You are on page 1of 17

Design and Construction of Changi East Rail Depot

(Main Workshop Building)

Technical Data Review Project


Contract CR101
Number:

To: MCC Engineering (Singapore) Pte Ltd


Ref No. CR101_MWBD_RC_01_0001

Contract No/ Package Description:


Contract CR101

Prepared & Submitted by: Hong Yang Development Pte Ltd

PART 1: Particulars Of Submission

Type of Works:
❑ Architectural  Landscaping
❑ Civil & Structural ❑ Interior Design / Fit-out
❑ Mechanical & Electrical ❑ Others:-
Description of
Material/Equipment:
Country of
Manufacturer: Protec Green Pte Ltd Singapore
Origin:

Brand: Protec Model: Pro Grout S40 Eco

Location of use: Main Workshop Building (for concrete


Revision No: Rev 0
common defect grouting/patching, etc.)
Attachments:
 Catalogues ❑ Safety Data Sheet
❑ Datasheets ❑ Reports
❑ Technical Specification ❑ Project References
❑ Certificates ❑ Others: - Company Profile
❑ Calculations
Remarks/Comments:

1. We hereby confirm that the item submitted herein complies with the Contract.
2. Any approval given by the Owner shall not in any way relieve our obligation under the Contract: -
(a) to ensure its correctness, accuracy, adequacy and/or suitability of such item for the Works; and
(b) such item supplied are of good quality and reasonably fit for their purpose which shall include but limited to fulfil
the aesthetics, functional aspects and/or performance parameters set out in the Owner’s Requirements.
Name & Designation Signature Date of Submission
Prepared and :
Requested by Mr. Sun Hao (Project Manager) 02 Aug 2023

PART 2: Review Comments/ Recommendation

❑ A - Approved ❑ B – Approved with Comments


❑ C - Review not Required ( Issued For Info) ❑ D - Rejected
Remarks/Comments:

Name & Designation: Company: Signature: Date:


MCC Engineering (Singapore)
Pte Ltd.

Page 1 of 1
Prospaq Group Pte Ltd
Prospaq Group Pte Ltd is a Singapore-based
company and is one of the largest importers of
sands and aggregates in Singapore. We are a
supplier of sand, aggregates, Ordinary Portland
Cement, pre-mixed construction materials and
Autoclaved Aerated Concrete (AAC) blocks.

Prospaq Group also provides services such as


equipment rental of excavators, lorry crane,
tipper lorry services and stevedoring services for
bulk carriers and barges etc.
Prospaq Group has an estimated yearly turnover of S$50 million and owns several facilities in Singapore
which serves as our office, manufacturing plant and warehouse. Our company also has several storage
plots at BCA Aggregate Terminal in Tuas.
Prospaq Group strives to exceed the expectations of our customers by offering excellent quality
products and outstanding customer service. We value our relationship with all our business associates
and is committed to maintaining long term good working relationship throughout.
Our management team has more than 15 years of experience in the construction industry and is directly
engaged with our staff to develop better products and improve our services. We emphasize on the
functional and technical expertise of our staff to ensure we are delivering the best in products and services
to all our customers.

For more information, kindly contact us at:


PROSPAQ GROUP PTE LTD Tel: 6269 9532 (4 lines) 6269 9469 (2 lines)
No. 3 Sungei Kadut Street 6 Fax: 6368 1193
Singapore 728851 Email: prospaq@singnet.com.sg
Product Range

HDB Project Private Project


ECO Products: ECO Products:
1) PRO Coat Internal ECO 1) PRO Plaster-P ECO
2) PRO Coat External ECO 2) PRO Plaster WP ECO
3) PRO Plaster-H ECO 3) PRO Screed ECO
4) PRO Screed ECO 4) PRO Screed WP ECO
5) PRO Screed WP ECO 5) PRO Screed Self-Levelling ECO
6) PRO Tile Bond-H ECO (C2TES1) 6) PRO Finish Coat ECO
7) PRO Grout S40 ECO 7) PRO Finish Coat ECO (White)
8) PRO Grout S40F ECO 8) PRO Tile Bond-P ECO
9) PRO Grout S70 ECO 9) PRO Grout S40 ECO
10) PRO Grout S70B ECO 10) PRO Grout S40F ECO
11) PRO Bond 202 ECO 11) PRO Grout S70 ECO
12) PRO Finish Coat ECO (WHITE) 12) PRO Grout S70B ECO
13) PRO Thin Bed ECO 13) PRO Thin Bed ECO
14) PRO Bond 202
15) PRO Bond 205
Ordinary Portland Cement
1) OPC Cement Others Building Materials
1) Custom Size Aggregate
Sands and Aggregate 2) Unwashed Sand
1) Concrete Sands
3) 30/60 Dry Sand
2) Coarse Concrete Sands
4) Graded Stone
3) White Fine Sand
5) Crusher Run
4) Plaster Sands
6) Hollow Block
5) 10mm Chipping
7) Red Brick
6) 20mm Aggregate
8) Autoclaved Aerated Concrete (AAC)
7) Quarry Dust
Block
PROSPAQ GROUP PTE LTD
PRO GROUT S40 ECO - JOB REFERENCE
MAIN CONTRACTOR PROJECT

DAIYA ENGINEERING & CONSTRUCTION PTE LTD SEMI-D CLUSTER @ CORONATION


JIAN YU CONSTRUCTION PTE LTD 16 LEEDON PARK PROJECT
JIA YI CONSTRUCTION PTE LTD DORMITORY@TRACTOR ROAD
TAT HIN BUILDERS PTE LTD 66KV KAKI BUKIT SUBSTATION
TAT HIN BUILDERS PTE LTD KEAT HONG CC @ CHOA CHU KANG AVE 4
WEE HUR CONSTRUCTION PTE LTD DBS @ CHANGI BUSINESS PARK CRES PROJECT
YONG XING CONSTRUCTION PTE LTD UPGRADING @ SILING PRIMARY SCHOOL
KIENTA ENGINEERING & CONSTRUCTION PTE LTD SAM PROTON THERAPY @ BIOPOLIS DRIVE
BUILDER TRENDS PTE LTD RESINDENCES @ NAMLY CRESCENT
BUILDER TRENDS PTE LTD RESINDENCES @ BELMONT ROAD
BUILDER TRENDS PTE LTD RESINDENCES @ CLUNY ROAD
BUILDER TRENDS PTE LTD RESINDENCES @ MATLOCK RISE
BUILDER TRENDS PTE LTD REINDENCES @ STEVEN ROAD
JIA YI CONSTRUCTION PTE LTD EC TAMPINES CENTRAL 7
KEONG HONG CONSTRUCTION PTE LTD SKYPARK RESIDENCES @ SEMBAWANG CRESCENT
SH DESIGN & BUILD PTE LTD FACTORY @ LENG KEE ROAD
STL CONSTRUCTION PTE LTD ROH @ JURONG EAST & JURONG WEST
STL CONSTRUCTION PTE LTD ROH @ BEDOK SOUTH
TAT HIN BUILDERS PTE LTD CHEMICAL HUB @ TUAS SOUTH DRIVE
TAT HIN BUILDERS PTE LTD 66KV SUB STATION @ LOYANG DRIVE
YONG XING CONSTRUCTION PTE LTD UPGRADING @ BOON LAY PRIMARY SCHOOL
YONG XING CONSTRUCTION PTE LTD UPGRADING @ AHMAD IBRAHIM PRIMARY SCHOOL
YONG XING CONSTRUCTION PTE LTD UPGRADING @ STAMFORD PRIMARY SCHOOL
Y3 CONSTRUCTION PTE LTD CONTRACT T202 MRT PROJECT
Y3 CONSTRUCTION PTE LTD CONTRACT T206 MRT PROJECT
Y3 CONSTRUCTION PTE LTD CONTRACT T211 MRT PROJECT
Y3 CONSTRUCTION PTE LTD CONTRACT T212 MRT PROJECT
SOON HE CONSTRUCTION PTE LTD EUROKARS @ PENJURU
ELEMENT CONSTRUCTION PTE LTD YISHUN HDB HIP G24D
ELEMENT CONSTRUCTION PTE LTD TAMPINES HDB HIP G24D
KAY LIM CONSTRUCTION & TRADING P/L TAMPINES N6C8-C10 (HDB)
PROSPAQ GROUP PTE LTD
PRO GROUT S40 ECO - JOB REFERENCE
MAIN CONTRACTOR PROJECT
GREAT WALL CONSTRUCTION (CNQC M/C) FOREST CITY (MALAYSIA)
JIA YI CONSTRUCTION PTE LTD BIDADARI C10-C12
QINGJIAN INTERNATIONAL (SP) P/L YISHUN N4C21B
QINGJIAN INTERNATIONAL (SP) P/L WOODLAND N7C33
TEAMBUILD ENGINEERING & CONSTRUCTION P/L 12 STOREY NURSING HOME @SENJA RD
TIONG SENG CONTRACTOR PTE LTD SLOANE RESIDENCES @ 17 BALMORAL RD
TIONG SENG CONTRACTOR PTE LTD NURSING HOME @ SERANGOON/BALESTIER RD
SG UNITED CONSTRUCTION PTE LTD 53 UNIT TERRANCE HOUSE @ LOR 1 REALTY RD
CHAN RONG FEN BUILDING CONSTRUCTION P/L TAMPINES CONTRACT 17 & 18
PRELIM CONSTRUCTION PTE LTD TAMPINES C19
RIGHT CONSTRUCTION PTE LTD PUNGGOL NORTH CONTRACT 4
RIGHT CONSTRUCTION PTE LTD GEYLANG CONTRACT 29/30
NEWCON CONSTRUCTION PTE LTD BEDOK N2C11
NEWCON CONSTRUCTION PTE LTD TOA PAYOH N1 C25/C25A
NEWCON CONSTRUCTION PTE LTD WOODLAND N7C27
QINGJIAN INTERNATIONAL (SP) P/L DAINTREE RESIDENTIAL @ TOH TUCK RD
PRO GROUT S40 ECO
BRAND/PRODUCT NAME

PRO GROUT S40 ECO

MANUFACTURER

PROTEC GREEN PTE LTD


NO. 3 Sungei Kadut Street 6
Singapore 728851
Tel: 62695395 Fax: 63671008

PRODUCT DESCRIPTION

PRO GROUT S40 ECO is an environmentally friendly premixed cement base non-shrink grout
that is non-corrosive, non-oxidizing and is free of chlorides and nitrates. PRO GROUT S40 ECO is
formulated for general purpose grouting needs and is commonly used to repair structural
building members.

ADVANTAGES

• Factory blended pre-packed ensures high quality product


• Easy mixing and application
• Excellent adhesion strength
• Fast setting
• Economical – saves time, labour and money
• High performance

USES

PRO GROUT S40 ECO is a general purpose grout for patching of masonry/substrate and is also
recommended for structural concrete repairs like under plates, beams and columns and post
tensioned girders.

PGS40-2010
INSTALLATION TECHNICAL DATA
Surface Preparation Performance Properties:
Surfaces receiving PRO GROUT S40 ECO must Test/Test Method Results
be clean and sound. Remove all dust and any
loose materials before commencing works. Flow Consistency
30% - 45%
Thoroughly wet all surfaces and keep substrate ASTM-C1437
in a moist condition during placement. Any
Compressive Strength
stagnant surface water must be removed before > 40 N/mm²
ASTM C109/C109M
application.
Slant Shear Bond Strength
> 1.5N/mm²
Mixing BS EN12615
Use approximately 4 to 5 litres of clean potable
water to a bag of 25kg PRO GROUT S40 ECO. Volume Change
0 to +3
ASTM C827 /C827M
For best results a mechanically powered grout
mixer should be used. Setting Time
-Initial Set > 60 mins
Place measured water into grout mixer, then -Final Set ≤ 240 mins
gradually add the powder and mix thoroughly ASTM BS EN196:3
for approximately 3-5 minutes till an even Yield Per Bag 0.013 m³
consistency is obtained. Pot Life 60 mins (Approx.)

Additional aggregates use for bulking the


thickness must be added before PRO GROUT SHELF LIFE
S40 ECO. The additional rate would be 10-15 kg Approximately 12 months in factory sealed
to 25kg of PRO GROUT S40 ECO. packaging and should be stored indoor and off
the ground in dry area.
Application *High humidity will reduce the shelf life of bagged
Hand placing or “dry packing” of PRO GROUT cementitious product.
S40 ECO must be done with sufficient water to
produce a plastic consistency and to assure CAUTION
hydration and strength development of the This product contains Portland Cement and
grout. Silica Sand. Mix in a well-ventilated area and
avoid breathing powder or dust. Use PPE as
Minimum thickness for PRO GROUT S40 ECO is required. Avoid contact with eyes, skin, and
10mm and the maximum thickness is 100mm. clothing. Wash hands thoroughly after
handling.
Recommended application thickness is 20mm *Refer SDS for safety precautions of this product.
to 50mm in one pour. Grout pour should done
in stages if require thickness exceed 100mm or
have 5-10mm washed coarse aggregates added SALES AND TECHNICAL SERVICES
to it.

After initial hardening of the grout, all exposed


areas should be thoroughly cured by means of PROSPAQ GROUP PTE LTD
water application, or under wet burlaps, or by No. 3 Sungei Kadut Street 6, Singapore 728851
application of PRO range of curing compounds. Tel: 6816 8228
Fax: 6368 1193
PACKAGING Email: sales@prospaq.com
PRO GROUT S40 ECO comes in 25kg bag. Website: http://prospaq.com

The information in this catalogue is provided to the best of our knowledge from results gathered both internal and external credited laboratories.
However, we have no control over site application, site conditions and workmanship of the applicator. We therefore will not accept any liability, either
directly or indirectly arising from the misuse of these products or when the product is used not in accordance with any advice, specification, and
recommendation of information given by us. The user is responsible for checking the suitability of these products for its intended use.
PRO GROUT S40 ECO

SAFETY DATA SHEET


DATE OF ISSUE: 01 MARCH 2022 (REV 03)

1. IDENTIFICATION OF PRODUCT

Product Name: PRO GROUT S40 ECO


Product Form: Powder
Intended Use: Non-Shrink Grout
Manufacturer: Protec Green Private Limited
Registered Address:3 Sungei Kadut Street 6, Singapore 728851
Telephone: +65 62699532
Facsimile: +65 63681198

2. INFORMATION OF INGREDIENTS
This preparation is comprising of cement, sand and additives. The precise formulation is confidential information. The Product
formulation does not use asbestos or other known toxic substances, and does not require the use of toxic solvents in commonly
known construction application. This preparation contains no ingredients classifiable by the requirements of 67/548/EEC as
amended by 79/831/EEC. For more information, refer product data sheet.

3. HAZARDS INDENTIFICATION
The material content of this preparation is irrespirable size and is not likely to present an inhalation hazard. However, exposure to
dust from this preparation should be regarded as potentially harmful. This preparation is mildly alkaline when wet. Avoid inhalation
and contact with eye and skin. Presents no particular risk to the environment, provided the disposal requirements and national or
local regulations are complied with.

4. FIRST AID MEASURES


Ingestion: Remove to fresh air. Do not induce vomiting. Rinse mouth with water. Give half pint (300ml) water to drink until remain
away until coughing and other symptoms subside.
Inhalation: Will cause irritation of mucous membranes, nose, eyes, throat coughing and difficulty of breathing. Exposure to high
vapour concentration may cause headache, dizziness, nausea and narcosis. In the event of respiratory difficulties, apply standard
first aid techniques as appropriate to the condition of the patient and get immediate medical attention.
Skin: Prolonged contract causes common solvent defatting effect. Wash with mild soap and water.
Eyes: Vapours slightly uncomfortable, splashes irritating. Will cause painful burning or stinging of eyes and lids. Watering eyes and
inflammation of Conjunctiva. Wash out immediately with plenty of water or normal saline solution and obtain medical advice at
once.

5. FIRE FIGHTING MEASURES


Inorganic powder.
Will not burn or support combustion. Compatibles with all standard firefighting techniques. No special procedures required.

6. ACCIDENT RELEASE MEASURES


Contain spillage. Take precautions against excessive dust exposure (use approved respiratory protection), shovel into bags or other
suitable containers. Small spillage may be washed to drain with plenty of water.
Spillage which becomes damp will set and harden. Clean up spillage promptly.
Additional advice : Avoid dust formation during clean up.

7. EXPOSURE CONTROLS
Engineering Control: General or local ventilation as necessary to prevent any dust exposure greater than the above limits.
Environmental Precautions: Do not flush into surface water or sewers.
Methods for cleaning up: Scoop up contaminated material and place in a disposal container.
Personal Precautions: Although not classed as dangerous, these preparations should be handled in accordance with good
industrial hygiene and safety practices. Following “good practice” precautions are recommended:
- Wear protective clothing, protective gloves, safety goggles and face shield.
- No eating, drinking or smoking when using this product.
- Wash off splashes as soon as possible
- Avoid inhalation of dust or exceeding of occupational limit value.
Wear suitable respiratory protective equipment if working in confined spaces with adequate ventilation. Advice on respiratory
protective equipment is given in British standards BS 2091 and BS 4274 and the HSE publication HS(G)53.

Skin and body protection: None.


Hygiene measures: Wash off splashes with warm water and soap.
Protective measures: Prophylactic use of protective ointment (barrier cream) is recommended.
Page 1 of 2
PRO GROUT S40 ECO

8. STORAGE AND HANDLING


No special conditions. Store in dry place. Keep tightly sealed following use.

9. PHYSICAL AND CHEMICAL PROPERTIES


Appearance : Grey Powder
Odour : Odourless
PH : Not determined
Viscosity : Not applicable
Freezing point : Not applicable
Boiling point : Not applicable
Melting point : Not determined
Flash point : Not applicable
Auto-flammability : Not applicable
Explosive limits : Not applicable
Vapour pressure : Not applicable
Relative density : Not determined
Solubility in water : Insoluble
Partition coeff : Not determined
Vapour density : Not applicable

10. STABILITY AND REACTIVITY


Stability: Stable at normal temperature when kept dry. When wet sets to a hard lump with evolution of small amounts of heat.
Materials & conditions to avoid: None known.
Hazardous decomposition product: None known in normal applications.

11. TOXICOLOGICAL INFORMATION


Ingestion: No specific data available. Not regarded as harmful by ingestion. Unlikely to be any serious ill effects. May
cause minor upset/irritation to digestive system.

Inhalation: Inhalation of quartz (crystalline silica) over long periods can cause silicosis. Dusts other than quartz arising
from this preparation is not likely to cause significant disease or toxic effect if exposure is kept under
reasonable control.

Skin contact: Prolonged contact may cause irritation, especially if wet.

Eye contact: Will cause discomfort and irritation.

12. ECOLOGICAL INFORMATION


Not biodegradable.
Long term ecological effects as for any cement/concrete products

13. DISPOSABLE CONSIDERATIONS


This preparation is not classified as special waste and can be disposed of by landfill at an approved site.
Consult local regulations before disposal.

14. TRANSPORTATION INFORMATION


No special packaging requirements.
Not classified as dangerous goods

15. REGULATION INFORMATION


Not classified as dangerous according to the rules of the EEC “Preparation Directive”88/379/EEC.

16. OTHER INFORMATION


The above information is based on the data which we are aware and is believed to be correct as of the date hereof. It is intended
as a guide for safe handling, storage and use in known applications in the construction industry, but it is not a specification or
guarantee of specific properties, and no liability can be accepted for any loss, injury or damage resulting from its use.

Page 2 of 2

TEST REPORT SETSCO
(This Report is issued subject to the terms & conditions set out below) Setsco Services Pte Ltd
18 Teban Gardens Crescent
Singapore 608925
Tel : (65) 6566 7777
Fax: (65) 6566 7718
www.setsco.com
Your Ref: WO No. W2021002 Our Ref: CT-8500154130/JAS Business Reg No 196900269D
Date: 05/05/2021
Page 1 of 6

Subject Testing of Protec Pro Grout S40 ECO (semi-precast grout) Submitted by Protec
Green Pte Ltd on 29/03/2021.

Tested For PROTEC GREEN PTE LTD


3 Sungei Kadut Street 6
Singapore 728851
Attn: Mr. Jonathan Ong

Method of Test 1) Flow Consistency ASTM C1437: 2015


2) Compressive Strength ASTM C109/C109M: 2016a
3) Setting Time BS EN 196: 3:2016 Annex A
4) Slant Shear Bond Strength BS EN 12615: 1999
5) Volume Change ASTM C827/C827M:2016

Specification HOB Approved Material List: Non-shrink grout for semi-precast construction
stanchion base plate grouting and repair of structure concrete.

Description One (1) of Protec Pro Grout S40 ECO (semi-precast grout) weighing
of Sample approximately 25kg marked HOB/BIG/ML dated 26/03/2021 was received.
(Please refer to photograph 1).

Suresh Mehnan Jasbeer Singh


Testing Officer Engineer (CMTD)
Construction Technology Division

Tenns & Conditions:


(1) The Report is prepared for the sole use of !he Clienl and is prepared based upon lhe llem submilted, lhe services required by lhe Client and the conditions under which the Services are pertormed by SETSCO. The Report is not intended to be
representalive of similar or equivalent Services on similar or equivalent items, The Report does not conslitute an endorsemenl by SETSCO of the item.
(2) SETSCO agrees to use reasonable diligence in the pertormance of the Services but no warranties are given and done may be implied directly or indireclly relating lo the Services, lhe Report or the facililies of SETSCO.
,.-,\'::QJ•-,,�
(3) SETSCO shall under no circumstances be liable to the Client or its agenls, servants or representalives, in conlract, tort (including negligence or breach of stalulory duty) or otherwise for
any direct or indirect loss or damage suttered by the Client, its agents, servants or representative howsoever arising or whelher connected with lhe Services provided by SETSCO Jw11.��
(4) The Report may nol be used in any publicity material without lhe wrilten consent of SETSCO. !'��
(5) The Report shall not be reproduced in part or in full unless approval in wriling has been given by SETSCO. � .1;1;.,{,1 .)),\� L.A-1993-0051-C LA-1998-0144-D
L.A-1993-0067-G LA-2000-01B1-F
L.A-1994-0068-A LA-2012-0519-E
*The results reported herein have been pertormed in accordance with lhe laboratory's lerms of accreditation under the Singapore Accreditalion Council. LA-11197-0001-0 LA�-,on.0001-B,1
SETSCO
CT-8500154130/JAS Page 2 of 6

Mix Proportion

As specified by the manufacturer, the mix proportion used by weight was as follows:

Protec Pro Grout S40 ECO (powder) 1 part


Water 0.165 parts

Mixing Procedure

As specified by the manufacturer, the mixing procedure was as follows:

1. The correct proportion of the above components were weighed.

2. The water was poured in the mixing bowl and the Protec Pro Grout S40 ECO (powder) was added slowly
and mixed simultaneously within 30 seconds at slow speed.

3. The compound was mixed for approximately 2 minutes at slow speed until a homogeneous consistency
was achieved.

4. Separate mixes were made for each of the above determinations.

Test Results

A summary of the tested results are given in Table 1 and the results for flow consistency, compressive
strength, setting time, slant shear bond strength and volume change are given in Tables 2 to 6 respectively.
SETSCO
CT-8500154130/JAS Page 3 of 6

Results:
Table 1: Summary of Tested Results

HDB's Requirement for


Characteristics Protec Pro Grout S40 ECO
Semi-Precast Construction
Water/Powder Ratio - 0.165
Flow Consistency(%) 30~45 42
2
Bond Strength at 28 days(N/mm ) �1.5 7.7
lower limit: 0.00
Volume Change(%) +0.13
upper limit +3.00
Initial �60 60
Setting Time(mins)
Final g40 120
Compressive Strength at 28 days
�40 53.7
(N/mm2 )

Table 2: Flow Consistency

Sample Reference Protec Pro Grout S40 ECO

Specimen Reference
Date of Test
1
I
07/04/2021
2

Ambient Temperature( ° C) 25
Flow Consistency(%)
Average Flow Consistency(%)
42
I
42
42

Table 3: Compressive Strength

Sample Reference Protec Pro Grout S40 ECO

Specimen Reference
Size of Cube (mm)
1
I 2
I 3
I
50
4
I 5
I 6

Date of Cast 07/04/2021


Date of Test 05/05/2021
Age at Test(days) 28

Compressive Strength(N/mm 2)
Average Compressive Strength
55.2
I 53.2
I 51.8
I
53.7
52.3
I 54.4
I 55.0

(N/mm2)
SETSCO
CT-8500154130/JAS Page 4 of6

Results:
Table 4: Setting Time

Sample Reference Protec Pro Grout S40 ECO

Date of Test 07/04/2021

Ambient Temperature (°C) 25

Initial 60
Setting Time (mins)
Final 120

Table 5: Slant Shear Bond Strength

Sample Reference Protec Pro Grout S40 ECO

Reference Specimen Test Specimen


Specimen Reference
1 2 3 1 2 3
Type of Bond Hardened to Fresh
Water cure for : 35 days Cut with concrete cutter and wire brush
Concrete substrate Condition
bond surface
Date of Application of Bonding Material 07/04/2021
Substrate Surface Condition - Damp
°
Curing Condition of Test Specimen Air Cure at 25 C and RH 60 ±15%
Date of Test 05/05/2021
Age at Test (days) 28
Angle between Bond Line and
30
Horizontal Axis
Size of Specimen (mm) 40x40x160
Max Load (F) (kN) 73.8 75.8 74.5 28.5 29.3 27.7
Compressive Strength (N/mm
2
) 46.1 47.7 46.6 - - -
Average Compressive Strength
2 46.8 -
(N/mm )
2
Slant Shear Bond Strength (N/mm ) - - - 7.7 7.9 7.5
Average Slant Shear Bond Strength
2 7.7
(N/mm )
Mode of Failure .. - - - A A A
Remark:
1) A denotes - Adhesion failure at one of the adhesive concrete interfaces
2) *Refer to photograph 2
SETSCO
CT-8500154130/JAS Page 5 of 6

Results:
Table 6: Volume Change

Protec Pro Grout S40 ECO


Sample Reference
A B
Date of Test 05/05/2021
Diameter 50
Nominal Dimensions(mm)
Height 100
Flow of the Test Mixture(%) 42
Magnification 98 98
D
Temperature of the Test Mixture( C) 25.0
Temperature at Time of Moulding Specimen(DC) 25.0
Temperature(DC) 25.0
Test Period
Relative Humidity(%) 64
* Time Interval(mins) 5 5
Volume Change at Time of Hardening of the Test Mixture(%) +0.12 +0.14
3 days +0.12 +0.14
Volume Change at(%)
28 days +0.12 +0.14
Maximum Volume Change Using the Largest Indicating Chart
+0.14
Reading Obtained During the Test Period (%)
Magnitude(mm) 12 14
Maximum
Expansion/Shrinkage ++ Time of Occurrence From
90 130
Start of Test (mins)
Remarks:
1) * From the addition of powder to water in the mixer to the time of start of test.
2) ++ The sign(+) indicates expansion &(-) indicates shrinkage

Graph 1 :Volume Change for Protec Grout S40 ECO

� 0.12
e....
c, 0.1
ea

·;:: 0.08
.c:

-;; 0.06
.2
� 0.04
ea

W 0.02

10 100 1000 10000 100000


Time (Mins)
SETSCO
CT-8500154130/JAS Page 6 of 6

Photograph 1: Shows a bag of Protec Pro Grout S40 ECO as received.

, I

I

.,
, .

' ..

Photograph 2: Shows bond failure of one of the test specimens after


bond strength test at 28 days.
SINGAPORE GREEN BUILDING
PRODUCT CERTIFICATE
AWARDED TO

Protec Green Pte Ltd


3 Sungei Kadut Street 6
Sungei Kadut Industrial Estate
Singapore 728851
FOR THE PRODUCT

Non-Shrink Grout

PRODUCT BRAND

PROTEC

PRODUCT MODEL

PRO GROUT S40 ECO

THE PRODUCT HAS BEEN ASSESSED ACCORDING


TO THE ASSESSMENT CRITERIA OF SINGAPORE
GREEN BUILDING PRODUCT CERTIFICATION SCHEME.
IT HAS BEEN AWARDED THE RATING:

____________________________________
Director
SGBC Pte Ltd

Certificate Number Original Issue Date Revised Date Valid Till


SGBP 3713 27 October 2022 - 26 October 2024

✓Good ✓✓Very Good ✓✓✓Excellent ✓✓✓✓Leader


The use and reliance on this certificate is subject to the terms and conditions of the Singapore Green Building Product
Certification Scheme. Revised certificates may also be issued at the discretion of the Council. The certification status may be
verified at the Singapore Green Building Council website (www.sgbc.sg).
11/07/2023, 14:28 HDB Listing Pro Grout S40 Eco .png

https://drive.google.com/drive/folders/1LzLi7AtcBldX2ZusCvoP0_h3pEUOI5nH 1/1

You might also like