Signaling Lights
Part Number Selection
Part Number
Blade Coil Voltage Code
Contact Model PCB Terminal
Terminal (Standard Stock in bold)
Timers
AC6V, AC12V, AC24V, AC110-120V,
With Check Button RH2B-UC 0 — AC220-240V
DC6V, DC12V, DC24V, DC48V, DC100-110V
With Indicator and Check Button RH2B-ULC 0 —
Top Bracket Mounting RH2B-UT 0 —
With Diode (DC coil only) RH2B-UD 0 RH2V2-UD 0
DC6V, DC12V, DC24V, DC48V, DC100-110V
With Indicator and Diode (DC coil only) RH2B-ULD 0 RH2V2-ULD 0
Standard RH3B-U 0 RH3V2-U 0
3PDT
Contactors
With Indicator RH3B-UL 0 RH3V2-UL 0
AC6V, AC12V, AC24V, AC110V, AC120V,
With Check Button RH3B-UC 0 — AC220V, AC240V DC6V, DC12V, DC24V,
DC48V, DC110V
With Indicator and Check Button RH3B-ULC 0 —
Top Bracket Mounting RH3B-UT 0 —
With Diode (DC coil only) RH3B-UD 0 —
DC6V, DC12V, DC24V, DC48V, DC110V
With Indicator and Diode (DC coil only) RH3B-ULD 0 —
Standard RH4B-U 0 RH4V2-U 0
Terminal Blocks
4PDT
With Indicator RH4B-UL 0 RH4V2-UL 0
AC6V, AC12V, AC24V, AC110V, AC120V,
With Check Button RH4B-UC 0 — AC220V, AC240V DC6V, DC12V, DC24V, DC48V,
DC110V
With Indicator and Check Button RH4B-ULC 0 —
Top Bracket Mounting RH4B-UT 0 —
With Diode (DC coil only) RH4B-UD 0 RH4V2-UD 0
DC6V, DC12V, DC24V, DC48V, DC110V
With Indicator and Diode (DC coil only) RH4B-ULD 0 —
Circuit Breakers
PCB terminal relays are designed to mount directly to a circuit board without any socket.
Ordering Information
When ordering, specify the Part No. and coil voltage code:
(example) RH3B-U AC120V
Part No. Coil Voltage Code
1705151135
800-262-IDEC (4332) • USA & Canada 873
RH Relays & Sockets
Relays Standard DIN Rail Mount 1 Finger-safe DIN Rail Mount 1 Through Panel Mount PCB Mount
RH1B SH1B-05 SH1B-O5C SH1B-51 SH1B-62
RH2B SH2B-05 SH2B-05C SH2B-51 SH2B-62 1. DIN Rail mount
socket comes with
RH3B SH3B-05 SH3B-05C SH3B-51 SH3B-62 two horseshoe
clips. Do not use
RH4B SH4B-05 SH4B-05C SH4B-51 SH4B-62 unless you plan to
insert pullover wire
spring. Replacement
horseshoe clip part
number is Y778-011.
Signaling Lights
Leaf Spring (side latch) RH1B, RH2B, RH3B, RH4B SFA-202 3 SFA-302 3
Leaf Spring (top latch) RH1B, RH2B, RH3B, RH4B SFA-101 3 SFA-301 3
AC Coil Ratings
Rated Current (mA) ±15% at 20°C Coil Resistance (Ω) Operation Characteristics
Timers
DC Coil Ratings
Terminal Blocks
BOLD.
100-110 — 8.2-9.0 — — — 12,250 — —
110 8 — 12.8 15 13,800 — 8,600 7,340
Signaling Lights
1650VA 1100VA
3PDT 10A 220 AC 7.5A 5A
300W 225W Horse-
4PDT
30 DC 10A 7.5A Resistive General Use power
Note: Inductive load for the rated load — cos ø = 0.3, L/R = 7 ms Voltage Rating
RH1 RH2 RH3 RH4 RH1 RH2 RH3 RH4 RH1, 2, 3
240V AC 10A 10A — 7.5A 7A 7A 7A 5A 1/3 HP
TÜV Ratings 120V AC 10A 10A 10A 10A 7.5A 7.5A — 7.5A 1/6 HP
Voltage RH1 RH2 RH3 RH4 30V DC 10A 10A 10A 10A 7A 7.5A — — —
Socket Specifications
Sockets Terminal Electrical Rating Wire Size Torque
(Coil) M3 screws 5.5 - 9 in•lbs
SH1B-05 250V, 10A Maximum up to 2–#12AWG
DIN Rail (contact) M3.5 screws with captive wire clamp 9 - 11.5 in•lbs
Timers
Mount SH2B-05
Sockets SH3B-05 M3.5 screws with captive wire clamp 300V, 10A Maximum up to 2–#12AWG 9 - 11.5 in•lbs
SH4B-05
(coil) M3 screws 5.5 - 9 in•lbs
SH1B-05C 250V, 10A Maximum up to 2–#12AWG
Finger-safe (contact) M3.5 screws with captive wire clamp, fingersafe 9 - 11.5 in•lbs
DIN Rail SH2B-05C
Mount SH3B-05C M3.5 screws with captive wire clamp, fingersafe 300V, 10A Maximum up to 2–#12AWG 9 - 11.5 in•lbs
SH4B-05C
Through SH1B-51
Contactors
Panel SH2B-51
Solder 300V, 10A — —
Mount SH3B-51
Socket SH4B-51
SH1B-62 PCB mount 250V, 10A — —
PCB Mount SH2B-62
Socket SH3B-62 PCB mount 300V, 10A — —
SH4B-62
Replacement
DIN mount sockets and hold For use on DIN rail mount socket when using pullover wire hold down
Hold-Down Y778-011
down springs. spring. 2 pieces included with each socket.
Spring Anchor
1705151135
800-262-IDEC (4332) • USA & Canada 875
RH Relays & Sockets
Specifications
Switches & Pilot Lights
Release Time 2
3PDT
25ms maximum
4PDT
SPDT AC: 1.1VA (50Hz), 1VA (60Hz) DC: 0.8W
Power Consumption DPDT AC: 1.4VA (50Hz), 1.2VA (60Hz) DC: 0.9W
(approx.) 3PDT AC: 2VA (50Hz), 1.7VA (60Hz) DC: 1.5W
4PDT AC: 2.5VA (50Hz), 2VA (60Hz) DC: 1.5W
Insulation Resistance 100MΩ minimum (500V DC megger)
Relays & Sockets
SPDT
Operating DPDT
–25 to +70°C (no freezing)
Temperature 4 3PDT
4PDT
Operating Humidity 45 to 85% RH (no condensation)
Weight (approx.) SPDT: 24g, DPDT: 37g, 3PDT: 50g, 4PDT: 74g
30V DC resistive
100
Signaling Lights
100
50 50
100V DC resistive
30V DC inductive
20 20
240V AC inductive 240V AC resistive
120V AC inductive 100V DC inductive
10 10
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
Load Current (A) Load Current (A)
100 100
20 20
Timers
10 10
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
Load Current (A) Load Current (A)
120V AC resistive
30V DC resistive
500 500
Life (X 10,000 operations)
30V DC inductive
Life (x 10,000 operations)
Contactors
100 100
50 50
20 20 100V DC resistive
240V AC inductive
240V AC resistive 100V DC inductive
120V AC inductive
10
10 1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Load Current (A) Load Current (A)
DC resistive
Load Current (A)
DC resistive
1.0 1.0
DC inductive
0.1 0.1
1 5 10 50 100 200 300 1 5 10 50 100 200 300
Load Voltage (V) Load Voltage (V)
1705151135
800-262-IDEC (4332) • USA & Canada 877
RH Relays & Sockets
Continuous Load Current vs. Operating Temperature Curve (Basic Type, With Check Button, and Top Bracket Mounting Type)
Switches & Pilot Lights
(RH1) Note: The rated voltage is (RH2) Note: The rated voltage is (RH3/RH4) Note: The rated voltage is
applied to the coil. applied to the coil. applied to the coil.
100 100 100
90 90 90
80 80
Operating Temperature (˚C)
80
10 10 10
0 0 0
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
Load Current (A) Load Current (A) Load Current (A)
Internal Connection (View from Bottom)
Basic Type
SPDT DPDT 3PDT 4PDT With Check Button
Front
1 2 3 4 Pushbutton
Relays & Sockets
5 6 7 8
9 10 11 12
Contacts can be operated by pressing the
13 (–) (+) 14 check button.
1 1 2 4 1 2 3 4 1 4
5 5 6 8 When the relay is energized,
5 6 7 8 5 8
Below 9 9 10 12
Below 9 12 the indicator goes on.
9 10 11 12
100V 13 14 13 ( – ) ( + )14
24V AC/ • Relay coils less than
(–) (+) 13( – ) ( + )14 13( – ) ( + )14
AC/DC DC 100V DC do not contain a
Timers
1
1 4
5
5 8
9 Below
Below 9 12
13 14 24V AC/
100V DC (–) (+) 13( – ) ( + )14
DC
Contains an LED indicator and
a surge absorber, and has the
same height as the basic type.
Signaling Lights
1
1 4
LED color of DPDT model is
5
5 8 green.
9 24V AC/
100V DC 9 12
13 ( – ) 14( + ) DC and
and over
over
13 14
(–) (+)
Dimensions (mm)
RH1B-U/RH1B-UL/RH1B-UD/RH1B-ULD RH2B-U/RH2B-UL/RH2B-UD/RH2B-ULD RH3B-U/RH3B-UL/RH3B-UD/RH3B-ULD
ø2.6 hole
ø2.6 hole
4.7
1
ø2.6 hole
4.7
5
1 4
9
27.5
5 8
0.5
0.5
27.5
13 14 9 12
13 14 1 2 4
5 6 8
5.4 14
27.5
0.5
9 10 11
Timers
35.6 max. 6.4 13 14
Dimensions in the ( )
10
include a hold-down spring.
ø2.6 hole
0.5
4.7
ø2.6 hole
Contactors
4.7
4.7
0.5
1
5
1 4
5.9
43.2
27.5
9
38
5 8
5.9
43.2
27.5
38
13 14
9 12
ø2.6 hole 13 14
6.6
7.25
3.5 2 5.4
4.7
9 10 11 12
0.5
13 14
Terminal Blocks
RH3B-UT RH4B-UT
10
10
4.7
10
10
10
2 3.5
0.5
4.7
ø2.6 hole
0.5
4.7
Circuit Breakers
1 2 4
1 2 3 4
5.9
5 6 8
43.2
38
28
5.9
5 6 7 8
9 10 12
28
38
44
13 14 9 10 11 12
13 14
7.25
7.25
1705151135
800-262-IDEC (4332) • USA & Canada 879
RH Relays & Sockets
RH1V2-U/RH1V2-UD RH2V2-U/RH2V2-UL/RH2V2-UD
8-ø2.4 holes
0.5
4.7
3-ø2.4 holes
2-ø2 holes
7.25
0.5
1.5
4.7
0.5
2
7.15
0.5
1
13.15
5
7.8
1 4
27.5
9
12.5
0.5
5 8
27.5
6.6
13 14
9 12
13 14
5
35.6 max. 4.6 14 10
2
Signaling Lights
RH3V2-U/RH3V2-UL/RH3V2-D RH4V2-U/RH4V2-UL/RH4V2-UD
30
11-ø2.4 holes 10 10
4.7
14-ø2.4 holes 10
4.7
2
13.15
1 2 4
13.15
7.8
5 6 8
7.8
1 2 3 4
27.5
Relays & Sockets
9 10 11 5 6 7 8
0.5
27.5
9 10 11 12
0.5
13 14
13 14
7.25
7.25
0.5 31
0.5 41
35.6 max. 4.6
35.6 max. 4.6
1
4.2
4 1
4.2
16
67
47
26
67
47
2.5
30 25 ø3.6 min.
7.9 max. 5.9 max.
SH3B-05 SH4B-05
31.5 31.5
32 42
8 18 DIN Rail 8 18 DIN Rail
M3.5 Terminal Terminal Arrangement M3.5 Terminal Terminal Arrangement
(BNDN) (BNDN)
Screw Screw
2-ø4.2 Mounting Holes 2-ø4.2 Mounting Holes
8 6 5 8 7 6 5
(or M4 Tapped Holes) (or M4 Tapped Holes)
4.2
4 3 2 1
4.2
4 2 1
46
67
47
67
47
36
12 10 9
(Top View)
(Top View) 46 14.5
36 14.5 7.9 max.
7.9 max. 50 25 ø3.6 min.
2.5
2.5
40 25 ø3.6 min.
Circuit Breakers
4.2
4.2
49
69
26
46
64
26
14 13
14 13
Signaling Lights
12 9
12 11 10 9
Ring terminals (Top View) 18.7 Ring terminals (Top View)
26
cannot be used. cannot be used.
1.7
26 18.2 30 29.5
1.6
29
2
SH3B-05C SH4B-05C
32 When using
M3.5 Terminal 36 42 BAA/BAP: 33
7 Screw DIN Rail
25 Terminal Arrangement 7 25
(BNDN)
DIN Rail
8 6 5 (BAA/BAP) Terminal Arrangement
ø5 2-ø4.2 Mounting Holes
4 2 1
(or M4 Tapped Holes) ø5 2-ø4.2 Mounting Holes 8 7 6 5
4.2
4.2
49
69
36
49
69
14 13 46
12 10 9
14 13
36 18.7
cannot be used. Ring type crimping (Top View)
1.7
Timers
Contactors
SH3B-51 SH4B-51
Terminal Blocks
Circuit Breakers
1705151135
800-262-IDEC (4332) • USA & Canada 881
RH Relays & Sockets
6.95
1 4.4
5.65
5 5 8 10
25.4
4.7
25.4
29
4.7
9 12
31
9
13 14 13 14
11.85
0.3
21.2 3 (Bottom View)
0.3
18
12.5
3 (Bottom View)
11
5.95
11
31 min.*
6.6
2-ø2 holes
29 min.*
15 8-ø2.4 holes
15
Signaling Lights
2
1.5 (Tolerance ±0.1) 2
* 36 min. when using * 34 min. when using (Tolerance 0.1)
12.2 hold-down springs hold-down springs
SH3B-62 SH4B-62
Terminal Arrangement 36 min. Terminal Arrangement 6.85 45 min.
7.35 21.3 1 2 3 4 31.3
1 2 4
6.65
5 6 8 10 10 5 6 7 8 10 10 10
25.4
4.7
31
25.4
4.7
9 10 11 12
31
9 10 12
13 14
13 14
0.3
45 3 (Bottom View)
0.3
36 3 (Bottom View)
6.65
12.5
12.5
Relays & Sockets
11
11
15
6.6
6.6
31 min.*
31 min.*
15 14-ø2.4 holes
11-ø2.4 holes
2
2 39.2 * 36 min. when using
hold-down springs (Tolerance 0.1)
30.2 * 36 min. when using (Tolerance 0.1)
hold-down springs
Timers
Contactors
Terminal Blocks
Circuit Breakers
Authorized Distributor
IDEC:
RH2B-ULD-DC24V RH1B-ULD-DC24V RH3B-UDC24V RH1B-UAC24V RH1B-UCDC24V RH3B-ULCDC110V
RH4B-ULCAC12V RH2B-UAC220-240V RH1B-ULCAC240V RH1B-UTDC24V RH1B-UTAC12V RH2B-ULAC220-
240V RH3B-UTAC240V RH2B-UAC110-120V RH4B-UAC6V RH2V2-ULAC110-120V RH2B-ULDC48V RH1V2-
UDC6V RH4B-ULAC24V RH1V2-UAC24V RH2B-UAC24V RH3V2-UAC120V RH2V2-UAC110-120V RH3B-
ULDC24V RH1V2-UDC24V RH3V2-UAC12V RH4B-UTAC24V RH2B-UTAC110-120V RH3B-UCDC24V RH1B-
UTAC120V RH3B-ULDC6V RH4B-UDC12V RH4V2-UAC220V RH2B-UTDC100-110V RH1B-UAC6V RH4B-
ULCDC12V RH4B-UAC24V SH2B-05C RH2B-UDC6V RH3B-UDC6V RH2B-ULCDC24V RH3B-ULCDC12V RH3B-
ULAC24V RH3V2-UDC110V RH2B-UTDC24V RH3B-ULDC110V RH2V2-UAC6V RH4V2-UAC6V RH3B-
ULCAC240V RH4V2-ULDC12V RH1B-UCDC6V RH3V2-UDC24V RH1B-ULCAC120V RH4V2-ULAC24V RH4B-
UDC24V RH1B-ULAC24V RH1B-UAC110V RH3V2-UAC24V RH1B-UTAC24V RH3B-UTDC12V RH1B-ULAC110V
RH3B-UTAC120V RH2V2-UAC220-240V RH4B-UCDC6V RH4B-ULCAC24V RH4B-UTAC120V RH3B-UDC12V
RH2V2-UDC48V RH2B-UCDC48V RH2V2-ULAC220-240V RH2B-ULCDC48V RH4V2-UDC12V RH3V2-UDC6V
RH4B-UTDC6V RH1B-ULDC24V RH4B-UCAC12V RH2B-UCDC6V RH3B-UCAC240V SH1B-62 RH3B-UCAC120V
RH2V2-ULDC12V RH3B-UCDC110V RH1B-UDC24V RH1V2-UAC120V RH4V2-UDC48V RH1B-UAC220V
RH2V2-UDC24V RH2B-UCAC220-240V SH2B-51 RH3B-UAC110V RH3B-ULAC220V RH2B-UTAC6V RH2B-
ULCAC12V RH3V2-UAC6V RH4B-ULAC120V RH1B-ULDC48V RH1B-ULCAC12V RH2B-UCAC110-120V RH1V2-
UDC110V RH2B-ULCDC6V