Professional Documents
Culture Documents
325b 8FN01822 TASSISA Parameter Status Checks-1
325b 8FN01822 TASSISA Parameter Status Checks-1
Page 1 of 6
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 325B LN EXCAVATOR 8FN01822
Configuration: 325B & 325B LN Excavators 8FN00001-UP (MACHINE) POWERED BY 3116 Engine
i01255665
11Lo - This display indicates that the low temperature control is activated.
Engine RPM
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/... 8/16/2023
325B & 325B LN Excavators 8FN00001-UP (MACHINE) POWERED B... Page 2 of 6
Enter service code 12. The four characters on the right side of the display indicates the
actual engine rpm.
Digital Input
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/... 8/16/2023
325B & 325B LN Excavators 8FN00001-UP (MACHINE) POWERED B... Page 3 of 6
Illustration 1 g00662945
Monitor Panel
This Service mode is used in order to check the ON/OFF inputs of the controller from
various switches and sending units of the machine.
1. Enter service code 16. The character display will display the port number first.
Then, the display will show the condition of the port.
2. The fine control mode switch (25) is pressed in order to shift the position of the
character display that is blinking to the third character position from the right. The
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/... 8/16/2023
325B & 325B LN Excavators 8FN00001-UP (MACHINE) POWERED B... Page 4 of 6
boom priority mode switch (23) or the swing priority mode switch (24) is pressed
in order to change the port number that is blinking.
1611 - This message indicates port No. 1 and the engine speed dial is at position
1.
162 on - This message indicates port No. 2 and the implement pressure switch is
ON.
162 oF - This message indicates port No. 2 and the implement pressure switch is
OFF.
In order to scroll through the remaining switches and indicators, you should push the
boom priority switch (23). This action will allow you to proceed through the numbers.
You may also push the swing priority switch (24) to reverse through the numbers. The
two center characters indicate the switch or the indicator. The two right characters
indicate the status of the switch or the indicator. The right characters will display "On",
if a switch or an indicator is activated. The right characters will display "oF", if the
switch is not activated. The following chart is a list of the different pressure switches
and sending units.
Table 1
Monitor Reading Switch Number
Component Description
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/... 8/16/2023
325B & 325B LN Excavators 8FN00001-UP (MACHINE) POWERED B... Page 5 of 6
Software Version
1. Enter service code 17. The character display shows a code of each software first.
Then, the software version is shown.
2. The fine control mode switch (25) is pressed in order to shift the character
position of the character display that is blinking to the fourth position from the
right.
3. The boom priority mode switch (23) or the swing priority mode switch (24) is
pressed in order to change a code of software that is flashing.
a. When the boom priority mode switch (23) is depressed, the code will change
from "A" to "b".
b. When the swing priority mode switch (24) is depressed, the code will change
from "b" to "A".
"17 A0 0H"
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/... 8/16/2023
325B & 325B LN Excavators 8FN00001-UP (MACHINE) POWERED B... Page 6 of 6
"17 b0 70"
Enter service code 20. The character display displays the power shift pressure in the
remaining four characters in the unit of kPa.
The system pressures cannot be changed in this mode. This mode is used to check the
current pressure of the main hydraulic system. The pressures from the attachments
pumps cannot be checked by using this mode.
Copyright 1993 - 2023 Caterpillar Inc. Wed Aug 16 07:19:17 UTC+0300 2023
All Rights Reserved.
Private Network For SIS Licensees.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/... 8/16/2023