You are on page 1of 15

WARNING -- This document contains technical data the export of which is or may be restricted by the Export Administration Act

and the Export Administration Regulations (EAR), 15 C.F.R. parts 730-774. Diversion contrary to U.S. law is prohibited. The export,
reexport, transfer or re-transfer of this technical data to any other company, entity, person, or destination, or for any use or purpose other than that for which the technical data was originally provided by P&W, is prohibited without prior written approval
from P&W and authorization under applicable export control laws.
EAR Export Classification: ECCN EAR99/NLR.

Dallas Aviation Field Service 24Hr. Helpdesk: (860) 565-0140


2701 Regent Blvd. Ste. 300 Fax: (860) 565-5442
Dallas, Texas 75261 e-mail: help24@pweh.com
FAA Repair Station #J8QR089X
Tel:. (972) 512-3698 Fax: (72) 512-3743

PW6000 BORESCOPE INSPECTION REPORT


W.O.# 905257 ENG. S/N: 318109 CUSTOMER: LAN
A/C TYPE: A318 MODEL: PW6122 LOCATION: Mexico City, Mexico
POSITION: 1 A/C REG: CC-CVP DATE: 7/12/2012
REASON: Customer request PERFORMED
Page 1 of 15 Ref. P&W Quote #: BY: Philip Romero

LOW PRESSURE COMPRESSOR INSPECTION: Reference Aircraft MM Section 72-00-00


FAN BLADES (QTY 24) REF. 72-31-42 INSPECTION/CHECK-02
BLADE CONDITION:
No out of limit defects noted

DISPOSITION:
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00
Inspection/Check 07

INLET STATOR
STATOR CONDITION:
No out of limit defects noted.

DISPOSITION:

Form No.: INSP050 APP. BY:  Revision: 0 Date: 04/12/07


WARNING -- This document contains technical data the export of which is or may be restricted by the Export Administration Act and the Export Administration Regulations (EAR), 15 C.F.R. parts 730-774. Diversion contrary to U.S. law is prohibited. The export,
reexport, transfer or re-transfer of this technical data to any other company, entity, person, or destination, or for any use or purpose other than that for which the technical data was originally provided by P&W, is prohibited without prior written approval
from P&W and authorization under applicable export control laws.
EAR Export Classification: ECCN EAR99/NLR.

Dallas Aviation Field Service 24Hr. Helpdesk: (860) 565-0140


2701 Regent Blvd. Ste. 300 Fax: (860) 565-5442
Dallas, Texas 75261 e-mail: help24@pweh.com
FAA Repair Station #J8QR089X
Tel:. (972) 512-3698 Fax: (72) 512-3743

PW6000 BORESCOPE INSPECTION REPORT


W.O.# 905257 ENG. S/N: 318109 CUSTOMER: LAN
A/C TYPE: A318 MODEL: PW6122 LOCATION: Mexico City, Mexico
POSITION: 1 A/C REG: CC-CVP DATE: 7/12/2012
REASON: Customer request PERFORMED
Page 2 of 15 Ref. P&W Quote #: BY: Philip Romero
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00
Inspection/Check-02

2nd Stage BLADES (QTY 66)


BLADE CONDITION:
No out of limit defects noted.

DISPOSITION:
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00.
Inspection/Check -02

5TH STAGE BLADES (QTY 74)


BLADE CONDITION:

Form No.: INSP050 APP. BY:  Revision: 0 Date: 04/12/07


WARNING -- This document contains technical data the export of which is or may be restricted by the Export Administration Act and the Export Administration Regulations (EAR), 15 C.F.R. parts 730-774. Diversion contrary to U.S. law is prohibited. The export,
reexport, transfer or re-transfer of this technical data to any other company, entity, person, or destination, or for any use or purpose other than that for which the technical data was originally provided by P&W, is prohibited without prior written approval
from P&W and authorization under applicable export control laws.
EAR Export Classification: ECCN EAR99/NLR.

Dallas Aviation Field Service 24Hr. Helpdesk: (860) 565-0140


2701 Regent Blvd. Ste. 300 Fax: (860) 565-5442
Dallas, Texas 75261 e-mail: help24@pweh.com
FAA Repair Station #J8QR089X
Tel:. (972) 512-3698 Fax: (72) 512-3743

PW6000 BORESCOPE INSPECTION REPORT


W.O.# 905257 ENG. S/N: 318109 CUSTOMER: LAN
A/C TYPE: A318 MODEL: PW6122 LOCATION: Mexico City, Mexico
POSITION: 1 A/C REG: CC-CVP DATE: 7/12/2012
REASON: Customer request PERFORMED
Page 3 of 15 Ref. P&W Quote #: BY: Philip Romero
No out of limit defects noted.

DISPOSITION:
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00.
Inspection/Check -02

HIGH PRESSURE COMPRESSOR INSPECTION: Reference Aircraft MM Section 72-00-00


INLET GUIDE VANES (QTY48)
CONDITION:
No out of limit defects noted,

DISPOSITION:
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00
Inspection/Check -03

Form No.: INSP050 APP. BY:  Revision: 0 Date: 04/12/07


WARNING -- This document contains technical data the export of which is or may be restricted by the Export Administration Act and the Export Administration Regulations (EAR), 15 C.F.R. parts 730-774. Diversion contrary to U.S. law is prohibited. The export,
reexport, transfer or re-transfer of this technical data to any other company, entity, person, or destination, or for any use or purpose other than that for which the technical data was originally provided by P&W, is prohibited without prior written approval
from P&W and authorization under applicable export control laws.
EAR Export Classification: ECCN EAR99/NLR.

Dallas Aviation Field Service 24Hr. Helpdesk: (860) 565-0140


2701 Regent Blvd. Ste. 300 Fax: (860) 565-5442
Dallas, Texas 75261 e-mail: help24@pweh.com
FAA Repair Station #J8QR089X
Tel:. (972) 512-3698 Fax: (72) 512-3743

PW6000 BORESCOPE INSPECTION REPORT


W.O.# 905257 ENG. S/N: 318109 CUSTOMER: LAN
A/C TYPE: A318 MODEL: PW6122 LOCATION: Mexico City, Mexico
POSITION: 1 A/C REG: CC-CVP DATE: 7/12/2012
REASON: Customer request PERFORMED
Page 4 of 15 Ref. P&W Quote #: BY: Philip Romero

6TH STAGE BLADES (QTY 23)


BLADE CONDITION:
No out of limit defects noted.

DISPOSITION:
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00
Inspection/Check -03

6 STAGE VANES
TH

BLADE CONDITION:
No out of limit defects noted,

DISPOSITION:
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00.
Inspection/Check -03

Form No.: INSP050 APP. BY:  Revision: 0 Date: 04/12/07


WARNING -- This document contains technical data the export of which is or may be restricted by the Export Administration Act and the Export Administration Regulations (EAR), 15 C.F.R. parts 730-774. Diversion contrary to U.S. law is prohibited. The export,
reexport, transfer or re-transfer of this technical data to any other company, entity, person, or destination, or for any use or purpose other than that for which the technical data was originally provided by P&W, is prohibited without prior written approval
from P&W and authorization under applicable export control laws.
EAR Export Classification: ECCN EAR99/NLR.

Dallas Aviation Field Service 24Hr. Helpdesk: (860) 565-0140


2701 Regent Blvd. Ste. 300 Fax: (860) 565-5442
Dallas, Texas 75261 e-mail: help24@pweh.com
FAA Repair Station #J8QR089X
Tel:. (972) 512-3698 Fax: (72) 512-3743

PW6000 BORESCOPE INSPECTION REPORT


W.O.# 905257 ENG. S/N: 318109 CUSTOMER: LAN
A/C TYPE: A318 MODEL: PW6122 LOCATION: Mexico City, Mexico
POSITION: 1 A/C REG: CC-CVP DATE: 7/12/2012
REASON: Customer request PERFORMED
Page 5 of 15 Ref. P&W Quote #: BY: Philip Romero

7TH STAGE BLADES (QTY 44)


BLADE CONDITION:
No out of limit defects noted.

DISPOSITION:
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00.
Inspection/Check -03

7TH STAGE VANES


BLADE CONDITION:
No out of limit defects noted.

DISPOSITION:

Form No.: INSP050 APP. BY:  Revision: 0 Date: 04/12/07


WARNING -- This document contains technical data the export of which is or may be restricted by the Export Administration Act and the Export Administration Regulations (EAR), 15 C.F.R. parts 730-774. Diversion contrary to U.S. law is prohibited. The export,
reexport, transfer or re-transfer of this technical data to any other company, entity, person, or destination, or for any use or purpose other than that for which the technical data was originally provided by P&W, is prohibited without prior written approval
from P&W and authorization under applicable export control laws.
EAR Export Classification: ECCN EAR99/NLR.

Dallas Aviation Field Service 24Hr. Helpdesk: (860) 565-0140


2701 Regent Blvd. Ste. 300 Fax: (860) 565-5442
Dallas, Texas 75261 e-mail: help24@pweh.com
FAA Repair Station #J8QR089X
Tel:. (972) 512-3698 Fax: (72) 512-3743

PW6000 BORESCOPE INSPECTION REPORT


W.O.# 905257 ENG. S/N: 318109 CUSTOMER: LAN
A/C TYPE: A318 MODEL: PW6122 LOCATION: Mexico City, Mexico
POSITION: 1 A/C REG: CC-CVP DATE: 7/12/2012
REASON: Customer request PERFORMED
Page 6 of 15 Ref. P&W Quote #: BY: Philip Romero
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00.
Inspection/Check -03

8TH STAGE BLADES (QTY 71)


BLADE CONDITION:
Minor nicks are all within damage limits of
0.025” deep.

DISPOSITION:
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00.
Inspection/Check -03

8TH STAGE VANES


BLADE CONDITION:
No out of limit defects noted.

Form No.: INSP050 APP. BY:  Revision: 0 Date: 04/12/07


WARNING -- This document contains technical data the export of which is or may be restricted by the Export Administration Act and the Export Administration Regulations (EAR), 15 C.F.R. parts 730-774. Diversion contrary to U.S. law is prohibited. The export,
reexport, transfer or re-transfer of this technical data to any other company, entity, person, or destination, or for any use or purpose other than that for which the technical data was originally provided by P&W, is prohibited without prior written approval
from P&W and authorization under applicable export control laws.
EAR Export Classification: ECCN EAR99/NLR.

Dallas Aviation Field Service 24Hr. Helpdesk: (860) 565-0140


2701 Regent Blvd. Ste. 300 Fax: (860) 565-5442
Dallas, Texas 75261 e-mail: help24@pweh.com
FAA Repair Station #J8QR089X
Tel:. (972) 512-3698 Fax: (72) 512-3743

PW6000 BORESCOPE INSPECTION REPORT


W.O.# 905257 ENG. S/N: 318109 CUSTOMER: LAN
A/C TYPE: A318 MODEL: PW6122 LOCATION: Mexico City, Mexico
POSITION: 1 A/C REG: CC-CVP DATE: 7/12/2012
REASON: Customer request PERFORMED
Page 7 of 15 Ref. P&W Quote #: BY: Philip Romero

DISPOSITION:
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00
Inspection/Check -03

9TH STAGE BLADES (QTY 77)


BLADE CONDITION:
Minor nicks are all within damage limits of
0.025” deep.

DISPOSITION:
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00
Inspection/Check -03

9TH STAGE VANES


BLADE CONDITION:

Form No.: INSP050 APP. BY:  Revision: 0 Date: 04/12/07


WARNING -- This document contains technical data the export of which is or may be restricted by the Export Administration Act and the Export Administration Regulations (EAR), 15 C.F.R. parts 730-774. Diversion contrary to U.S. law is prohibited. The export,
reexport, transfer or re-transfer of this technical data to any other company, entity, person, or destination, or for any use or purpose other than that for which the technical data was originally provided by P&W, is prohibited without prior written approval
from P&W and authorization under applicable export control laws.
EAR Export Classification: ECCN EAR99/NLR.

Dallas Aviation Field Service 24Hr. Helpdesk: (860) 565-0140


2701 Regent Blvd. Ste. 300 Fax: (860) 565-5442
Dallas, Texas 75261 e-mail: help24@pweh.com
FAA Repair Station #J8QR089X
Tel:. (972) 512-3698 Fax: (72) 512-3743

PW6000 BORESCOPE INSPECTION REPORT


W.O.# 905257 ENG. S/N: 318109 CUSTOMER: LAN
A/C TYPE: A318 MODEL: PW6122 LOCATION: Mexico City, Mexico
POSITION: 1 A/C REG: CC-CVP DATE: 7/12/2012
REASON: Customer request PERFORMED
Page 8 of 15 Ref. P&W Quote #: BY: Philip Romero
No out of limit defects noted.

DISPOSITION:
Serviceable I/A/W PW6000 Maintenance Manual P/N
5407763 section 72-00-00 Inspection/Check -03

10TH STAGE BLADES (QTY 73)


BLADE CONDITION:
Minor nicks are all within damage limits of
0.025” deep.

DISPOSITION:
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00
Inspection/Check -03

10TH STAGE VANES


Form No.: INSP050 APP. BY:  Revision: 0 Date: 04/12/07
WARNING -- This document contains technical data the export of which is or may be restricted by the Export Administration Act and the Export Administration Regulations (EAR), 15 C.F.R. parts 730-774. Diversion contrary to U.S. law is prohibited. The export,
reexport, transfer or re-transfer of this technical data to any other company, entity, person, or destination, or for any use or purpose other than that for which the technical data was originally provided by P&W, is prohibited without prior written approval
from P&W and authorization under applicable export control laws.
EAR Export Classification: ECCN EAR99/NLR.

Dallas Aviation Field Service 24Hr. Helpdesk: (860) 565-0140


2701 Regent Blvd. Ste. 300 Fax: (860) 565-5442
Dallas, Texas 75261 e-mail: help24@pweh.com
FAA Repair Station #J8QR089X
Tel:. (972) 512-3698 Fax: (72) 512-3743

PW6000 BORESCOPE INSPECTION REPORT


W.O.# 905257 ENG. S/N: 318109 CUSTOMER: LAN
A/C TYPE: A318 MODEL: PW6122 LOCATION: Mexico City, Mexico
POSITION: 1 A/C REG: CC-CVP DATE: 7/12/2012
REASON: Customer request PERFORMED
Page 9 of 15 Ref. P&W Quote #: BY: Philip Romero

BLADE CONDITION:
No out of limit defects noted,

DISPOSITION:
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00
Inspection/Check -03

11TH STAGE BLADES (QTY 61)


BLADE CONDITION:
No out of limit defects noted.

DISPOSITION:
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00
Inspection/Check -03

Form No.: INSP050 APP. BY:  Revision: 0 Date: 04/12/07


WARNING -- This document contains technical data the export of which is or may be restricted by the Export Administration Act and the Export Administration Regulations (EAR), 15 C.F.R. parts 730-774. Diversion contrary to U.S. law is prohibited. The export,
reexport, transfer or re-transfer of this technical data to any other company, entity, person, or destination, or for any use or purpose other than that for which the technical data was originally provided by P&W, is prohibited without prior written approval
from P&W and authorization under applicable export control laws.
EAR Export Classification: ECCN EAR99/NLR.

Dallas Aviation Field Service 24Hr. Helpdesk: (860) 565-0140


2701 Regent Blvd. Ste. 300 Fax: (860) 565-5442
Dallas, Texas 75261 e-mail: help24@pweh.com
FAA Repair Station #J8QR089X
Tel:. (972) 512-3698 Fax: (72) 512-3743

PW6000 BORESCOPE INSPECTION REPORT


W.O.# 905257 ENG. S/N: 318109 CUSTOMER: LAN
A/C TYPE: A318 MODEL: PW6122 LOCATION: Mexico City, Mexico
POSITION: 1 A/C REG: CC-CVP DATE: 7/12/2012
REASON: Customer request PERFORMED
Page 10 of 15 Ref. P&W Quote #: BY: Philip Romero

11TH STAGE EXIT VANES


BLADE CONDITION:
No out of limit defects noted.

DISPOSITION:
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00
Inspection/Check -03

COMBUSTION CHAMBER INSPECTION: Reference Aircraft MM Section 72-00


COMBUSTION CHAMBER
CHAMBER CONDITION:
No out of limit defects noted.

DISPOSITION:

Form No.: INSP050 APP. BY:  Revision: 0 Date: 04/12/07


WARNING -- This document contains technical data the export of which is or may be restricted by the Export Administration Act and the Export Administration Regulations (EAR), 15 C.F.R. parts 730-774. Diversion contrary to U.S. law is prohibited. The export,
reexport, transfer or re-transfer of this technical data to any other company, entity, person, or destination, or for any use or purpose other than that for which the technical data was originally provided by P&W, is prohibited without prior written approval
from P&W and authorization under applicable export control laws.
EAR Export Classification: ECCN EAR99/NLR.

Dallas Aviation Field Service 24Hr. Helpdesk: (860) 565-0140


2701 Regent Blvd. Ste. 300 Fax: (860) 565-5442
Dallas, Texas 75261 e-mail: help24@pweh.com
FAA Repair Station #J8QR089X
Tel:. (972) 512-3698 Fax: (72) 512-3743

PW6000 BORESCOPE INSPECTION REPORT


W.O.# 905257 ENG. S/N: 318109 CUSTOMER: LAN
A/C TYPE: A318 MODEL: PW6122 LOCATION: Mexico City, Mexico
POSITION: 1 A/C REG: CC-CVP DATE: 7/12/2012
REASON: Customer request PERFORMED
Page 11 of 15 Ref. P&W Quote #: BY: Philip Romero
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00
Inspection/Check -04

1ST STAGE NOZZLE GUIDE VANES


CONDITION:
Multiple vanes have thermal barrier coating
missing. One Vane has 6 cracks that measure,
0.084, 0.074, 0.054, 0.087, 0.079, & 0.209
inches in length.

DISPOSITION:
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00
Inspection/Check-04 as amended by E.A.
EM12MC029. Any quantity of cracks up to .150
and up to 3 cracks with a maximum length of
.250 are permitted.
Reference E.A. EM12MC029

HIGH PRESSURE TURBINE INSPECTION: Reference Aircraft MM Section 72-00-00


1 STAGE TURBINE BLADES (QTY 60)
ST

BLADE CONDITION:
Some thermal barrier coating is missing. No
burning of parent material observed.

DISPOSITION:

Form No.: INSP050 APP. BY:  Revision: 0 Date: 04/12/07


WARNING -- This document contains technical data the export of which is or may be restricted by the Export Administration Act and the Export Administration Regulations (EAR), 15 C.F.R. parts 730-774. Diversion contrary to U.S. law is prohibited. The export,
reexport, transfer or re-transfer of this technical data to any other company, entity, person, or destination, or for any use or purpose other than that for which the technical data was originally provided by P&W, is prohibited without prior written approval
from P&W and authorization under applicable export control laws.
EAR Export Classification: ECCN EAR99/NLR.

Dallas Aviation Field Service 24Hr. Helpdesk: (860) 565-0140


2701 Regent Blvd. Ste. 300 Fax: (860) 565-5442
Dallas, Texas 75261 e-mail: help24@pweh.com
FAA Repair Station #J8QR089X
Tel:. (972) 512-3698 Fax: (72) 512-3743

PW6000 BORESCOPE INSPECTION REPORT


W.O.# 905257 ENG. S/N: 318109 CUSTOMER: LAN
A/C TYPE: A318 MODEL: PW6122 LOCATION: Mexico City, Mexico
POSITION: 1 A/C REG: CC-CVP DATE: 7/12/2012
REASON: Customer request PERFORMED
Page 12 of 15 Ref. P&W Quote #: BY: Philip Romero
Serviceable I/A/W PW6000 Engine Maintenance Manual
P/N 5407763 section 72-00-00-Inspections check 05.
Permitted for regular inspection interval.

1 STAGE TURBINE DUCT SEGMENTS


ST

BLADE CONDITION:
No out of limit defects noted.

DISPOSITION:
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00
Inspection/Check -05

LOW PRESSURE TURBINE INSPECTION: Reference Aircraft MM Section 72-00-00


2ND STAGE BLADES (QTY 110)
BLADE CONDITION:

Form No.: INSP050 APP. BY:  Revision: 0 Date: 04/12/07


WARNING -- This document contains technical data the export of which is or may be restricted by the Export Administration Act and the Export Administration Regulations (EAR), 15 C.F.R. parts 730-774. Diversion contrary to U.S. law is prohibited. The export,
reexport, transfer or re-transfer of this technical data to any other company, entity, person, or destination, or for any use or purpose other than that for which the technical data was originally provided by P&W, is prohibited without prior written approval
from P&W and authorization under applicable export control laws.
EAR Export Classification: ECCN EAR99/NLR.

Dallas Aviation Field Service 24Hr. Helpdesk: (860) 565-0140


2701 Regent Blvd. Ste. 300 Fax: (860) 565-5442
Dallas, Texas 75261 e-mail: help24@pweh.com
FAA Repair Station #J8QR089X
Tel:. (972) 512-3698 Fax: (72) 512-3743

PW6000 BORESCOPE INSPECTION REPORT


W.O.# 905257 ENG. S/N: 318109 CUSTOMER: LAN
A/C TYPE: A318 MODEL: PW6122 LOCATION: Mexico City, Mexico
POSITION: 1 A/C REG: CC-CVP DATE: 7/12/2012
REASON: Customer request PERFORMED
Page 13 of 15 Ref. P&W Quote #: BY: Philip Romero
No out of limit defects noted.

DISPOSITION:
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00.
Inspection/Check -06

2 STAGE VANES
ND

BLADE CONDITION:
No out of limit defects noted.

DISPOSITION:
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00
Inspection/Check -06

4 STAGE TURBINE BLADES (QTY 92)


TH

Form No.: INSP050 APP. BY:  Revision: 0 Date: 04/12/07


WARNING -- This document contains technical data the export of which is or may be restricted by the Export Administration Act and the Export Administration Regulations (EAR), 15 C.F.R. parts 730-774. Diversion contrary to U.S. law is prohibited. The export,
reexport, transfer or re-transfer of this technical data to any other company, entity, person, or destination, or for any use or purpose other than that for which the technical data was originally provided by P&W, is prohibited without prior written approval
from P&W and authorization under applicable export control laws.
EAR Export Classification: ECCN EAR99/NLR.

Dallas Aviation Field Service 24Hr. Helpdesk: (860) 565-0140


2701 Regent Blvd. Ste. 300 Fax: (860) 565-5442
Dallas, Texas 75261 e-mail: help24@pweh.com
FAA Repair Station #J8QR089X
Tel:. (972) 512-3698 Fax: (72) 512-3743

PW6000 BORESCOPE INSPECTION REPORT


W.O.# 905257 ENG. S/N: 318109 CUSTOMER: LAN
A/C TYPE: A318 MODEL: PW6122 LOCATION: Mexico City, Mexico
POSITION: 1 A/C REG: CC-CVP DATE: 7/12/2012
REASON: Customer request PERFORMED
Page 14 of 15 Ref. P&W Quote #: BY: Philip Romero

BLADE CONDITION:
No out of limit defects noted.

DISPOSITION:
Serviceable I/A/W PW6000 Engine Maintenance
Manual P/N 5407763 section 72-00-00.
Inspection/Check -06

ADDITIONAL COMMENTS/PICTURES:

Form No.: INSP050 APP. BY:  Revision: 0 Date: 04/12/07


WARNING -- This document contains technical data the export of which is or may be restricted by the Export Administration Act and the Export Administration Regulations (EAR), 15 C.F.R. parts 730-774. Diversion contrary to U.S. law is prohibited. The export,
reexport, transfer or re-transfer of this technical data to any other company, entity, person, or destination, or for any use or purpose other than that for which the technical data was originally provided by P&W, is prohibited without prior written approval
from P&W and authorization under applicable export control laws.
EAR Export Classification: ECCN EAR99/NLR.

Dallas Aviation Field Service 24Hr. Helpdesk: (860) 565-0140


2701 Regent Blvd. Ste. 300 Fax: (860) 565-5442
Dallas, Texas 75261 e-mail: help24@pweh.com
FAA Repair Station #J8QR089X
Tel:. (972) 512-3698 Fax: (72) 512-3743

PW6000 BORESCOPE INSPECTION REPORT


W.O.# 905257 ENG. S/N: 318109 CUSTOMER: LAN
A/C TYPE: A318 MODEL: PW6122 LOCATION: Mexico City, Mexico
POSITION: 1 A/C REG: CC-CVP DATE: 7/12/2012
REASON: Customer request PERFORMED
Page 15 of 15 Ref. P&W Quote #: BY: Philip Romero

Customer was tasked to remove and install all the borescope plugs.

SIGNATURE: DATE:
7/15/2012

Form No.: INSP050 APP. BY:  Revision: 0 Date: 04/12/07