You are on page 1of 6
(§INDKOM COMPACT SUBSTATION UNIT -SCADA EQUIPPED QUALITY PRODUCTS EXCELLENT SERVICES COMPETITIVE PRICE ON-TIME DELIVERY * ¥ Se (le Engineering Sdn Bhd us| “Ee ty = ova INDEOM Engi ‘An ISO 9001 compar Ne eee ee Compact Substation Unit - SCADA EQUIPPED Application The Indkom Compact Substation Unit SCADA-Equipped (CSU - SE) is a ground bate installation suited for urban areas with limited spaces. CSU-SE provides a safe and easy access for authorized personne|, encompasses an all-around protection and access deterrence for the general public in proximity of the unit. Through an installed on board SCADA equipment, the CSU-SE transmits telemetric data using a modulator/demodulator (Modem) to Control Centre using ‘commands from the master supervisory system. Through this connection, control is established on the equipment and data transfer within the CSU-SE intemal network. The CSU-SE is designed fo withstand the surrounding temperature, humidity, rain, solar radiation and cendensation. The CSU-SE is entirely factory-prefabricated and tested, making on-site installation site simple, fast and practically maintenance free. Customized Designs Solution CSU-SE can be customized ond adopted to multiple sizes and configurations to fulfil the ‘customer's requirements. Design and Structure Benefits Indkom CSU-SE innovative design for —_* Suitable for outdoor and indoor installations; SOOKVA/IOO0KVA model is certified in © Free-standing, compact and ready for use: accordance with IEC 60529, 6271-202, * Unique design with reliable performances 60076, 1439 to ensure a safe and reliable design output and equipped with: and added safety features. Enclosure + Metal enclosure with compartments + TIKV SF6 insulated Ring Main Unit (RMU} for connection to the 11kW network and also for the protection of the medium ‘and low voltage (MV/LV) transformers Fully shrouded LV switchboard MV/LV connections 11/0.433 kV Transformer Supervisory Control and Data Acquisition (SCADA) panel The roof of the substations is removable and extendable up fo one meter to provide ‘overhead protection. Ventilation apertures ‘ore also incorporated into the structure to enable natural ventilation. All doors of the substation uiilze a three-point linkage controlled by a stainless steel weather-proof handle padlock facilifies. The RMU is connected directly to the distribution transformer through single core XLPE cables for easier and faster installation: and separable elbow connectors are used for termination. As for connection of DIN LV distribution board, it is coupled to the distribution transformer through insulated busbars. The CSU-SE distiibution compact substation’s enclosure is completely prefabricated for installation on a concrete base. With an Ingress protection of IPS, it has following features: «Base made of hotdipped galvanized C-channel steel to ensure rigidity for easy transportation and installation. + Galvanised Iren sheet metal for the overall body in 3 mm thickness coated with epoxy powder and ant-stick finishing, «Floor plating to. intemal environment. ensure vermin-proof CSU S500KVA & 1000kVA Material Type Galvanized Iron Sheet Body — [Thickness omm Finishing Anti-Stick/Epoxy Powder Coating Enclosure Material Type Steel C-Channel Characteristics Base _| Section ‘50mm x 10omm Finishing Hot-Dipped Galvanized Ingress Protection 1P35, IEC 60529, Fully Weather and Vermin Proof Construction Internal bolting and welded Type Hermetically Sealed HV- Elbow connector Silicone rubber Terminations (DIN specs), LV - Direct busbars Transformer Standard IEC 60076 ‘Capacities (kVA) 500, 1000 Voltage (kV) T1/O-433KV. Type Ring Main Unit (RMU) Insulation SF6 Gas T-Switch Fused ; Sfandards TEC 62271, 60282, 60376 Medium Voltage [Rated Voltage (KV) 12 Switchgear Rated | Ring Feeder 630 Curent [7x Feeder 630. Fuse holders able to accomodate (A) Current limiting fuses up to 200A Type Fused, with link for Incoming Unit, DIN Type. Standards TEC 43623 (Outgoing Fuse Uni) Busbor Rating 1600A (1000kVA), 800A (S00KVA) ‘Outgoing ways 10 ways, 400A (1000kVA) 6 ways, 400A (SOOKVA)| Low Voltage Fuse NH2, DIN type Distribution 3x Current Transformers, Class 1.0, 7.5VA Board ; ; 3x Ammeter With Max Demand Indicators Metering Equipment Power Factor Meter Socket Outlet and lighting SECONDARY PANEL Material Type Galvanized Iron Sheet Body [Dimension 1670 x 800 x 500 (mm) Enclosure Finishing “Anii-Stick/Epoxy Powder Coating Characteristics Ingress Protection 1P54, IEC 60529. Fully Weather and Vermin Proof, Construction Tnfemal bolting and welded Special Features Sliding ROOF Remote Control Box | Type 7&1 Feeder - Control & Indication Remote Type 1 DO, 1DI & 1 CPU Card Terminal Unit 1 Master, 1 Diagnostic & 1 Link Port Earth Fault Type T Display Unit for Earth Fault, 1 SE Type Sensor for Indicator detecting Earth Fault (2 units) AVC Charger | ChargerType 2AVDC- 10A with Batiery Battery Type 2x 12V, 45AH Lead Acid Maintenance Free Utilizing the latest SCADA functions through the use of a remote terminal unit, INDKOM CSU-SE is able to remotely switch its Ring Main Unit and provide data collection off site using an internet linked software interface. A hard point switching is still provided to ensure redundancy in the system. The SCADA panel is provided with a DC Charger and dual 12V DC battery with the ability fo maintain a stable 10-hour normal operation independent of the main phase supply. Ingress protection is rated at IP54, Technical Drawings = 1 | f= | = a8 bed ie 3 i 2 8 q th oe FRONT VIEW we ron wv cane 200 pe Single Line Diagram for CSU SCADA 1000kVA Transformer MV Ring Main Unit & LV Distribution Board Transformer The distribution transformer consists of @ hermetically sealed oil filled tank, solid porcelain bushings for HV/LV connection, fitted with overpressure relief device. Offload tap changer and Earthing terminal MV Ring Main Unit (Motorized) The Indkom CSU SE distribution compact substation utiizes a medium voltage ring main unit (MV RMU) for jis electrical connection. Filed with SF6 gas and sealed permanentiy, the switchgear and busbar: assembly is enclosed in a totally welded gas-tight stainless steel enclosure. The performance obtained meets the IEC stondord of “Sealed Pressure System”. The RMU is equipped with a gas pressure indicator with readings independent of the ambient temperature. The 11kV MY RMU uses fwe load break and one fuse switeh. A separate control box is provided to allow closed accessed control as a safety precaution during maintenance Switching mechanisms ore motorized and can be manipulated through @ fullly enclosed unified control panel. Hard point switching apparatus are provided for redundancy. LV Distribution Board The LY board are equipped with DIN-+type disconnecter switches which care fully shrouded and manufactured in gecordance with DIN 43423 standards. Neutral lsolators are provided for added safety during maintenance operations. Disconnector switches are rated to provide an Ingress Protection of IP2X. Lot 2, Jalan Asam Jawa 16/15, Off Persiaran Kemajuan, Seksyen 16, Kawasan Perindustrian Shah Alam, 40200 Shah Alam, Selangor Darul Ehsan, Malaysia. Phone : +603 5543 2388 Fax : +603 5543 2377 E-mail : info@indkom.com.my Website : wonw:indkom.commy (amember of the INDKOM Group of Companies) ‘As standards, application and design may change fiom time to time, ‘please contact us for updates and technical information

You might also like