Scale parameters and functions

6.3 DR 3 calibration parameters

6.3.16 Standstill range


Standstill monitoring checks whether the scales are correctly balanced. Scale standstill is
registered if the weight changes by less than a specified fluctuation in d (standstill value)
over a specified time (standstill time). Standstill monitoring is used in static scale mode
(commands: zeroing, taring). The diagram below illustrates how standstill monitoring works.

Image 6-1 Standstill monitoring

6.3.17 Standstill time


Standstill monitoring checks whether the scales are correctly balanced. Scale standstill is
registered if the weight changes by less than a specified fluctuation in d (standstill value)
over a specified time (standstill time). Standstill monitoring is used in static scale mode (with
the following commands: zeroing, taring).

6.3.18 Standstill waiting time


Standstill waiting time is a maximum waiting time for standstill upon the execution of a
command which depends on standstill (taring, zeroing, registering). A technology message is
generated if the command cannot be executed during the standstill waiting time because
there is no standstill.