Professional Documents
Culture Documents
Blood Culture Collection Wingetset Poster Provided by Biomerieux
Blood Culture Collection Wingetset Poster Provided by Biomerieux
1 CHECK
2 3 4
trademarks belonging to bioMérieux , or one of its subsidiaries, or one of its companies. Any other name or trademark is the property of its respective owner / bioMérieux S.A. RCS Lyon 673 620 399 / Printed in France / thera / RCS Lyon B 398 160 242
PREPARE BOTTLES FOR INOCULATION PREPARE VENIPUNCTURE SITE COLLECT WITH WINGED SET
PATIENT ID
Palpate to find
& PREPARE Wash hands or the vein. Attach the
MATERIAL use an alcohol
Apply clean collection set to
hand rub. the adapter cap.
examination
gloves.
Remove the plastic To prevent
“flip-cap”. Disinfect
the skin. contamination, do
Disinfect the not re-palpate.
bottle septum and Allow the site to Insert the needle into
allow to air dry. air dry. the prepared vein.
5 BOTTLE INOCULATION
6 FINISH THE PROCEDURE
Record collection date, time
7 CORRECT LABELING DO NOT
Collect the aerobic
and site.
bottle first.
Ensure the bottle is Label bottles according to
correctly filled to manufacturer’s
the Fill-to Mark or recommendations.
target fill level, as Transport inoculated bottles as
shown. quickly as possible at room Leave cotton Replace the Position label in
Repeat for temperature to laboratory for over the septum plastic “flip-cap” the wrong place
anaerobic bottle. testing.
www.biomerieux.com
bioMérieux S.A. • 69280 Marcy l’Etoile • France • Tel.: + 33 (0)4 78 87 20 00 • Fax: +33 (0)4 78 87 20 90
www.biomerieux.com www.biomerieux.com/en/education