The document is an electrical design check list used to review electrical plans and ensure they meet specifications. It contains 41 items across various sections of an electrical design that are checked for accuracy and code compliance, including specifications, diagrams, layouts, load calculations, and PDF output. Designers and reviewers use the checklist to identify any mistakes or issues in the electrical design.
The document is an electrical design check list used to review electrical plans and ensure they meet specifications. It contains 41 items across various sections of an electrical design that are checked for accuracy and code compliance, including specifications, diagrams, layouts, load calculations, and PDF output. Designers and reviewers use the checklist to identify any mistakes or issues in the electrical design.
The document is an electrical design check list used to review electrical plans and ensure they meet specifications. It contains 41 items across various sections of an electrical design that are checked for accuracy and code compliance, including specifications, diagrams, layouts, load calculations, and PDF output. Designers and reviewers use the checklist to identify any mistakes or issues in the electrical design.
Designed by: Date Finished Checking: Items 1st Check 2nd Check Remarks Parts of Electrical Design Specification/General Notes 1 Is the specification notes correct and accurate? Legends 2 Are the legends specified? One Line Diagram 3 Are/Is the one line diagram specified? 4 Is the size of wire shown correct? 5 Is the circuit breaker rating correct? 6 Is the type of breaker specified? Design Analysis 7 Are/Is the design analysis specified? 8 Is the calculation correct? 9 Is the recommended size of wire and conduit correct? Riser Diagram (if 2 storey or more) 10 Is the riser diagram specified? 11 Is the size of wire correct? 12 Are/Is the distance/s of the panel boards from floor indicated? 13 Are/Is the distance/s of the panel boards from floor indicated correct? 14 Is the scale indicated? Lighting Lay out 15 Are/Is the lighting layout/s indicated? 16 Does the legends correspond to the lighting lay out? 17 Are/Is the lighting layout/s readable? 18 Are the circuit breakers number specified? 19 If the proposed building has 2 or more storey, is it specified in the lighting lay out? Power Lay out 20 Are/Is the powerlayout/s indicated? 21 Does the legends correspond to the power lay out? 22 Are/Is the power layout/s readable? 23 Are the circuit breakers number specified? 24 Are the circuit breakers for ACU, motors and heating elements have different legends from other C.O.'s? 25 Are the panel boards specified? 26 If the proposed building has 2 or more storey, is it specified in the power lay out? Schedule of Loads 27 Is the format presentable and easy to understand? 28 Is the total no. of circuit breakers the same with the overall total no. of the circuit breakers indicated in the lighting and power layout? 29 Are the load descriptions accurate? 30 Is the no. of outlets the same with no. of outlets indicated in the power layout? 31 Is the no. of switches with the no. of switches indicated in the lighting layout? 32 Is the VA (volt-ampere) calculation correct? 33 Is the A (current) calculation correct? 34 Is the conductor size & type + equipment grounding conductor recommended correct? 35 Is the voltage drop calculation correct and acceptable to the 5% limit? 36 Is the Short Circuit calculation/KAIC rating correct? 37 Is the distance from the main source indicated? PDF Output Template 38 Is the plate template of the approved format? 39 Are the contents of the sheet specified? 40 Is the Plate number correct? Ex. E (for electrical plan) 1/2 (page 1 out of 2) 41 Is the proper Placement of parts correct/presentable? Ex. General notes on the top left corner of the plate 42 Is the pdf output properly plotted? (fits the size of a paper) OTHERS TOTAL