NOTES: NOTES:

FLOW SIGNAL 869-U-1004


6. CHEMICAL INJECTION PACKAGE WHICH IS NOT ENCLOSED WITHIN A. FOR STANDARD SYMBOLS/ LEGEND AND TYPICAL DETAIL
857 TA-249812-007 ANTIFOAM INJECTION PACKAGE A BUILDING SHALL BE PROVIDED WITH A SHELTER TO MINIMISE SEE DRAWINGS TA-249760-001 TO TA-249762-005.
FROM LEAN AMINE DUTY: 2.7 HP THE INGRESS OF STORMWATER. (TD-071006 PARA.11.2)
FLOW FC-1244 NOTE 3, 4, 5, 6 B. THE SRU FEATURES 3 TRAINS. THIS DRAWING IS FOR TRAIN 1
7. BUND MATERIAL TO BE SUITABLE FOR ALL CHEMICALS. ONLY. THE CORRESPONDING TRAIN 2 & 3 CONFIGURATION IS
ANTIFOAM IDENTICAL WITH THE EXCEPTION THAT THE FIRST DIGIT IN
FLOW DEMAND 8. 2 X 100% (DUTY / STANDBY) ANTIFOAM METERING PUMPS. THE SEQUENCE NUMBER "1XXX" IS REPLACED WITH "2XXX" OR
SELECTOR RATIO X
FLOW SIGNAL "3XXX" IN THE EQUIPMENT TAG. ALL INSTRUMENT TAG NUMBERS
FHS FY 9. 1EA OFF TANK MIXER WITH MOTOR DRIVER. ON THIS P&ID SHALL BE PREFIXED WITH '869-100-' (UNLESS
933 TA-249812-010 OTHERWISE NOTED). TRAIN 2 INSTRUMENT TAG NUMBERS
3200 3200
FROM RICH AMINE 10. AIR DRIVEN PUMP. SHALL BE PREFIXED WITH '869-200-' AND HAVE SEQUENCE
FLOW FI-1267 C C
NUMBERS FROM 1001 ONWARDS. TRAIN 3 INSTRUMENT TAG
11. PUMP STROKE WILL BE ADJUSTABLE TO ALLOW FLOW CONTROL. NUMBERS SHALL BE PREFIXED WITH '869-300-' AND HAVE
THIS WILL BE AUTOMATIC. SEQUENCE NUMBERS FROM 1001 ONWARDS. ZC TAGS SHALL
HAVE SEQUENCE NUMBERS FROM 001 ONWARDS, THAT REMAIN
12. NON-SLAM INTERNAL SPRING ASSISTED TYPE CHECK VALVE. THE SAME IN EACH TRAIN.
FLOW SIGNAL
940 TA-249812-013 13. DIAPHRAGM FAILURE SIGNAL. 1. DISTRIBUTION AND MANIFOLDS TO BE CONFIRMED LATER.
FROM SOUR WATER
FLOW FY-XXXX
HOLD 2 2. ANTI-FOAM ROUTED TO ONE LOCATION AT A TIME.
TA-249813-009 HOLDS:
CC 3. ANTIFOAM INJECTION PACKAGE SHOWN IS TYPICAL.
1. 869-U-1004 PACKAGE DETAIL DESIGN. VENDOR TO SUPPLY ACTUAL.
974
2. TYPE OF WATER FOR CHEMICAL DILUTION. 4. P&ID TO BE UPDATED TO REFLECT / CONVERT VENDOR'S
DRAWINGS. IF ADDITIONAL DRAWINGS ARE NEEDED, THIS P&ID

2"-CC-10091-1CS2U01
DUTY/STANDBY MUST BE UPDATED TO REFERENCE NEW DRAWINGS.
HS SELECTOR
C 3200 5. MAX. DOSING RATE IS 25 LB/HR. DETAILS ARE TO BE CONFIRMED
WITH VENDOR.

H H H NOTE 11 NOTE 11 H LEGEND


FI PI PI PI HIC HIC LI
C PIPING MATERIAL
C 3200 3202 3201 3200 C 3200 3201 3200 INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
L L C C C L SPECIFICATION SAES-L-105
AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT

C NOTE 13 NOTE 13 AIR FAILURE OPEN VS -VIBRATION SWITCH


PROCESS LINE AC/AFS -AIR TO CLOSE/AIR VT -VIBRATION TRANSMITTER
FAILURE STEADY
INSTRUMENT XL -PILOT LIGHT
AIR LINE AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
AIR FAILURE CLOSE LS -LIMIT SWITCH
ELECTRIC SIGNAL ZC -SHUTDOWN LOGIC
AO/AFS -AIR TO OPEN/AIR
CAPILLARY TUBING FAILURE STEADY ZV -SAFETY SHUTDOWN VALVE
CONTRACTOR SOFTWARE LINK AOV -ON-OFF VALVE
ZBV -EMERGENCY BLOWDOWN VALVE
VENDOR VENDOR PACKAGE WIRELESS SIGNAL AT -ANALYZER TRANSMITTER
869-U-1004 HYDRAULIC SIGNAL
ESD -EMER. SHUTDOWN SYSTEM
DATA LOGGER POINT
F-FLOW P-PRESS.

INPUTS

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
FC - FLOW CONTROLLER
NOTE 3, 4 FICV - FLOW INDICATING REGULATOR
L-LEVEL T-TEMP.
PIPING MATERIAL CLASS X-MISC. A-ALARM
BREAK FV -FLOW CONTROL VALVE
LOCAL PANEL
FCV -FLOW CONTROL VALVE MOUNTED INSTR.
INSULATION BREAK (SELF-ACTUATED)
AG UG ABOVE GROUND / FE -FLOW ELEMENT CONSOLE MOUNTED
UNDERGROUND BREAK FG -FLOW SIGHT GLASS INSTRUMENT
FHV -FLOW MANUAL CONT. VALVE
MAX DESIGN PRESSURE FM -FLOW METER
R/G
XL STATUS LIGHTS
AND TEMPERATURE
FO -RESTRICTION ORIFICE
20238 1"-C-1000-1SD0U01 BREAK
FQI -FLOW TOTALIZER INDICATOR
R=RED, G=GREEN
PILOT LIGHT (DO NOT
MAX OPERATING PRESSURE
C NOTE 2 NNF AND TEMPERATURE
FR -FLOW RECORDER USE FOR MOTOR STATUS)
FIT -FLOW TRANSMITTER
TA-249812-007 BREAK
FY -FLOW RELAY
MOTOR STATUS
ML
TO AMINE ABSORBER SUPPLY GWR -GUIDED WAVE RADAR
PILOT LIGHT
869-C-1002 NOTE 1 RESPONSIBILITY
HC -HAND CONTROLLER
BREAK LOCAL MOUNTED
HS -HAND SWITCH INSTRUMENT
PORTABLE TRANSFER PUMP END OF LINE LA -LEVEL ALARM
20254 1"-C-1001-1SD0U01 (AIR OPERATED) LV -LEVEL CONTROL VALVE MOUNTED BEHIND
LCV -LEVEL CONTROL VALVE LOCAL PANEL
C NOTE 2 NNF PZV DETAIL 8 REDUCER
FF FF + (SELF-ACTUATED)
TA-249812-011 C FIT PIT 3200 FP/CSO (BULK CONTRAINER) LG -LEVEL GAUGE RACK MOUNTED
C C FREE DRAINING RING SPACER LC -LEVEL CONTROLLER (OR BACK OF PANEL)
TO AMINE REGENERATOR 3202 UNLOADING
3200 INST. TO SAFE LI -LEVEL INDICATOR
869-C-1003 FE C 1" D 1" D LR -LEVEL RECORDER INSTRUMENT
C PIPING LOCATION BLIND-CLOSED
NOTE 10
+
LS -LEVEL SWITCH AIR SUPPLY REQUIRED
3200 LIT LIT -LEVEL TRANSMITTER
20312 1"-C-1002-1SD0U01 3200 GATE VALVE ML -MOTOR STATUS LIGHT ELECTRICAL
SUPPLY REQUIRED
C NOTE 2 NNF FP/CSO M GLOBE VALVE
MOV
NCR
-MOTOR OPERATED VALVE
-NON-CONTACT RADAR
H
TA-249812-013 CHECK VALVE PB -PUSHBUTTON HIGH LOW
TO AMINE REGENERATOR PC -PRESSURE CONTROLLER L
PLUG VALVE
869-C-1003 PV -PRESS. CONTROL VALVE
FF
PCV -PRESS. CONTROL VALVE
BALL VALVE FOUNDATION
(SELF ACTUATED) FIELDBUS INSTRUMENT
DOUBLE DISC PDC -PRESS. DIFF. CONTROLLER
GATE VALVE PDI -PRESS. DIFF. INDICATOR
PDIS -PRESSURE DIFFERENTIAL
ANGLE VALVE INDICATOR SWITCH
PDIT -PRESS. DIFF. TRANSMITTER
DISTRIBUTED CONTROL/SHARED
PRESS RELIEF PG -PRESSURE GAGE
PI
DISPLAY SYMBOLS
VALVE -PRESSURE INDICATOR
PR -PRESSURE RECORDER (DCS) DISTRIBUTED CONTROL
VACUUM RELIEF PS -PRESSURE SWITCH SYSTEM, OPERATOR ACCESSIBLE
LG VALVE PIT -PRESSURE TRANSMITTER IN CONTROL ROOM
PP -PRESSURE POINT (DCS) DISTRIBUTED CONTROL
3201 M MOTOR OPERATED PY -PRESS. COMPUTATION MOD. SYSTEM, OPERATOR INACCESSIBLE
C VALVE PZE -RUPTURE DISK IN CONTROL ROOM
PZV -PRESSURE RELIEF VALVE
PISTON OPERATED (DCS) DISTRIBUTED CONTROL
RTD -RESIST. TEMP. DETECTOR SYSTEM, OPERATOR ACCESSIBLE
VALVE
SC -SPEED CONTROLLER IN FIELD
NOTE 9 H
HYDRAULIC OPERATED
SI -SPEED INDICATOR
LOCAL DCS OR AUXILIARY
SE
100-ZC-001 VALVE
-SPEED ELEMENT
DCS LOCATION NORMALLY
SSV -SURFACE SAFETY VALVE
100-ZC-004 TG ACCESSIBLE TO OPERATOR
100-ZC-209 ZC CONTROL VALVE SSSV -SUB-SURFACE SAFETY VALVE

100-ZC-210 3200 ST -SPEED TRANSMITTER


208 BALL TYPE TC -TEMP. CONTROLLER PROGRAMMABLE LOGIC
100-ZC-212 CONTROL VALVE
C TV -TEMP. CONTROL VALVE CONTROLLER WITH BINARY
100-ZC-233 WITH POSITIONER TCV -TEMP. CONTROL VALVE OR SEQUENTIAL FUNCTIONS
S (SELF-ACTUATED)
SOLENOID VALVE (PLC) PROGRAMMABLE LOGIC
DETAIL 7 TE -TEMP. ELEMENT CONTROLLER, NORMALLY
TG -TEMPERATURE GAUGE INACCESSIBLE OR BEHIND THE
VALVE NORMALLY TI -TEMP. INDICATOR PANEL DEVICE OR FUNCTIONS
1" CLOSED TS -TEMP. SWITCH (PLC) PROGRAMMABLE LOGIC
IBT - INVERTED BUCKET TKV -TUBING KILL VALVE CONTROLLER FUNCTION,
D FF STEAM TRAP TIT -TEMP. TRANSMITTER CAN BE NORMALLY
TW -THERMOWELL
PIT TSO -TIGHT SHUT OFF DISPLAYED ON CRT
2" UC -SEQUENCE / LOGIC CONTROL
NOTE 12
FREE DRAINING

S.C. - SAMPLE CONN. (PLC) PROGRAMMABLE LOGIC


PULSATION 3200
NO POCKETS

C S -DRAIN TO CONTROLLER I/O POINT


PG DAMPER
C
M PDI PRESSURE SEWER NORMALLY INACCESSIBLE
BY OPERATOR
3200 3200 OWS -OILY WATER SEWER
INST. INST. D -DRAIN
C
PIPING PIPING V -VENT

REFERENCE DRAWINGS
LETTER IDENTIFICATION OF LINES AD-036204
PIPING SYMBOLS AB-036227
1" D
EQUIPMENT SYMBOLS AB-036305
NOTE 8 INSTRUMENT SYMBOLS AC-036950
PIPING LAYOUT INDEX
PLOT PLAN
2"
PROCESS FLOW DIAGRAM
PZV HYDROSTATIC TEST DIAGRAM
+

3201 FP/CSO DRAWING CONTROL FOR J.O.


C
INSTRUMENT INSTALLATION SCHEDULES
FREE DRAINING
DETAIL 7

1"
C 04/29/22
D FP/CSO
FF
B 03/17/22
PIT
NOTE 12
FREE DRAINING

PULSATION 3201
NO POCKETS

C 2"
A 01/24/22
PG DAMPER
C M PDI
REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY
3201 3201
INST. INST. REVISION VALIDATION
PIPING C PIPING
THIS REVISION NO. C IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
NOTE 2 10-14329-0003-001
1" D
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
NOTE 8 (DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
SIH MWK
04/29/22 04/29/22

REV.NO. DATE REVISION DESCRIPTION


C 04/29/22 ISSUED FOR DESIGN

JOB ORDER NO.


THIS REVISION IS NOT TO BE USED FOR
10-14329-0003 CONSTRUCTION UNTIL CERTIFIED AND DATED
C
NOTE 7 SAUDI ARABIAN OIL COMPANY
DRAWING TYPE
PIPING & INSTRUMENTATION DIAGRAM PID
2"-OWS-10110-1CS2P01
ANTIFOAM INJECTION PACKAGE - TRAIN 1
JFGP SULFUR RECOVERY & TAIL GAS
JAFURAH SAUDI ARABIA
OWS PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

869 A TA-249813 020 C


AFW DOC NO: TA-249813-020 CLASS: 1 REV: C DSN: Saudi Aramco 5994 ENG. (02/07)