REKAP DATA PERENCANAAN

STASIUN LEBAK BULUS


FOUNDATIONS SUPERSTRUCTURE
No Nama Data No Nama Data
1 Batas Lendutan akibat LL : L/800 1 Batas Lendutan akibat LL : L/800
2 Frequensy alami struktur : 2 Frequensy alami struktur :
3 Batas simpangan : 3 Batas simpangan :
4 Batas regangan : 4 Batas regangan :
5 Batas vibrasi : 5 Batas vibrasi :
6 Mutu beton : 40 MPa 6 Mutu beton : 40 MPa
7 Mutu baja : 390 MPa 7 Mutu baja : 390 MPa
8 Batas pergerakan joint (siar) : 8 Batas pergerakan joint (siar) :
9 Batas layan : 9 Batas layan :
10 Batas settlement : 10 Batas settlement :
11 Batas kemampuan bearing : 11 Batas kemampuan bearing :

fs (for shaft friction in all cases) 1.50 1.50


: fs (for shaft friction in all cases) :
fb (for base resistance under non- fb (for base resistance under non-
12 : 3.00 12 : 3.00
seismic loading) seismic loading)
fb (for base resistance under fb (for base resistance under
: 1.5 : 1.5
seismic loading) seismic loading)

STASIUN FATMAWATI
FOUNDATIONS SUPERSTRUCTURE
No Nama Data No Nama Data
Batas Lendutan (Design Rafter) : 22,75 mm
1 Batas Lendutan akibat LL : L/800 1
Batas Lendutan (Steel Beam) : 62,52 mm
2 Frequensy alami struktur : 2 Frequensy alami struktur :
3 Batas simpangan : 3 Batas simpangan :
4 Batas regangan : 4 Batas regangan :
5 Batas vibrasi : 5 Batas vibrasi :
Mutu beton Pile : 40 MPa
6 6 Mutu beton : 40 MPa
Mutu Beton Pile cap : 50 MPa
7 Mutu baja : 390 MPa 7 Mutu baja : 390 MPa
8 Batas pergerakan joint (siar) : 8 Batas pergerakan joint (siar) :
9 Batas layan : 9 Batas layan :
10 Batas settlement : 10 Batas settlement :
11 Batas kemampuan bearing : 11 Batas kemampuan bearing :

fs (for shaft friction in all cases) 1.50 1.50


: fs (for shaft friction in all cases) :
fb (for base resistance under non- fb (for base resistance under non-
12 : 3.00 12 : 3.00
seismic loading) seismic loading)
fb (for base resistance under fb (for base resistance under
: 1.5 : 1.5
seismic loading) seismic loading)
STASIUN CIPETE RAYA
FOUNDATIONS SUPERSTRUCTURE
No Nama Data No Nama Data
Batas Lendutan (Plint Beam) : 54,7 mm
1 Batas Lendutan akibat LL : L/800 1
Batas Lendutan akibat LL : L/800
2 Frequensy alami struktur : 2 Frequensy alami struktur :
3 Batas simpangan : 3 Batas simpangan :
4 Batas regangan : 4 Batas regangan :
5 Batas vibrasi : 5 Batas vibrasi :
Mutu beton Pile : 40 MPa
6 6 Mutu beton : 40 MPa
Mutu Beton Pile cap : 50 MPa
7 Mutu baja : 390 MPa 7 Mutu baja : 390 MPa
8 Batas pergerakan joint (siar) : 8 Batas pergerakan joint (siar) :
9 Batas layan : 9 Batas layan :
Settlement (Short Time
: 4,5 mm
Settlement)
10 10 Batas settlement :
Settlement (Long Time
: 9,01 mm
Settlement)
11 Batas kemampuan bearing : 11 Batas kemampuan bearing :

fs (for shaft friction in all cases) 1.50 1.50


: fs (for shaft friction in all cases) :
fb (for base resistance under non- fb (for base resistance under non-
12 : 3.00 12 : 3.00
seismic loading) seismic loading)
fb (for base resistance under fb (for base resistance under
: 1.5 : 1.5
seismic loading) seismic loading)

STASIUN HAJI NAWI, BLOK A, BLOK M, SISINGAMANGARAJA, ASEAN


VIADUCT PIER - FOUNDATIONS VIADUCT SUPERSTRUCTURE
No Nama Data No Nama Data
1 Batas Lendutan akibat LL : L/800 1 Batas Lendutan akibat LL : L/800
2 Frequensy alami struktur : 1.24 Hz 2 Frequensy alami struktur : 1.24 Hz
3 Batas simpangan : 3 Batas simpangan :
4 Batas regangan : 4 Batas regangan :
5 Batas vibrasi : 5 Batas vibrasi :
Mutu beton Precast Pile : 80 MPa Mutu beton Precast Pile : 80 MPa
6 Mutu Beton Pile cap, Abutment, 6 Mutu Beton Pile cap, Abutment,
: 32 MPa : 32 MPa
Column, Parapets Column, Parapets
Mutu baja (Mid Steel = BjTP 24) : 235 MPa Mutu baja (Mid Steel = BjTP 24) : 235 MPa
7 7
Mutu baja (High Yield = BjTS 40) : 390 MPa Mutu baja (High Yield = BjTS 40) : 390 MPa
8 Batas pergerakan joint (siar) : 8 Batas pergerakan joint (siar) :
9 Batas layan : 9 Batas layan :
10 Batas settlement : 200 mm 10 Batas settlement : 200 mm
Batas kemampuan bearing (shear
11 Batas kemampuan bearing : 11 : 1000 kN
bearing)
fs (for shaft friction in all cases) 1.50 1.50
: fs (for shaft friction in all cases) :
fb (for base resistance under non- fb (for base resistance under non-
12 : 3.00 12 : 3.00
seismic loading) seismic loading)
fb (for base resistance under fb (for base resistance under
: 1.5 : 1.5
seismic loading) seismic loading)