You are on page 1of 1

ONE TRIANGULAR

STIFFENER BELOW
MEMBER 10 mm THK.
2"

2"
STEEL BEAM
COVERING RHS_1
AS PER ARCHITECT

13'-2" ANCHOR BOLTS


4" 4 NOS - 12 MM
6" 6" 150MM LONG
5'-7" 5'-7"
DETAIL-1
3'-7"
2'-1"

2'-1"

PVC LOFT TANK PVC LOFT TANK STEEL BEAM STEEL ANCHOR PLATE
RHS_1 150x150x8 mm

EXISTING
RCC COLUMN
LOCATION PLAN FOR LOFT TANKS ENLARGED "DETAILS - A" AT JUNCTION
PROPOSED
STEEL COLUMN
RHS-1

13'-2" 1
RHS_1

A 1
1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1' 1'
RHS_1 RHS_1 50 x 100 x 3.2 mm SECTION A-B
1 RHS_2 35 x 35 x 2.6 mm
RHS_1

RHS_2
RHS_2
RHS_1
RHS_2
RHS_2
RHS_2
RHS_2
RHS_2
RHS_2
RHS_2
RHS_2
RHS_2
3'-7"

RHS_1
1
1 1
1
50 X 100 X 3.2 mm
VERTICAL STEEL TUBE

B FABRICAATION PLATFORM PLAN

NOTES:
1. ALL STRUCTURAL STEEL WORK SHALL CONFIRM TO LATEST IS 800.
2. ALL MEMBERS FULL WELDED ALL AROUND WITH 3mm THK WELD.
3. HOLES FOR BOLT SHALL BE AS GIVEN BELOW :

DIA OF A BOLT 12 16
DIA IF A HOLE 13.5 17.5

4. WELDING SHALL CONFIRM TO LATEST IS 816/9595.


5. ALL DIMENSIONS ARE IN MM AND DRAWINGS SHALL NOT BE SCALED.
6. ONLY DIMENSIONS IN THE SCHEDULE SHALL BE FOLLOWED.
7. CONTRACTOR SHALL CHECK ALL LEVELS & DIMENSIONS BEFORE EXECUTION OF WORK
REFERRING APPROPRIATE ARCHITECTURAL DRAWINGS.
8. PREPARE TEMPLATE BEFORE CUTTING THE MEMBERS.
11.ENSURE THAT THE MEMBERS ARE STRAIGHT.

IMPORTANT INSTRUCTIONS :

1) EXISTING STRUCTURAL STABILITY WILL NOT BE OUR RESPONSIBILITY.


2) FOR DIMENSIONS REFER ARCHITECTURAL DRAWINGS ALONG WITH THIS DRAWING.
3) DISCREPANCY IF ANY SHALL BE DISCUSSED WITH ENGINEER & ARCHITECT.