You are on page 1of 1

General Notes:

1. This drawing is not to be used for construction .

IWS-1 WALL TYPE 1


2. Drawings not to be scaled.
3. All dimensions to be checked on site.
4. All construction and shop drawings must be

Gallery Partition to 3000mm H with 100 x 50 x 10 PFC Posts @ 2300 c/s


submitted for comment and agreement prior to
fabrication.
5. Building Regulations to be checked at the time

incorporated (see SE details) U/S Slab over of design and the appropriate internal and external
specialists consulted .

Typically 150mm W, but depth varies, see drawing 2003 PFC post to SE detail

NOTES
Read in conjunction with drawings:
21_0216_IWML_DR_ED_2005 Plan - Walls
and Linings
21_0216_IWML_DR_ED_2008 Plan - Floor
fermacell fermacell Jointstik method.
Types and Levels
Joint width ≤1 mm
30 mm fermacell screws at Read in conjunction with Schedules:
3.000 21_0216_IWMD_SC_ED_5001_AFP_Finish
maximum 250 mm centres es_
Schedule for colours, materials
fermacell Standard
U-channel, size to suit Fermacell Standard U-Channel
FIN_00.00.00 denotes finishes number
specification
Read in conjunction with Specification K10-
DIN standard or equivalent 125 Fermacell 1S31-B-100-GW
30 mm fermacell screws at stud, 100mm @400c/s
250 mm centres 12.5 mm Fermacell Gypsum Fibreboard Read in conjunction with Structural
PFC post to SE detail Engineering detail for internal columns and
min 200 mm joint offset plates.
12.5 mm Ply Sheating as K11
Partitions to support max weight of 90 Kg
either side and anywhere on partition length
(max weight of heaviest painting and AV
monitor).

Partitions to be used as conduit for data and

CL PFC 100 X 50 X 10 Post electrical services from above in services

100
@2300 Centres SECTION zone. Access points for services to be
B agreed with team.
as per SE spec and detail Head detail
Notes:
All partitions to be 3 M high
in a notionally 4.2 M high space.
fermacell jointstik All partitions to have recessed skirting detail
at base and Fermicell capping at top.
FT-1 All skirtings, walls and capping to be paint
12.5mm plywood sheathing 12.5 12.5 finish in accordance with Finishes Schedule.
12.5 100 12.5
12.5mm fermacell Gypsum
DIN standard or equivalent
fibreboard stud, 100mm @400c/s SYMBOL KEY
30 mm fermacell screws at maximum IWS-01 Wall type
250 mm centres, in vertical rows of 30 mm Fermacell screws D(X+Y)01 Door type
maximum 400 mm centres (board at max 250 Centres
WT-1 Wall trim type
Trim type 1
-to-board fixing) DIN standard or equivalent
Graphic Panel type -
Flexible mastic U-channel TL GL PS
To be supplied by Others
Tight dry butt joint (fire rated as req'd)
Suitable anchors @ 400c/s FIN_0.00.00 Finishes
FFL

30
Acoustic felt/foam strip to back
fermacell standard stud, size & centres of profiles +00.000 Finished Floor Level

to suit specification: 100 mm @ 400mm 1


0000
Threshold Detail

centres FT- Floor Type

T01 22-12-05 Tender Issue

C SECTION
PLAN/ SECTION
A Base detail Rev: Date: Issue Notes:

IWM Design
Lambeth Road
London SE1 6HZ
T: 020 7091 3149

Project Name:

IWML APF Galleries


Sheet Title:

IWS 1- Wall Type 1


Scale: Drawn: Checked: Approved:

1: 5 @ A3 DM JD --
Drawing No:

21-02016_IWML_DR_ED_5000
Status Code: Date of Origin: Revision:

S0 04-24-22 T01