MET WELD
5727 OSTRANDER ROAD, ALTAMONT, NY 12009, USA
Specification LM6000PC
Purchase Order
525238193
Number
Revision Number B
[228.6]
STANDARD. NO METRIC EQUIVALENTS EXIST AND HENCE ARE NOT SHOWN. FLANGE BOLT HOLES SHALL PURGE 0.50 [12.7] FNPT N2 PURGE T 316
[25.4]
9.00
STRADDLE AND BE SYMMETRICAL ABOUT THE CENTERLINE. 0.125 [3.2]
1.00
ANALYZER SAMPLE FNPT SAMPLE T316
[139.7]
ANALYZER VENT 0.75 [19.05] FNPT VENT T 316
3. THE TOTAL RESULTANT FORCE AND TOTAL RESULTANT MOMENT IMPOSED ON ANY CONNECTION MUST NOT
5.50
EXCEED THE FOLLOWING:
ENGLISH UNITS
F=(300) x (D)
M=(600) x (D)
WHERE F = RESULTANT FORCE IN POUNDS 1.00
[25.4]
[127.0]
M = RESULTANT MOMENT IN FT-LBS WEEPHOLE
5.00
D = PIPE SIZE OF THE CONNECTION (N.P.S.) IN INCHES UP TO 8 INCHES IN DIAMETER. BELOW (TYP 2)
[25.4]
2.50
PER CGA G-5.5
1.00
[63.5]
4. MODULE TO BE MOUNTED ON PLANT DESIGNER AND OR PLANT INSTALLER FOUNDATION AND ANCHORED IN
(4) LOCATIONS. 4.50
[114.3]
[88.9]
3.50
5. IT IS REQUIRED TO USE A SPREADER BAR TO LIFT THIS SKID. SPREADER BAR SHALL BE APPROXIMATELY THE
6.75
THE WIDTH OF SKID. THE MAXIMUM ANGLE AT EACH CABLE OR SLING SHALL BE 22.5 DEG FROM VERTICAL, 45
[171.5]
DEG MAX COMBINED.
9.00 6.00
6. CARBON STEEL STRUCTURE [228.6] [152.4]
[1828.8])
[1879.6])
7. MATING FLANGES AND HARDWARE PROVIDED BY OTHERS. B
B B
(72.00
(74.00
B
[2281.9]
[2847.1]
[3715.7]
8. THE FOLLOWING TOLERANCES APPLY UNLESS OTHERWISE NOTED IN THE DRAWING:
[127.9]
112.09
146.29
89.84
- LARGE BORE ( > 2 INCH ) PIPE FLANGE LOCATIONS: +/- 0.5 INCH [ 12.7 MM ] +/- 0.30 DEGREES
[609.6]
5.03
24.00
- SMALL BORE ( < = 2 INCH PIPE CONNECTION LOCATIONS: +/- 6.00 INCH [ 152.4 MM ] +/- 0.30 DEGREES
- ELECTRICAL JUNCTION BOX LOCATIONS AND CONDUIT PENETRATIONS: +/- 8.00 INCH [ 5.8 MM ]
- LIFTING LUG / TRUNNION LOCATIONS: +/- 1.00 INCH [ 25.4 MM ]
78.00
215.94 [1981.2]
[5484.9] FILTER
77.25 HMTB COVER
[1962.2] SWING ESH1 67.16
120.00 [1706.0]
[3048.0] 60.00
PC4 [1524.0]
MAX SHIPPING PC2
HEIGHT ADJUSTABLE SUPPORT FOR HOBRE
SAMPLE AND VENT TUBING
B
(101.69
[2582.9]) 39.84
97.63 ANALYZER [1011.9] 27.69
( [2479.8] ) VENT C.G. [703.3]
B
B (89.75
[2279.7])
B
ANALYZER
[1654.9]
SAMPLE
[2129.2]
1/2" FNPT
65.15
33.38
[907.5]
[3962.4]
[3467.1]
[4114.8]
83.83
35.73
PURGE
156.00
136.50
162.00
[847.9]
INLET
C.G.
[.0]
PC4
.00
PC1
PC2 NO TRAPS
19.82 PERMITTED IN
IMPULSE TUBING B A ECN 21-036 7/19/21 JJP AJG
[503.5]
C.G. B ECN 21-043 7/28/21 JJP AJG
UNIT DRY WEIGHT 8500.000 lbmass
REV ECN NUMBER DATE REV BY APR
16.00 DRAWN TITLE
[406.4] UNLESS OTHERWISE
K SHAW 6/7/2021
PC5
12.88
SPECIFIED DIM ARE IN
INCHES
FRACTIONS 1/16
CHECKED NYPA GREEN H2 PROJECT
A GORRELL 6/7/2021
A [327.2] TOL ON ANGLE 0 60' LM6000PC A
C B .XX .06 .XXX .012
APPROVED EDL NUMBER
INTERPRET DIM AND TOL 66821071
PER ASME Y14.5M - 2009 HYDROGEN METERING SKID
DO NOT SCALE DRAWING SCALE AS NOTED
.00
[.0]
THIRD ANGLE PROJECTION PROJECT NO. 5727 Ostrander Rd SIZE DWG NO REV
[3530.6]
Altamont NY 12009
139.00
21141 D 56821026 B
23.00
(TYPICAL)
518.765.8304 1 OF 2
8 7 6 5 4 3 2 1
THIS DRAWING IS PROPERTY OWNED BY METWELD INTERNATIONAL LLC. THIS DRAWING IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, OR USED FOR FURNISHING INFORMATION TO OTHERS OR FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION OF METWELD INTERNATIONAL LLC. METWELD INTERNATIONAL LLC DISCLAIM LIABILITY FOR ALL LOSSES OR DAMAGES RESULTING
FROM ANY INFORMATION PROVIDED ON THIS DRAWING, WHICH RESULTED FROM INFORMATION PROVIDED BY THE CUSTOMER OR OTHER CONTRIBUTORS. IN THE EVENT OF A CONFLICT BETWEEN THE CONTRACT AND THIS DRAWING THE PROVISIONS OF THE CONTRACT WILL GOVERN.
8 7 6 5 4 3 2 1
NOTES:
B 1. Site information taken from specification TS00001745, which exceeds the loading conditions for this site location. THerefore this analysis complies
with NYS building code.
2. Load safety factors are not included in the foundation loads identified herein. The foundation designer is responsible for the selection of the FOUNDATION LOAD CALCS (UNITS IN LBF)
D appropriate load safety factors for the foundation design. D
3. For foundation design, forces are assumed to be uniformly distributed over the projected area of the foundation / base plate perpendicular to the VERTICAL VERTICAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL
ANCHOR POINT DEAD LOAD LIVE LOAD SNOW LOAD
applied force, unless otherwise indicated. SEISMIC SEISMIC SEISMIC SEISMIC SEISMIC SEISMIC
4. The selection of the specific load combinations for the design of the foundation is the responsibility of the foundation designer. X DIRECTION X-DIRECTION Y-DIRECTION Y-DIRECTION
5. For Wind load calculations, skid is treated as open roof and open frame (lattice) structure. (-Z) (-Z) (Z) (-Z) (X) (Z) (Y) (Z) (-Z)
6. The following anchors were used for calculations: P1 2197 2754 931 931 1580 409 1580 849 1211
P2 2197 2754 931 931 1580 409 1580 849 1211
Cast in Place J-bolts, minimum 8" embedment length, A193 B7 material
P3 2178 2731 931 931 1580 409 1580 849 1211
DEFINITIONS: P4 2178 2731 931 931 1580 409 1580 849 1211
1. Dead Load - The load at each anchor point due to the weight of the equipment. This includes water weight as well.
2. Live Load - The load at each anchor point resulting from an assumed uniform load, which accounts for transitory loads such as construction workers, portable
equipment, maintenance and tools on the equipment.
3. Seismic - The equivalent static loads resulting from seismic events.
4. Wind - The equivalent static loads at each anchor point resulting from wind pressure loads on exposed surfaces of the equipment.
ANCHOR POINT +Y DIRECTION +Y DIRECTION -Y DIRECTION -Y DIRECTION +X DIRECTION +X DIRECTION -X DIRECTION -X DIRECTION
SEISMIC:
Site Class = D
Mapped Spectral Response Acceleration Parameters, Ss =1.8g; S1 = 0.7g
Site Coefficients, Fa = 1.6, Fv = 2.4 (As applicable to Site Class D)
Occupancy Category III
Seismic Importance Factor for Risk Category III, IE = 1.25
Seismic Design Category: E
WIND:
Basic Design Wind Speed, V = 150 MPH
Risk Category = III
Exposure = C 155.00
Importance Factor, Iw = 1.25 [3937.0]
Topographic Factor Kzt = 1.0 P1 P2
Applicable Internal Pressure Coefficient, Cpi = 0 psf. Not Enclosed
SNOW:
Ground Snow Load, pf = 60 psf
LIVE LOAD:
Occupancy = Light Manufacturing
Uniform Load = 125 psf
[1930.4]
B B
76.00
P3 P4
Y-DIRECTION
Z-DIRECTION
SECTION D-D
IS UP SCALE 1 / 20
X-DIRECTION
THIS DRAWING IS PROPERTY OWNED BY METWELD INTERNATIONAL LLC. THIS DRAWING IS NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, OR USED FOR FURNISHING INFORMATION TO OTHERS OR FOR ANY PURPOSE WITHOUT WRITTEN PERMISSION OF METWELD INTERNATIONAL LLC. METWELD INTERNATIONAL LLC DISCLAIM LIABILITY FOR ALL LOSSES OR DAMAGES RESULTING
FROM ANY INFORMATION PROVIDED ON THIS DRAWING, WHICH RESULTED FROM INFORMATION PROVIDED BY THE CUSTOMER OR OTHER CONTRIBUTORS. IN THE EVENT OF A CONFLICT BETWEEN THE CONTRACT AND THIS DRAWING THE PROVISIONS OF THE CONTRACT WILL GOVERN.