You are on page 1of 1

DELTA TESTING AND RESEARCH LABORATORIES

Plot No.- C-5 Block ''C" Main Kanjawala Road,


Rajiv Nagar, New Delhi. 110086.

Steel tensile(round)Report
Job Order No. DTRL/200123020371 Date of Testing 2023-01-24
Sample Desc. COUPLER 16MM

Area Original gauge s dia in mm


in mm^2 in mm

201.21 509.00 --

Density Max Load Tensile Strength Yield Load


in g/cm^3 in kN in Mpa in kN
-- 124.0 616.2 102.32

Yield Strength Gauge After Total Elongation Elongation


in Mpa fracture After Fracture After fracture
in mm in mm in %
508.5 547.49 38.49 7.56
CurveGraph
130
120
110
100
90
Load

80
70
(kN)

60
50
40
30
20
10
0
0 5 10 15 20 25 30 35 40 45 50 55
Displacement (mm)

Tested By Checked By