You are on page 1of 3

HOT WATER HEATER CAPACITY CALCULATON & PIPE SIZING

Project No. 3481 Date 08/05/2023


Project Name SERENIA LIVING -TOWER-1,2,3 & 4 Prepared By RR
Checked By DW
Issue IFC

Building Type: Apartment/House


Demand Factor 30%
Storage Capacity Factor 125%

POWDER ROOM (Typical)


Fixture details Heater sizing Pipe sizing
Total design
Total litres per hour Total Loading
# Fixture Type Qty. of Fixtures Litres of Water per hour/per fixture Loading units discharge Pipe sizes Remarks
per fixture units
(gpm)
1 Basin,private Lavatory 1 7.60 8 2 2 0.03 15
2 Basin,public lavatory 0 15.00 0 2 0 0.00 0
3 Bathtub 0 76.00 0 3 0 0.00 0
4 Dishwasher 0 57.00 0 0 0.00 0
5 Foot Basin 0 11.00 0 0 0.00 0
6 Kitchen Sink 0 38.00 0 10 0 0.00 0
7 Laundry,Staionary tub 0 76.00 0 0 0.00 0
8 Pantry Sink 0 19.00 0 5 0 0.00 0
9 Shower 0 114.00 0 3 0 0.00 0
10 Service Sink 0 76.00 0 0 0.00 0
13 Other 0 0 0 0.00 0
13 Other 0 0 0 0.00 0
15 Other 0 0 0 0.00 0
2 0.03 15
Possible Maximum Demand 8 litres per hour
Probable Maximum Demand 2 litres per hour
Storage tank capacity 3 litres per hour
Selected Storage tank capacity 30 litres per hour

POWDER ROOM, KITCHEN (Typical)


Fixture details Heater sizing Pipe sizing
Total design
Total litres per hour Total Loading
# Fixture Type Qty. of Fixtures Litres of Water per hour/per fixture Loading units discharge Pipe sizes Remarks
per fixture units
(gpm)
1 Basin,private Lavatory 1 7.60 8 2 2 0.03 15
2 Basin,public lavatory 0 15.00 0 2 0 0.00 0
3 Bathtub 0 76.00 0 3 0 0.00 0
4 Dishwasher 0 57.00 0 0 0.00 0
5 Foot Basin 0 11.00 0 0 0.00 0
6 Kitchen Sink 1 38.00 38 10 10 0.30 25
7 Laundry,Staionary tub 0 76.00 0 0 0.00 0
8 Pantry Sink 0 19.00 0 5 0 0.00 0
9 Shower 0 114.00 0 3 0 0.00 0
10 Service Sink 0 76.00 0 0 0.00 0
13 Other 0 0 0 0.00 0
13 Other 0 0 0 0.00 0
15 Other 0 0 0 0.00 0
12 0.33 25
Possible Maximum Demand 46 litres per hour
Probable Maximum Demand 14 litres per hour
Storage tank capacity 17 litres per hour
Selected Storage tank capacity 30 litres per hour

KITCHEN,MAID ROOM (Typical)


Fixture details Heater sizing Pipe sizing
Total design
Total litres per hour Total Loading
# Fixture Type Qty. of Fixtures Litres of Water per hour/per fixture Loading units discharge Pipe sizes Remarks
per fixture units
(gpm)
1 Basin,private Lavatory 1 7.60 8 2 2 0.03 15
2 Basin,public lavatory 0 15.00 0 2 0 0.00 0
3 Bathtub 0 76.00 0 3 0 0.00 0
4 Dishwasher 0 57.00 0 0 0.00 0
5 Foot Basin 0 11.00 0 0 0.00 0
6 Kitchen Sink 1 38.00 38 10 10 0.30 25
7 Laundry,Staionary tub 0 76.00 0 0 0.00 0
8 Pantry Sink 0 19.00 0 5 0 0.00 0
9 Shower 1 114.00 114 3 3 0.07 15
10 Service Sink 0 76.00 0 0 0.00 0
13 Other 0 0 0 0.00 0
13 Other 0 0 0 0.00 0
15 Other 0 0 0 0.00 0
15 0.38 25
Possible Maximum Demand 160 litres per hour
Probable Maximum Demand 48 litres per hour
Storage tank capacity 60 litres per hour
Selected Storage tank capacity 80 litres per hour

POWDER ROOM, KITCHEN,MAID ROOM (Typical)


Fixture details Heater sizing Pipe sizing
Total design
Total litres per hour Total Loading
# Fixture Type Qty. of Fixtures Litres of Water per hour/per fixture Loading units discharge Pipe sizes Remarks
per fixture units
(gpm)
1 Basin,private Lavatory 2 7.60 15 2 4 0.10 15
2 Basin,public lavatory 0 15.00 0 2 0 0.00 0
3 Bathtub 0 76.00 0 3 0 0.00 0
4 Dishwasher 0 57.00 0 0 0.00 0
5 Foot Basin 0 11.00 0 0 0.00 0
6 Kitchen Sink 1 38.00 38 10 10 0.30 25
7 Laundry,Staionary tub 0 76.00 0 0 0.00 0
8 Pantry Sink 0 19.00 0 5 0 0.00 0
9 Shower 1 114.00 114 3 3 0.07 15
10 Service Sink 0 76.00 0 0 0.00 0
13 Other 0 0 0 0.00 0
13 Other 0 0 0 0.00 0
15 Other 0 0 0 0.00 0
17 0.41 25
Possible Maximum Demand 167 litres per hour
Probable Maximum Demand 50 litres per hour
Storage tank capacity 63 litres per hour
Selected Storage tank capacity 80 litres per hour

BED ROOM - PRVT LAVATORY (1NO#) & SHOWER (Typical)


Fixture details Heater sizing Pipe sizing
Total design
Total litres per hour Total Loading
# Fixture Type Qty. of Fixtures Litres of Water per hour/per fixture Loading units discharge Pipe sizes Remarks
per fixture units
(gpm)
1 Basin,private Lavatory 1 7.60 8 2 2 0.03 15
HOT WATER HEATER CAPACITY CALCULATON & PIPE SIZING
Project No. 3481 Date 08/05/2023
Project Name SERENIA LIVING -TOWER-1,2,3 & 4 Prepared By RR
Checked By DW
Issue IFC

Building Type: Apartment/House


Demand Factor 30%
Storage Capacity Factor 125%

2 Basin,public lavatory 0 15.00 0 2 0 0.00 0


3 Bathtub 0 76.00 0 3 0 0.00 0
4 Dishwasher 0 57.00 0 0 0.00 0
5 Foot Basin 0 11.00 0 0 0.00 0
6 Kitchen Sink 0 38.00 0 10 0 0.00 0
7 Laundry,Staionary tub 0 76.00 0 0 0.00 0
8 Pantry Sink 0 19.00 0 5 0 0.00 0
9 Shower 1 114.00 114 3 3 0.07 15
10 Service Sink 0 76.00 0 0 0.00 0
13 Other 0 0 0 0.00 0
13 Other 0 0 0 0.00 0
15 Other 0 0 0 0.00 0
5 0.13 15
Possible Maximum Demand 122 litres per hour
Probable Maximum Demand 36 litres per hour
Storage tank capacity 46 litres per hour
Selected Storage tank capacity 50 litres per hour

BED ROOM - PRVT LAVATORY (2 NO#) & SHOWER (Typical)


Fixture details Heater sizing Pipe sizing
Total design
Total litres per hour Total Loading
# Fixture Type Qty. of Fixtures Litres of Water per hour/per fixture Loading units discharge Pipe sizes Remarks
per fixture units
(gpm)
1 Basin,private Lavatory 2 7.60 15 2 4 0.10 15
2 Basin,public lavatory 0 15.00 0 2 0 0.00 0
3 Bathtub 0 76.00 0 3 0 0.00 0
4 Dishwasher 0 57.00 0 0 0.00 0
5 Foot Basin 0 11.00 0 0 0.00 0
6 Kitchen Sink 0 38.00 0 10 0 0.00 0
7 Laundry,Staionary tub 0 76.00 0 0 0.00 0
8 Pantry Sink 0 19.00 0 5 0 0.00 0
9 Shower 1 114.00 114 3 3 0.07 15
10 Service Sink 0 76.00 0 0 0.00 0
7 0.20 20
Possible Maximum Demand 129 litres per hour
Probable Maximum Demand 39 litres per hour
Storage tank capacity 48 litres per hour
Selected Storage tank capacity 50 litres per hour

BED ROOM - PRVT LAVATORY (1NO#), SHOWER (1NO#) & BATH TUB (1NO#) (Typical)
Fixture details Heater sizing Pipe sizing
Total design
Total litres per hour Total Loading
# Fixture Type Qty. of Fixtures Litres of Water per hour/per fixture Loading units discharge Pipe sizes Remarks
per fixture units
(gpm)
1 Basin,private Lavatory 1 7.60 8 2 2 0.03 15
2 Basin,public lavatory 0 15.00 0 2 0 0.00 0
3 Bathtub 1 76.00 76 3 3 0.07 15
4 Dishwasher 0 57.00 0 0 0.00 0
5 Foot Basin 0 11.00 0 0 0.00 0
6 Kitchen Sink 0 38.00 0 10 0 0.00 0
7 Laundry,Staionary tub 0 76.00 0 0 0.00 0
8 Pantry Sink 0 19.00 0 5 0 0.00 0
9 Shower 1 114.00 114 3 3 0.07 15
10 Service Sink 0 76.00 0 0 0.00 0
13 Other 0 0 0 0.00 0
13 Other 0 0 0 0.00 0
15 Other 0 0 0 0.00 0
8 0.23 20
Possible Maximum Demand 198 litres per hour
Probable Maximum Demand 59 litres per hour
Storage tank capacity 74 litres per hour
Selected Storage tank capacity 100 litres per hour

BED ROOM - PRVT LAVATORY (2 NO#) , SHOWER & BATH TUB(Typical)


Fixture details Heater sizing Pipe sizing
Total design
Total litres per hour Total Loading
# Fixture Type Qty. of Fixtures Litres of Water per hour/per fixture Loading units discharge Pipe sizes Remarks
per fixture units
(gpm)
1 Basin,private Lavatory 2 7.60 15 2 4 0.10 15
2 Basin,public lavatory 0 15.00 0 2 0 0.00 0
3 Bathtub 1 76.00 76 3 3 0.07 15
4 Dishwasher 0 57.00 0 0 0.00 0
5 Foot Basin 0 11.00 0 0 0.00 0
6 Kitchen Sink 0 38.00 0 10 0 0.00 0
7 Laundry,Staionary tub 0 76.00 0 0 0.00 0
8 Pantry Sink 0 19.00 0 5 0 0.00 0
9 Shower 1 114.00 114 3 3 0.07 15
10 Service Sink 0 76.00 0 0 0.00 0
13 Other 0 0 0 0.00 0
13 Other 0 0 0 0.00 0
15 Other 0 0 0 0.00 0
10 0.30 25
Possible Maximum Demand 205 litres per hour
Probable Maximum Demand 62 litres per hour
Storage tank capacity 77 litres per hour
Selected Storage tank capacity 100 litres per hour
HOT WATER HEATER CAPACITY CALCULATON & PIPE SIZING
Project No. 3481 Date 08/05/2023
Project Name SERENIA LIVING -TOWER-1,2,3 & 4 Prepared By RR
Checked By DW
Issue IFC

Building Type: Apartment/House


Demand Factor 30%
Storage Capacity Factor 125%

BED ROOM - PRVT LAVATORY (2 NO#) , SHOWER (2 NO#) & BATH TUB(Typical)
Fixture details Heater sizing Pipe sizing
Total design
Total litres per hour Total Loading
# Fixture Type Qty. of Fixtures Litres of Water per hour/per fixture Loading units discharge Pipe sizes Remarks
per fixture units
(gpm)
1 Basin,private Lavatory 2 7.60 15 2 4 0.10 15
2 Basin,public lavatory 0 15.00 0 2 0 0.00 0
3 Bathtub 1 76.00 76 3 3 0.07 15
4 Dishwasher 0 57.00 0 0 0.00 0
5 Foot Basin 0 11.00 0 0 0.00 0
6 Kitchen Sink 0 38.00 0 10 0 0.00 0
7 Laundry,Staionary tub 0 76.00 0 0 0.00 0
8 Pantry Sink 0 19.00 0 5 0 0.00 0
9 Shower 2 114.00 228 3 6 0.17 20
10 Service Sink 0 76.00 0 0 0.00 0
13 Other 0 0 0 0.00 0
13 Other 0 0 0 0.00 0
15 Other 0 0 0 0.00 0
13 0.35 25
Possible Maximum Demand 319 litres per hour
Probable Maximum Demand 96 litres per hour
Storage tank capacity 120 litres per hour
Selected Storage tank capacity 150 litres per hour

KIDS PLAY AREA


Fixture details Heater sizing Pipe sizing
Total design
Total litres per hour Total Loading
# Fixture Type Qty. of Fixtures Litres of Water per hour/per fixture Loading units discharge Pipe sizes Remarks
per fixture units
(gpm)
1 Basin,private Lavatory 1 7.60 8 2 2 0.03 15
2 Basin,public lavatory 0 15.00 0 2 0 0.00 0
3 Bathtub 0 76.00 0 3 0 0.00 0
4 Dishwasher 0 57.00 0 0 0.00 0
5 Foot Basin 0 11.00 0 0 0.00 0
6 Kitchen Sink 0 38.00 0 10 0 0.00 0
7 Laundry,Staionary tub 0 76.00 0 0 0.00 0
8 Pantry Sink 0 19.00 0 5 0 0.00 0
9 Shower 0 114.00 0 3 0 0.00 0
10 Service Sink 0 76.00 0 0 0.00 0
13 Other 0 0 0 0.00 0
13 Other 0 0 0 0.00 0
15 Other 0 0 0 0.00 0
2 0.03 15
Possible Maximum Demand 8 litres per hour
Probable Maximum Demand 2 litres per hour
Storage tank capacity 3 litres per hour
Selected Storage tank capacity 30 litres per hour

SPA & SAUNA AREA - MALE


Fixture details Heater sizing Pipe sizing
Total design
Total litres per hour Total Loading
# Fixture Type Qty. of Fixtures Litres of Water per hour/per fixture Loading units discharge Pipe sizes Remarks
per fixture units
(gpm)
1 Basin,private Lavatory 0 7.60 0 2 0 0.00 0
2 Basin,public lavatory 0 15.00 0 2 0 0.00 0
3 Bathtub 0 76.00 0 3 0 0.00 0
4 Dishwasher 0 57.00 0 0 0.00 0
5 Foot Basin 0 11.00 0 0 0.00 0
6 Kitchen Sink 0 38.00 0 10 0 0.00 0
7 Laundry,Staionary tub 0 76.00 0 0 0.00 0
8 Pantry Sink 0 19.00 0 5 0 0.00 0
9 Shower 2 114.00 228 3 6 0.17 20
10 Service Sink 1 76.00 76 0 0.00 0
13 Other 0 0 0 0.00 0
13 Other 0 0 0 0.00 0
15 Other 0 0 0 0.00 0
6 0.17 20
Possible Maximum Demand 304 litres per hour
Probable Maximum Demand 91 litres per hour
Storage tank capacity 114 litres per hour
Selected Storage tank capacity 150 litres per hour

SPA & SAUNA AREA - FEMALE


Fixture details Heater sizing Pipe sizing
Total design
Total litres per hour Total Loading
# Fixture Type Qty. of Fixtures Litres of Water per hour/per fixture Loading units discharge Pipe sizes Remarks
per fixture units
(gpm)
1 Basin,private Lavatory 0 7.60 0 2 0 0.00 0
2 Basin,public lavatory 0 15.00 0 2 0 0.00 0
3 Bathtub 0 76.00 0 3 0 0.00 0
4 Dishwasher 0 57.00 0 0 0.00 0
5 Foot Basin 0 11.00 0 0 0.00 0
6 Kitchen Sink 0 38.00 0 10 0 0.00 0
7 Laundry,Staionary tub 0 76.00 0 0 0.00 0
8 Pantry Sink 0 19.00 0 5 0 0.00 0
9 Shower 2 114.00 228 3 6 0.17 20
10 Service Sink 1 76.00 76 0 0.00 0
13 Other 0 0 0 0.00 0
13 Other 0 0 0 0.00 0
15 Other 0 0 0 0.00 0
6 0.17 20
Possible Maximum Demand 304 litres per hour
Probable Maximum Demand 91 litres per hour
Storage tank capacity 114 litres per hour
Selected Storage tank capacity 150 litres per hour
NOTES 1. THE BUILDING TYPE HAS BEEN SELECTED FROM THE PREDEFINED ASHRAE CATEGORIES AS THE NEAREST TYPE TO THE PROJECT.
2. THE NUMBER OF FIXTURES HAVE BEEN BASED ON THE LATEST ARCHITECTURAL LAYOUTS