1) Press the STOP button and wait for current/voltage to reach 0 to power off feeding. Turn off non-fuse breakers on all converter units.
2) Confirm power is off, discharge cable by pressing 10kohm and short buttons, open high voltage cover, and open cable head per Figure 1.
3) Confirm power is off, discharge cable if needed, open high voltage cover, and short cable head per Figure 1.
4) The document outlines alarm indications that could occur during different operations when power is stopped, non-fuse breakers are turned off, or the high voltage cover is opened.
1) Press the STOP button and wait for current/voltage to reach 0 to power off feeding. Turn off non-fuse breakers on all converter units.
2) Confirm power is off, discharge cable by pressing 10kohm and short buttons, open high voltage cover, and open cable head per Figure 1.
3) Confirm power is off, discharge cable if needed, open high voltage cover, and short cable head per Figure 1.
4) The document outlines alarm indications that could occur during different operations when power is stopped, non-fuse breakers are turned off, or the high voltage cover is opened.
1) Press the STOP button and wait for current/voltage to reach 0 to power off feeding. Turn off non-fuse breakers on all converter units.
2) Confirm power is off, discharge cable by pressing 10kohm and short buttons, open high voltage cover, and open cable head per Figure 1.
3) Confirm power is off, discharge cable if needed, open high voltage cover, and short cable head per Figure 1.
4) The document outlines alarm indications that could occur during different operations when power is stopped, non-fuse breakers are turned off, or the high voltage cover is opened.
1) Press “STOP” button on OPERATION unit and wait for Power feeding current/voltage ramp down to 0. 2) NFB OFF on all CONV unit. 2. Cable Head open 1) Confirm Power feeding OFF. 2) Discharge cable by pressing “10kohms” button on EARTH TEST unit and waiting about 1minute, then press “SHORT” button and “RELEASE” button. 3) Open HV cover from SW unit. 4) Make open condition in accordance with Fig.-1. 3. Cable Head short 1) Confirm Power feeding OFF. 2) Discharge cable if required. 3) Open HV cover from SW unit. 4) Make short condition in accordance with FIG.-1. 4. Alarm indication during operation No Operation PFE Alarm EMS Display 1 Power feeding stop No alarm No alarm 2 CONV NFB OFF NFB Non Fuse Breaker Trip 3 HV Cover Open HC HV Cover Open Fig.-1 Setting of SW unit