Professional Documents
Culture Documents
IECEx INE 12.0011X 000
IECEx INE 12.0011X 000
of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification System for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com
Equipment: Three-phase asynchronous tube cooled motors and generators type W22XdC...T... 500... up to 710...
Optional accessory:
Signature:
(for printed version)
Date:
Additional
manufacturing
locations:
This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the
IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and
found to comply with the IECEx Quality system requirements.This certificate is granted subject to the conditions as set out in IECEx Scheme
Rules, IECEx 02 and Operational Documents as amended
STANDARDS :
The equipment and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found
to comply with the following standards
IEC 60079-1:2007-04 Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
Edition:6
IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
Edition:6.0
IEC 60079-31:2013 Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
Edition:2
IEC 60079-7:2006-07 Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
Edition:4
This Certificate does not indicate compliance with safety and performance requirements
other than those expressly included in the Standards listed above.
Test Report:
FR/INE/ExTR14.0068/00
EQUIPMENT:
Equipment and systems covered by this Certificate are as follows:
Range of three-phase asynchronous motor with frame in welded steel and endshields in welded steel or cast iron.
Motors can be fitted with different terminal boxes and auxiliary boxes protected by flameproof enclosure or by increased safety.
This equipment is also protected by type protection "tb" for using in dust explosive atmospheres.
The motor may be designed with one up to four speed.
Mounting position of motor can be either horizontal or vertical.
Cooling types can be IC511, IC516 or IC518 according to IEC 60034-6.
The terminal boxes can be fitted directly on the motors or by an adaptor. They are made in cast iron, steel or stainless steel.
Terminal or auxiliary boxes don’t communicate with the motor, the compartments are separated by bushing covered by Ex component. As a variation the
connection can be made through a blanking cap with an unterminated cable. In this case the terminal boxes can be supplied in separated.
Temperature sensors may be incorporated in the stator windings and/or in the bearings.
Resistances may be located inside of the motor mounted on each top of the frame.
Heating resistances could be also mounted inside the terminal boxes protected by flameproof enclosures.
Terminal boxes can be mounted on the top or left/right side, located in any position of a 180° range around the upper part of the frame.
Motors supplied through a frequency inverter and motors with separate ventilation are always fitted with temperature sensors.
The motors get the degrees of protection IP55, IP56, IP65 or IP66 according to IEC 60034 - Part 5.
The terminal boxes type CG47, CEFGH340, CEFGH500, WTBX-XS, WTBX-S, WTBX-M and WTBX-L get the degrees of protection IP66 in accordance
with IEC 60529.
The motor and/or terminal boxes can be fitted with different Ex components. All components are stipulated on the descriptive documents.
As a variant, instead of cylindrical flameproof joint, labyrinth flameproof joints can be used between the inner bearing caps and the labyrinth rings mounted
on the shaft or manufactured on the shaft itself.
A drain and breathing device can be mounted on the motor or on the terminal boxes.
Annex:
Maximum frequencies:
Without frequency inverter : 50 Hz or 60 Hz.
With frequency inverter : Up to 150Hz.
MARKING
Marking has to be readable and indelible; it has to include the following indications:
When the terminal box is protected by increased safety the following indications:
• (rated voltage and rated current and/or rated power)
When the terminal box is located outside of the motor and connected with a cable to the motor the
following indications:
• IECEx INE 12.0011X
• Ex d IIC T4 Gb or Ex e IIC T4 Gb or Ex d ia IIC T4 Gb or Ex d ib IIC T4 Gb or Ex e ia IIC T4 Gb or
Ex e ib IIC T4 Gb or
• Ex d IIC T3 Gb or Ex e IIC T3 Gb or Ex d ia IIC T3 Gb or Ex d ib IIC T3 Gb or Ex e ia IIC T3 Gb or
Ex e ib IIC T3 Gb and/or
• Ex tb IIIC T125°C or T135°C Db IP65 or IP66 or Ex ia tb IIIC T125°C or T135°C Db IP65 or IP66 or
• Ex ib tb IIIC T125°C or T135°C Db IP65 or IP66
• Rated voltage and rated current and/or rated power are mandatory only for "Ex e" version
WARNINGS:
• DO NOT OPEN WHEN ENERGIZED.
• DO NOT OPEN IF AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT.
(*) Type is completed by numbers and letters corresponding to the manufacturer variations.
(**) Mandatory mention when the range of the ambient temperatures differs from –20°C to 40°C:
-55ºC/+40ºC or -55ºC/+50ºC or -55ºC/+60ºC or-40ºC/+40ºC or -40ºC/+50ºC or -40ºC/+60ºC or -
30ºC/+40ºC or -30ºC/+50ºC or -30ºC/+60ºC or-20ºC/+50ºC or -20ºC/+60ºC.
(***) 85°C for ambient 50°C or 95°C for ambient 60°C when the cable glands are fitted on the terminal
box.
95°C for ambient 40°C, 105°C for ambient 50°C or 115°C for ambient 60°C when the cable glands
are fitted on the blanking cover of motors supplied by flying leads.
IECEx Certificate
of Conformity
Certificate No.: IECEx INE 12.0011X
Issue No.: 0
Page 3 of 5
Annexe: IECEx INE 12.0011X_Annex.pdf
In accordance with clause 16.1 of the IEC 60079-1 standard, each equipment defined above has to have
successfully passed, before delivery, an overpressure test of a period comprised between 10 and 60
seconds under:
Pressure
In accordance with § 16.2 of the IEC 60079-1 standard, the following terminal boxes defined above are
exempted of routine test due to the fact that they have undergone a static type test at 4 times the
reference pressure under:
Pressure
In accordance with clause 7.1 of the IEC 60079-7 standard, the intercalary and the terminal boxes type
CG47, CEFGH340, CEFGH500, WTBX-XS, WTBX-S, WTBX-M and WTBX-L protected by increased safety must
have successfully passed before delivery a dielectric strength test on each of the different circuits of the
connection units, performed according to the relevant standards, the supply voltage shall be applied
during one minute.
IECEx Certificate
of Conformity
Certificate No.: IECEx INE 12.0011X
Issue No.: 0
Page 4 of 5
Annexe: IECEx INE 12.0011X_Annex.pdf
LIST OF THE COMPONENT INTENDED TO BE INSTALLED ON THE MOTOR AND/OR TERMINAL BOXES