You are on page 1of 6

Industry & Facilities Division Page:1 /6

□ Interim
√ Final

INSPECTION REPORT N° BV/MCL/LOAD TEST- 26 NOVEMBER-2023


BV Job nr: BAN.D.3084A6.023.779/03
PROJECT: Thorough Inspection of Mobile Crane Ref: BAN.D.3084A6.023.779/03
BV Client: MAZADA Consortium Limited P/o nr: N/A
Manufacturer: TADANO Limited P/o nr: N/A
Inspection requested by: Mr. Md. Nazrul Islam, Manager- Heavy Lifting & Haulage

SUPPLY / SUBJECT OF INSPECTION ITEM / TAG Nr QTY


1. Manufacturer: TADANO Limited
2. EPEC No : GR500M-3-00113
3. Serial No : 582219
Thorough Inspection of Mobile Crane
4. Capacity : 50 Ton
5. DATE : 2014
01
6. Wire Dia : Main Hook 20mm, Aux Hook 20 mm
7. Hook Cap; : 50 Ton Main Hook & 04 Ton Aux Hook
8. Reg Number : In the Process.

DOCUMENTS OF REFERENCE : See continuation sheet for additional documents: Yes No


Title Reference n° Rev. Approved by Expire Date
1. Load Chart Found Manufacturer
2. Wire rope certificate Found
3. Previous Inspection Report Not Found
4. BRTA Paper In Processing

INSPECTIONS : Results of inspection : Satisfactory Unsatisfactory


Inspection place & Date or Period: Non Conformities Reports (NCR):
NCR’s issued during reported period : 0
Mazada Consortium Limited
Madanpur Yard, Narayanganj
26 November-2023 List of outstanding NCR’s : 0

Stage of inspection :
Before manufacturing Main Conclusions & Remarks:
During manufacturing
Final - See recommendation’s and perform corrective action
Packing accordingly.
Type of inspection:
Pre-inspection meeting
Document and QC record review
Visual examination, checks Next visit scheduled:
Witnessing tests
Manufacturing progress status Before 26 November-2024
Vendor assessment
Final inspection
Packing
(for details see continuation sheet)
Stamping :
No

INSP 002 En Copyright Bureau Veritas 04/2011


GM SI 101
Industry & Facilities Division Page:2 /6

□ Interim
√ Final

INSPECTION REPORT N° BV/MCL/LOAD TEST- 26 NOVEMBER-2023


BV Job nr: BAN.D.3084A6.023.779/03

Description of the inspections carried out:

Introduction:
MAZADA Consortium Limited has signed Third Party Inspection contract with Bureau Veritas
(Bangladesh) Private limited, Bangladesh. BV Bangladesh conducted the inspection on 26/11/2023 at
Mazada equipment yard, Madanpur, Narayanganj and the attendee was as under:

Md. Ariful Islam, Industrial Surveyor, Bureau Veritas (Bangladesh) Private limited.

Details of Inspection activities carried out with respect to scope of work:


• Thorough Examination
• Verification of related documents.
.
Findings:

DESCRIPITION CONDITION / REMARKS / PERFORMANCE TESTS


GENERAL DESCRIPTION OF THE
0
EQUIPMENT
• Manufacturer: TADANO Limited
• EPEC No : GR500M-3-00113
• Serial No : 582219
• Capacity : 50 Ton
0.0 Description
• DATE : 2014
• Wire Dia : Main Hook 20mm, Aux Hook 20 mm
• Hook Cap; : 50 Ton Main Hook & 04 Ton Aux Hook
• Reg Number : In the Process.
1 FIXED ACCESS
1.1 Access to the cab, to the cockpit Found in acceptable condition
1.2 Other access for maintenance and testing Found in acceptable condition
2 FRAMING
2.1 Counterweight (nature, fixing, tie) Found in acceptable condition
2.2 Jib, boom, boom extension, turret Found in acceptable condition
2.3 Structure, bridge, guy Found in acceptable condition
3 CHASSIS
3.1 Position holding outriggers road extensions Found in acceptable condition
3.2 Running gear (caterpillars, pneumatic...) Found in acceptable condition
3.3 Stabilizers Found in acceptable condition
3.4 Sleepers, rails, sub-frame Not Applicable
4 SOURCE OF ENERGY
4.1 Power supply limitation Found in acceptable condition
4.2 Equipment, wiring system, coiling units Found in acceptable condition
5 CAB - DRIVER'S CAB
Found in acceptable condition
5.1 Air heating/Cooling

INSP 002 En Copyright Bureau Veritas 04/2011


GM SI 101
Industry & Facilities Division Page:3 /6

□ Interim
√ Final

INSPECTION REPORT N° BV/MCL/LOAD TEST- 26 NOVEMBER-2023


BV Job nr: BAN.D.3084A6.023.779/03

5.2 Condition, fastening devices, foot rack, Found in acceptable condition

5.3 Protection against falls from height Found in acceptable condition


Found in acceptable condition
Working visibility (glass transparency,
5.4
windshield wipers, rear-view mirror)

5.5 Lighting Found in acceptable condition

5.6 Seat Found in acceptable condition


OPERATING AND MATERIALS HANDLING
6
DEVICES
6.1 Start / Stop Found in acceptable condition
6.2 Lock-out of use (tagging out) Not Found
6.3 Other emergency stops Found in acceptable condition
6.4 Indicators, signalling and warning devices Found in acceptable condition
6.5 Identification of control devices In English.
6.6 Automatic return to neutral point Working properly.
6.7 Warning signals Found in acceptable condition
Protecting devices against unwilling or non- Found in acceptable condition
6.8
voluntary operations
MAIN RUNNERS, GUYS, DRUMS,
7
PULLEYS, FASTENING DEVICES
7.1 Fasteners, clips, straps, clamps Found in acceptable condition
7.2 Fastening devices Found in acceptable condition
Main runners and lines, guys (Cables or Found in acceptable condition
7.3
chains)
Drums, pulleys, rope blocks, drive pinions, Found in acceptable condition
7.4
windlasses
8 MECANISMS
8.1 Speed-limiting device (no runaway) Found in acceptable condition
8.2 Locking device when out of order Found in acceptable condition
8.3 Hoist brake Found in acceptable condition
8.4 Power and gear transmission system Found in acceptable condition
8.5 Drive components, couplings, connections Found in acceptable condition
Protection of the mobile parts of the power Found in acceptable condition
8.6
transmission
8.7 Parking brake, travel-brake Found in acceptable condition
8.8 Slewing brake Found in acceptable condition
9 SAFETY DEVICES Found in acceptable condition
9.1 Limit stops relating to lifting motions Found in acceptable condition
Any other limit or travel stops - Limit switch Found in acceptable condition
9.2
actuator
9.3 Load limiter Found in acceptable condition
Locking device of mobile units during driving Functional
9.4
process on track/road

INSP 002 En Copyright Bureau Veritas 04/2011


GM SI 101
Industry & Facilities Division Page:4 /6

□ Interim
√ Final

INSPECTION REPORT N° BV/MCL/LOAD TEST- 26 NOVEMBER-2023


BV Job nr: BAN.D.3084A6.023.779/03
Not found
9.5 Anemometer
Inclination limiter - Indicator/sensor of the Found in acceptable condition
9.6
inclination
10 FUNCTIONAL LOAD TESTS
10.1 Static Functional load test Accepted
10.2 Dynamic Functional load test Accepted
11 OTHERS
11.1 Capacity display Found in acceptable condition
11.2 Safety and use instructions Found in acceptable condition

Load Calibration:

Description of Test Actual Displayed Test


Boom SWL Variance
Main Hook block on 6 Parts of Line at the time of Radius Radius Load
Length (Ton) % Radius
Inspection. (Outriggers fully extended) (metre) (metre) (Ton)
(metre)
101% SWL Test at Intermediate Boom Length 28.5 10.0 10..0 10.7 10.6 0.0
with main hook.

Actions Recommended:
1. Spark arrestor need to be attached.
2. Proper maintenance should be followed as per manufacturer schedule and record.
3. Based on thorough visual examination, functional and proof load test the equipment described
above was found satisfactory at the time of inspection.
The inspection results are valid at time and place of inspection. The above inspection has been carried out according to Bureau
Veritas general conditions of service, the issuance of this inspection report does not release the contractual parties from their
own responsibilities and the fulfilment of their obligations.

ANNEXES Yes (Total number of pages) No

Inspected by: Checked by: Authorized by:


Md. Ariful Islam Name: Rezaul Hasan Name: Wahid Murad

Signature: Signature: Signature:


Date of issue: 26/11/2023
Inspection Centre BV Dhaka
Distribution: MCL BV Bangladesh.

INSP 002 En Copyright Bureau Veritas 04/2011


GM SI 101
Industry & Facilities Division Page:5 /6

□ Interim
√ Final

INSPECTION REPORT N° BV/MCL/LOAD TEST- 26 NOVEMBER-2023


BV Job nr: BAN.D.3084A6.023.779/03
Photographs

Name Plate Mobile Crane

Boom Hooks

Capacity Display (Under Load) Test Load

INSP 002 En Copyright Bureau Veritas 04/2011


GM SI 101
Industry & Facilities Division Page:6 /6

□ Interim
√ Final

INSPECTION REPORT N° BV/MCL/LOAD TEST- 26 NOVEMBER-2023


BV Job nr: BAN.D.3084A6.023.779/03

Wire Rope Wire Rope

Over Load Signal Hydraulic Line

Load Chart Calibration Without Load

INSP 002 En Copyright Bureau Veritas 04/2011