You are on page 1of 3

Document Cover Sheet

MET WELD
5727 OSTRANDER ROAD, ALTAMONT, NY 12009, USA

Project Name GE AERO – NYPA Brentwood

Hydrogen Metering Skid – MDL


Component
#14 – General Arrangement

Specification LM6000PC

Purchase Order
525238193
Number

Document Title 56821026

Document Number MDL #14 General Arrangement

Revision Number B

Document Date July – 28 – 2021


8 7 6 5 4 3 2 1
DESIGN PRESSURE: 900 PSIG PLANT INSTALLER INTERFACE TABLE
DESIGN TEMP: 300 F INTERFACE CONNECTION SIZE CONNECTION TYPE DESCRIPTION MATERIAL
NOTES: MDMT: -20 F PC1 3.0 [76.2] CL 600 RF FG INLET A 182 T 316
3/4"-10 THREADED
MOP H2: 775 PSIG
JACKING HOLE PC2 3.0 [76.2] CL 600 RF FG OUTLET A 182 T 316
1. DIMENSIONS ARE IN INCHES. DIMENSIONS IN BRACKETS [ ] ARE IN MILLIMETERS. EQUIVALENTS FOR MOP GAS: 715 PSIG
REFERENCE ONLY. PC3 2.0 [50.8] CL 600 RF H2 INLET A 182 T 316
PC4 2-1/2 [63.5] CL 150 RF VENT STACK A 182 T 316
1.00 1.0 [25.4]
2. ALL FLANGE CONNECTION SIZES SHOWN ARE NOMINAL PIPE SIZE ( NPS ) PER UNITED STATES ANSI PC5 CL 150 RF INSTRUMENT AIR A 182A T 304
D [ 25.4] D

[228.6]
STANDARD. NO METRIC EQUIVALENTS EXIST AND HENCE ARE NOT SHOWN. FLANGE BOLT HOLES SHALL PURGE 0.50 [12.7] FNPT N2 PURGE T 316

[25.4]
9.00
STRADDLE AND BE SYMMETRICAL ABOUT THE CENTERLINE. 0.125 [3.2]

1.00
ANALYZER SAMPLE FNPT SAMPLE T316

[139.7]
ANALYZER VENT 0.75 [19.05] FNPT VENT T 316
3. THE TOTAL RESULTANT FORCE AND TOTAL RESULTANT MOMENT IMPOSED ON ANY CONNECTION MUST NOT

5.50
EXCEED THE FOLLOWING:
ENGLISH UNITS
F=(300) x (D)
M=(600) x (D)
WHERE F = RESULTANT FORCE IN POUNDS 1.00
[25.4]

[127.0]
M = RESULTANT MOMENT IN FT-LBS WEEPHOLE

5.00
D = PIPE SIZE OF THE CONNECTION (N.P.S.) IN INCHES UP TO 8 INCHES IN DIAMETER. BELOW (TYP 2)

[25.4]
2.50
PER CGA G-5.5

1.00
[63.5]
4. MODULE TO BE MOUNTED ON PLANT DESIGNER AND OR PLANT INSTALLER FOUNDATION AND ANCHORED IN
(4) LOCATIONS. 4.50
[114.3]

[88.9]
3.50
5. IT IS REQUIRED TO USE A SPREADER BAR TO LIFT THIS SKID. SPREADER BAR SHALL BE APPROXIMATELY THE
6.75
THE WIDTH OF SKID. THE MAXIMUM ANGLE AT EACH CABLE OR SLING SHALL BE 22.5 DEG FROM VERTICAL, 45
[171.5]
DEG MAX COMBINED.
9.00 6.00
6. CARBON STEEL STRUCTURE [228.6] [152.4]

SURFACE PREP PER SPECIFICATION SP 10. DETAIL A DETAIL B DETAIL C


SURFACE OF SKID & COMPONENTS TO BE COATED PER MFG INSTRUCTIONS AS FOLLOWS PER MWI WI M0021: SCALE 1 / 4 SCALE 1 / 4 SCALE 1 / 4
BASE: INTERZINC 52, GREEN GRAY 50 MIC,

BASE INTERMEDIATE: INTERGARD 475HS, 100 MIC


C SAMPLE AND VENT TUBING BY OTHERS. C
BASE TOP: INTERTHANE 990HS, 50 MIL, LIGHT GRAY (RAL 7035) LIMIT STOPS TO BE INSTALLED
SHOWN FOR REFERENCE ONLY. B
TO PREVENT COMPONENT
DECK PLATE TO RECEIVE ANTI SKID TREATMENT. DAMAGE FROM OVER SWING

[1828.8])

[1879.6])
7. MATING FLANGES AND HARDWARE PROVIDED BY OTHERS. B
B B

(72.00
(74.00
B

[2281.9]

[2847.1]

[3715.7]
8. THE FOLLOWING TOLERANCES APPLY UNLESS OTHERWISE NOTED IN THE DRAWING:

[127.9]

112.09

146.29
89.84
- LARGE BORE ( > 2 INCH ) PIPE FLANGE LOCATIONS: +/- 0.5 INCH [ 12.7 MM ] +/- 0.30 DEGREES

[609.6]

5.03
24.00
- SMALL BORE ( < = 2 INCH PIPE CONNECTION LOCATIONS: +/- 6.00 INCH [ 152.4 MM ] +/- 0.30 DEGREES
- ELECTRICAL JUNCTION BOX LOCATIONS AND CONDUIT PENETRATIONS: +/- 8.00 INCH [ 5.8 MM ]
- LIFTING LUG / TRUNNION LOCATIONS: +/- 1.00 INCH [ 25.4 MM ]
78.00
215.94 [1981.2]
[5484.9] FILTER
77.25 HMTB COVER
[1962.2] SWING ESH1 67.16
120.00 [1706.0]
[3048.0] 60.00
PC4 [1524.0]
MAX SHIPPING PC2
HEIGHT ADJUSTABLE SUPPORT FOR HOBRE
SAMPLE AND VENT TUBING
B
(101.69
[2582.9]) 39.84
97.63 ANALYZER [1011.9] 27.69
( [2479.8] ) VENT C.G. [703.3]
B
B (89.75
[2279.7])
B

TRANSMITTERS TO ANALYZER SAMPLING


BE VISIBLE FROM 15.00
PROBE (BEYOND) 15.00 [381.0]
SKID EDGE. (TYP ALL)
[381.0]
PC1
PC1 PC3
67.64 8.00 PC4
[1717.9] [203.2] SAMPLE VENT
HMTB PC5
57.38
A
[1457.5] .00
PC3 [.0] 2.38
[60.3]

ANALYZER
[1654.9]

SAMPLE

[2129.2]

1/2" FNPT
65.15
33.38

[907.5]

[3962.4]
[3467.1]

[4114.8]
83.83
35.73

PURGE

156.00
136.50

162.00
[847.9]

INLET
C.G.
[.0]

PC4
.00

PC1
PC2 NO TRAPS
19.82 PERMITTED IN
IMPULSE TUBING B A ECN 21-036 7/19/21 JJP AJG
[503.5]
C.G. B ECN 21-043 7/28/21 JJP AJG
UNIT DRY WEIGHT 8500.000 lbmass
REV ECN NUMBER DATE REV BY APR
16.00 DRAWN TITLE
[406.4] UNLESS OTHERWISE
K SHAW 6/7/2021
PC5
12.88
SPECIFIED DIM ARE IN
INCHES
FRACTIONS 1/16
CHECKED NYPA GREEN H2 PROJECT
A GORRELL 6/7/2021
A [327.2] TOL ON ANGLE 0 60' LM6000PC A
C B .XX .06 .XXX .012
APPROVED EDL NUMBER
INTERPRET DIM AND TOL 66821071
PER ASME Y14.5M - 2009 HYDROGEN METERING SKID
DO NOT SCALE DRAWING SCALE AS NOTED
.00
[.0]
THIRD ANGLE PROJECTION PROJECT NO. 5727 Ostrander Rd SIZE DWG NO REV
[3530.6]

FORKLIFT SLOT BLOWOUT DRAIN


[584.2]

Altamont NY 12009
139.00

21141 D 56821026 B
23.00

(TYPICAL)
518.765.8304 1 OF 2
8 7 6 5 4 3 2 1

THIS DRAWING IS PROPERTY OWNED BY METWELD INTERNATIONAL LLC. THIS DRAWING IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, OR USED FOR FURNISHING INFORMATION TO OTHERS OR FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION OF METWELD INTERNATIONAL LLC. METWELD INTERNATIONAL LLC DISCLAIM LIABILITY FOR ALL LOSSES OR DAMAGES RESULTING
FROM ANY INFORMATION PROVIDED ON THIS DRAWING, WHICH RESULTED FROM INFORMATION PROVIDED BY THE CUSTOMER OR OTHER CONTRIBUTORS. IN THE EVENT OF A CONFLICT BETWEEN THE CONTRACT AND THIS DRAWING THE PROVISIONS OF THE CONTRACT WILL GOVERN.
8 7 6 5 4 3 2 1

NOTES:

B 1. Site information taken from specification TS00001745, which exceeds the loading conditions for this site location. THerefore this analysis complies
with NYS building code.
2. Load safety factors are not included in the foundation loads identified herein. The foundation designer is responsible for the selection of the FOUNDATION LOAD CALCS (UNITS IN LBF)
D appropriate load safety factors for the foundation design. D
3. For foundation design, forces are assumed to be uniformly distributed over the projected area of the foundation / base plate perpendicular to the VERTICAL VERTICAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL
ANCHOR POINT DEAD LOAD LIVE LOAD SNOW LOAD
applied force, unless otherwise indicated. SEISMIC SEISMIC SEISMIC SEISMIC SEISMIC SEISMIC
4. The selection of the specific load combinations for the design of the foundation is the responsibility of the foundation designer. X DIRECTION X-DIRECTION Y-DIRECTION Y-DIRECTION
5. For Wind load calculations, skid is treated as open roof and open frame (lattice) structure. (-Z) (-Z) (Z) (-Z) (X) (Z) (Y) (Z) (-Z)
6. The following anchors were used for calculations: P1 2197 2754 931 931 1580 409 1580 849 1211
P2 2197 2754 931 931 1580 409 1580 849 1211
Cast in Place J-bolts, minimum 8" embedment length, A193 B7 material
P3 2178 2731 931 931 1580 409 1580 849 1211
DEFINITIONS: P4 2178 2731 931 931 1580 409 1580 849 1211

1. Dead Load - The load at each anchor point due to the weight of the equipment. This includes water weight as well.
2. Live Load - The load at each anchor point resulting from an assumed uniform load, which accounts for transitory loads such as construction workers, portable
equipment, maintenance and tools on the equipment.
3. Seismic - The equivalent static loads resulting from seismic events.
4. Wind - The equivalent static loads at each anchor point resulting from wind pressure loads on exposed surfaces of the equipment.

FOUNDATION LOAD TABLE - WIND LOADS (UNITS IN LBF)

ANCHOR POINT +Y DIRECTION +Y DIRECTION -Y DIRECTION -Y DIRECTION +X DIRECTION +X DIRECTION -X DIRECTION -X DIRECTION

(Y) (Z) (Y) (Z) (X) (Z) (X) (Z)


P1 -1183 2657 1183 109 -390 1181 390 1585
P2 -1183 2657 1183 109 -390 1585 390 1181
SITE CONDITIONS FOR LOAD CALCULATIONS P3 -1183 109 1183 2657 -390 1181 390 1585
P4 -1183 109 1183 2657 -390 1585 390 1181
LOCATION: BRENTWOOD, NY
C C
BUILDING CODE: IBC 2015 / ASCE-10

SEISMIC:
Site Class = D
Mapped Spectral Response Acceleration Parameters, Ss =1.8g; S1 = 0.7g
Site Coefficients, Fa = 1.6, Fv = 2.4 (As applicable to Site Class D)
Occupancy Category III
Seismic Importance Factor for Risk Category III, IE = 1.25
Seismic Design Category: E

WIND:
Basic Design Wind Speed, V = 150 MPH
Risk Category = III
Exposure = C 155.00
Importance Factor, Iw = 1.25 [3937.0]
Topographic Factor Kzt = 1.0 P1 P2
Applicable Internal Pressure Coefficient, Cpi = 0 psf. Not Enclosed

SNOW:
Ground Snow Load, pf = 60 psf

LIVE LOAD:
Occupancy = Light Manufacturing
Uniform Load = 125 psf
[1930.4]

B B
76.00

P3 P4
Y-DIRECTION

Z-DIRECTION
SECTION D-D
IS UP SCALE 1 / 20
X-DIRECTION

A ECN 21-036 7/19/21 JJP AJG


B ECN 21-043 7/28/21 JJP AJG
UNIT DRY WEIGHT N/A
REV ECN NUMBER DATE REV BY APR
UNLESS OTHERWISE DRAWN TITLE
K SHAW 6/7/2021
SPECIFIED DIM ARE IN
INCHES
FRACTIONS 1/16
CHECKED NYPA GREEN H2 PROJECT
A GORRELL 6/7/2021
A TOL ON ANGLE
.XX .06 .XXX
0 60'
.012
APPROVED EDL NUMBER LM6000PC A
INTERPRET DIM AND TOL 66821071
PER ASME Y14.5M - 2009 HYDROGEN METERING SKID
DO NOT SCALE DRAWING SCALE AS NOTED
THIRD ANGLE PROJECTION PROJECT NO. 5727 Ostrander Rd SIZE DWG NO REV

21141 Altamont NY 12009 D 56821026 B


518.765.8304 2 OF 2
8 7 6 5 4 3 2 1

THIS DRAWING IS PROPERTY OWNED BY METWELD INTERNATIONAL LLC. THIS DRAWING IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, OR USED FOR FURNISHING INFORMATION TO OTHERS OR FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION OF METWELD INTERNATIONAL LLC. METWELD INTERNATIONAL LLC DISCLAIM LIABILITY FOR ALL LOSSES OR DAMAGES RESULTING