You are on page 1of 4

ZUBAIR

Machine/Model NO: 42044SP2/MILNOR/380V Inspection by:


PARVIEZ
4-
SERIAL NO: 10257891 Date and time: APRIL-
2023
Customer Name: Royal Commission, Yambu Signature:
Location: Royal Commission, Yambu

No Inspection/Problems Parts. No summary

•COMPONENT NUMBER(MVINV)
The machine is currently not
running. The VFD already is taken •FUNCTION
out from inside the machine and its THIS COMPONENT (INVERTER-SINGLE
MOTOR DRIVE 4244 HIGH VOLT)
wires are additionally disunited.
The maintenance management there •WHERE TO FIND
01 verbalizes that its inverter is THIS COMPONENT(W6W5SSVP)
damaged and needs to be replaced.
•MILNOR P/N(09MWA03996)
📔NOTE.
Other faults in the machine will be •DESCRIPTION (INVERTER 39AMPS 480V F7)
checked after installing the inverter.
•LOCATION (HIGH VOLT BX)

SERIAL NO: 10250410 Date and time: 4-APRIL-2023

No Inspection/Problems Needs summary


Brake system of the machine is not
working. Oil is leaking from the Need brake oil &
01 brake calliper. review the parts
brake unit and oil are required to information below.
solve this problem.
SERIAL NO: 10254691 Date and time: 4-APRIL-2023

No Inspection/Problems Needs summary


Need Double coil relay & its
Machine door signal is not been socket. check the relay part
transmitted from the clean side to number from below information
01 soil side. Clean side transfer relay is 📔NOTE.
not working properly.it is worn and Relay socket part
loose in its socket. number is not included please
added in your request

Company Name; __________________________________ Submitted By: ____________________

Site Address: _______________________________________________________________________

Notes & Comments: _________________________________________________________________


_______________________________________________________________