ISO 9001 ISO 14001 KOTRA

Certificate Certificate “Seal of Excellence”

The Next Generation of Elevator

Your Elevator Partner


www.sigmaelevator.com

SIGMA constantly endeavors to improve products so that information in this catalog is subject to change without notice.
2010.5 Printed in Korea / Revision No. 0
Elevator Company

The Global Leader of the Elevator Industry

P03 SIGMA History

P04 SIGMA Global Network

P06 Next Generation of Elevator

P08 Advanced Technology

P10 Leading to a Green Future

P12 Space Saving

P14 Modern & Universal Design


P03 SIGMA History P04 SIGMA Global Network P06 Next Generation of Elevator P08 Advanced Technology P10 Leading to a Green Future P12 Space Saving P14 Modern & Universal Design

History
1968 Started Korea’s first elevator company
1985 Began production of gearless elevators (DC control)
1987 Developed VVVF controlled elevators
1989 Installed new elevator test tower (114m, Changwon Factory)
1992 Acquired ISO 9001 Certificate
1993 Produced VVVF controlled gearless elevators (up to 420m/min)
1996 Acquired ISO 14001 Certificate
1997 Established second factory in Dalian, China to meet demand in the
Chinese market
1998 Produced 100,000 units of elevators and escalators
2001 SIGMA brand established for overseas marketing
2005 Achieved 100 million USD in overseas contracts
2006 Exported 53,715 units to 75 countries
2008 Achieved 200 million USD in overseas contracts
2009 Obtained KOTRA Seal of Excellence

MUSE_03
P03 SIGMA History P04 SIGMA Global Network P06 Next Generation of Elevator P08 Advanced Technology P10 Leading to a Green Future P12 Space Saving P14 Modern & Universal Design

SIGMA is an overseas brand from Korea,and exports to over 75 countries worldwide.

SIGMA works for the whole world


Global Network
★ Headquarter (1 country) Factory (2 countries)
● SIGMA Distributor (75 countries) ● Sigma Subsidiaries (5 countries)

� Bulgaria � Macedonia � Thailand


� Czech � Albania � Malaysia
� Slovakia � Romania � Singapore
� Slovenia � Moldova � Vietnam
� Hungary � Ukraine � Hong Kong
� Croatia � Lithuania � Georgia


Bosnia
Serbia


Latvia
Estonia

� � Armenia NORTH
� Azerbaijan
� Montenegro � Russia �

EUROPE

� Kazakhstan
AMERICA
� Uzbekistan
��

� �
ASIA � Turkmenistan �



��





Dalian


Pakistan
India
ATLANTIC

��
� �
★ Seoul � Bangladesh OCEAN
� �
Changwon � Myanmar CENTRAL
� � �


� �
� �


Philippines
Indonesia �
AMERICA
� �
� � �
� � � � � � Brunei � USA
� � � � Mongolia �
� � Dominican Republic
� China
� �
� Mexico
� � � Korea
� �
� Sri Lanka �
� Guatemala

� Syria � Libya AFRICA � � �


Panama
Venezuela
� Iraq � Algeria �

� Kuwait � Tunisia �
PACIFIC �
SOUTH � Colombia
� Bahrain � Morocco OCEAN AMERICA
� Ecuador
� Qatar � South Africa INDIAN � Peru
� Lebanon � Zambia,
� Palestine � Madagascar �
OCEAN �
� Chile
� Brazil
� Jordan � Mauritius �
� � Uruguay
� Egypt � Ethiopia

� Saudi � Yemen OCEANIA �
� Argentina
� Nigeria � Oman �
� U.A.E �

Facilities Europe Middle East & Africa Asia North & South America
Headquarter: Seoul(Korea) Bulgaria, Czech, Slovakia, Slovenia, Hungary, Syria, Iraq, Kuwait, Bahrain, Qatar, Lebanon, Thailand, Malaysia, Singapore, Vietnam, Hong Kong, USA, Dominican Republic, Mexico, Guatemala,
F a c t o r y : Changwon(Korea), Dalian(China) Croatia, Bosnia, Serbia, Montenegro, Palestine, Jordan, Egypt, Saudi, Nigeria, Libya, Georgia, Armenia, Azerbaijan, Kazakhstan, Panama, Venezuela, Colombia, Ecuador, Peru,
Subsidiary: Hong Kong, Malaysia, Macedonia, Albania, Romania, Moldova, Algeria, Tunisia, Morocco, South Africa, Zambia, Uzbekistan, Turkmenistan, Pakistan, India, Chile, Brazil, Uruguay, Argentina
Singapore,Thailand, Vietnam Ukraine, Lithuania, Latvia, Estonia, Russia Madagascar, Mauritius, Ethiopia, Yemen, Oman, Bangladesh, Myanmar, Philippines, Indonesia,
U.A.E Brunei, Mongolia, China, Korea, Sri Lanka

MUSE_04 Changwon Factory Dalian Factory Borobiovy Triumph Palace Khalid Al Attar Tower Armada Tower MAG 218 Emerald Tower LG Beijing Tower Korea World Trade Plaza La Castellana Torre Global Waters Ocean Two MUSE_05
(Korea) (China) (Russia) (Russia) (UAE) (UAE) (UAE) (Kazakhstan) (China) Center (Korea) (Venezuela) Bank (Panama) (Panama) (Panama)
P03 SIGMA History 04 SIGMA Global Network P06 Next Generation of Elevator P08 Advanced Technology P10 Leading to a Green Future
P12 Space Saving P14 Modern & Universal Design

The coated steel reinforced belt:


technology that re-invents an industry

The Next Generation of Elevator

� �
20%
� Lighter

Flexible Steel Belts Reliable Controller


The polyurethane-coated flat steel belt is up to Designed for groups of up to four cars, the modular controller
20% lighter and lasts up to 3 times longer incorporates a new generation of printed circuits and software to
than conventional ropes. Its flexibility results provide optimal response time.
in a much smaller bending radius. The digital closed-loop variable frequency (VF) drive,
with vector control technology, further increases efficiency and
� accuracy, and a digital speed encoder ensures correct car speed
and positioning. The result is a system of exceptional reliability.
70%
Smaller

Compact Gearless Machine


More
A sheave has allowed SIGMA to design a Reliable
machine that is up to 70% smaller than
conventional ones

Lower
Cost

PULSE System

KEY COMPONENTS
Machine Roomless System PULSE System
� Flat, polyurethane-coated steel belts The compact MUSE gearless machine does not The PULSE electronic system continually monitors the status of the
� Gearless machine with PM synchronous motor require a machine room and can be easily belts’ steel cords. In contrast to visual inspections of conventional steel ropes,
positioned on the guide rails. This means all the PULSE system automatically detects and informs technicians of the
� Electronic system that monitors the integrity of the belt cords at all times bearing loads can be transferred to the pit, thus quality of the belt cord, thus eliminating downtime and greatly enhancing the
reducing structural building costs. reliability of the inspection.
� Closed-loop variable frequency control
MUSE_06 MUSE_07
P03 SIGMA History P04 SIGMA Global Network P06 Next Generation of Elevator P08 Advanced Technology P10 Leading to a Green Future P12 Space Saving P14 Modern & Universal Design

Advanced Technology
The passengers’ safety is of the utmost importance, so SIGMA maintains the
highest standards in safety technology. The flat belt technology used in the
MUSE represents a superior innovation in safety. MUSE’s flat belt system ensures your safety.

12 Times Safer Technology


Polyurethane-coated
flat steel belt The polyurethane coated belts improve safety by 12 times by
Width 30mm reducing the danger of abrasion found in existing rope-type
elevators.

12 ropes & Thickness Semi-permanent Lifetime


588 wires inside 3mm
The lifetime of polyurethane coated belts with a thickness of 3mm,
*Based on 32kN a width of 30mm, and 588 wires is three times longer than the
ropes used in existing systems which require periodic replacement
every 3 - 5 years.

PULSE System
The PULSE System electrically checks the abrasion status and
operating conditions in real-time to make maintenance more efficient
and easier.
Safety Factor 12 times
10 times

20% Lighter Belt


Weight Weighing 20% less than the steel ropes used in other elevators,
58 kg 44 kg the flat belt significantly reduces energy consumption.

12 mm
Thickness 3 mm

Life Cycle semi


3~5years perma-
nent

necessary
Lubrication unnece-
ssary

MUSE_08 MUSE_09
P03 SIGMA History P04 SIGMA Global Network P06 Next Generation of Elevator P08 Advanced Technology P10 Leading to a Green Future P12 Space Saving P14 Modern & Universal Design

Leading to a Green Future


MUSE makes our world better. MUSE realizes
sustainable growth, with low cost and high MUSE is an environmentally friendly next-generation elevator.
energy efficiency, by applying an environmentally
friendly and energy efficient system. And, MUSE Lubrication-Free
also provides a comfortable ride that no other Neither the belts nor the gearless machine with sealed-for-life bearings
system can offer. require any form of polluting lubricants. The need for oil in the
machine is eliminatd by the abscence of a gear box. Unlike steel
cables, the belts require no lurication.

A Soft and Quiet Ride


VVVF digital closed-loop drive minimizes internal vibration and the
flat belts eliminate the metallic rubbing noise that comes from the steel
ropes and sheaves found in other elevators.

30% Energy Saving System


The low-inertia gearless machine with a permanent magnet (PM)
synchronous motor means energy savings and reduced operating
costs.

MUSE reduces the energy consumption up to 30%


Category Conventional Elevator MUSE
PM (Permanent Magnet)
Machine Geared Machine
Gearless Machine
Energy Efficiency Geared (80%) Gearless (90%)
Power Consumption
47.7 kwh 34.3 kwh
(For 17-Passengers)

MUSE_10 MUSE_11
P03 SIGMA History P04 SIGMA Global Network P06 Next Generation of Elevator P08 Advanced Technology P10 Leading to a Green Future P12 Space Saving P14 Modern & Universal Design

Space Saving
SIGMA Elevator considered various ways to
help you maximize your utilization of space. MUSE gives you the space to design freely.
The MUSE system, which requires no
machine room, does just that, and benefits
Elevator with No Machine Room
everyone including landlords, tenants and
No machine room means that you can fully utilize your space and
architectural designers. MUSE allows you to ensures freedom in building design.
use your imagination to its fullest when
designing your space.

Time and Money Savings


Overall construction cost and period can be reduced because time and
money do not have to be spent building a machine room.

Simple and Easy Maintenance


All maintenance is carried out through the E&I (Emergency &
Inspection) Panel. Located on the top or second top floor, the E&I Panel
can be surface mounted. The E&I Panel is available in a range of
finishes to harmonize with various door finishes.

MUSE_12 MUSE_13
P03 SIGMA History P04 SIGMA Global Network P 06 Next Generation of Elevatorr P08 Advanced Technology P10 Leading to a Green Future P12 Space Saving P14 Modern & Universal Design

Modern & Universal Design


SIGMA Elevator’s ‘Design Center’ is always
creating innovative and stylish designs.
We work hard to develop new products, with MUSE makes your life better, easier, and more beautiful.
new designs, like the ‘Mini Touch,’ and
we have received numerous international A New Button Concept - Mini Touch
awards including the iF Design Award 2009. A new touch-type operation panel board (OPB), the Mini Touch,
adds a nice touch to your interior with its stylish shape and soft
blue lights. The attractive design received the global recognition
by iF design awards, which is one of the most authoritative design
awards in the world.

Positioning Panels for Various Ages


SIGMA considers the passengers’ convenience all the time.
People of all ages can easily operate the elevators with the SIGMA
designed OPBs.

Various Designs for Diverse Preference


Various designs of buttons hit the diverse tastes of people from
worldwide. Every imagine for the new elevator design can come
true by the endless efforts of SIGMA.

MUSE_14 MUSE_15
MUSE Standard Design & Fixtures

Tangent Elevator Design


Simple stripe pattern of Tangent is the basic
design, perferred by many people.
Ceiling

C-NS1 C-NL2 C-MS3


(Painted steel sheet color No.LGM-924+LGM-920) (Painted steel sheet color No.LGM-924+Stainless Mirror) (Painted steel sheet color No.LGM-946)

C-RS1
One side of ceiling is lifted,
so the space is increased.

Etching Pattern COP

CBM-13C
Braille buttons help the handicapped to use
the elevator with convenience & comfort

EH3-034 EH1-067

EH1-082 EH1-085 CBM-22C CBM-13C

Front View Rear View

Specification
Handrail
CEILING C-RS1
COP CBM-13C
CAR WALL STS-ET (EW4-034)
CAR DOOR STS-ET (EH3-034) HR-04 HR-05
HANDRAIL HR-04
FLOOR Decotile (Local)
! The actual product can be different (changed) depending on design. ! The actual product can be different (changed) depending on design.
Car wall image can be different (changed) depending on capacity. Car wall image can be different (changed) depending on capacity.

MUSE_16 MUSE_17
MUSE Standard Design MUSE Luxury Design

Plain Elevator Design


Plain provides the comfortable outlook
with its pattern of nature. Garden Elevator Design
Garden’s hi-glossy coated soft brown color with floral
pattern gives the soft and bright feeling in the car.

Including
Air Purifier

C-RS2 C-RL2
The acryl ceiling in Mondrian look The air purifier system cleans and
brightens the space and provides the deodorizes the air in the car.
artistic atmosphere.

W-SLT-HG:SC-006
HR-18 The hi-glossy coated wall
The wooden pattern handrail upgrades highlights the exclusive design
the style of the elevator in floral pattern

Front View Rear View Front View Rear View

Specification Specification
CEILING C-RS2 CEILING C-RL2
COP CBM-22C COP CBX-16C (STS Mirror)
CAR WALL STS-ET (EW2-085) CAR WALL W-SLT-HG : SC-006
CAR DOOR STS-ET (EH1-085) CAR DOOR Hi-glossy
HANDRAIL HR-18 HANDRAIL HR-18
FLOOR Miraton (Local) FLOOR Miraton (Local)
! The actual product can be different (changed) depending on design. ! The actual product can be different (changed) depending on design.
Car wall image can be different (changed) depending on capacity. Car wall image can be different (changed) depending on capacity.

MUSE_18 MUSE_19
MUSE Luxury Design

Vineyard Elevator Design


Combination of Vineyard’s gold and wine color with
the elegant floral pattern provides the superior design

C-RP1
The variance of material and height
in ceiling design enables the most
cutting-edge design

Mini Touch
Touch Technology with the superior
design, awarded by iF design award
in 2009

The stylish and beautiful look of the Mini Touch, and its
superior functionality, enable designs with new concepts
that are even better than you can imagine.

Front View Rear View


Specification
CEILING C-RP1
COP CBT-70C
CAR WALL RESIN COATING, W-LM-RP (W):EW2-087
CAR DOOR RESIN COATING, W-LM-RP (W):EW1-087
HANDRAIL HR-15
FLOOR Miraton (Local)
! The actual product can be different (changed) depending on design.
Car wall image can be different (changed) depending on capacity.

MUSE_20 MUSE_21
Simple, sleek, and sensitive

Experience a New World


with Mini Touch

Superior Design
Recognition of Authoritative Design Awards
- iF Design Award Win, Good Design Award

Convenient Function
Half-lighting that can be easily seen in
the dark

A Variety of Design
Various Types of Buttons and Cases

Product Reliability
Passed numerous Korean quality tests

Mini Touch Series

MUSE_22 MUSE_23
Car & Landing Fixtures Indicator

● COP ● Horizontal Indicator


※ Premium Design (Option)

HIX-A162 HIX-C162

HID-A122 HID-C122

HIX-A122 HIX-C122

● Lumina Design (Option)

15�

CBM-22C CBX-22C CBM-13C CBX-13C CBX-16C

HIX-A182 (Installed on Transom) HIX-A183 (Installed on Transom)


HIX-C182 (Installed on Wall) HIX-C183 (Installed on Wall)

● Handicapped COP ● Vertical Indicator


12 mm
※ Premium Design (Option)

51 mm
CBM-44SH 12 mm

VIX-M652 VID-M632H VIX-MA52SH VID-MA32SHP VIX-M692 VIX-MA92S Eclipse


(Slim Type) (Slim Type) HLV-C48X HLV-C48 HBM-R35SGH VIX-M352SGH CBX-22G
CBM-42SH

! The actual product can be different (changed) depending on design. ! The actual product can be different (changed) depending on design.

MUSE_24 MUSE_25
Car Fixtures Etching Pattern

● Ceiling ● Hi-glossy Pattern


SLT-HG SLT-HG SLT-HG
(SHC-003) (SHC-005) (SHC-006)

C-RS1 (LGP-945) C-RS2 (LGP-945)

● STS Etching Pattern


EH3-034 EH1-059 EH1-067

C-MS3 (LGP-946)〔Option〕 C-NL2 (LGP-945)〔Option〕

EH1-080 EH1-082 EH1-084

(Including Air Purifier)

C-RL1〔Option〕 C-RL2〔Option〕 EH1-085 EH1-086 EH1-087

● Handrail

HR-04

HR-05

● Colors
HR-18〔Option〕
C-RP1〔Option〕

HR-15(Wood)〔Option〕
LGP-004 LGP-928 LGP-927 LGP-944 LGP-924 LGP-923 LGP-015 LGP-925 LGP-943 LGP-934

! The actual product can be different (changed) depending on design. ! The actual product can be different (changed) depending on design.

MUSE_26 MUSE_27
Entrance Design Observation
● Ground Floor ● Top Floor ●3 Side View

JAMB J-311 (STS Mirror) JAMB J-301 (STS Hairline)


DOOR STS Mirror Etching (EW2-085) DOOR STS Hairline Etching (EW2-084)
HALL IND HIX-A162 HALL IND & BUTTON VIX-MA52SH
HALL LANTERN HLV-C08 LANDING CABINET STS Hairline
HALL BUTTON HBM-R95

● Other Floors ● Other Floors

●1 Side View ●2 Side View

JAMB J-301 (STS Hairline) JAMB J-101 (STS Hairline)


DOOR STS Hairline Etching (EH3-034) DOOR STS Hairline Etching (EH1-067)
HALL IND & BUTTON VIX-MA52SH HALL IND & BUTTON VIX-MA52SH

! The actual product can be different (changed) depending on design. ! The actual product can be different (changed) depending on design.

MUSE_28 MUSE_29
Detailed Drawing of Overhead E L E VAT O R D E S I G N Detailed Drawing of Hoist-Way E L E VAT O R D E S I G N

(LD Model 8~17 persons Actual OH Below 4500mm) (LD Model 8~17 persons Actual OH Over 4500mm)
(Passenger / Observation : Simplex) (Hoistway Section)

(Passenger / Observation : Duplex)

(ED Model 17~24 persons)

Location Dimension Application


Maximum 17 passengers Car Inside(W) : 1800
A 540 Maximum 17 passengers Car Inside(W) : 1900
Maximum 20 passengers Car Inside(W) : 2000
615 Except Above
B 89 +〔Car Size(W)+100〕/ 2

! Contact our company for overhead reaction force and the dimensions of detailed hoist-way patch

MUSE_30 MUSE_31
Detailed Drawing of Entrance E L E VAT O R D E S I G N Detailed Drawing of Entrance E L E VAT O R D E S I G N

View A-A

Normal Type Button

MUSE_32 MUSE_33
Detailed Drawing of Entrance (The Top Floor) E L E VAT O R D E S I G N Detailed Drawing of Steel Frame Entrance E L E VAT O R D E S I G N

Wide Taper Jamb (Except Top Floor)

Narrow Jamb

MUSE_34 MUSE_35
Standard T E C H N I C A L D AT A EN Code T E C H N I C A L D AT A

(Unit : mm) (Unit : mm)


Car Size Min. Hoistway Dimension Reaction Load Car Size Min. Hoistway Dimension Reaction Load
Speed Passenger Capacity Opening OP Inside Width Inside Depth Outside Width Outside Depth Simplex Duplex OH PIT (kg) Speed Passenger Capacity Opening OP Inside Width Inside Depth Outside Width Outside Depth (kg)
(kg) Type Simplex Duplex OH PIT
(m/min.) (m/min.) (kg) Type
AN BN AS BS AH BH AH BH R1 R2 AN BN AS BS AH BH AH BH R1 R2

8 550 800 1350 1050 1400 1232 2000 1600 4100 1600 3800 1200 5900 4700 7 525 800 1350 1050 1400 1232 2000 1600 4100 1600 3800 1200 5900 4700
9 600 800 1350 1130 1400 1312 2000 1650 4100 1650 3800 1200 6100 4900 8 600 800 1350 1130 1400 1312 2000 1650 4100 1650 3800 1200 6100 4900
10 700 800 1350 1280 1400 1462 2000 1800 4100 1800 3800 1200 6900 5400 9 675 800 1350 1280 1400 1462 2000 1800 4100 1800 3800 1200 6900 5400
11 750 800 1350 1350 1400 1532 2000 1850 4100 1850 3800 1200 7200 5600 10 800 800 1350 1350 1400 1532 2000 1850 4100 1850 3800 1200 7200 5600
60 13 900 CO 900 1550 1350 1600 1532 2200 1850 4500 1850 3800 1200 8000 6100 60 12 900 CO 900 1550 1350 1600 1532 2200 1850 4500 1850 3800 1200 8000 6100
15 1000 900 1600 1450 1650 1632 2250 1900 4600 1900 3800 1200 8500 6400 13 1000 900 1600 1450 1650 1632 2250 1900 4600 1900 3800 1200 8500 6400
17 1150 1000 1800 1450 1850 1632 2450 1900 5000 1900 3800 1200 9500 7100 16 1200 1000 1800 1450 1850 1632 2450 1900 5000 1900 3800 1200 9500 7100
20 1350 1000 1800 1650 1872 1813 2610 2000 5320 2000 4100 1500 12400 9600 18 1350 1000 1800 1650 1872 1813 2610 2000 5320 2000 4100 1500 12400 9600
24 1600 1100 2000 1700 2072 1863 2810 2050 5720 2050 4100 1500 13700 10300 21 1600 1100 2000 1700 2072 1863 2810 2050 5720 2050 4100 1500 13700 10300
8 550 800 1350 1050 1400 1232 2000 1600 4100 1600 3900 1300 6800 5000 7 525 800 1350 1050 1400 1232 2000 1600 4100 1600 3900 1300 6800 5000
9 600 800 1350 1130 1400 1312 2000 1650 4100 1650 3900 1300 7000 5200 8 600 800 1350 1130 1400 1312 2000 1650 4100 1650 3900 1300 7000 5200
10 700 800 1350 1280 1400 1462 2000 1800 4100 1800 3900 1300 7900 5700 9 675 800 1350 1280 1400 1462 2000 1800 4100 1800 3900 1300 7900 5700
11 750 800 1350 1350 1400 1532 2000 1850 4100 1850 3900 1300 8200 5900 10 800 800 1350 1350 1400 1532 2000 1850 4100 1850 3900 1300 8200 5900
90 13 900 CO 900 1550 1350 1600 1532 2200 1850 4500 1850 3900 1300 9200 6400 90 12 900 CO 900 1550 1350 1600 1532 2200 1850 4500 1850 3900 1300 9200 6400
15 1000 900 1600 1450 1650 1632 2250 1900 4600 1900 3900 1300 9700 6800 13 1000 900 1600 1450 1650 1632 2250 1900 4600 1900 3900 1300 9700 6800
17 1150 1000 1800 1450 1850 1632 2450 1900 5000 1900 3900 1300 10900 7500 16 1200 1000 1800 1450 1850 1632 2450 1900 5000 1900 3900 1300 10900 7500
20 1350 1000 1800 1650 1872 1813 2610 2000 5320 2000 4250 1800 15000 10700 18 1350 1000 1800 1650 1872 1813 2610 2000 5320 2000 4250 1800 15000 10700
24 1600 1100 2000 1700 2072 1863 2810 2050 5720 2050 4250 1800 16600 11500 21 1600 1100 2000 1700 2072 1863 2810 2050 5720 2050 4250 1800 16600 11500
8 550 800 1350 1050 1400 1232 2000 1600 4100 1600 4000 1400 7000 5200 7 525 800 1350 1050 1400 1232 2000 1600 4100 1600 4000 1400 7000 5200
9 600 800 1350 1130 1400 1312 2000 1650 4100 1650 4000 1400 7300 5400 8 600 800 1350 1130 1400 1312 2000 1650 4100 1650 4000 1400 7300 5400
10 700 800 1350 1280 1400 1462 2000 1800 4100 1800 4000 1400 8200 5900 9 675 800 1350 1280 1400 1462 2000 1800 4100 1800 4000 1400 8200 5900
11 750 800 1350 1350 1400 1532 2000 1850 4100 1850 4000 1400 8600 6200 10 800 800 1350 1350 1400 1532 2000 1850 4100 1850 4000 1400 8600 6200
105 13 900 CO 900 1550 1350 1600 1532 2200 1850 4500 1850 4000 1400 9500 6700 105 12 900 CO 900 1550 1350 1600 1532 2200 1850 4500 1850 4000 1400 9500 6700
15 1000 900 1600 1450 1650 1632 2250 1900 4600 1900 4000 1400 10200 7000 13 1000 900 1600 1450 1650 1632 2250 1900 4600 1900 4000 1400 10200 7000
17 1150 1000 1800 1450 1850 1632 2450 1900 5000 1900 4000 1400 11300 7800 16 1200 1000 1800 1450 1850 1632 2450 1900 5000 1900 4000 1400 11300 7800
20 1350 1000 1800 1650 1872 1813 2610 2000 5320 2000 4350 2100 13200 9400 18 1350 1000 1800 1650 1872 1813 2610 2000 5320 2000 4350 2100 13200 9400
24 1600 1100 2000 1700 2072 1863 2810 2050 5720 2050 4350 2100 14500 10200 21 1600 1100 2000 1700 2072 1863 2810 2050 5720 2050 4350 2100 14500 10200
(Unit : mm) (Unit : mm)
Car Size Min. Hoistway Dimension Reaction Load Car Size Min. Hoistway Dimension Reaction Load
Speed Passenger Capacity Opening OP OH PIT (kg) Speed Passenger Capacity Opening OP (kg)
Inside Width Inside Depth Outside Width Outside Depth Simplex Duplex Inside Width Inside Depth Outside Width Outside Depth Simplex Duplex OH PIT
(m/min.) (kg) Type (m/min.) (kg) Type
AN BN AS BS AH BH AH BH R1 R2 AN BN AS BS AH BH AH BH R1 R2

8 550 800 1100 1300 1150 1501 1750 1800 3600 1800 3800 1200 6000 4900 7 525 800 1100 1300 1150 1501 1750 1800 3600 1800 3800 1200 6000 4900
9 600 800 1100 1380 1150 1581 1750 1850 3600 1850 3800 1200 6300 5000 8 600 800 1100 1380 1150 1581 1750 1850 3600 1850 3800 1200 6300 5000
10 700 800 1100 1550 1150 1751 1750 2050 3600 2050 3800 1200 7000 5600 9 675 800 1100 1550 1150 1751 1750 2050 3600 2050 3800 1200 7000 5600
11 750 800 1200 1520 1250 1721 1850 2000 3800 2000 3800 1200 7400 5800 10 800 800 1200 1520 1250 1721 1850 2000 3800 2000 3800 1200 7400 5800
60 13 900 2S 900 1200 1770 1250 1971 1850 2250 3800 2250 3800 1200 8100 6200 60 12 900 2S 900 1200 1770 1250 1971 1850 2250 3800 2250 3800 1200 8100 6200
15 1000 900 1250 1850 1300 2051 1900 2250 3900 2250 3800 1200 8600 6500 13 1000 900 1250 1850 1300 2051 1900 2250 3900 2250 3800 1200 8600 6500
17 1150 1000 1300 2010 1350 2211 1950 2500 4000 2500 3800 1200 9600 7100 16 1200 1000 1300 2010 1350 2211 1950 2500 4000 2500 3800 1200 9600 7100
20 1350 1000 1300 2300 1372 2515 2100 2750 4300 2750 4100 1500 12700 9900 18 1350 1000 1300 2300 1372 2515 2100 2750 4300 2750 4100 1500 12700 9900
24 1600 1100 1500 2300 1572 2515 2300 2750 4700 2750 4100 1500 14000 10600 21 1600 1100 1500 2300 1572 2515 2300 2750 4700 2750 4100 1500 14000 10600
8 550 800 1200 1300 1150 1501 1750 1800 3600 1800 3900 1300 6900 5200 7 525 800 1200 1300 1150 1501 1750 1800 3600 1800 3900 1300 6900 5200
9 600 800 1100 1380 1150 1581 1750 1850 3600 1850 3900 1300 7200 5300 8 600 800 1100 1380 1150 1581 1750 1850 3600 1850 3900 1300 7200 5300
10 700 800 1100 1550 1150 1751 1750 2050 3600 2050 3900 1300 8100 5900 9 675 800 1100 1550 1150 1751 1750 2050 3600 2050 3900 1300 8100 5900
11 750 800 1200 1520 1250 1721 1850 2000 3800 2000 3900 1300 8400 6100 10 800 800 1200 1520 1250 1721 1850 2000 3800 2000 3900 1300 8400 6100
90 13 900 2S 900 1200 1770 1250 1971 1850 2250 3800 2250 3900 1300 9300 6600 90 12 900 2S 900 1200 1770 1250 1971 1850 2250 3800 2250 3900 1300 9300 6600
15 1000 900 1250 1850 1300 2051 1900 2250 3900 2250 3900 1300 9900 6900 13 1000 900 1250 1850 1300 2051 1900 2250 3900 2250 3900 1300 9900 6900
17 1150 1000 1300 2010 1350 2211 1950 2500 4000 2500 3900 1300 11000 7600 16 1200 1000 1300 2010 1350 2211 1950 2500 4000 2500 3900 1300 11000 7600
20 1350 1000 1300 2300 1372 2515 2100 2750 4300 2750 4250 1800 15400 11000 18 1350 1000 1300 2300 1372 2515 2100 2750 4300 2750 4250 1800 15400 11000
24 1600 1100 1500 2300 1572 2515 2300 2750 4700 2750 4250 1800 16900 11800 21 1600 1100 1500 2300 1572 2515 2300 2750 4700 2750 4250 1800 16900 11800
8 550 800 1100 1300 1150 1501 1750 1800 3600 1800 4000 1400 7200 5400 7 525 800 1100 1300 1150 1501 1750 1800 3600 1800 4000 1400 7200 5400
9 600 800 1100 1380 1150 1581 1750 1850 3600 1850 4000 1400 7600 5600 8 600 800 1100 1380 1150 1581 1750 1850 3600 1850 4000 1400 7600 5600
10 700 800 1100 1550 1150 1751 1750 2050 3600 2050 4000 1400 8400 6100 9 675 800 1100 1550 1150 1751 1750 2050 3600 2050 4000 1400 8400 6100
11 750 800 1200 1520 1250 1721 1850 2000 3800 2000 4000 1400 8800 6400 10 800 800 1200 1520 1250 1721 1850 2000 3800 2000 4000 1400 8800 6400
105 13 900 2S 900 1200 1770 1250 1971 1850 2250 3800 2250 4000 1400 9700 6900 105 12 900 2S 900 1200 1770 1250 1971 1850 2250 3800 2250 4000 1400 9700 6900
15 1000 900 1250 1850 1300 2051 1900 2250 3900 2250 4000 1400 10300 7200 13 1000 900 1250 1850 1300 2051 1900 2250 3900 2250 4000 1400 10300 7200
17 1150 1000 1300 2010 1350 2211 1950 2500 4000 2500 4000 1400 11400 7900 16 1200 1000 1300 2010 1350 2211 1950 2500 4000 2500 4000 1400 11400 7900
20 1350 1000 1300 2300 1372 2515 2100 2750 4300 2750 4350 2100 13500 9700 18 1350 1000 1300 2300 1372 2515 2100 2750 4300 2750 4350 2100 13500 9700
24 1600 1100 1500 2300 1572 2515 2300 2750 4700 2750 4350 2100 14800 10400 21 1600 1100 1500 2300 1572 2515 2300 2750 4700 2750 4350 2100 14800 10400
*CO (2 Panel Center Opening) *2S (2 Panel Side Opening) *CO (2 Panel Center Opening) *2S (2 Panel Side Opening)

MUSE_36 MUSE_37
Singapore T E C H N I C A L D AT A Malaysia T E C H N I C A L D AT A

(Unit : mm) (Unit : mm)


Car Size Min. Hoistway Dimension Reaction Load Car Size Min. Hoistway Dimension Reaction Load
Speed Passenger Capacity Opening OP (kg) Speed Passenger Capacity Opening OP Inside Width Inside Depth Outside Width Outside Depth Simplex (kg)
(m/min.) (kg) Type Inside Width Inside Depth Outside Width Outside Depth Simplex Duplex OH PIT Duplex OH PIT
(m/min.) (kg) Type
AN BN AS BS AH BH AH BH R1 R2 AN BN AS BS AH BH AH BH R1 R2
7 545 800 1350 1050 1400 1232 2000 1600 4100 1600 3800 1200 5900 4700 8 550 800 1350 1050 1400 1232 2000 1600 4100 1600 3800 1200 5900 4700
8 610 800 1350 1130 1400 1312 2000 1650 4100 1650 3800 1200 6100 4900 9 615 800 1350 1130 1400 1312 2000 1650 4100 1650 3800 1200 6100 4900
9 680 800 1350 1280 1400 1462 2000 1800 4100 1800 3800 1200 6900 5400 10 685 800 1350 1280 1400 1462 2000 1800 4100 1800 3800 1200 6900 5400
10 750 800 1350 1350 1400 1532 2000 1850 4100 1850 3800 1200 7200 5600 11 750 800 1350 1350 1400 1532 2000 1850 4100 1850 3800 1200 7200 5600
60 12 885 CO 900 1550 1350 1600 1532 2200 1850 4500 1850 3800 1200 8000 6100 60 13 885 CO 900 1550 1350 1600 1532 2200 1850 4500 1850 3800 1200 8000 6100
13 1020 900 1600 1450 1650 1632 2250 1900 4600 1900 3800 1200 8500 6400 15 1025 900 1600 1450 1650 1632 2250 1900 4600 1900 3800 1200 8500 6400
16 1155 1000 1800 1450 1850 1632 2450 1900 5000 1900 3800 1200 9500 7100 17 1160 1000 1800 1450 1850 1632 2450 1900 5000 1900 3800 1200 9500 7100
18 1360 1000 1800 1650 1872 1813 2610 2000 5320 2000 4100 1500 12400 9600 20 1355 1000 1800 1650 1872 1813 2610 2000 5320 2000 4100 1500 12400 9600
21 1630 1100 2000 1700 2072 1863 2810 2050 5720 2050 4100 1500 13700 10300 23 1635 1100 2000 1700 2072 1863 2810 2050 5720 2050 4100 1500 13700 10300
7 545 800 1350 1050 1400 1232 2000 1600 4100 1600 3900 1300 6800 5000 8 550 800 1350 1050 1400 1232 2000 1600 4100 1600 3900 1300 6800 5000
8 610 800 1350 1130 1400 1312 2000 1650 4100 1650 3900 1300 7000 5200 9 615 800 1350 1130 1400 1312 2000 1650 4100 1650 3900 1300 7000 5200
9 680 800 1350 1280 1400 1462 2000 1800 4100 1800 3900 1300 7900 5700 10 685 800 1350 1280 1400 1462 2000 1800 4100 1800 3900 1300 7900 5700
10 750 800 1350 1350 1400 1532 2000 1850 4100 1850 3900 1300 8200 5900 11 750 800 1350 1350 1400 1532 2000 1850 4100 1850 3900 1300 8200 5900
90 12 885 CO 900 1550 1350 1600 1532 2200 1850 4500 1850 3900 1300 9200 6400 90 13 885 CO 900 1550 1350 1600 1532 2200 1850 4500 1850 3900 1300 9200 6400
13 1020 900 1600 1450 1650 1632 2250 1900 4600 1900 3900 1300 9700 6800 15 1025 900 1600 1450 1650 1632 2250 1900 4600 1900 3900 1300 9700 6800
16 1155 1000 1800 1450 1850 1632 2450 1900 5000 1900 3900 1300 10900 7500 17 1160 1000 1800 1450 1850 1632 2450 1900 5000 1900 3900 1300 10900 7500
18 1360 1000 1800 1650 1872 1813 2610 2000 5320 2000 4250 1800 15000 10700 20 1355 1000 1800 1650 1872 1813 2610 2000 5320 2000 4250 1800 15000 10700
21 1630 1100 2000 1700 2072 1863 2810 2050 5720 2050 4250 1800 16600 11500 23 1635 1100 2000 1700 2072 1863 2810 2050 5720 2050 4250 1800 16600 11500
7 545 800 1350 1050 1400 1232 2000 1600 4100 1600 4000 1400 7000 5200 8 550 800 1350 1050 1400 1232 2000 1600 4100 1600 4000 1400 7000 5200
8 610 800 1350 1130 1400 1312 2000 1650 4100 1650 4000 1400 7300 5400 9 615 800 1350 1130 1400 1312 2000 1650 4100 1650 4000 1400 7300 5400
9 680 800 1350 1280 1400 1462 2000 1800 4100 1800 4000 1400 8200 5900 10 685 800 1350 1280 1400 1462 2000 1800 4100 1800 4000 1400 8200 5900
10 750 800 1350 1350 1400 1532 2000 1850 4100 1850 4000 1400 8600 6200 11 750 800 1350 1350 1400 1532 2000 1850 4100 1850 4000 1400 8600 6200
105 12 885 CO 900 1550 1350 1600 1532 2200 1850 4500 1850 4000 1400 9500 6700 105 13 885 CO 900 1550 1350 1600 1532 2200 1850 4500 1850 4000 1400 9500 6700
13 1020 900 1600 1450 1650 1632 2250 1900 4600 1900 4000 1400 10200 7000 15 1025 900 1600 1450 1650 1632 2250 1900 4600 1900 4000 1400 10200 7000
16 1155 1000 1800 1450 1850 1632 2450 1900 5000 1900 4000 1400 11300 7800 17 1160 1000 1800 1450 1850 1632 2450 1900 5000 1900 4000 1400 11300 7800
18 1360 1000 1800 1650 1872 1813 2610 2000 5320 2000 4350 2100 13200 9400 20 1355 1000 1800 1650 1872 1813 2610 2000 5320 2000 4350 2100 13200 9400
21 1630 1100 2000 1700 2072 1863 2810 2050 5720 2050 4350 2100 14500 10200 23 1635 1100 2000 1700 2072 1863 2810 2050 5720 2050 4350 2100 14500 10200
(Unit : mm) (Unit : mm)
Car Size Min. Hoistway Dimension Reaction Load Car Size Min. Hoistway Dimension Reaction Load
Speed Passenger Capacity Opening OP OH PIT (kg) Speed Passenger Capacity Opening OP Inside Width Inside Depth Outside Width Outside Depth Simplex (kg)
Inside Width Inside Depth Outside Width Outside Depth Simplex Duplex Duplex OH PIT
(m/min.) (kg) Type (m/min.) (kg) Type
AN BN AS BS AH BH AH BH R1 R2 AN BN AS BS AH BH AH BH R1 R2
7 545 800 1100 1300 1150 1501 1750 1800 3600 1800 3800 1200 6000 4900 8 550 800 1100 1300 1150 1501 1750 1800 3600 1800 3800 1200 6000 4900
8 610 800 1100 1380 1150 1581 1750 1850 3600 1850 3800 1200 6300 5000 9 615 800 1100 1380 1150 1581 1750 1850 3600 1850 3800 1200 6300 5000
9 680 800 1100 1550 1150 1751 1750 2050 3600 2050 3800 1200 7000 5600 10 685 800 1100 1550 1150 1751 1750 2050 3600 2050 3800 1200 7000 5600
10 750 800 1200 1520 1250 1721 1850 2000 3800 2000 3800 1200 7400 5800 11 750 800 1200 1520 1250 1721 1850 2000 3800 2000 3800 1200 7400 5800
60 12 885 2S 900 1200 1770 1250 1971 1850 2250 3800 2250 3800 1200 8100 6200 60 13 885 2S 900 1200 1770 1250 1971 1850 2250 3800 2250 3800 1200 8100 6200
13 1020 900 1250 1850 1300 2051 1900 2250 3900 2250 3800 1200 8600 6500 15 1025 900 1250 1850 1300 2051 1900 2250 3900 2250 3800 1200 8600 6500
16 1155 1000 1300 2010 1350 2211 1950 2500 4000 2500 3800 1200 9600 7100 17 1160 1000 1300 2010 1350 2211 1950 2500 4000 2500 3800 1200 9600 7100
18 1360 1000 1300 2300 1372 2515 2100 2750 4300 2750 4100 1500 12700 9900 20 1355 1000 1300 2300 1372 2515 2100 2750 4300 2750 4100 1500 12700 9900
21 1630 1100 1500 2300 1572 2515 2300 2750 4700 2750 4100 1500 14000 10600 23 1635 1100 1500 2300 1572 2515 2300 2750 4700 2750 4100 1500 14000 10600
7 545 800 1200 1300 1150 1501 1750 1800 3600 1800 3900 1300 6900 5200 8 550 800 1200 1300 1150 1501 1750 1800 3600 1800 3900 1300 6900 5200
8 610 800 1100 1380 1150 1581 1750 1850 3600 1850 3900 1300 7200 5300 9 615 800 1100 1380 1150 1581 1750 1850 3600 1850 3900 1300 7200 5300
9 680 800 1100 1550 1150 1751 1750 2050 3600 2050 3900 1300 8100 5900 10 685 800 1100 1550 1150 1751 1750 2050 3600 2050 3900 1300 8100 5900
10 750 800 1200 1520 1250 1721 1850 2000 3800 2000 3900 1300 8400 6100 11 750 800 1200 1520 1250 1721 1850 2000 3800 2000 3900 1300 8400 6100
90 12 885 2S 900 1200 1770 1250 1971 1850 2250 3800 2250 3900 1300 9300 6600 90 13 885 2S 900 1200 1770 1250 1971 1850 2250 3800 2250 3900 1300 9300 6600
13 1020 900 1250 1850 1300 2051 1900 2250 3900 2250 3900 1300 9900 6900 15 1025 900 1250 1850 1300 2051 1900 2250 3900 2250 3900 1300 9900 6900
16 1155 1000 1300 2010 1350 2211 1950 2500 4000 2500 3900 1300 11000 7600 17 1160 1000 1300 2010 1350 2211 1950 2500 4000 2500 3900 1300 11000 7600
18 1360 1000 1300 2300 1372 2515 2100 2750 4300 2750 4250 1800 15400 11000 20 1355 1000 1300 2300 1372 2515 2100 2750 4300 2750 4250 1800 15400 11000
21 1630 1100 1500 2300 1572 2515 2300 2750 4700 2750 4250 1800 16900 11800 23 1635 1100 1500 2300 1572 2515 2300 2750 4700 2750 4250 1800 16900 11800
7 545 800 1100 1300 1150 1501 1750 1800 3600 1800 4000 1400 7200 5400 8 550 800 1100 1300 1150 1501 1750 1800 3600 1800 4000 1400 7200 5400
8 610 800 1100 1380 1150 1581 1750 1850 3600 1850 4000 1400 7600 5600 9 615 800 1100 1380 1150 1581 1750 1850 3600 1850 4000 1400 7600 5600
9 680 800 1100 1550 1150 1751 1750 2050 3600 2050 4000 1400 8400 6100 10 685 800 1100 1550 1150 1751 1750 2050 3600 2050 4000 1400 8400 6100
10 750 800 1200 1520 1250 1721 1850 2000 3800 2000 4000 1400 8800 6400 11 750 800 1200 1520 1250 1721 1850 2000 3800 2000 4000 1400 8800 6400
105 12 885 2S 900 1200 1770 1250 1971 1850 2250 3800 2250 4000 1400 9700 6900 105 13 885 2S 900 1200 1770 1250 1971 1850 2250 3800 2250 4000 1400 9700 6900
13 1020 900 1250 1850 1300 2051 1900 2250 3900 2250 4000 1400 10300 7200 15 1025 900 1250 1850 1300 2051 1900 2250 3900 2250 4000 1400 10300 7200
16 1155 1000 1300 2010 1350 2211 1950 2500 4000 2500 4000 1400 11400 7900 17 1160 1000 1300 2010 1350 2211 1950 2500 4000 2500 4000 1400 11400 7900
18 1360 1000 1300 2300 1372 2515 2100 2750 4300 2750 4350 2100 13500 9700 20 1355 1000 1300 2300 1372 2515 2100 2750 4300 2750 4350 2100 13500 9700
21 1630 1100 1500 2300 1572 2515 2300 2750 4700 2750 4350 2100 14800 10400 23 1635 1100 1500 2300 1572 2515 2300 2750 4700 2750 4350 2100 14800 10400
*CO (2 Panel Center Opening) *2S (2 Panel Side Opening) *CO (2 Panel Center Opening) *2S (2 Panel Side Opening)

MUSE_38 MUSE_39
Through Type T E C H N I C A L D AT A Technical Features T E C H N I C A L D AT A

Standard Option
(Unit : mm)
Car Size Min. Hoistway Dimension Reaction Load Feature Description Remark
Speed Passenger Capacity Opening OP (kg)
Inside Width Inside Depth Outside Width Outside Depth Simplex Duplex OH PIT
(m/min.) (kg) Type The operating mode of an elevator can be changed from the normal automatic operation to the
AN BN AS BS AH BH AH BH R1 R2 Attendant Operation
attendant service by an attendant switch.
11 750 800 1350 1300 1400 1580 2000 1810 4100 1810 3800 1200 8000 6400
Key switch in the car operating panel will cancel any existing car calls and hold the door open at
13 900 900 1550 1300 1600 1580 2200 1810 4500 1810 3800 1200 8800 6900 Independent Operation
the landing position. During independent operation, the car will respond only to car calls.
15 1000 900 1600 1400 1650 1680 2250 1910 4600 1910 3800 1200 9300 7200
60 CO
17 1150 1000 1800 1400 1850 1680 2450 1910 5000 1910 3800 1200 10200 7800 When the electrical transmission device between the hall call and control panel begins to
20 1350 1000 1800 1630 1872 1906 2610 2140 5320 2140 4100 1500 13000 10200 operate in an abnormal condition and it lasts for some time, the elevator control device is
24 1600 1100 2000 1690 2072 2071 2810 2200 5720 2200 4100 1500 14300 10900 Back-up operation converted to back-up operation automatically. Then, the elevator moves in sequence up and
11 750 800 1350 1300 1400 1580 2000 1810 4100 1810 3900 1300 8000 6400 down repeatedly from top to bottom floor to service every other floor which is in normal
13 900 900 1550 1300 1600 1580 2200 1810 4500 1810 3900 1300 8800 6900 condition.
15 1000 900 1600 1400 1650 1680 2250 1910 4600 1910 3900 1300 9300 7200
90 CO When a car stops between floors due to mechanical malfunction, it will descend to the nearest
17 1150 1000 1800 1400 1850 1680 2450 1910 5000 1910 3900 1300 10200 7800 Safe Drive Operation
20 1350 1000 1800 1630 1872 1906 2610 2140 5320 2140 4250 1800 13000 10200 floor at a low speed and hold the doors open after checking all safety measures.
24 1600 1100 2000 1690 2072 2071 2810 2200 5720 2200 4250 1800 14300 10900
Allows cancellation of an incorrectly registered car call. For example, if you press the button for
11 750 800 1350 1300 1400 1580 2000 1810 4100 1810 4000 1400 8000 6400 Car Call Cancellation
the wrong floor, you can cancel by pressing the same floor button again.
13 900 900 1550 1300 1600 1580 2200 1810 4500 1810 4000 1400 8800 6900
15 1000 900 1600 1400 1650 1680 2250 1910 4600 1910 4000 1400 9300 7200 Automatic Turn-Off of Car illumination and fan are turned off automatically in case there is no hall call or car call; this
105 CO
17 1150 1000 1800 1400 1850 1680 2450 1910 5000 1910 4000 1400 10200 7800 Car Light & Fan saves energy.
20 1350 1000 1800 1630 1872 1906 2610 2140 5320 2140 4350 2100 13000 10200
24 1600 1100 2000 1690 2072 2071 2810 2200 5720 2200 4350 2100 14300 10900 A fully-loaded car ( More than 80% of rated load) bypasses hall calls in order to maintain
Automatic Bypass
maximum operational efficiency.
*CO (2 Panel Center Opening)
When the number of passengers exceeds the normal capacity, a buzzer sounds and the elevator
Overload Holding Stop
remains stopped at that floor. When the excessive number of passengers disembark, the buzzer
(110% of rated load)
stops, the elevator doors close, and operation continues.

Detection of Jammed If a hall button is jammed mechanically, the hall call will be automatically bypassed after being
Electrical Data T E C H N I C A L D AT A Hall Button served once, until the program is resolved.

Extending the full height of the car door, this device causes the doors to return to the fully open
Car Door Safety Edge
(Unit : mm) position should the door encounter a person or obstacle while closing.

Motor Transformer Lead-in Earth Heat Starting An automatic two way leveling device is provided to maintain the elevator car level with the
MCCB Capacity Micro Levelling
Capacity Capacity Wire Size Wire Size Output Power landing, regardless of elevator load or direction of travel.
Speed Passenger Capacity
(m/min.) (kg) (A) (kVA) (㎟)
(kW) (㎟) (kcal/hr) (kVA/set) N-Plex Operation It can control up to 4 sets of elevators to optimize allocation of hall calls.
1 unit 2 unit 1 unit 2 unit 1 unit 2 unit
8 550 4.1 20 40 6.2 12.4 5.5 5.5 3.5 825 7.2 Specific floors which are memorized in control panel can be set to disable using switch on car
Non-Stop Operation
9 600 4.1 20 40 6.7 13.4 5.5 5.5 3.5 900 7.7 operating panel or in security room.
10 700 6.4 30 60 7.6 15.2 5.5 8 3.5 1050 9.3
11 750 6.4 30 60 8 16 5.5 8 3.5 1125 9.8 The elevator can be automatically parked at the predetermined floor with its doors closed, and
Parking Operation
60 the lights and ventilation will be turned off as well.
13 900 6.4 30 60 9 18 5.5 8 3.5 1350 11
15 1000 6.4 30 60 9.8 19.6 5.5 8 3.5 1500 12 VIP Operation The specified elevator is controlled by the special call buttons provided only for VIP elevator
17 1150 6.4 40 80 11 22 5.5 8 5.5 1725 12.9
If normal building power supply fails and the building provides emergency power to the
20 1350 18.7 50 100 10 20 5.5 14 5.5 2025 28.9 Emergency Power
controller(s), one elevator at a time will proceed to the lowest landing where it will stop with
24 1600 18.7 50 100 12 24 8 14 5.5 1400 34.3 Operation
doors open and with all of its power and operating circuits in an inoperative standby condition.
8 550 6.5 30 60 8.7 17.4 5.5 8 3.5 1240 12.9
9 600 6.5 30 60 9.3 18.6 5.5 8 3.5 1350 13.8 In case of fire, a fireman can use the elevator which is stopped at the specified floor in order to
Fire return operation
10 700 10.3 30 60 10.7 21.4 5.5 8 3.5 1575 16.2 support firemen for fire-fighting.
11 750 10.3 40 80 11.3 22.6 5.5 14 5.5 1690 17.2
90 13 900 10.3 40 80 12.7 25.4 5.5 14 5.5 2025 19.2 In case of fire, a firemen can use the elevator which is stopped at the specified floor in order to
Firemen Operation
15 1000 10.3 40 80 14 28 8 14 5.5 2250 20.9 support firemen for fire-fighting.
17 1150 10.3 50 100 16 32 8 14 5.5 2560 22.6
In case of substantial difference between the number of calls registered on the car operating
20 1350 18.7 50 100 14 28 14 22 5.5 3040 43.4
Anti-nuisance Operation panel and actual load in the elevator, the elevator prevents unnecessary operation by cancelling
24 1600 18.7 75 150 16 32 14 22 5.5 3600 51.4
all registered calls when it arrives at the nearest floor.
8 550 6.5 30 60 9.9 19.8 5.5 8 3.5 1450 15.8
9 600 6.5 30 60 10.7 21.4 5.5 14 5.5 1575 16.9 When the doors remain open for more than the fixed door open time, this feature closes the
Door Nudging
10 700 10.3 40 80 12.3 24.6 5.5 14 5.5 1840 19.9 doors at a reduced closing speed with the buzzer sounding.
11 750 10.3 40 80 13.1 26.2 5.5 14 5.5 1970 21.1
105 13 900 10.3 50 100 14.6 29.2 8 22 5.5 2370 23.5 This system provides riding passengers with audio information about car operation such as
Voice Synthesizer
15 1000 10.3 50 100 16.1 32.2 8 22 5.5 2625 25.7 direction of travel, landing floor, etc.
17 1150 10.3 60 120 18.4 36.8 14 22 6.5 3020 27.7
20 1350 18.7 75 150 16 32 14 22 6.5 3550 50.6 The doors reverse to fully open position if the light ray unit detects an obstacle when the doors
Door Photo Sensor
24 1600 18.7 75 150 18 36 22 38 5.5 4200 60 are closing.

MUSE_40 MUSE_41
Work by Others T E C H N I C A L D AT A

The works below are not included in the elevator installation work and should be carried out by building
contractors in accordance with our drawings, relevant international or local codes and regulations.

Hoist way

∙A properly framed and enclosed hoistway, including any ventilation as required by the governing code authority.
∙A dry pit constructed to the elevator manufacturer's specifications to reinforce or sustain any vertical on the guide rails and impacted
loads from the car and counterweight buffers.
∙A metal sill angle or concrete haunch across the full width of the hoistway at each elevator landing.
∙Provision of steel bars to fix jamb around the entrance of each floor.
∙All cutting, including cutouts to accommodate hall singal fixtures, patching, painting of walls, floors, partitions, together with finish
painting of entrance doors and frames, if required.
∙Provision of entrance or ladder for pit access
∙Supply and installation of fascia plate.
∙Installation of emergency exits and electric wiring in blind sections of hoistway where required.
∙The tolerance of perpendicular line over the whole hoistway height must not exceed ±30mm.
∙A waterproof outlet and light fixture in the elevator pit area with the light switch being located adjacent the access door or ladder.
∙Suitable light fixture and convenience outlet in the pit with a light switch adjacent to the access door ladder.
∙The receptacles shall have protection for ground fault circuit interrupter.
∙Provision of wiring between controller and building management system.
∙A construction hoisting beam or hook, if required, with the correct location and size as determined by the elevator contractor for each
hoistway.
∙Noise insulation should be installed between machine room and adjacent residential area.

Miscellaneous

∙Wiring and piping between monitoring system.


∙Hoistway shall be free of dust or harmful gas.
∙All electric power for lighting, tools, welding, etc during installation.
∙All single phase receptacles installed in pit, and machinery spaces shall have ground fault circuit interrupter protection.
∙Fire detector for fire emergency operation.
∙A secured area for storage of elevator equipment and materials during installation.

MUSE_42