10000+13000 10600x3 13000+20000
Input W 1080X2 960+1140 1080X3 1750+1300
Rated
Heating A 4.8X2 5+6 4.8X3 8.2+5.8
current
Btu/w
COP 9.8 9.6 9.6 10.2/ 9.6
.h
Moisture Removal L/h 1.0x2 1.0+1.2 1.0x3 1.0x2 +1.2
Max. input consumption W 1330X2 1500+1900 1330X3 2200+1800
Max. current A 6.0X2 7.0+8.0 10.0 +8.2 10.0 +8.2
Starting current A 19.8 19.8+30 40+30 40+30
PG180X1C-4DZ3+P PG295X2CS-4KU1; PG295X2CS-4KU1;
Model PG180X1C-4DZ3X2
G225X2C-4FT PG225X2C-4FT PG225X2C-4FT
Type ROTARY Rotary Rotary Rotary
Brand GD TOSHIBA GD TOSHIBA GD Toshiba GD Toshiba
Capacity Btu/h 10800X2 10800+13650 18080; 13650 18080; 13650
Input W 1000X2 1000+1310 1760; 1310 1760; 1310
Rated
current(RLA A 4.4X2 4.4+6.1 8.5; 6.1 8.5; 6.1
Compre
)
ssor
Locked rotor
A 24X2 24+31 44, 31 44, 31
Amp(LRA)
Thermal UP3QE0591-T61+U
Internal Internal
protector UP3QE0591-T61X2 P3RE0591-T56
35uF/440VAC; 35uF/440VAC;
Capacitor uF 25X2 25+35
35uF/440VAC 35uF/440VAC
Refrigerant
ml 400X2 400+ 480 750; 480 750; 480
oil
Model YDK69-6 YDK69-6 YDK50-4G1 YDK50-4G1
Outdoor Brand WeiLing WeiLing Welling Welling
fan Input W 154 154 107Wx2 107Wx2
motor Capacitor uF 4 4 4uFx2 4uFx2
Speed r/min 900/670 900/670 1150 1150
Outdoor a.Number of rows 2 2 2 2
coil b.Tube pitch(a)x
mm 25.4x22 25.4x22
row pitch(b) 25.4X22 25.4X22
Page 5 of 33
c.Fin
mm 1.5 1.5
spacing 1.7 1.7
d.Fin type HYDROPHILIC HYDROPHILIC Hydrophilic Hydrophilic
(code) ALUMINIUM ALUMINIUM aluminium aluminium
e.Tube Ф9.53 Ф9.53
outside mm INNERGROOVE INNERGROOVE Ф9.53, Innergroove Ф9.53, Innergroove
dia.and type TUBE TUBE tube tube
f.Coil length
x height x mm 813X812X44 813X812X44
width 810X610X44 810X610X44
g.Number of 5(A System);4(B 5(A System);4(B
circuits 12 12 System) System)
Outdoor air flow m3/h 1900 2070 1450x2 1450x2
Outdoor noise level dB(A) 58 58 60 62
Dimension(
mm 860X830X330 860X830X330
W*H*D) 895X345X655 895X345X655
Outdoor Packing
mm 983X915X425 983X915X425
unit (W*H*D) 1050X470X720 1050X470X720
Net/Gross
Kg
weight 73/77 60/65 90/94 90/94
Refrigerant type g R407C/800X2 R407C/750+1000 R407C/ 1470+820 R407C/ 1470+820
Design pressure(Hi/Lo) MPa 2.8/1.2 2.8/1.2 2.6 2.6
Liquid side/ mm(in Ф6.35/Ф9.53; Ф Ф6.35/Ф9.53;Ф
Ф6.35/Ф9.53 Ф6.35/Ф9.53
Gas side ch) 6.35/Ф12.7 6.35/Ф12.7
Max.
Refriger
refrigerant m 10 10 10 (each unit) 10 (each unit)
ant
pipe length
piping
Max.
difference in m 5 5 5 (each unit) 5 (each unit)
level
Connection wiring No No No No
Plug type No NO No No
Thermostat type Electronic control Electronic control Electronic control Electronic control
Operation temp ℃ 17-30 17-30 17~30 17~30
18~45(cooling); 18~45(cooling); 18~45(cooling); 18~45(cooling);
Ambient temp ℃
-7~30(heating) -7~30(heating) -7~30(heating) -7~30(heating)
Application area m2 (14-21)x2 14-21; 18-26 (14-21)x3 (14-21)x2,16-24
Page 6 of 33
3.Dimensions
3.1 Indoor unit
Panel A
C
D B
Panel B
C
A B
A B C
EL-KFR26G/TN2Y-A(B) 214 750 250
EL-KFR36G/TN2Y-A(B) 217 815 282
Page 7 of 33
3.2 Outdoor unit
Outdoor unit 18K/21K
Page 8 of 33
4.Refrigeration cycle diagram
“1 drive 3 system” is made up of one “1 drive 1 system” and one “1 drive 2 system”.
PMV1
PMV2
SV2 SV1
2#
T2 1#
T1
Compressor
refrigeration distributor
1 drive 2 system
SV1:Primary four-way valve SV2: Secondary four-way valve PMV1,
PMV2:Electronic expansive valve
T1,T2:Indoor pipe temperature sensor
Condenser
Four-way valve
Evaporator
Compressor
1 drive 1 system
Notice:For 1 drives 2 system, there are two individual refrigerant circuit and two compressors, but for the 1drive 2
system in the 1 drive three system, there is only one refrigerant circuit and only one compressor.
Page 9 of 33
5.Operation limits
5.1Cooling operation
Outdoor unit air temp.℃ DB
45
COOLING
17
-7
0 17 32
Indoor air temp. ℃ DB
Note: 1.The chart is the result from the continuous operation under constant air temperature
Condition. However, excludes the initial pull-down stage.
2.The operation range below the dashed is the result added the low ambient kit.
5.2Heating operation
Indoor air temp. ℃ DB
30
25
20
15
10
-5 5 15 25
Outdoor unit air temp.℃ DB
Note : The chart is the result from the continuous operation under constant air
temperature conditions. However, excludes the initial pull-down stage.
Page 10 of 33
6.Wiring diagram
Indoor unit
Page 11 of 33
Outdoor unit
Page 12 of 33
For 1 drive 3 outdoor unit
Page 13 of 33
7.Troubleshooting
7.1 Indoor unit
7.1.1 Troubleshooting for indoor unit
Operation Timer
Failure phenomenon
lamp lamp
☆ X Indoor fan speed has been out of control for over 1 minute
On ☆ EEROM error
☆ ☆ No over-zero signal
r Extinguish
☆ Flash at 5Hz
Indoor fan speed has been out of control for over 1 minute ☆ X
Yes No
Yes No
No
Yes
Page 14 of 33
Failure phenomenon Operation lamp Timer lamp
After changing the main control board, check if the failure releases.
Yes
No Yes
The voltage of power supply is too low (less than 187V)? Indoor PCB is defective
Yes No
EEROM error On ☆
No over-zero signal ☆ ☆
This is alarm signal when the main chip can’t detect over-zero signal. When such failure occurs, the main
control board must have fault.
7.2 Outdoor unit
Failure phenomenon LED1 LED2 LED3
Stand by ☆ ☆ ☆
High temp. protect of condenser ☆ ☆
Temp. sensor in condenser 1 is open circuit or short circuit ☆
Temp. sensor in condenser 2 is open circuit or short circuit ☆
☆ Flash at 2Hz
Page 15 of 33
8 Electronic functions
8.1 Electric Control working environment
8.1.1 Input voltage: 145~260V
8.1.2 Input power frequency: 50Hz/60Hz
8.1.3 Ambient temperature: -7°C~+43°C
8.1.4 Indoor fan normal working amp is less than 1A,
8.1.5 Outdoors fan. Normal working amp is less than 1A
8.1.6 Four-way valve normal working amp is less than 0.5A.
8.1.7 Swing motor: DC12V.
Page 16 of 33
8.5 Protection
8.5.1 The compressor functions protection with a delay of three minutes.
8.5.2 High temp. protection of condenser.
8.5.3 Sensor protection at open circuit and breaking disconnection
8.5.4 Temperature Fuse break protection
8.5.5 Fan Speed is out of control. When Indoor Fan Speed is too high(higher than High
Fan+300RPM)or too low(lower than 400RPM), the entire unit stops and LED displays
failure information and can’t returns to normal operation automatically.
Page 18 of 33
8.9.5 Auto wind under heating mode
Condition Indoor fan speed
T=Indoor Temp.-Setting Temp.
Room temp. up T<2℃ High
T>2℃ Mid.
Room temp. down T> 0℃ Mid.
T<0℃ High
Compressor
ON
ON
4-way Valve
OFF
ON
Outdoor Fan
OFF
Page 19 of 33
8.11 Automatic operation mode
8.11.1 The air conditioner automatically selects one of the following operation modes: cooling,
heating or ventilation according to the difference between room temp. (TA) and set temp.
(TS).
TA—TS Operation mode
TA—TS>2℃ Cooling
-1℃≤TA—TS≤+2℃ Fan-only
TA—TS<-1℃ Heating (Fan-only for cooling only type)
Page 20 of 33
8.16 Outdoor fan motor
T4: Outdoor temp.
T4 Outdoor fan motor
Cooling mode T4>27℃ High speed
T4<25℃ Low speed
Heating mode T4>13℃ Low speed
T4<11℃ High speed
Page 21 of 33
9 Exploded view parts
9.1 INDOOR UNIT
Exploded View Parts for Model: EL-KFR26G/TN2Y-A(B) 220-240V~ 50Hz :Indoor Unit
No. Part Name Quantity BOM code No. Part Name Quantity BOM code
1 Front panel (type B) 1 2113039184 19 Evaporator temp sensor 1 2230130056
2 Front panel (type A) 1 2113039179 20 Evaporator 1 2153159019
Air cleaner 1 2113010212 21 Bearing holder 1 2273010201
3
Air cleaner holder 1 2113010217 22 Chassis 1 2113031343
4 Air filter 2 2113039175 23 Installation plate 1 2123039002
5 Screw cap 3 2113039178 24 Back cover for chassis 1 2113010216
Window cover for Clamp for connecting
6 repairing 1 2113039183 25 pipe 1 2113010204
Panel frame (type A) 1 2113039176 26 Fan motor 1 2240030005
7
Panel frame (type B) 1 2113039197 27 Cross flow fan, assy 1 2113010219
8 Display board assy 1 2333039081 28 Motor cover 1 2113010203
Holder for display Holder for remote
9 board 1 2113039199 29 controller 1 2113139022
10 Air out frame assy 1 2113039177 30 Remote Controller 1 2335509179
11 Horizontal louver 1 2113039027 31 Transformer 1 2230090029
12 Louver holder I 1 2113031305 32 Cover for E-parts box 1 2113019182
13 Air out frame 1 2113039028 33 Wire joint, 5p 1 2243019081
14 Louver holder II 1 2113031306 34 E-Parts box 1 2113159004
15 Vertical louver 10 2113031365 35 Main control board 1 2135029046
16 Louver motor 1 2240020006 36 Copper nut, TLM-A01 1 2160032000
17 Drain hose 1 2113000001 37 Copper nut, TLM-B02 1 2160032001
18 Indoor temp sensor 1 2243069052
Page 22 of 33
Exploded View Parts for Model: EL-KFR36G/TN2Y-A(B) 220-240V~ 50Hz :Indoor
Unit
No. Part Name Quantity BOM code No. Part Name Quantity BOM code
1 Front panel (type B) 1 2113159018 19 Evaporator temp sensor 1 2243069051
2 Front panel (type A) 1 2113159016 20 Evaporator 1 2153159020
Air cleaner 1 2113010212 21 Bearing holder 1 2273010201
3
Air cleaner holder 1 2113010217 22 Chassis 1 2113132342
4 Air filter 2 2113132312 23 Installation plate 1 2123050005
Clamp for connecting
5 Screw cap 3 2113132323 24 pipe 1 2113010204
Window cover for
6 repairing 1 2113159005 25 Fan motor 1 2240030213
7 Panel frame 1 2113159015 26 Cross flow fan, assy 1 2110020008
8 Display board assy 1 2333159010 27 Motor cover 1 2113132314
Holder for display Holder for remote
9 board 1 2113159030 28 controller 1 2113139022
10 Air out frame assy 1 2113159007 29 Remote Controller 1 2335509179
11 Horizontal louver 1 2113159031 30 Transformer 1 2230090029
12 Louver holder I 1 2113051554 31 Cover for E-parts box 1 2113139036
13 Air out frame 1 2113159032 32 Wire joint, 5p 1 2230145064
14 Louver holder II 1 2113051555 33 E-Parts box 1 2113139141
15 Vertical louver 11 2113159033 34 Main control board 1 2135029047
16 Louver motor 1 2240020006 35 Copper nut, TLM-A01 1 2160032000
17 Drain hose 1 2110102007 36 Copper nut, TLM-C03 1 2160032002
18 Indoor temp sensor 1 2243069052
Page 23 of 33
9.2 Universal Outdoor Unit
9 15
8
12
5 14
4 13
16
6
3 17
2 7
10 11 18
1
19
25 26 27
20 23
45 28 29
21 24
30
22
31
32
36
44 39 33
43
42 41
37 34
40 38 35
Page 24 of 33
18 Installation plate for valves 1 10718111817 2125024209
19 Compressor B 1 10718121817 2140061730
20 Compressor A 1 10718121817 2140061730
21 Chassis 1 53818121812 2125024231
22 4-Ways valve for unit A 1 10409121808 2160069006
23 4-Ways valve for unit B 1 10409121808 2160069006
24 Compressor capacitor for unit A 1 10309121820 2240100402
25 Compressor capacitor for unit B 1 10309121820 2240100402
26 Capacitor clamp 2 10109121822 2120010005
27 Main control board 1 10718121810 2135029600
28 Transformer 1 10718121808 2230090015
29 Installation board for E-parts 1 10718121820 2125024222
30 Fan motor capacitor 1 10718121804 2240110404
31 Wire joint, 4p 1 10718121807 2230145003
32 Wire joint for multiplexer 1 10718121806 2230145017
33 Washer for wire joint 1 10112121817 2113500004
34 Clamp for wiring 1 10112121816 2121990001
35 Wire joint, 6p 1 10718121805 2230145030
36 Liquid pipe valve for unit A 1 10721121803 2160071515
37 Gas pipe valve for unit A 1 10718121822 2160071007
38 Liquid pipe valve for unit B 1 10721121803 2160071515
39 Gas pipe valve for unit B 1 10718121822 2160071007
40 Water collector 1 10718111816 2113560000
41 Gas valve assy, unit A 1 10718121813 2165029070
42 Gas valve assy, unit B 1 10718121815 2165029071
43 Liquid valve assy, unit A 1 10718121812 2165029072
44 Liquid valve assy, unit B 1 10718121814 2165029075
45 Strenghten board for motor holder I 1 53818121808 2125024228
Page 25 of 33
M2OA-21HRN2 220~240V,50Hz: Outdoor Unit
9 15
8
12
5 14
4 13
16
6
3 17
2 7
10 11 18
1
19
25 26 27
20 23
46 28 29
21 24
30
22
31
41 32
36
44
45 39 33
43
44
42
43 41
42
37 34
40 38 35
Page 26 of 33
19 Compressor B 1 10718121817 2140061730
20 Compressor A 1 10721121807 2140061562
21 Chassis 1 53818121813 2125024230
22 4-Ways valve for unit A 1 50118121804 2160060051
23 4-Ways valve for unit B 1 10409121808 2160069006
24 Compressor capacitor for unit A 1 30324313020 2240100602
25 Compressor capacitor for unit B 1 10309121820 2240100402
26 Capacitor clamp 1 10109121822 2120010005
27 Main control board 1 10718121810 2135029600
28 Transformer 1 10718121808 2230090015
29 Installation board for E-parts 1 10718121820 2125024222
30 Fan motor capacitor 1 10718121804 2240110404
31 Wire joint, 4p 1 10718121807 2230145003
32 Wire joint for multiplexer 1 10718121806 2230145017
33 Washer for wire joint 1 10112121817 2113500004
34 Clamp for wiring 1 10112121816 2121990001
35 Wire joint, 6p 1 10718121805 2230145030
36 Liquid pipe valve for unit A 1 10721121803 2160071515
37 Gas pipe valve for unit A 1 10721121810 2160071008
38 Liquid pipe valve for unit B 1 10721121803 2160071515
39 Gas pipe valve for unit B 1 10718121822 2160071007
40 Water collector 1 10718111816 2113560000
41 Capacitor clamp 1 31116313015 2120010009
42 Gas valve assy, unit A 1 10721121804 2165029090
43 Gas valve assy, unit B 1 10718121815 2165029071
44 Liquid valve assy, unit A 1 10721121802 2165029091
45 Liquid valve assy, unit B 1 10721121805 2165029096
46 Strenghten board for motor holder I 1 53818121808 2125024228
Page 27 of 33
M3OA-27HRN2 220-240V 50Hz : Outdoor Unit
11 12
10
13
9
14
15
6 8
16
7
17
5
25 18
4
19
20
3
21
2
26 35 22
34
33 23
27 36
1 28
37 24
29
30 38
47 39
56
55 46 43 40
45
31
32 53
44 41
42 54
52 51 50 49 48
11 12
10
13
9
14
15
6 8
16
7
17
5
25 18
4
19
20
3
21
2
26 35 22
34
33 23
27 36
1 28
37 24
29
30 38
56 47 39
55 46 43
45 40
31 53
57 32 41
44
42 54
52 51 50 49 48
Page 32 of 33
10. Characteristic of temp. sensor
Temp.℃ Resistance KΩ Temp.℃ Resistance KΩ Temp.℃ Resistance KΩ
-4 44 23 10.9731 50 3.451
-2 39.8239 25 10 52 3.1918
Page 33 of 33