You are on page 1of 64

Catalogue

1、Overview ................................................................................................
................................ ......................................... 1
1.1 Preface ................................................................................................
................................ .....................................1
1.2 Purpose ................................................................................................
................................ ....................................1
1.3 Safety Instructions ................................................................
....................................................1
2、System
System Brief Description ................................................................
.................................................2
3、System Function................................
..............................................................................................
..............................3
4、System Structure................................
.............................................................................................
.............................4
5、System
System Components ................................................................
.......................................................4
6、Operation method................................
............................................................................................
............................6
6.1 Layout and Description of Operation Panel ................................
..............................................6
6.1.1 Three-levellevel alarm status indication ................................
..................................................6
6.1.2 Work and Fault Indication................................................................
Indication ................................6
6.1.3 Dormant Time................................................................
Time ..................................................7
6.1.4 Watch Mode ................................................................
....................................................7
6.1.5 Reset/Call................................................................
Reset/Call ........................................................8
6.1.6 Dimming and Key ................................................................
............................................8
6.1.7 Key switch ................................................................
.......................................................8
6.2 Operation Settings ................................................................
....................................................9
6.2.1 Dormant time settings and protection ................................
..............................................9
6.2.2 Duty time setting and protection ................................
......................................................9
6.2.3 Reserve duty personnel selection ................................
...................................................9
6.2.4 System self-test................................................................
self ...............................................9
6.3 Alarm mode setting................................................................
setting ...................................................9
6.3.1 Alarm mode setting of 2nd. And 3rd. level................................
.......................................9
6.3.2 Delay the interval time for 2nd and 3rd alarm................................
alarm ................................10
6.4 Infrared and microwave motion detection function................................
function..................................10
6.5 Special Remind................................
.......................................................................................
.......................10
6.6 Bridge navigational Watch Alarm system/Nautical Equipment Fault
Alarm Operation method (Only touch screen version has this function) .......11
6.6.1 Layout and Description of Operation Panel ................................
...................................11
6.6.2 Emergency Call ................................................................
.............................................13
6.6.3 Key Switch................................................................
Switch .....................................................13
7、System
System Maintenance................................................................
Maintenance .....................................................14
8. Guidelines for BNWAS Installation................................................................
Installation ..................................16
9、Accessory................................
................................................................................................
......................................17
Drawing and operating instructions................................................................
instructions .....................................18
1、 Overview
1.1 Preface

The new generation of HAPCON® bridge navigational watch alarm system (HTC-BNW)

has been developed and manufactured according to MSC128.(75) of IMO and IEC62616. It

can be easily used in a variety of ships’ building and old vessels to renew with it’s compact

shape, stable and reliable control system.

This operation manual described the standard configuration of bridge navigational watch

alarm system. Specific system may contain more components with extended function, its

composition and description can be referred in specific manual.

1.2 Purpose

The purpose of this manual is designed to help operators on ship to understand the basic

functions and principles of the bridge navigational watch alarm system, so the operators can

operate the system correctly.

1.3 Safety Instructions

 PERSONNEL

Repair and maintenance personnel must be trained by our company. The maintenance

personnel should be informed that the possible faults and read the relevant security

instructions before inspection.

 ATTENTION

Operators must ensure that equipment should be in normal working status before

using the equipment

 Preventing water into the equipment

 Please cutting off the device power supply immediately when equipment is found

smoking or emitted abnormal smell.

 Preventing any sundries to enter into the device.

1
2、System Brief Description
The bridge navigational watches alarm system can ascertain the status of duty officer and

monitoring the duty officer’s good vigilance. Turn the key switch to start-up system, you have

three selection mode:” Manual off mode”, ” Manual on mode”” Automatic mode”. Under”

Manual off mode”, System does not run in any status; Under ”Manual on mode”, the time

showed on digital tube will be countdown from the initial default of 3 minutes. When the

countdown to zero, operation panel and the light(s) on Reset Board flashing to pre-alarm. It

appearsⅠ-level sound and light alarm if pre-alarm continued up to 15 seconds and Reset

button is not pressed.Ⅱ-level sound and light alarm will appears if Ⅰ-level sound and light

alarm continued up to 15 seconds and Reset button is not pressed. Ⅲ-level sound and light

alarm will appears if Ⅱ-level sound and light alarm continued up to 90 seconds and Reset

button is not pressed,that is, all indicator lights on Reset Board and Extension Alarm Board will

appears sound and light alarm, until the Reset Button is pressed. When the Reset Button is

pressed, the system re-timing and starts the next cycle .Under” Automatic mode”, system

waits for the signals from autopilot and working steering to enable the equipment e, start a new

normal countdown working state. At the same time, the system can receive the signals from

radar, VDR, Electronic Chart and motion detection etc,, the system can reset the dormant

time.

Bridge Navigational Watch Alarm System Action Sequence Diagram

2
3、System Function
 Dormant time countdown function. Setting range: 3 mins. to 12mins.

 Operational Mode: Manual off、Manual on 、Automatic changing-over.

 3 level extension alarm.

 Emergency call function.

 Selection of reserve duty person (four choose one)

 System self test function.

 Infrared and microwave motion detection function

 Dimming function.

 Fault Output function of system and power.

 AC220(AC110V) power supply, switch to standby power automatically while the

main power appears failure

 Radar , electronic charts and other navigational equipments Lose power fault, sound

and light alarm will give out(Only touch screen version of this function)

 Configuring Standard serial interface with VDR.

3
4、System Structure

MOTION SENSOR
HTC-BNW-114 OUTPUT:POWER FAIL/SYSTEM ACTIVE/FAIL/ALARM STAGE
To VDR、GA &PA SYSTEM
INPUT:AUTOPILOT(AUTO-ON)
RADIO、AUTOPILOT、ECDIS(RESET
RESET)

RESET UNIT
HTC-BNW-111

POWER UNIT
HTC-BNW-115
CONTROL PANEL
I/O UNIT
HTC-BNW-110
HTC-BNW-113

PORT、STARBOARD
STARBOARD WING NAVI.DECK

EXTENSION ALARM UNIT


HTC-BNW-112

CAPTAIN CHIEF OFF 2ND OFF 3RD OFF OFF’S MESS CONFERENCE ROOM

5、System Components
The model named and defining method

HTC – BNW – 110 – A 1–T

Touch screen
Hapcon marine
automation products
1 IP22

BNWAS 2 IP56

A Panel Mount
110 operation unit
B Wall Mount
111 reset unit

112 alarm unit

113 I/O unit

114 Motion detection unit

115 power unit

4
Power Protection
Number Name Type Installing mode
source grade

Operation
1 HTC-BNW-110-A1 DC24V IP22 Panel Mount
Unit

Operation
HTC-BNW-110-B1
2 Unit DC24V IP22 Wall Mount
(HTC-BNW-113)
+I/O Unit

Operation
3 HTC-BNW-110-A1-T DC24V IP22 Panel Mount
Unit

Operation
4 HTC-BNW-110-B1-T DC24V IP22 Wall Mount
Unit

5 Reset Unit HTC-BNW-111-B1 DC24V IP22 Wall Mount

6 Reset Unit HTC-BNW-111-B2 DC24V IP56 Wall Mount

7 Reset Unit HTC-BNW-111-A1 DC24V IP22 Panel Mount

8 Reset Unit HTC-BNW-111-A2 DC24V IP56 Panel Mount

9 Alarm Unit HTC-BNW-112-B1 DC24V IP22 Wall Mount

10 Alarm Unit HTC-BNW-112-A1 DC24V IP22 Panel Mount

11 I/O Unit HTC-BNW-113 DC24V IP22 Wall Mount

Motion
12 HTC-BNW-114 DC24V IP22 Wall Mount
detection

AC220V
13 Power Unit HTC-BNW-115 IP22 Wall Mount
AC110V

5
6、 Operation method
6.1 Layout and Description of Operation Panel

Operation Panel is divided into 6 functional areas

6.1.1 Three-level alarm status indication

Pre-alarm: From dormant time to pre-alarm flash

indication

Ⅰlevel alarm: Bridge navigationⅠlevel alarm

Ⅱlevel alarm: Reserve duty Ⅱlevel extension alarm

Ⅲ level alarm: Extension Alarm of all sound and light

alarm

6.1.2 Work and Fault Indication

Bridge navigational watch alarm system is in working status

Main Power fault indication

Reserve Power fault indication

System self-trouble indication

6
6.1.3 Dormant Time

When system is in normal working status, digital tube

displays the remaining time to the end of the dormant time

Unit: minute.

Change dormant time setting Incre. /Decre. To avoid the data

setting is modified, this time setting is only valid in 30

seconds after the key switch is turned from OFF to ON.

6.1.4 Watch Mode

System is in manual starting status when manual operational 0ff

indicator is on.

System is in manual starting status when manual operational on

indicator is on.

System is started by steering device or autopilot when

automatic operation indicator is on.

(Mode) key is used to change over between

Manual/Automatic mode

Backup duty officer choose one in four

The general default is

1、Captain

2、Chief officer

3、Second officer

4、Third officer

7
6.1.5 Reset/Call

Reset key: pressing this key back to the dormant

time setting and restart the countdown.

Emergency call key: pressing this button,Ⅱand Ⅲ level

alarm can be started directly as emergency call function.

6.1.6 Dimming and Key

Dimming function key

(up) Light intensity increases

(down ) Light intensity dimming

6.1.7 Key switch

The key on ”OFF”position, the system is locked in not work status,.

The key turn from “OFF” to “ON”, In the 30s watch

mode and dormant time can be set. 30s later, system

starts to work depending on the setting.

8
6.2 Operation Settings

6.2.1 Dormant time settings and protection

Turn the key from ”OFF” to “ON’, press “+” or“–” to increase or decrease

the setting value of dormant time within 30 seconds. Setting range:3 minutes~

12minutes,you cannot set the value out of the range.

6.2.2 Duty time setting and protection

Turn the key from ”OFF” to “ON’, press “MODE” key to switch duty mode

to automatic mode within 30 seconds.

6.2.3 Reserve duty personnel selection

Press and hold “backup” key 3 seconds, reserve person can be switched

once. General backup duty personS are one of Captain, mate, 2nd. officer, 3rd.

officer.

6.2.4 System self-test

System self -check function can be carried on under any circumstances, press

“RESET/TEST” key, the system begins to self-test, the reset unit and the

extension alarm unit connected to the system will be flashing and the alarm rings.

Pressing the key “RESET/TEST” again, the sound will be mute and light will

not be flashing

6.3 Alarm mode setting

6.3.1 Alarm mode setting of 2nd. And 3rd. level

System default setting has three level alarm mode. According to the practical

requirements of different vessels, the level mode can be changed to two level

extension alarm mode. That is to say, in two level extension alarm mode, all

extension alarm units will appear sound and light alarm (Except for passenger ships).

Setting method: Generally based on users’ requirements, system had been setting

9
well before delivery from factory. The setting method is not open to users.

6.3.2 Delay the interval time for 2nd and 3rd alarm

System default that the Interval time between 2nd. And 3rd. level is 90 seconds. For

large ships this interval time may be extended to the maximum 3 minutes. Setting

method : Generally based on users’ requirements system had been setting well

before delivery from factory. The setting method is not open to users.

6.4 Infrared and microwave motion detection function

Bridge navigational watch alarm system can be optional to equip with infrared and

microwave motion detector. When detected OOW activities, dormant time will be

automatically reset.

6.5 Special Remind

To ensure the safety of the system settings (protection set to the dormant time and

duty mode), usually the captain keeps the key and he is the only person who lets the

system not to work.

10
6.6 Bridge navigational Watch Alarm system/Nautical Equipment Fault Alarm Operation

method (Only touch screen version has this function)

6.6.1 Layout and Description of Operation Panel

main interface

Dormant time displays

Press

“Enter”key to enter Bridge

Navigational Watch

Alarm System interface.

Alarm

state displays

Press “Enter”key to enter Nautical

Equipment Alarm System

interface.

When the system screen appears in the main interface of nautical equipment alarm failure, the

system will automatically be changed over to nautical equipment alarm system interface. When

the bridge navigational watch alarm dormant time is over by then, the system will automatically

be changed over to bridge navigational watch alarm system interface.

11
Brigational Watch Alarm System Operational Interface

Nautical Equipment Fault Alarm Operation Interface

By pressing the "BACK" key to return to the main interface

System self-test:Pressing “test” key, system sound and light alarm will give

out, recovery after 2s

Sound mute and not flashing: When the new nautical equipment appears fault,

the green lamp is changed to red lamp and flashing meanwhile the sound

alarm giving out. Pressing ACK key to mute the sound and red lamp stops

flashing.

12
6.6.2 Emergency Call

When this key is pressed for 2 seconds continuously,Ⅱ

and Ⅲ level alarm will be started directly as emergency

call function.

6.6.3 Key Switch

Pressing this key to enter the set function

Only inputting the correct password and confirmed, the dormant Time and watch mode

setting on duty can be entered.

System provides a set of passwords to the captain

After dormant time and watch mode settings finished, pressing the "Save" key, and then

pressing "Exit" key to exit

13
7、System Maintenance
 Test

Press “Reset/Test” key for 2 seconds at the same time, all digital tube will be lighting and

flashes, all connected horns will be alarming; all connected indicated light will be flashing.

 Troubleshooting

 The BNWAS countdown doesn’t work

In the general case of the countdown doesn’t work

 Check whether the system activation on duty-----the system in active the countdown

will work ,just as the key of system is “on” and the model set on hand, then the

system work

 Reset unit----each reset unit of signal shall short circle. The system can be take six

manually reset unit input, check the six terminals of I/O control on ST2, make sure the

reset unit is reliable connection, if there is no access on terminals on ST2, to be sure

the line number 1# an line number 4#(on terminals is I and p+) is short circle

 Motion reset unit----same as reset unit, check the motion reset unit line number 1#

and line number 4#(on terminals is i9 and p+)is short circle, close loop.

 Extension/reset unit doesn’t work

General problem of the extension/reset unit is alarm indicator light not work and buzzer

not sound, this is usually due to a faulty wiring,check the line number is carefully.

The alarm indicator light not work testing both ends 24v voltage input, 24V whether at

the positive and negative,this to detect the quality of the lights

 Emergency call

Only the system on duty activation can be emergency call, emergency call is all

system alarm, equivalent to three-stage alarm of system,can not aimed at a particular

room to the call.

 System alarm

Usually means the operation panel and host communication failures, sometimes

is operation panel internal line fault. Self-test will be alarm ouput and panel shows”

E1”.check carefully the line between operation panel and host connecting.

 self- test instructions

When the system self-check test, normal operation panel display system version and

14
software version, such as respectively show "the A8" "C3", self-test process take turns

show. When there is "1", "2", "3", "4 ", "5", "6 ", code, means the system access

corresponding reset eunit 1 road, the 2 road is breaks down, then to check the

corresponding reset unit connection, view each reset unit line 1 # and 4 # whether short

carcle . Operation panel display "E1" means system failure, this code can viewon

operation manual

 Motion detection fault

If there is fault of motion fault ,the motion doesn’t work, In addition to check the wiring

outside, please report to the manufacturer repair or replacement spare, motion detection

factory has tested before send out,you do not need to repair it..

If the system appears the other problems that cannot be solved, please contact us.

Tel: +86 0514-87255272-8829

021-58380732-8030

Fax: +86 021-58380958

Email: shhtop@126.com

15
8. Guidelines for BNWAS Installation
(1) Reset devices:

(i) At least one reset device should be provided near each conning position in the

wheelhouse. More reset devices may be provided to the workstations for navigation,

manoeuvering and monitoring in order for safe and effective operation, if desired.

A reset function may be initiated by motion sensors and navigational equipment such as

radar, auto-pilot, ECDIS, INS, etc.

(ii) One reset device should be provided to each bridge wing.

Where it is easy to reset a first stage alarm by a reset device located nearby in the

wheelhouse, reset devices are not required to be fitted at bridge wings.

(2) Visual indicators and First stage audible alarms

(i) A visualindicator and first stage audible alarm are to be provided in the wheelhouse.

When they are combined with a reset device, individual visual indicators and first stage

alarms are not required.

(ii) A visualindicator and first stage audible alarm are to be provided in the bridge wings.

Where a reset device is not provided in the case of l(ii) above, the following functions are

required:

- Flashing indicator in the wheelhouse should be visible from an operational position

on the bridge wing; and

- First audible alarm in the wheelhouse should be audible from an operational

position on the bridge wing

(3) Second stage audible alarms and Third stage audible alarms

(i) Second stage audible alarms should be located in the Captain's bedroom and Deck

officer cabins.

In case where there are three deck officers on board ,one deck officer for duty may be

selected from the main panel and the alarm in the Captain's bedroom may be changed to a

third stage one.

(ii) Third stage alarms should be located in the officer's Mess room,Saloon,Recreation

room and ship's office.

(4) BNWAS should be supplied by both an AC source (Main and Emergency source) and a

DC source (ship's batteries or batteries contained within the device)

16
(5) BNWAS for ships constructed on or after 1July 2011 are to connected with the following

mandatory equipment required by SOLAS.

(i) Heading Contrfol System and Track Control System

(ii) Voyage Data Recorder (VDR)

(6) With respect to small ships, BNWAS installations may be designed according to relaxed

requirements in cases where such requirements are specified by the Flag State.

(7) An emergency call facility may be provided.

9、Accessory

System connection diagram

System wiring diagram

Outline dimensional drawing

Quick guide to the operation of the BNWAS

17
Number Type Dwg. №. Page Page №.

1 Contents HTC-BNW-OUT 1 1
2 BNW Syatem Drawing HTC-BNW-SYS 1 1
3 110-113 Conecting Drawing HTC-BNW-EXL 1 2
4 Function Schematic Diagram HTC-BNW-EXL 3 3-5
5 The General Device Drawing of BNW HTC-BNW-OUT 1 6
6 Sub Device Installing Dimension and Internal Detailed Drawing HTC-BNW-OUT 7-20
14
7 Electrical Schematic Diagram HTC-BNW-EXL 7 21-27

8 Motion detection installing mode 、 effective range 3


HTC-BNW-EXL 28-30
and operation instruction
9 VDR Data format 1 31
10 Certificate 1 32

Title:
The Contents for BNW
Customer Drawing
.

HTC-BNW-SYS Title:
The Layout of BNWS
Title:
110-113 Wire Connection
张伟
To connect BNW110
main controller
unit

reserved

Auto steer
main power system failure
supply inputinput
output
reserved input (dry contact)
power supply failure
Backup power alarm output (Dry
supply input contact)

the third
stage
extending
alarm(dry 3 channels motion
contact) detection
to connect
BNW110
main
controller
unit

reserved

6 channels reset input motion


detection
Title:
Standard Ver.founction
layout of BNW
to connect
BNW110
main
controller
unit

auto steer
input

main power output


supply power supply reserved
input failure
alarm output
(dry
backup power contact)
navigation supply input system
alarm
failure
output(dry
the third output
contact) stage (dry
extending contact)
alarm(dry 8 channels navigation failure alarm
contact) reset input
to outside alarm 12 channels
buzzer 3 channels navigation failure
motion input input
Type: HTC-BNW-111 Type: HTC-BNW-111 Type: HTC-BNW-111 Type: HTC-BNW-112 Type: HTC-BNW-114-A1 Type: HTC-BNW-115
Product No.: HTC-BNW-111-A1 Product No.: HTC-BNW-111-B1-A Product No.: HTC-BNW-111-A1-A Product No.: HTC-BNW-112-A1 Product No.: HTC-BNW-114-A1 Product No.: HTC-BNW-115

Type: HTC-BNW-111 Type: HTC-BNW-111 Type: HTC-BNW-111 Type: HTC-BNW-111 Type: HTC-BNW-112 Type: HTC-BNW-114-B1
Product No.: HTC-BNW-111-B1 Product No.: HTC-BNW-111-B1-F Product No.: HTC-BNW-111-A1-F Product No.: HTC-BNW-111-B2 Product No.: HTC-BNW-112-B1 Product No.: HTC-BNW-114-B1

Title:
The General Drawing of
BNW Parts 张伟
Outline Dmensions(W×H×D) 400× 360× 185
Installation Dmensions with Accessory 4-Φ6.5:380×320
Installation Dmensions Without Accessory 4-Φ6.5:380×280
Case Material ABS(RAL7035)
Shielding Shell Material
Weight 10Kg
Protection Grade IP22

Power Supply
Current Consumption appr. 1500mA
Compass Safety Distance >50cm

Two kinds of installing mode for


option, with accessory and
without accessory

TYPE Title:
Main control+ unit
TYPE:HTC-BNW-113-B1 张伟 潘明艳 尹顺利 董良斌
2011-8-22 2012-4-10 2012-4-10 2012-4-10 7/32
Dmensions(W×H×D) 100× 210× 55
Installation Dmensions(Fixed Holes) 4-Φ4.2:68×190
+1 +1
Panel Cut-Out 80 × 160
Case Material ABS(RAL7035)
Weight 0.35Kg
Protection Grade IP22

Power Supply DC24V


Current Consumption appr. 20mA

(hole dimension)
1 2 3 4

TYPE Title:
Rest Unit
TYPE:HTC-BNW-111-A1 张伟 潘明艳 尹顺利 董良斌
2011-8-22 2012-4-10 2012-4-10 2012-4-10
Dmensions(W×H×D) 80× 160× 55
Installation Dmensions(Fixed Holes) 4-Φ4.2:68×148
Case Material ABS(RAL7035)
Weight 0.35Kg
Protection Grade IP22

Power Supply DC24V


Current Consumption appr. 20mA

1 2 3 4

TYPE Title:
Reset Unit
TYPE:HTC-BNW-111-B1 张伟 潘明艳 尹顺利 董良斌
2011-8-22 2012-4-10 2012-4-10 2012-4-10
Outline Dmensions(W×H×D) 80× 184× 87
Installation Dmensions(Fixed Holes) 4-Φ4.2:68×172
Case Material ABS(RAL7035)
Weight 0.35Kg
Protection Grade IP56

Power Supply DC24V


Working Current Consumption appr. 20mA

1 2 3 4

Title:
Reset Unit
TYPE:HTC-BNW-111-B2 张伟 潘明艳 尹顺利 董良斌
2011-8-22 2012-4-10 2012-4-10 2012-4-10
(Φ4.2Hole Dimension)
Outline Dmensions(W×H×D) 82.5× 103.5× 76
Installation Dmensions(Fixed Holes) 4-Φ4.2:70×50
Case Material ABS(RAL7035)
Weight 0.2Kg
Protection Grade IP22

(Φ4.2hole dimension)
U:600V Ith 10A NC

NC
1 2

TYPE Title:
Reset Unit
张伟 潘明艳 尹顺利 董良斌
TYPE:BNW-111-B1-A 2011-8-18 2012-4-10 2012-4-10 2012-4-10
(Φ4.2 hole dimension) Outline Dmensions(W×H×D) 82.5× 103.5× 68.5
Installation Dmensions(Fixed Holes) 4-Φ4.2:70×50
Case Material ABS(RAL7035)
Weight 0.2Kg
Protection Grade IP22

(Φ4.2 hole dimension)


Power Supply DC24V
Working Current Consumption appr. 20mA
Output sound dB 85dB/10cm

1 2

TYPE Title:
Reset rewinding Buzzer
TYPE:HTC-BNW-111-B1-F 张伟 潘明艳 尹顺利 董良斌
2011-8-22 2012-4-10 2012-4-10 2012-4-10
Outline Dmensions(W×H×D) 40× 40× 53
Installation Dmensions(Fixed Holes) Φ22.5
Weight 0.05Kg
Protection Grade IP22

U:600V Ith 10A NC

installing hole dimension

1 2
NC

TYPE Title:
Reset Button
TYPE:HTC-BNW-111-A1-F 张伟 潘明艳 尹顺利 董良斌
2011-8-22 2012-4-10 2012-4-10 2012-4-10
Outline Dimensions(W×H×D) 24× 24× 50
Installation Dimensions(Fixed Holes) Φ22.5
Weight 0.05Kg
Protection Grade IP22

Power Supply DC24V


Working Current Consumption appr. 20mA
Output sound dB 85dB/10cm

installing hole dimension

1 2

TYPE Title:
Buzzer
TYPE:HTC-BNW-111-A1-F 张伟 潘明艳 尹顺利 董良斌
2011-8-22 2012-4-10 2012-4-10 2012-4-10
Outline Dimensions(W×H×D) 100× 195× 75
Installation Dimensions(Fixed Holes) 4-Φ4.2:68×155
+0.5 +0.5
installing dimension 81 × 141
Case Material ABS(RAL7035)
Weight 0.35Kg
Protection Grade IP22

Power Supply DC24V


Working Current Consumption appr. 50mA
Output Sound dB 75dB-85dB/1m

Tone tuning

ST1 SW1
1 LAP
2
3
4

TYPE Title:
Extending Alarm Unit
张伟 潘明艳 尹顺利 董良斌
TYPE:HTC-BNW-112-A1 2011-8-22 2012-4-10 2012-4-10 2012-4-10
Outline Dimensions(W×H×D) 81× 149× 75
Installation Dimensions (Fixed Holes) 4-Φ4.2:60×134
Case Material ABS(RAL7035)
Weight 0.35Kg
Protection Grade IP22

Power Supply DC24V


Working Current Consumption appr. 50mA
Output Sound dB 75dB-85dB/1m

Tone tuning
ST1
1
SW1
LAP
2
3
4

TYPE Title:
Extending Alarm Unit
TYPE:HTC-BNW-112-B1 张伟 潘明艳 尹顺利 董良斌
2011-8-22 2012-4-10 2012-4-10 2012-4-10
Outline Dmensions(W×H×D) 81× 195× 75
Flush mounted Installation Dimensions(Fixed Holes) 4-Φ6:152×76
+1 +1
Flush mounted Installation Dimensions(Cut out) 136 × 136
Wall mounted Installation Dimensions(Fixed Holes) 2-Φ6:L=87
Case Masterial ABS(RAL7035)
(Φ6 Flush mounted hole) Weight 1Kg
Protection Grade IP22

(Flush mounted cut out)

Note:Any installation can be selected from Flush mounted mode and Wall mou

Power Supply DC24V


working Current Consumption appr. 100mA

(Flush mounted cut out)


Flush mounted hole)
Protection test

(Φ6
pattern

15m

(Φ6Wall mounted hole)

Any installation mode of two kinds installation mode can be selected

installing height visual areas


2.4m 8m
1 2 3 4

2.7m 9.6m
Wiring terminals
3.3m 13.5m
TYPE Title:
Motion detection Unit
张伟 潘明艳 尹顺利 董良斌
TYPE:HHTC-BNW-114-A1 2011-8-22 2012-4-10 2012-4-10 2012-4-10
Outline Dimensions(W×H×D) 125× 75× 44
Installation Dimensions(Fixed Holes) 2-Φ5:L=45
Case Material ABS(RAL7035)
Weight 0.2Kg
Protection Grade IP22

Power Supply DC24V


Working Current Consumption appr. 100mA

Detecting visual area pattern(only


for reference)

12

installing hole dimension

1 2 3 4

Wiring terminals

TYPE Title:
Motion Detecting Unit
张伟 潘明艳 尹顺利 董良斌
TYPE:HTC-BNW-114-B1 2011-8-22 2012-4-10 2012-4-10 2012-4-10
Outline Dimensions(W×H×D) 160× 260× 94 Input Power Supply AC220V DC24V
Installation Dimensions(Fixed Holes) 4-Φ8.5:140×210 output power capacity appr. 100VA
Case Material AL(RAL7035) Compass Safe Distance >50cm
Weight 5.5Kg
Protection Grade IP22

TYPE Titles:
Power Supply Unit
TYPE:HTC-BNW-115 张伟 潘明艳 尹顺利 董良斌
2011-8-22 2012-4-10 2012-4-10 2012-4-10
Cable Length 0.5m Terminals Definition Shown in figure
Cable Type 7× 0.5mm (7 cores shielding cable)

TYPE Title:
Connecting Cable WS02-2
张伟 潘明艳 尹顺利 董良斌
2011-8-22 2012-4-10 2012-4-10 2012-4-10
control box

navigation
failure alarm

备用 备用

comprehensive
alarm board

S radar electronic spare spare spare


radar chart

outside alarm input

Title:
wiring diagram for
navigation failure alarm
control box

channels manual reset


input

port starboard BCC left BCC right Chart radio spare spare
area space

Title:
wiring diagram of manual
reset unit
control box

10 channels extending alarm output

captain chief second third meeting spare spare spare spare


marine
room alarm office officer officer room
dining
room room room room alarm
alarm alarm alarm alarm

captain bed room


alarm

wiring diagram of extending
alarm unit
Controlboard

Motion Detecting input

Revision

Sheet of

main 24 emergency 24 Power supply


failure alarm

comprehensive
alarm board

main power supply

Power supply box emergency power supply

Title:
wiring diagram for main
and backup power supply
Mode 2

X-Brand S-Brand
Radar Radar

Bridge
Console
Nav Lookout
Console Console
IP56 IP56

Port Bridge Wing


Starboard Bridge Wing
Steering Stand
GMDSS Console

Radio space
Chart Space

BNW110 Main Controller unit


BNW111 Reset Unit
BNW114 Motion detection Unit

HTC-BNW-OUT
Title:
The General Layout of
BNWAS( V2)
Mode 3

X-Brand Radar S-Brand Radar

Bridge
Console
Nav lookout
Console Console
IP56 IP56

Port Bridge Wing Starboard Bridge Wing


Steering Stand
Radio Space

Chart Space

BNW110 Main Controller unit


BNW111 Reset Unit
BNW114 Motion detection Unit

HTC-BNW-OUT
Title:
The General Layout of
BNWAS
Mode 4

X-Brand S-Brand
Radar Radar

Bridge
Nav. Console
Lookout
Console Console
IP56 IP56

Port Bridge Wing Steering Stand


Starboard Bridge Wing
Radio space

Radio Table
Chart Table

BNW110 Main Controller unit


BNW111 Reset Unit
BNW114 Motion detection Unit

HTC-BNW-OUT
Title:
The General Layout of
BNWAS ( V2)
HTC-BNW-SERIES BNWAS VDR Signal Communication Agreement

VDR Signal output Communication Agreement(NMEA-0183)


Communication Mode RS485
Baud Rate 9600
Parity Check Non
Data Bits 8
Send Mode Timed loop send(2s)

Data Format
Data Content Description Condition Describe
$ Start Code
B
N
W
, Delimiter
1 Key Switch 0:Off、1:ON
, Delimiter
0 Setting Time Alarm Setting Time(min)
8 (08=8 minutes)
, Delimiter
1 Operation Mode 0: Manual Off、1: Manual On、2: Auto.
, Delimiter
Selection Of Extension 0:Captain、1:Chief officer、2:2nd. officer、3:3rd.
3
Alarm officer
, Delimiter
1 Actived State 0 :stop、1: Active
, Delimiter
1 Reset Actions 0:No Input、1:Input
, Delimiter
1 Emergency Call 0:No Input、1:Input
, Delimiter
1 System Fault 0: Normal、1: Alarm Output
, Delimiter
0: No Alarm、1: Visual warning、2: First Stage
Working Mode Of
0 Alarm、3: Second Stage Alarm、4: Third Stage
Extension Alarm
Alarm
, Delimiter
Main Power Supply
2 0: Normal、1: Alarm Output
Failure
, Delimiter
Emergency Power
0 0: Normal、1: Alarm Output
Failure
, Separator
* End code
H
H
0x0D<CR> enter
0x0A<LF>
Data Exa. $BNW,1,08,1,3,0,0,0,0,0,0,1, * 51

Hapcon (Yangzhou)Automation Technology Co.,Ltd


Quick Operating Instructions of BNW110 Controller

Display Panel

Bridge Navigational Watch Alarm System

Alarm Ext. Dormant Time Watch Mode


Manual off
PRE-alarm

1st.Stage Alarm
+ Manual on
Mode

Auto
2nd.Stage Alarm

3nd.Stage Alarm
Min.
- 1
3
2
4
Buck-up
Parameter setting area

Working Status Display 1:Captain


3:2nd officer
2:Chief officer
4:3rd officer

Watch Active

Main Pwr Fault Reset


ON
Emerg Pwr Fault EMERG Reset System key switch
CALL Test
System Fault OFF

Dimmer Key
Functional Operation Buttons

Control Panel Layout of BNW110


Status Description: :

LED constant lighting


LED constant flicker
LED constant flicker

LED constant off

LED constant normal


Main power alarm Emergency power alarm

Watch Active Watch Active

Main Pwr Fault Main Pwr Fault

Emerg Pwr Fault Emerg Pwr Fault

System Fault System Fault

The main power supply is not input, the main power failure light is The emergency power supply is not input, the emergency power failure
flashing and the buzzer sound; light is flashing and the buzzer sound;

Reset Reset
Test Test
Press to halt noise & light alarm
Press to halt noise & light alarm

Watch Active
Watch Active
Main Pwr Fault
Main Pwr Fault
Emerg Pwr Fault
Emerg Pwr Fault
System Fault
System Fault

Press this button to stop the noise alarm and indicator LED light off, Press this button to stop the noise alarm and indicator LED light off, the
buzzer silencer. emergency power alarm indicat LED flicker disappear, buzzer silencer.
Backup duty select operation
Press Back-up button to select the Backup duty, reserve select 1 to 4 corresponds to an extension of 1 to 4 alarm output
port; (in any state can select to Backup duty)

Buck-up Buck-up

Watch Mode Watch Mode

Manual off Manual off


Mode Mode
Manual on Manual on
Auto Auto

1 2 Buck-up 1 2 Buck-up
3 4 3 4

1:Captain 2:Chief officer 1:Captain 2:Chief officer


3:2nd officer 4:3rd officer 3:2nd officer 4:3rd officer

Buck-up Buck-up

Watch Mode Watch Mode

Manual off Manual off


Mode
Manual on Manual on Mode

Auto Auto

1 2 Buck-up 1 2 Buck-up
3 4 3 4

1:Captain 2:Chief officer 1:Captain 2:Chief officer


3:2nd officer 4:3rd officer 3:2nd officer 4:3rd officer
Backup duty select operation Activation into work description
Press Back-up
button to select the
Backup duty,
reserve select 1 to 4
Watch Mode
corresponds to an
Watch Active Manual off
extension of 1 to 4 Mode
Buck-up alarm output port; Manual on
Main Pwr Fault
(in any state can Auto ON
select to Backup Emerg Pwr Fault
duty) 1 2 Buck-up
OFF
System Fault
3 4

1:Captain 2:Chief officer

Watch Mode 3:2nd officer 4:3rd officer


Key switch
Manual off
Mode
Manual on Key switch in the OFF, the alarm system does not work on duty, on
Auto duty mode does not show.
1 2 Buck-up
3 4

1:Captain 2:Chief officer


3:2nd officer 4:3rd officer

Watch Mode
Watch Active Manual off
Mode
Buck-up Main Pwr Fault Manual on
Auto ON
Emerg Pwr Fault
1 2 Buck-up
System Fault OFF
3 4

Watch Mode 1:Captain 2:Chief officer

Manual off
3:2nd officer 4:3rd officer Key switch
Mode
Manual on
Auto
Key switch in the ON, the watch alarm system to work according to
1 2 Buck-up
shift patterns Status: In manual mode off duty, the duty alarm
3 4 system does not work;

1:Captain 2:Chief officer


3:2nd officer 4:3rd officer

Buck-up Watch Mode


Watch Active Manual off
Mode
Main Pwr Fault Manual on
Auto ON
Emerg Pwr Fault
1 2 Buck-up
Watch Mode System Fault OFF
3 4
Manual off
Mode
Manual on 1:Captain 2:Chief officer

Auto 3:2nd officer 4:3rd officer


Key switch
1 2 Buck-up
3 4
In manual shift mode to open, the duty to immediately enter the work
1:Captain 2:Chief officer state of alarm system, activate the indicator light duty;
3:2nd officer 4:3rd officer

Buck-up
Watch Mode
Watch Active Manual off
Mode
Manual on
Main Pwr Fault
Auto ON
Emerg Pwr Fault
1 2 Buck-up
Watch Mode System Fault OFF
3 4
Manual off
Mode
Manual on 1:Captain 2:Chief officer
Auto 3:2nd officer 4:3rd officer Key switch
1 2 Buck-up
3 4

1:Captain 2:Chief officer


4:3rd officer
3:2nd officer Watch in the automatic mode, the auto-rudder signal is not on duty
when the alarm system does not work, activate the indicator does not
light duty; when the automatic pilot on duty when the alarm system
signal input to start work immediately while on duty activated lights.
Emergency call operation
Tips: In the active work, the emergency call function to start.

Alarm Ext. Dormant Time

+
PRE-alarm Watch Active

1st.Stage Alarm Main Pwr Fault

2nd.Stage Alarm Emerg Pwr Fault

3nd.Stage Alarm System Fault


Min.
-

Alarm system is activated duty work, the emergency call function to start.

EMERG
CALL
Press more than 2 seconds

Alarm Ext. Dormant Time


PRE-alarm

1st.Stage Alarm
Watch Active

Main Pwr Fault


+
2nd.Stage Alarm Emerg Pwr Fault

3nd.Stage Alarm System Fault


Min.
-

Emergency call function is activated, the same start 3rd. alarm;

Reset

Alarm Ext. Dormant Time

PRE-alarm

1st.Stage Alarm
Watch Active

Main Pwr Fault


+
2nd.Stage Alarm Emerg Pwr Fault

3nd.Stage Alarm System Fault


Min. -

State in an emergency call, press the reset button or other input reset signal
back to the normal state;
Reset unit detects Main power alarm
Note: This feature is only comes BNW111 detection system reset unit or part of the
mobile detection unit for access to the situation, the other unit does not detect external
reset input, and do not take on this port; if BNW111 unit does not need access, we
should enter the port Line 1 # and 4 # line shorted;

When the
external reset Dormant Time
unit open or Watch Active

+
Watch Active
missed, the Main Pwr Fault
system fault Main Pwr Fault
LED flashes Emerg Pwr Fault
and the Emerg Pwr Fault
location of
digital System Fault
Min.
- System Fault

window
displays the
port number
and flashing
failure; when The main power supply is not input, the main power
there are failure light is flashing and the buzzer sound;
multiple faults
exist, the
alternate port

Reset Reset
Test Test
Press to halt noise & light alarm Press to halt noise & light alarm

After the
muffler system
failure Dormant Time Watch Active
indicator light
+
Watch Active
given plain, Main Pwr Fault
digital display
Main Pwr Fault
interface Emerg Pwr Fault
window back Emerg Pwr Fault
to sleep time;
muffler fixed System Fault
Min.
- System Fault

light after the


port number if
you want to
observe the
fault, you can Press this button to stop the noise alarm and
press and indicator LED light off, buzzer silencer.
self-test button; ;

Reset more than 2


New error display or press Test
seconds

After self-test
again or a new Watch Active
fault occurs, the Dormant Time
system fault Main Pwr Fault
LED flashes and
digital window
Watch Active

Main Pwr Fault


+ Emerg Pwr Fault

displays the System Fault


location of the Emerg Pwr Fault
failed port and
flashes; when System Fault
Min. -
there are multiple
faults exist, in
turn displays the
fault port.

Reset
Test
Troubleshooting Press to halt noise & light alarm

Dormant Time
Watch Active

+
Watch Active
Main Pwr Fault
Main Pwr Fault
Troubleshootin Emerg Pwr Fault
g off Emerg Pwr Fault
automatically
after system System Fault
Min. - System Fault

fault LED
digital display
interface
window back Press this button to stop the noise alarm and
to sleep time. indicator LED light off, buzzer silencer.
Communication and alarm system description

Dormant Time

Watch Active

Main Pwr Fault


+
Emerg Pwr Fault

System Fault
Min.
-

Internal communication system failure, system failure indicator light


flashes, while the digital window display fault No.: E1 and flash;
buzzer alarmed.

Reset
Press Test to halt noise & light alarm

Dormant Time

Watch Active

Main Pwr Fault


+
Emerg Pwr Fault

System Fault
Min.
- After the muffler system
failure indicator light given
plain, digital window
display failure to retain No.:
E1 and plain
communication failure does
not rule out, has been
shown in this interface;

Dormant Time Dormant Time

Watch Active

Main Pwr Fault


+ Watch Active

Main Pwr Fault


+
Emerg Pwr Fault
Emerg Pwr Fault

System Fault
Min. - 或
System Fault
Min. -

Internal communication system failure, system After the muffler system failure indicator
failure indicator light flashes, while the digital light given plain, digital window display
window display fault No.: E1 and flashes; failure to retain No.: E1 and plain;
Troubleshooting communication failure does not rule out, has
been shown in this interface;

Dormant Time

+
Watch Active

Main Pwr Fault

Emerg Pwr Fault

System Fault
Min.
-

Troubleshooting off automatically after system fault LED


digital display interface window back to sleep time.
Dorment time and operation mode

Dormant Time Watch Mode

+ Manual off
Manual on
Mode

Auto

Min. - 1
3
2
4
Buck-up

1:Captain 2:Chief officer


3:2nd officer 4:3rd officer

Reset
ON
EMERG Reset
CALL Test
OFF
The key switch from OFF to ON
after the rotation, 30s can be
within + or - keys to adjust duty
sleep time. (Sleep time in between
3 to 12 minutes) Turn this switch from OFF to ON The key switch from OFF to ON
after the rotation, 30s carried out
ON within the duty to press the mode
button mode selection operation.
OFF

Dormant Time
Dormant Time Watch Mode

+ +
Manual off

Manual on
Mode Mode

Auto

Min. - Min.
- 1 2 Buck-up Manual off
3 4 Manual on
Auto
1:Captain 2:Chief officer
3:2nd officer 4:3rd officer

+ Mode

Reset
ON
Dormant Time EMERG Reset
CALL Test Manual off
+ OFF Manual on
Auto

Min.
-
Mode

- Reset Manual off


Manual on
Dormant time and watch mode Auto

Dormant Time

+ After editing, you can press the reset


button store settings and exit setup. (If
you do not press the reset button, 30s
Min. - Dormant Time Watch Mode
the system will automatically store the
settings and exit the set)

+ Manual off
Manual on
Mode

Auto

Min.
- 1
3
2
4
Buck-up

1:Captain 2:Chief officer


3:2nd officer 4:3rd officer

Reset
ON
EMERG Reset
CALL Test
OFF
Status of extension alarm Emergency call operation
Tips: In the active work, the emergency call feature can be activated.

Alarm Ext. Dormant Time


Alarm Ext. Dormant Time
Pre-alarm
+
+
Pre-alarm Watch Active
1st.Stage Alarm
1st.Stage Alarm Main Pwr Fault
2nd.Stage Alarm
Min. - 2nd.Stage Alarm Emerg Pwr Fault
3nd.Stage Alarm
3nd.Stage Alarm System Fault
Min. -
Pre-alarm status
Alarm system is activated on duty work, the emergency call function to
start;
Delay 15s

EMERG
Press CALL more than 2 seconds
Alarm Ext. Dormant Time

Pre-alarm

1st.Stage Alarm
+
2nd.Stage Alarm

3nd.Stage Alarm
Min. - Alarm Ext. Dormant Time

Pre-alarm

1st.Stage Alarm
Watch Active

Main Pwr Fault


+
1st. stage alarm status
2nd.Stage Alarm Emerg Pwr Fault

3nd.Stage Alarm System Fault


Min. -
Delay 15s

Emergency call function is activated, the same start three alarm;


Alarm Ext. Dormant Time

Pre-alarm

1st.Stage Alarm
+
2nd.Stage Alarm Press to reset

3nd.Stage Alarm
Min. - Reset

2nd. stage alarm status


Alarm Ext. Dormant Time

Delay 90s
+
Pre-alarm Watch Active

1st.Stage Alarm Main Pwr Fault

2nd.Stage Alarm Emerg Pwr Fault

Alarm Ext. Dormant Time 3nd.Stage Alarm System Fault


Min. -
+
Pre-alarm

1st.Stage Alarm
State in an emergency call, press the reset button or other input reset
signal back to the normal state;
2nd.Stage Alarm

3nd.Stage Alarm
Min. -
3rd. stage alarm status

Press or other reset signal inputs


Reset

Alarm Ext. Dormant Time

Pre-alarm

1st.Stage Alarm
+
2nd.Stage Alarm

3nd.Stage Alarm
Min. -
A reset signal input back to normal working condition.
System self-test operation
Reset
System power on press Test more than 2 seconds to stert self-test

Alarm Ext. Dormant Time Watch Mode

Pre-alarm

1st.Stage Alarm
+ Manual off
Manual on
Mode Watch Active

Main Pwr Fault


Auto
2nd.Stage Alarm Emerg Pwr Fault

3nd.Stage Alarm
Min. - 1
3
2
4
Buck-up
System Fault

All display dots lights

Delay 1.5s

Alarm Ext. Dormant Time Watch Mode

+
Pre-alarm Manual off Watch Active
Mode
Manual on
1st.Stage Alarm Main Pwr Fault
Auto

2nd.Stage Alarm Emerg Pwr Fault

3nd.Stage Alarm
Min. - 1
3
2
4
Buck-up
System Fault

All display dots off

Delay 1.5s

Alarm Ext. Dormant Time Watch Mode


Pre-alarm Manual off

+
Watch Active
Mode
Manual on
1st.Stage Alarm Auto Main Pwr Fault

2nd.Stage Alarm Emerg Pwr Fault

3nd.Stage Alarm
Min.
- 1
3
2
4
Buck-up
System Fault

Digital window displays BNW113 I / O control unit version number: (A1)

Delay 1.5s

Alarm Ext. Dormant Time Watch Mode

+
Pre-alarm Manual off Watch Active
Mode
Manual on
1st.Stage Alarm Main Pwr Fault
Auto

2nd.Stage Alarm Emerg Pwr Fault

3nd.Stage Alarm
Min.
- 1
3
2
4
Buck-up
System Fault

Digital window displays the main control unit BNW110 program version number: (A2)

Exit self-test status