Professional Documents
Culture Documents
Base
Model: Crusher
Design standard: Eurocode
Used national annex: EN Recommended Values
Type of frame: unstiffened
Joint configuration: Column base joint
Joint documentation
Contents
1. Tables of load 3
1.1 1. Load case 3
1.2 2. Load case 3
2. Column base: Base plate connection 4
2.1 Joint geometry 4
2.2 Results 5
2.2.1 Dominant load case 5
2.2.1.1 Joint load 5
2.2.1.2 Summary 5
2.2.2 1. Load case 6
2.2.2.1 Joint load 6
2.2.2.2 Summary 6
2.2.3 2. Load case 6
2.2.3.1 Joint load 6
2.2.3.2 Summary 6
2.2.4 Default positive loadcase 7
2.2.4.1 Summary 7
2.2.5 Default negative loadcase 7
2.2.5.1 Summary 7
Joint documentation
1. Tables of load
1.1 1. Load case
Name of element N [kN] Vy [kN] Vz [kN] Mx [kNm] My [kNm] Mz [kNm]
Column base plane 40.00 0.00 100.00 0.00 7.00 0.00
Bottom rebars:
Material:
Lower concrete cover: 40 mm
Longitudinal reinforcement in direction X:
asX = 100.00 mm2 /m
Diameter: 12 mm
Cross reinforcement in direction Y:
asY = 100.00 mm2 /m
Diameter: 12 mm
Components:
Base plate: bp= 686.0 mm
hp= 910.0 mm
tp= 14.0 mm
S 235 EN 10025-2
ep= -5.0 mm
Grout: tg= 30 mm
C12/15 EN 1992-1-1:2010
2.2 Results
2.2.1 Dominant load case
2.2.1.2 Summary
Moment resistance: M j,Rd = 7.39 kNm
Moment utilization: 95 % Adequate
Axial design resistance: Nj,Rd = 42.23 kN
Axial utilization: 95 % Adequate
Shear resistance: V j,Rd = 115.40 kN
Shear utilization: 87 % Adequate
Dominant weld component: Web weld
Dominant weld utilization: 10 % Adequate
Initial stiffness: S j,ini = 1471.24 kNm/rad
Secant stiffness for applied moment: S j,sec = 570.11 kNm/rad
Dominant components:
Left side
Base plate in transverse bending: F t,pl,Rd = 31.89 kN
Mode 2: Bolt failure with yielding of the flange
Right side
Joint documentation
2.2.2.2 Summary
Moment resistance: M j,Rd = 7.39 kNm
Moment utilization: 95 % Adequate
Axial design resistance: Nj,Rd = 42.23 kN
Axial utilization: 95 % Adequate
Shear resistance: V j,Rd = 115.40 kN
Shear utilization: 87 % Adequate
Dominant weld component: Web weld
Dominant weld utilization: 10 % Adequate
Initial stiffness: S j,ini = 1471.24 kNm/rad
Secant stiffness for applied moment: S j,sec = 570.11 kNm/rad
Dominant components:
Left side
Base plate in transverse bending: F t,pl,Rd = 31.89 kN
Mode 2: Bolt failure with yielding of the flange
Right side
Base plate in transverse bending: F t,pl,Rd = 19.36 kN
Mode 2: Bolt failure with yielding of the flange
2.2.3.2 Summary
Moment resistance: M j,Rd = 52.91 kNm
Moment utilization: 95 % Adequate
Axial design resistance: Nj,Rd = 63.49 kN
Axial utilization: 95 % Adequate
Shear resistance: V j,Rd = 127.40 kN
Shear utilization: 78 % Adequate
Dominant weld component: Lower flange weld
Dominant weld utilization: 12 % Adequate
Initial stiffness: S j,ini = 5282.22 kNm/rad
Secant stiffness for applied moment: S j,sec = 2058.83 kNm/rad
Dominant components:
Left side
Base plate in transverse bending: F t,pl,Rd = 31.89 kN
Mode 2: Bolt failure with yielding of the flange
Right side
Concrete in compression under the column flange (6.2.6.9): F c,pl,Rd = 198.87 kN
Joint documentation
2.2.4.1 Summary
Moment resistance: M j,Rd = 25.23 kNm
Axial design resistance: Nj,Rd = 0.00 kN
Shear resistance: V j,Rd = 115.40 kN
Initial stiffness: S j,ini = 2523.49 kNm/rad
Secant stiffness for applied moment: S j,sec = 2523.49 kNm/rad
Dominant components:
Left side
Base plate in transverse bending: F t,pl,Rd = 31.89 kN
Mode 2: Bolt failure with yielding of the flange
Right side
Concrete in compression under the column flange (6.2.6.9): F c,pl,Rd = 198.87 kN
2.2.5.1 Summary
Moment resistance: M j,Rd = 15.79 kNm
Axial design resistance: Nj,Rd = 0.00 kN
Shear resistance: V j,Rd = 115.40 kN
Initial stiffness: S j,ini = 1636.04 kNm/rad
Secant stiffness for applied moment: S j,sec = 1636.04 kNm/rad
Dominant components:
Left side
Concrete in compression under the column flange (6.2.6.9): F c,pl,Rd = 198.87 kN
Right side
Base plate in transverse bending: F t,pl,Rd = 19.36 kN
Mode 2: Bolt failure with yielding of the flange