Start
(0.3) No
Test Step 7.
Perform A
Associated Yes Results in Yes Yes Stationary
trouble 3473-31 code Regeneration.
acceptable
code present? present? Claim code
range?
108F-515
No No No (1.0)
Yes No
Branch to
procedure from table Regen OK?
lookup in Test
Step 3.
Result
Yes acceptable; No
have 3474-31
code?
Test Step 9.
Perform data log. Contact Technical
(0.6) STOP
Claim code Communicator.
108S-535
6/15/09
ARD Ignition – Test RENR9343-06
Start
Refer to
Test steps 1,2, and 3. Yes Troubleshooting,
Claim code 3556-31 code? “Combustion
(1550-535) (ARD) Nozzle -
Test”.
(0.4) No
No No
3484-5 code?
Yes Refer to
Troubleshooting,
4077-17 code?
Yes “Fuel System
Pressure - Test”.
Test Step 8.
Check the Wiring No
for an Open
Circuit.
Claim code (0.2)
(1555-040-VW)
Refer to
Yes Troubleshooting,
3832-17 code? “(ARD)
Combustion
No Air - Test”.
3484-6 code?
No
Yes
Test Step 9.
Yes Refer to
Check the Wiring (0.1) 520192-15 or Troubleshooting,
for a Short Circuit. 520192-16 “Clean Gas
Claim code code? Induction - Test”.
(1408-535-SHR)
No
Test Step 4.
Check the
Combustion Head
(ARD).
Claim code
(108M-535)
(0.1)
(0.1) Test Step 7.
Clean the
No Yes Components in the
Sparks (ARD) Combustion
3473-31 code? appear? Head.
Claim code
(108M-070-IC)
Yes No
(0.1 - 0.2)
Test Step 6. Test Step 10.
Test Step 5. Check for Spark Check the (ARD)
Check for Voltage
(0.1)
Voltage at the Combustion Head
at the Spark Plug. Ignition Coil for Proper STOP
Claim code Output. Operation.
(1555-535) (0.1) Claim code (0.2) Claim code
(1554-535) (108B-535)
6/15/2009
ARD Fuel System Pressure – Test RENR9343-06
Start
Table lookup.
No No
(0.4)
Refer to
Yes Test Step 4. Yes Test Step 12,
Faulty
Procedure B. Procedure K.
Procedure B? component
Claim code
identified?
1250-038-ZPB
No
(0.1) No
No No
(0.4 - 0.5)
No No
(1.0 – 1.1)
Refer to
Test Step 12,
Yes Procedure K.
Test Step 7. Faulty Yes
Procedure E? Procedure E. component
1250-038-ZPE identified?
No No
(1.7 – 1.8)
Refer to
1 2 3
Test Step 12,
Procedure K.
6/15/2009
1
Yes Yes
Test Step 8.
Faulty
Procedure F.
Procedure F? component
Claim code
identified?
1250-038-ZPF
No No
(0.1)
No (0.1) No
No No
(0.2 - 0.5 - 0.6)
Refer to
Test Step 12,
Procedure K.
(0.7 - 0.9)
( 0.9)
3
STOP
6/15/2009
Clean Gas Induction – Test RENR9343-06
Start
Test step 1.
Claim code
1080-535
(0.3)
Table lookup.
No
No
Test Step 5.
Procedure D.
Stop
Claim code
1080-038-ZPD (0.3)
6/15/09