Simphony FreedomPay Marriott Implementation – Preinstall and


Cutover

INDEX
INDEX ............................................................................................................................................................................. 1
NOTES ............................................................................................................................................................................. 3
CHANGELOG ................................................................................................................................................................. 3
FLOWCHART ................................................................................................................................................................. 4
General Information ................................................................................................................................................. 5
Scope of Work ............................................................................................................................................................. 5
Simphony Configuration: ....................................................................................................................................... 5
OPI (Oracle Payment Interface) ........................................................................................................................... 5
Offline PMS Interface ............................................................................................................................................. 5
FreedomPay ............................................................................................................................................................. 5
PREREQUISITES ......................................................................................................................................................... 6
Simphony EMC Configuration and Pre-Installation ....................................................................................... 8
CAL Packages (Only for using Lane devices) ............................................................................................... 8
Payment Drivers (Only for using Lane devices)........................................................................................ 10
Payment Module (Only for Lane devices) ................................................................................................... 13
Tender Media (for both Lane Devices and Move Devices CUTOVER) ................................................ 15
Page Design (Only for Lane devices) ............................................................................................................ 20
Tender Parameters (Only Lane devices)...................................................................................................... 23
Extension Application (Only for Lane devices) – CUTOVER FOR LANE DEVICES. ........................ 24
Pay@Table Preinstallation (For Move Devices only) ................................................................................... 27
EMC OPI for Pay@Table Specific Configuration ............................................................................................ 27
Printer Configuration .......................................................................................................................................... 27
Workstations for POS API Configuration .................................................................................................... 30
P@T Employee Configuration........................................................................................................................... 34
OPI Installation for Pay at Table ........................................................................................................................ 37
INSTALL JAVA (PRE-REQUISITE FOR MYSQL) .......................................................................................... 37
INSTALL MYSQL (PRE-REQUISITE FOR OPI)............................................................................................. 37
OPI Installation .................................................................................................................................................... 42
OPI SECURITY PATCH 19.1.1.0 ....................................................................................................................... 49
OPI SECURITY PATCH 19.1.1.7 ....................................................................................................................... 50
OPI Configuration .................................................................................................................................................... 50
Import the settings Template File ................................................................................................................. 50
FreedomPay Antonio Service Installation ....................................................................................................... 54

1
BACK TO INDEX
V1.1 – Released 08/23/2023

Antonio Config File............................................................................................................................................... 54


FreedomPay Pay at Table Service Installation .......................................................................................... 57
Offline PMS Interface (IFC side) ........................................................................................................................ 58
Offline PMS Interface (CAPS/Client Side) ...................................................................................................... 68
Preface ....................................................................................................................................................................... 68
Supported Version ................................................................................................................................................ 68
Requirements ........................................................................................................................................................ 68
Not Supported Function & Features .................................................................................................................. 68
Restrictions ............................................................................................................................................................ 69
Installation (Simphony 19.1 and below) ............................................................................................................... 69
Installation (Simphony 19.2 and Above)............................................................................................................... 76
Configuration of Offline PMS Client (both versions) ............................................................................... 77
List of the configuration settings available: ...................................................................................................... 81
MOVE DEVICES TESTING (Preinstall phase) .................................................................................................. 82
MOVE DEVICES TESTING (Cutover phase) ..................................................................................................... 83
ANOMALIES AND TROUBLESHOOTING SCENARIOS ................................................................................... 85
More than 8 RVCs ................................................................................................................................................. 85
More than 4 RVCs for UPP (Americas) Devices ................................................................................................ 89
SA user and password not working ................................................................................................................... 89
MF_EAME credentials not working after using QueryExPlus .......................................................................... 90
OPI is not properly installing ............................................................................................................................... 91

2
BACK TO INDEX
V1.1 – Released 08/23/2023

NOTES
This guide will be updated as the installation becomes more streamlined and methods are standardized for
each hotel chain. Be mindful of the guide version you are currently reading and take notes of anything
that is not contemplated in each step.

Much like in OPI and FCC installations, POS Simphony can have different devices in a property:
Lane devices (L3000, L5000, L7000, referred to as “Lane Devices” from now on) and/or Move devices
(Move 5000). Depending on the deployment requested by the property staff or indicated by the invoice
email, the installation of either or both options will require different steps, and it is the job of the installer
to be mindful of the process. Because of the nature of each installation being different, this guide aims to
keep the installer on a single line, with clear indications on where and how to proceed according to each
situation.

On some key words, you will find notes that explain the function of certain items, as well as what some
acronyms mean, so that the installer can comprehend the installation process and learn to adapt to
certain situations that may arise. This information comes from both personal and collective experience, as
well as official documentation, linked below.

CHANGELOG
V1. Release – 08/21/2023

V1.1 – 08/23/2023

Syntax corrections.

Troubleshooting scenarios.

Item order changes.

Reference Documentation:
Oracle Simphony - https://docs.oracle.com/cd/F14820_01/doc.191/f15052.pdf

3
BACK TO INDEX
V1.1 – Released 08/23/2023

FLOWCHART

4
BACK TO INDEX
V1.1 – Released 08/23/2023

General Information
This document describes the process to configure and install FreedomPay Credit Cards in Simphony 18.2
and later, currently for Marriott properties.

Scope of Work
Simphony Configuration: This will require proper access to the different environments for the following
modules:

• Enterprise level
o Employee Maintenance
o CAL Packages
• Property and RVC
o Extension Application
o Payments
o Payment Drivers
o Tender Media
o Page Design
o Workstations
o Tender Parameters
o Printers
o RVC Configuration

OPI (Oracle Payment Interface) Required with Pay@Table (Move 5000)


• Download media from the share Marriott CALA-Mexico / Marriott EU / Marriott US
• Install Java JRE 8u152
• Install mySQL 5.7.4
• Install OPI and its subsequent incremental patches.

Offline PMS Interface


• Download media from the share Marriott CALA-Mexico / Marriott EU / Marriott US
• Install Offline PMS Interface (will require ‘sys admin’ CAPS database access)
• Configure Interface IP Address and Port
• Workstation #
• List of tender media which will be exempt from posting (Only Credit Card Tenders), accessible
through EMC.

FreedomPay
• Download media from the share file Marriott CALA-Mexico / Marriott EU / Marriott US.
• Antonio Service Install and configuration.

5
BACK TO INDEX
V1.1 – Released 08/23/2023

PREREQUISITES
1. Configuration Deployment.
Marriot has 4 different types of properties:
o Marriott GPOS
▪ Miemc.simphony.net (http://Miemc.simphony.net/SimphonyApp )
o Marriott Global
▪ Mar01-ohsim-prod.microsdc.com (http://Mar01-ohsim-
prod.microsdc.com/SimphonyApp )
o Starwood
▪ Swdtrans.microsdc.com (http://Swdtrans.microsdc.com/SimphonyApp)
o On-Premise
▪ Application and Database are in local servers at the property.

In the On-Premise cases, most of the time the installer will have to:

▪ Upload the CAL Packages


▪ Create the OPI Default Tender
▪ Upload and Configure the Payment Driver (SPI for Lane Devices)
▪ Upload and Configure the Payment Module (SPI for Lane Devices)
▪ Configure Tenders
▪ Configure Page Design (SPI for Lane Devices)
▪ Configure Workstations
▪ Create and Configure API (for Move Devices)
▪ Employee # (for Move Devices)
▪ Create and Configure API User

Each property will belong to a different host. It is up to the installer to check which EMC client the
property belongs to.

In order to have all EMC Clients installed at the same time, it is recommended to download and
then rename the origin folder for each appropriately (e.g, Marriott EU will be C:\Program
Files\Oracle Hospitality\EMCClient Global), so that the clients can be installed and ran through
different shortcuts.

Once the correct EMC client is downloaded, enter with your credentials.

6
BACK TO INDEX
V1.1 – Released 08/23/2023

2. At the start of the meeting, confirm with your Marriott Contact/Hotel POC:
a. Quantity and types of devices to be installed. (XX Lane devices or XX Move Devices).
b. Hotel does not have any Credit Card transactions running (For Lane Devices Preinstall and
Cutover).
c. Hotel has admin access in order to login to CAPS (Check and Posting Server), OPI (Opera
Payment Interface) server and IFC Server, if applicable.

3. Coordinate with the Hotel Tech Contact the way to get connection to the Server where OPI Services
will be installed. Typically, hotels have a dedicated server for OPI, but it is also possible that they
have chosen to install OPI, Antonio, mySQL and Java in the CAPS Server or the IFC Server.

If only Lane Devices are to be installed, then proceed to SIMPHONY EMC CONFIGURATION and
PREINSTALLATION.

If only Move Devices are to be installed, then proceed to PAY@TABLE PREINSTALLATION.

If both Lane Devices and Move Devices are to be installed, then start from SIMPHONY EMC
CONFIGURATION and PREINSTALLATION.

If the property is cutting over with Lane Devices, then proceed to EXTENSION APPLICATION and
CUTOVER for LANE DEVICES

If the property is cutting over with Move Devices, then proceed to TENDER MEDIA (for Lane Devices
and Move Devices CUTOVER)

7
BACK TO INDEX
V1.1 – Released 08/23/2023

Simphony EMC Configuration and Pre-Installation


CAL Packages (Only for using Lane devices)
IMPORTANT!

You need to make sure you have access to each property with privileges to Override and configure the
Payment and Payment Driver modules as well as Tender Media, Extension Application, Page Design at the
Property levels and some cases in the RVC levels if each RVC will use unique Store IDs, as well as
Employee Maintenance and CAL Packages at the Enterprise levels.

Also, to take note of, within EMC you may have access to all properties. In order to select the correct
property, you must filter the MARSHA code so as not to mistakenly modify any other property.

For Cloud Environments: First check to make sure the CAL packages are already available:

• Select the Enterprise.


• Filter by MARSHA code to make sure you work on the property you need without affecting anything
else.
• Under Enterprise -> Setup tab -> Hardware/Interfaces, select “CAL Package”.

8
BACK TO INDEX
V1.1 – Released 08/23/2023

• Under Custom
o Validate that the CAL Packages are set to deploy for the property you are working on.

• Select CAL Package


• Add Deployment
• Select Property by filtering by name using MARSHA Code
• Click Ok and Save
• Do the same for all CAL Packages (Corresponding to the region)
o FSWS (Latest version)

9
BACK TO INDEX
V1.1 – Released 08/23/2023

o PAL (Customer Facing No Branding)


o RUS (Latest version)

• Save

• Report that the installation step has been completed in the Chat, and continue.

Payment Drivers (Only for using Lane devices)


Validate that you have access to override and configure the Payment Drivers (when entering, options such
as “Add” are not greyed out).

• Navigate to the property level, select the setup tab, under Hardware/Interfaces select Payment
Drivers.

10
BACK TO INDEX
V1.1 – Released 08/23/2023

• Right Click on the row that you need to override (Generally is named VisaD, OPI or SPI)
• Select Override Record, Using Existing Record.

• Double click the row to enter record view


• Change the name to SPI
• In Content type select “Secure DLL Configuration”/”DLL”
11
BACK TO INDEX
V1.1 – Released 08/23/2023

• Import from a file


o Navigate to your EMCClient folder and select OPIPayment.dll (search within
C://Program Files/Oracle Hospitality)
• In Description type SPI/SPI Payment
• Set SPI Interface to “True”
• Set Security Settings to “Use Https with No Certificate Validation”
• Set Currency to the country Numeric ISO code. This Link provides ISO currency codes which need
to be set up. Ask the property for the correct currency they will be using (e.g, Puerto Rico uses US
dollar, meaning they will use the code 840).
• Set the Merchant Number to the StoreID provided by FreedomPay or the Property in the chat.
o Of note: If the RVCs have different StoreIDs, then use the first one given.
• Set the Primary Host to “HTTPS://127.0.0.1:443”
• Save the changes.

If each RVC has a different StoreID, the installer will have to modify the same settings for each Revenue
Center within EMC by accessing each one separately and going through the same changes.

12
BACK TO INDEX
V1.1 – Released 08/23/2023

• Report that the installation step has been completed in the Chat, and continue.

Payment Module (Only for Lane devices)


Validate that you have access to override and configure the Payments.

• Navigate to the property or RVC level, select the setup tab, under Hardware/Interfaces select
Payments.

13
BACK TO INDEX
V1.1 – Released 08/23/2023

• Right Click on the row that you need to override (Generally is named Credit Cards).
• Select Override Record, Using Existing Record.

14
BACK TO INDEX
V1.1 – Released 08/23/2023

• Double click the row to enter record view


• Ensure that you are modifying the SPI driver.
• Change the name to SPI
• In Content type select #3 - DLL
• Import from a file
o Navigate to your EMCClient folder (search within C://Program Files/Oracle
Hospitality) and select Micros.Payment.LoadableCreditCardModule.dll
• Set Incremental Authorizations to “True”

• Save

• Report that the installation step has been completed in the Chat, and continue.

Tender Media (for both Lane Devices and Move Devices CUTOVER)
Validate that you have access to override and configure the Tender Media.

• Navigate to the property level, select the configuration tab, under Sales, select Tender Media.

15
BACK TO INDEX
V1.1 – Released 08/23/2023

• Select the Tenders used for Credit Cards.


• Override if need it, Right click select “Override Records” and “Use Existing Records”.

16
BACK TO INDEX
V1.1 – Released 08/23/2023

• For each Credit Card Tender go to Credit Card Options.


If there is only one option for Visa/MasterCard/etc, complete it with all of the corresponding
CC lists in the preambles table, but pay attention as there may be another option for Visa
Debit or others.
• Set up the Preambles according to the table below.

17
BACK TO INDEX
V1.1 – Released 08/23/2023

18
BACK TO INDEX
V1.1 – Released 08/23/2023

If the property will have Move Devices:

• Un-link the interface under the Interface Options:


IMPORTANT: This is done in the cutover phase for Move Devices Only. This is
because, if done in the preinstallation, Credit Cards will be processed through POS
OPI and not PMS, and will leave the property without the ability to process Credit
Cards until the Cutover phase.

• Save

• Report that the installation step has been completed in the Chat, and continue.

To finish the Cutover with the Move Devices, jump to Move Devices Testing (Cutover Phase).

19
BACK TO INDEX
V1.1 – Released 08/23/2023

Page Design (Only for Lane devices)


Validate that you have access to override and configure the Page Design

• Navigate to the property level, select the Configuration tab, under User Interface, select Page
Design (The design may differ from location to location).
• Select Payment Screen, it can also be found as EMV CC screen.
• If present, validate that you have Auth Credit Card, Card Finalize and Card Refund with the
following configuration:

o “Auth Credit Card”/”CC AUTH”/”Authorize Credit Card” (the argument should say:
CreditDebit:Loadable CreditAuthOnly)
Type: Payment Tenders
In the field below it, click on the right pointing arrow, select:
0 – None
On Payment Type, select CreditDebit: Loadable
On Functions, select CreditAuthOnly

20
BACK TO INDEX
V1.1 – Released 08/23/2023

o “Card Finalize”/”CC CLOSE” (no argument)


Type: Function
In the field below it, click on the right pointing arrow, select “Transaction”, and on the
right field, select “CCard Finalize”

o Card Refund (Argument: CreditDebit CreditAuthAndPay)

21
BACK TO INDEX
V1.1 – Released 08/23/2023

Type: Function
0 – None
On Payment Type, select CreditDebit: Loadable
On Functions, select CreditAuthAndPay

• Save

If any of these buttons are missing, you will have to create the space within the Payment/EMV CC screen
and add the 3 buttons. If needed, you can remove the Visa, Mastercard, AMEX, etc buttons.

Be mindful of the design and try to follow the same as the property had previously.

You can change the colour of each button on the “Style” section, on its right pointing arrow.

22
BACK TO INDEX
V1.1 – Released 08/23/2023

• Report that the installation step has been completed in the Chat, and continue.

Tender Parameters (Only Lane devices)


Validate that you have access to override and configure the Tender Parameters.

• Navigate to the property level, select the Setup tab, under Parameters, select Tender Parameters

• If not already, Create Override

23
BACK TO INDEX
V1.1 – Released 08/23/2023

• Select the Configuration Tab and set the Default Payment Tender to OPI Default

• Save

• Report that the installation step has been completed in the Chat, and continue.

This concludes the Preinstallation for Lane Devices. No software is needed to be


installed.
If the property is also preinstalling Move Devices, proceed with Pay@Table
Preinstallation.
The Cutover is usually done at a later date.
Extension Application (Only for Lane devices) – CUTOVER FOR LANE DEVICES.
Validate that you have access to override and configure the Extension Application.

24
BACK TO INDEX
V1.1 – Released 08/23/2023

• Click on the green sign


• Set Record Name to “FSWS” and click OK

• Double click the new created record


• Click on Insert Application Content

25
BACK TO INDEX
V1.1 – Released 08/23/2023

Before proceeding:

The installer must check on the invoice and/or ask the property staff what version of EMC they are using,
as that will dictate the following .dlls that the installer will be using for the cutover.

If the property is using EMC 18.2, the installer has to download and load the files off of
“FreedomPayRemoteController” within the Marriott CALA-Mexico / Marriott EU / Marriott US fileset. (look
for the “FSWS” folder for each region/country).

If the property is using EMC 19.4+, the installer has to download and load the files off of
“FreedomPayRemoteControllerV2” within the Marriott CALA-Mexico / Marriott EU / Marriott US fileset. (look
for the “FSWS” folder for each region/country).

• Use the following information


o Zoneable Key: FreedompayRemoteController
o Description: FreedompayRemoteController
• Import from the file “FreedompayRemoteController.dll” from the Extension Application previously
downloaded from the share
o Disk File Name: FreedompayRemoteController.dll
• Save
• Again, click on Insert Application Content
• Use the following information
o Zoneable Key: FreedompayRemoteInterface
o Description: FreedompayRemoteInterface
• Import from the file “FreedompayRemoteInterface.dll” from the Extension Application previously
downloaded from the share
o Disk File Name: FreedompayRemoteInterface.dll
• Save
• When completed it should look like this

In order to test the devices, the hotel staff should:


• Refresh the database from the CAPS.
• Start testing transactions from each workstation attached to each device by creating a transaction
and using a Credit Card.

Troubleshooting: If while trying to reload the database, the workstation shows a connection error to the
likes of “Could not connect to net.tcp://127.0.0.1:9095 (or any other port different from 8081), refresh the
database, if that does not work, restart the workstation and try again. If the EMC settings are correct, then
refreshing the database and restarting the workstation should force the devices to download the dlls.

• Report that the Lane Devices Testing has been completed in the Chat, and/or continue with the
Move Devices Cutover.

26
BACK TO INDEX
V1.1 – Released 08/23/2023

This concludes the Cutover for Lane Devices. If the installation


also includes cutting over Move Devices, continue with
Pay@Table Cutover.

Pay@Table Preinstallation (For Move Devices only)


Before proceeding with the Preinstallation, ensure you have the following information:

• How many Move Devices will be installed.


• Under which RVCs (Revenue Centers) will each Move Device work. Take note of them or ask the
property staff to write them down in the chat of the call. Always corroborate this information with
FreedomPay, as there might be differences in RVC names or StoreIDs.
• If there are different StoreIDs for each RVC.
• Where would the property like to have POS OPI Installed. The property will usually have a POS OPI
dedicated server, but they may also want to have it installed in the IFC server or CAPS.
• That you are connected to the correct servers: CAPS, OPI, IFC.
• That there is a clear connection between these servers by pinging from the OPI to the CAPS and
the CAPS to the IFC Server.
• If the property has already set up the Move Devices to properly connect to Wi-Fi. This is the
responsibility of the property to do before the Preinstall, and FreedomPay should provide with
instructions on how to set them up prior to engagement. By the end of the setup, the Move Devices
should say “This lane closed”, as the Antonio Interface has not yet been fully installed.

EMC OPI for Pay@Table Specific Configuration


Printer Configuration
Validate that you have access to override and configure Printers.

• Navigate to Property > Setup Tab > Hardware/Interfaces > Printers

27
BACK TO INDEX
V1.1 – Released 08/23/2023

• Click on the green insert sign, hit ok on the next screen.

28
BACK TO INDEX
V1.1 – Released 08/23/2023

• On the next screen, the workstation must be the POS API workstation recently created, and the
printer type must be Local Disk File.
• On Printer Configuration, in File name, type in “C:/Micros/Simphony/CAPS.PRT.TXT” Other variants
are “Journal.txt”, “Record.txt”.

• Save

29
BACK TO INDEX
V1.1 – Released 08/23/2023

• Report that the printer has been set up in the Chat, and continue.

Workstations for POS API Configuration


Validate that you have access to override and configure the Workstations.

• Navigate to your Property > Setup Tab > Hardware/Interfaces > Workstations

• Right Click on CAPS WS/SERVER and choose Copy (Make sure you select the correct workstation).

• Right click again on the CAPS Record and chose QUICK ADD > Create Record from Copy

30
BACK TO INDEX
V1.1 – Released 08/23/2023

• Double Click on the new record to go to form view

• Choose # 3-POS API Client under Type and for ServiceHost ID Choose the original workstation you
copied from. Take note of the IP address as you will be using it later.
• If available, make sure that the option “Enable Simphony Transaction Services 1” is checked.

• You can check the Servicehost ID in the workstations list to make sure you selected the correct
workstation.

• Head to the Revenue Centers tab, and make sure that the POS API workstation has access to all the
Revenue Centers under which the Move Devices will be working.

31
BACK TO INDEX
V1.1 – Released 08/23/2023

• Save

• If you do not know if the POS API workstation has been created already, check if one of them has
“POSAPI Client” in the Type column, or “Pay@Table-API” in the Workstation class column, and that
it is a copy of the CAPS server (by checking the IP address).
• If no workstation shows up as CAPS, the installer can check EMC > Property > Property Parameters
> Workstations and see which one says “Check and Posting”. That one should correspond to the
CAPS.

• Save

• Because the File Printer has already been set up, click on the Printers Tab.
• On it, click on the Select button in the Customer Receipt Printer, and select the new File Printer you
have just created. Then, click on the “Set for All Printers” Button under it.

32
BACK TO INDEX
V1.1 – Released 08/23/2023

• Save
33
BACK TO INDEX
V1.1 – Released 08/23/2023

• Report that the installation step has been completed in the Chat, indicating the IP Address of the
POS API workstation created and the Printer is assigned, and continue.

P@T Employee Configuration


Validate that you have access to override and configure the Employees.

• Navigate to Enterprise > Configuration > Personnel > Employee Maintenance

• Search for Object Number 999900006 and Double Click on the record found.
Bare in mind that there could be variants such as Employee number 3, or employee number
999900001.

34
BACK TO INDEX
V1.1 – Released 08/23/2023

• Check to make sure your property is not listed


• Select Property Summary and click Insert

• Filter by the property Code


• Select the property
• Click Ok

• Under General Tab set the Emp Class to #2 All – MANAGER


• Then select Operators Tab

35
BACK TO INDEX
V1.1 – Released 08/23/2023

• Select Insert

• Select All and OK

• Save

• Report that the Pay At Table Employee has been assigned to the property in the Chat, and
continue.

36
BACK TO INDEX
V1.1 – Released 08/23/2023

OPI Installation for Pay at Table


INSTALL JAVA (PRE-REQUISITE FOR MYSQL)
• Check/ask if the OPI credentials are available. The installer may need to look for the info file within
the C:/ Drive, documents folder, other users’ folders or the CAPS server. If the hotel staff cannot
provide with valid ones, the installer will have to fully uninstall OPI and mySQL, and reinstall them
using the default username and password or the ones provided by the property in the first place.
• From the Pre-Requisites Package, run the jre-8u152-windows-x64.exe

• Follow defaults prompts until you get “You have successfully installed java”

INSTALL MYSQL (PRE-REQUISITE FOR OPI)


• From the OPI/Pre-requisites package run the mysql-installer-community-5.7.40.0.msi
• Select Server Only and click next

37
BACK TO INDEX
V1.1 – Released 08/23/2023

• Choose the MySQL Server 5.7.40. then click Execute

• Click next after the Status says “complete”

38
BACK TO INDEX
V1.1 – Released 08/23/2023

• Click next to advance to the Type and Networking options. Leave defaults in place and click next.

• Enter the password for the root account as opiadmin19.1 (or the ones provided previously)
then click next.

39
BACK TO INDEX
V1.1 – Released 08/23/2023

• On the Windows Service Screen leave the defaults in place then click next.

• Select “No, I will manage the permissions after the server configuration” and click Next.

40
BACK TO INDEX
V1.1 – Released 08/23/2023

• Click Execute on the Apply Configuration Screen.

• Click Finish on the last screen of the MySQL Installation then click finish again to exit.

41
BACK TO INDEX
V1.1 – Released 08/23/2023

OPI Installation
• From the OPI/Pre-requisites package, run the OraclePaymentInterfaceInstaller_19.1.0.0.exe, then
click ok for the English Language default.

• Click Next on the welcome screen, then click next on the Pre-requisites screen.

• Leave the selection on “Complete” then click next, leave the default folder in place and click next.

42
BACK TO INDEX
V1.1 – Released 08/23/2023

Click on Install to proceed and the installation will begin.

• MySqL should be selected as the database then click next, then leave the default port then click
next.

• Enter root as the Login ID and opiadmin19.1 as the password for the Database Server Login then
click next.
• NOTE: Be aware that, if the property has provided their own credentials, you must adhere to those
changes.

43
BACK TO INDEX
V1.1 – Released 08/23/2023

• Enter opidbuser as the and Opidbuser191! as the password, confirm the password for the
Database User then click next
• NOTE: Be aware that, if the property has provided their own credentials, you must adhere to those
changes.

• You should see a “Database Connection Successful, then click ok, then you should see “Database
Configuration operation successful” then click ok again.

44
BACK TO INDEX
V1.1 – Released 08/23/2023

Enter opiconfiguser as the username and OpiConfiguser191! as the password for the Super User
account for the configurator then click next-

• NOTE: Be aware that, if the property has provided their own credentials, you must adhere to those
changes.

• You should see a “Create Super User Operation Successful, then click ok

45
BACK TO INDEX
V1.1 – Released 08/23/2023

• Accept the default connections for the Configuration tool Connection and click next

• Enter OraclePaymentInterface191! As the passphrase, then confirm and click next

46
BACK TO INDEX
V1.1 – Released 08/23/2023

• Select “POS” and the instance and “Native Driver” then click next

• Enter OraclePaymentInterface191! As the passphrase, then confirm and click next

47
BACK TO INDEX
V1.1 – Released 08/23/2023

• Accept the default settings then click next

• Click Close on the next screen

48
BACK TO INDEX
V1.1 – Released 08/23/2023

• Restarting the CAPS/OPI server is not necessary. Instead, you can restart the OPI Service.

OPI SECURITY PATCH 19.1.1.0


WARNING!! DO NOT SKIP this step which addresses security issues with Java.

• From the FP-OPI_19.1 Package run the OraclePaymentInterfaceInstaller_InterimPatch_19.1.1.0.exe


• Click next, then yes on the next screen.

You should see a “database upgrade operation was successful” message, click ok to exit

49
BACK TO INDEX
V1.1 – Released 08/23/2023

OPI SECURITY PATCH 19.1.1.7


WARNING!! DO NOT SKIP this step which addresses security issues with Java.

• From the FP-OPI_19.1 Package run the OraclePaymentInterfaceInstaller_InterimPatch_19.1.1.7.exe


• Click next, then yes on the next screen

• You should see a “database upgrade operation was successful” message, click ok to exit.

OPI Configuration
Import the settings Template File
• Launch the OPI Configurator C:\OraclePaymentInterface\v19.1\Config\LaunchConfiguration.bat
• Login as opiconfiguser (unless the property provided with their own credentials)

50
BACK TO INDEX
V1.1 – Released 08/23/2023

• Navigate to the Import Configuration Menu then click import, then click ok again.

From the fileset Package choose the correct OPI.XML file for that region, then click ok.

• In the OPI Configuration navigate to Merchants > Configuration and delete one of the entries (if
more than one are present) and modify the other by pressing on the wrench button.

51
BACK TO INDEX
V1.1 – Released 08/23/2023

• Update the Highlighted Fields for your location starting with the FreedomPay StoreID, then click
save when finished.

• Navigate to the Pay-At-Table Devices tab and you will find two PAT devices for two RVCS already
prepopulated. Update the RVC ID to match your RVC numbers in EMC.

• Make sure you add the RVCs in sequential numbers so the Device ID will match the order, the
Device ID is unique to the RVC. Ex. You have 2 RVCs, 101 and 201, sequentially the Device ID
should be 1111111 for 101 and 2222222 for 201. The Device IDs are 7 digits long, when you get to
the 10th Device ID then you need 1010101, 2020202, Etc. Make a note of the Device IDs as you will
need them for the FreedomPay Pay-At-Table Config file.

• Navigate to the Settings Tab and set the IP of the POSAPI Workstation created in EMC. After that,
access that full website from a web browser. If it cannot be accessed (it should direct to what
appears to be an XML file), then make sure there is communication between the OPI server and the
CAPS by pinging it, and that the port is opened.
• Make sure the Employee fields are the same as the employee used for P@T in EMC (Employee N°
999900006) and Save.

52
BACK TO INDEX
V1.1 – Released 08/23/2023

• Navigate to the Pay-At-Table > Service Settings tab then update the certificate password to
PT@bl12016
• Set Mode to HTTP
• Uncheck Enable Secure Connection
• Uncheck TLS 1.2
• Save

• Navigate to the Pay-At-Table > POS API Settings tab then add the Tender Media # from EMC for
each Credit Card Tender, Print Check and Service Charge use for Tips in EMC and Save.

53
BACK TO INDEX
V1.1 – Released 08/23/2023

• Restart the OPI Service

• Report that the OPI has been installed and configured in the Chat, specifying the IP Address where
OPI was installed, and continue.

FreedomPay Antonio Service Installation


Antonio Config File
The configuration files provided in each region pertains to the Marriott standards, including ports being
used, currency and other particular settings.

The following tags need to be populated with site specific information received with the Site Readiness
Survey. Please note, examples below refer to an installation where 2 RVCs are required. Each OPI instance
is limited to 8 RVCs. If more than 8 RVCs are required, a new OPI Instance is required. This will be
contemplated in the ANOMALIES AND TROUBLESHOOTING SCENARIOS section.

It is suggested that the installer downloads Notepad++ from here, as it will greatly aid in editing the file.

• SegmentList: Enables devices to be used in multiple RVCs. Each number relates to an individual
Segment ID. This will vary according to how many RVCs will be using the Move Devices; If there
are 4 RVCs, then there should be 4 segments. This example shows 2 RVCs being used.

54
BACK TO INDEX
V1.1 – Released 08/23/2023

• POS.TipsSuggestpct: Defines suggested Tip Percentage displayed. Unless indicated otherwise by


the property POC, leave this as default.

• POS.LoginType: Operators are requested to sign into device with OPI integrations. Options
available are Key or Swipe. Ask the property POC for clarification on which method they would like
to use, but usually it is the swipe one (the employee swipes their Micros card before a transaction).

• Saf.FloorLimit: Relates to Transaction Store and Forward. Allows a limit of offline transaction
approval if communication to Freeway Web Service is down. Leave this as default, as it can allow
for exploitation from the customer.

• Saf.Post.AllowOffline: Relates to Post Payment Store and Forward. Enables ability to store
checks that are unable to close on Simphony. Once available, Saf.Post.AllowOffline will post and
close check.

• OPI.Url: IP address where OPI is installed. It may differ if Antonio Service and OPI are not
installed on the same server.

• OPI.DeviceID: Relates to the Terminal ID specified in OPI. This is essential to the standard
configuration and must follow the same order as how it was set up in OPI. Example enables for 2
RVCs. Add or Remove line items as required to match the Segments/RVCs.

• OPI.MerchantID: Specify Store ID for each RVC. In some Marriott properties, the StoreID can be
different for each RVC, always corroborate this information prior to the preinstall. Add/Remove line
items as required (matching with the amount of Segments/RVCs).

55
BACK TO INDEX
V1.1 – Released 08/23/2023

• POI.enableRvcSelection: It needs to have a value of true as it will allow the Move Devices to
switch between RVCs. It needs to reflect the number of RVCs (if there are 6 RVCs, then there
should be 6 lines, each numbered 1 to 6).

• POI.RVCList: Defines RVC selection for Flexible RVC mappings, this means that the devices will be
able to change RVCs without an issue, which is ideal. Remove line items as required (NOTE: UPP
Devices (Americas – Ports 7001) have a limitation of 4 RVCs, while RAM Devices
(Europe – Ports 6001+) have a limitation of 8 RVCs). For more than 4 RVCs with UPP
Devices, see the ANOMALIES AND TROUBLESHOOTING SCENARIOS section. Bear in
mind that the order of the RVCs matters and must follow the same order as it is within
EMC and OPI. The name of each RVC can be shortened so that the device can fully display the
name.

• OPI.TerminalId: It needs to have a value of 1.

• OPI.TSEmployee: Specify Transaction Services employee ID as specified in OPI, it should be set


to 999900006 as stated previously.

• OPI.TSURL: Assign IP address of Simphony POSAPI client. Refer to EMC > Workstations

• POS.printItemizedReceipt: It needs to have a value of true. This indicates how much


information is displayed in the final receipt.

• OPI.EmployeeRVC: Defines RVC ID as specified in OPI. XXX refers to RVC ID in OPI > Merchants
56
BACK TO INDEX
V1.1 – Released 08/23/2023

• OPI.AutoGetCheckNumber: This indicates whether property staff will have to manually select
the check number. When set to auto, property staff will get the last posted check.

FreedomPay Pay at Table Service Installation


• Run the “FP ports.cmd” located in the Prerequisites if you haven’t done so already.
• Run the FPPayAtTableServiceInstaller.exe
• Select Next on the Welcome Screen.

• Enter the DMP Key Supplied by FreedomPay and click Next.

Dmp key: 518083a7-19e6-4e5b-8209-460bd6abecb7

• Click Finish

57
BACK TO INDEX
V1.1 – Released 08/23/2023

• Validate the service is installed correctly. If when trying to restart the services, it fails, then there
could be a Syntax error somewhere in the config file, or an Antivirus software is possibly blocking
the file from running.

• Once the service is installed, the PAL Packages need to be installed in the workstation.

Navigate to the folder where the PayAtTable installer is located and find the correct PAL packages or check
the share point link to the corresponding region. The ones the installer should use are the Customer Facing
(no Branding). These files must be moved to C:/Programdata/Freedompay/Atlas/Antonio/Pal.

It is imperative that the installer uploads the correct set of PAL Packages as they will dictate the language
and the functioning standards for each region.

After restarting the Antonio services, the Move Devices that are properly connected to Wi-Fi and charged
should start rebooting and downloading the PAL Packages to each device. The final screen should be
“Secured by FreedomPay” and then allow the property to select the RVC.

• Report Antonio has been installed and configured in the Chat, specifying the IP Address where
Antonio was installed, and continue.

Offline PMS Interface (IFC side)


Once given access to the IFC server, locate the POS Interface. Usually, it can be located in the desktop as
“IFC Shortcut”, but if that is not the case, it can also be located within D://Fidelio/IFC8/INNCODE/SPH as
an .XML file.

• Create a Backup of the entire SPH folder (copy and paste in the same folder).
• Stop the POS Interface if it is running as a Service; look for “IFC8Service
(Inncode_SPH_ifc8config.xml)”. Inform the property that the POS Interface will be down for a few
minutes, meaning they will not be able to process charges in Simphony.

58
BACK TO INDEX
V1.1 – Released 08/23/2023

• Open the .XML file within the original folder with IFC8.

You should see each interface within the property. If there are many running within the IFC server, ensure
the one you are modifying corresponds to the correct property.

• Head to Properties > Configuration > Log in with Windows Admin Credentials (ask for the property
POC to access or write them down in a notepad, as you may be accessing it a few times).

59
BACK TO INDEX
V1.1 – Released 08/23/2023

• Clone the existing IFC1 object by right clicking > Clone Node

You should get two error messages:

• Click Ignore
60
BACK TO INDEX
V1.1 – Released 08/23/2023

• Click Retry

Once the IFC2 node is created, the installer must change the port to the Marriott Approved one, which is
7138.

• IFC2 > Physical Layer > Port = 7138 > Click somewhere else > Apply

Once that is done, both IFC nodes must have the Parameter “Required” set to N (NO).

• IFC1 > Required=N > Click somewhere else > Apply

61
BACK TO INDEX
V1.1 – Released 08/23/2023

• IFC2 > Required=N > Click somewhere else > Apply

After that, route the Workstation ID of the Offline IFC to the IFC2 object. In order to do that, the installer
must:

• PMS1 > Right Click on WSNumX parameter and select Clone & Rename Item > Rename as
WSNum000000099 > Set Value = IFC2 > Apply

62
BACK TO INDEX
V1.1 – Released 08/23/2023

After that, clone the WSNumX parameter again and rename it as WSNum99 and set the Value to IFC2

• PMS1 > Right Click on WSNumX parameter and select Clone & Rename Item > Rename as
WSNum99 > Set Value = IFC2 > Apply

63
BACK TO INDEX
V1.1 – Released 08/23/2023

The installer must then change the LA_Timeout Parameter in each IFC Object from its default value of
3000 (ms) to 6000

• IFC1 > Application Layer > LA_Timeout = 6000 > Apply

64
BACK TO INDEX
V1.1 – Released 08/23/2023

• IFC2 > Application Layer > LA_Timeout = 6000 > Apply

The installer must then mark the IFC objects to identify the Online and Offline Interface.

• IFC1 > ObjCaption = IFC1 Rooms > Apply


• IFC2 > ObjCaption = IFC1 Offline > Apply

65
BACK TO INDEX
V1.1 – Released 08/23/2023

• Save and replace the original .xml file.

66
BACK TO INDEX
V1.1 – Released 08/23/2023

The POS Interface should now look like this. The IFC2 Offline tab at the bottom, if extended, should light
up on the Link every 30 minutes once the Client is installed.

• Report that Offline IFC Interface has been created in the Chat, and proceed.

67
BACK TO INDEX
V1.1 – Released 08/23/2023

Offline PMS Interface (CAPS/Client Side)


Preface
The PMS IFC Client is an alternative Interface method for non-Room-Charges (i.e. Cash, Credit-Cards
and so on). It cannot and will not replace the well-known enhanced interface for Room-Charges.
The PMS IFC Client is limited to interfaces to MICROS PMS products, namely OPERA PMS and Suite8.
Together with the client application a status web page is distributed, this provides the ability to always
have an overview of the status of the PMS client application.

Supported Version
• Simphony 2.10.3 and higher
• WIN 32 Client with Windows 7 32/64 or Windows 10 32/64 as CAPS/ PMS Client
• Database SQLExpress 2008 R2 or SQLExpress 2012

Requirements
• The application must reside on the Simphony 2 CAPS which runs by default SQLExpress 2008
R2 or SQLExpress 2012.
• Check and Posting Details must be purged after one week, this is configured by default on each
Check and Posting Workstation.
• This application does not support circumstances where multiple Taxes by item are enabled. It
supports a maximum of 8 Tax Itemizers per check. Any Add-On Tax in the range 9 to 64 is
automatically added to Tax Itemizer 8.

Not Supported Function & Features


• Performing any Reopen Closed Check
• Performing any Void Closed Check from previous Business-dates
• Performing any Adjust Closed Check from previous Business-dates
• Adding Service Charge, Discount and Menu Item after partial payment

The following settings must be checked in EMC before the Offline PMS Interface is running:

• Require Finalization of Check after Partial Tender.

Open EMC and select Setup >


Control Parameters – Options
Option Bit 19 – Must be ON

68
BACK TO INDEX
V1.1 – Released 08/23/2023

• Taped Totals i.e. Post Offline Transaction with Actual Transaction Time

Restrictions
Additional restrictions which are currently not outlined below may apply if a nonstandard installation may
be processed.

• The MF_PMS_IFC_Client.exe needs to run on the Simphony2 CAPS client. It cannot be used from
Simphony server nor the Database Server (in case of separate Application and Database Servers).
• The MF_PMS_IFC_Client.exe will typically only post once a day all checks to the PMS (i.e. after
Start-Of-Day of the POS but before End-Of-Day of the PMS). But the application can also be
installed as Windows service. With this, the installer can set the time, in the settings xml file, when
the service posts checks to PMS. By default, this is done every 30 minutes.
• MF_PMS_IFC_Client.exe cannot be used as Windows service and console application at the same
time.
• If the posting process is running you cannot start another posting process.
• On new installations the RunFiExportForPrevDay function will not work for one day to prevent
double postings. This limitation will change on the next day.
• On a new installation, checks closed before installation Date/Time will not be posted.
• The application haves a Summarylog.txt log file for night auditors under the Maintenance folder
• If the AutoReporting parameter is active, the Maintenance folder will be watching for the files
start.now, repostStatus2.now and repostStatus3.now to exist:
o start.now: if exists, will run the MF_PMS_IFC_Client.exe with default settings
o repostStatus2.now: if exists, will delete status 2 record from tables and will run the
MF_PMS_IFC_Client.exe again
o repostStatus3.now: if exists, will delete status 3 record from tables and will run the
MF_PMS_IFC_Client.exe again
• It is not recommended to run the application in a timeframe cycle lower than 15 minutes.

BE MINDFUL OF THE VERSION YOU WILL BE INSTALLING; Only download the


Marriott Approved versions, which are available in the FreedomPay Sharepoint
(specified above).
Depending on the Simphony version the property is using (usually 18.2 or 19.4),
different clients of the Offline PMS need to be used.
Click here for Simphony 19.1 and below

Click here for Simphony 19.2 and above

Installation (Simphony 19.1 and below)


You will need SYSADMIN Credentials for the SQLExpress in CAPS

Marriott standard at the moment is:

69
BACK TO INDEX
V1.1 – Released 08/23/2023

- User: SA or admin_user or wsadmin


- Password: Marriott18.2.2Now! or Default: #1mymicros

Bare in mind that if these credentials do not work, the installer should ask the property’s POC for them to
log in with their own. If they do not have credentials and the provided ones here do not work, then
proceed to ANOMALIES AND TROUBLESHOOTING SCENARIOS.

• Edit the Add User File


o Username: PayatTableSQL
o Password: At installation set to [MARSHACODE]FP2023ICECREAM
o Example: LONPRFP2023ICECREAM
• Run QueryExPlus.exe
If QueryExPlus is missing, the installer can download it from here.
• Connect to the local database with the SYSADMIN credentials and click Connect

• From the Add User File copy the newly edited password.

• Pasted in the Query Window


• Select All and Execute

70
BACK TO INDEX
V1.1 – Released 08/23/2023

• You should see message on the Message Window


• Minimize the program

• Run Setup_PMS_IFC_Client_Service_XXXX.exe on your CAPS workstation and click Next

71
BACK TO INDEX
V1.1 – Released 08/23/2023

• Click Install

• Click Finish

72
BACK TO INDEX
V1.1 – Released 08/23/2023

• When the setup has finished to copy the required files, the “Finish” button will display the following
message BUT DO NOT CLICK OK YET!

• Navigate to C:\Micros\Simphony\Custom\MF_PMS_IFC_Client\Tools
• Right Click on “Create_MF-EAME_Db.sql” file and Edit

• Select all the text, right click and copy

73
BACK TO INDEX
V1.1 – Released 08/23/2023

• Maximize the Query ExPlus application


• Clear previous script from the Query Window
• Paste in the copied script into the Query Window
• Select All and Execute

• You should see message on the Message Window and close the QueryExPlus App

• Now go to the Offline PMS Install and click OK to finish the install

74
BACK TO INDEX
V1.1 – Released 08/23/2023

• On the LocalDB tab set the UID to PayatTableSQL


• Password: [MARSHACODE]FP2023ICECREAM the password you created earlier

• Select the CPServiceDB tab and set the UID PayatTableSQL


• Password: [MARSHACODE]FP2023ICECREAM the password you created earlier

• Select the MF_EAME Tab, select and copy the Alias


• Paste it in:
o Catalog
o UID
o Password
o Confirm Password
75
BACK TO INDEX
V1.1 – Released 08/23/2023

• Click Confirm

If for some reason the credentials do not work (occurs from bad copy paste), head to ANOMALIES AND
TROUBLESHOOTING SCENARIOS.

Installation (Simphony 19.2 and Above)


• Run PMS_Client_Setup.exe on your CAPS workstation and click Next. The process is more
streamlined and does not require the running of scripts nor setting up the MF_EAME database
manually.
• Tick on “Execute DB Admin Task” and Next.

76
BACK TO INDEX
V1.1 – Released 08/23/2023

You will need SYSADMIN Credentials for the SQLExpress in CAPS

Marriott standard at the moment is:

- User: SA or admin_user or wsadmin


- Password: Marriott18.2.2Now! or Default: #1mymicros

Bear in mind that if these credentials do not work, the installer should ask the property’s POC for them to
log in with their own. If they do not have credentials and the provided ones do not work, then proceed to
ANOMALIES AND TROUBLESHOOTING SCENARIOS.

Configuration of Offline PMS Client (both versions)


• Configure the application
o Set Workstation to 99, according to Marriott standards.
o Insert the IP from the Opera IFC8 (ask the PMS member involved in the OPI Cutover or ask
for access to the IFC server)
o Listening port for the Offline Interface, Marriott standards indicate port 7138.
o Click Save

77
BACK TO INDEX
V1.1 – Released 08/23/2023

• Navigate to C:\Micros\Simphony\Custom\MF_PMS_IFC_Client
• Right Click on the MF_PMS_IFC_Client.xml and Edit

• Validate all settings.


• Add all Tender Media from EMC separated by “,” Except the Credit Card Tenders.
Note: In this link, you will find a .txt file which contains all Tender exceptions from 1 to
150.000. This will save time when creating the exceptions. Copy and paste the entire
contents of the file and replace the “<ExcludeTender>x,x </ExcludeTender>” line.

78
BACK TO INDEX
V1.1 – Released 08/23/2023

• Save.
• Restart MF_PMS_IFC_Client_Service (can be found as either “Micros-Fidelio Offline PMS IFC
Service” or “Oracle FBGBU Offline PMS IFC Service”.
79
BACK TO INDEX
V1.1 – Released 08/23/2023

80
BACK TO INDEX
V1.1 – Released 08/23/2023

List of the configuration settings available:

In order to check if there is a connection between the Offline PMS in the IFC server and the Client installed
in the CAPS, the installer can run the software from the command line:
C:\Micros\Simphony\Custom\MF_PMS_IFC_Client>MF_PMS_IFC_Client.exe

The final result should look like this:

81
BACK TO INDEX
V1.1 – Released 08/23/2023

If there is no connection between the Offline PMS Client and the IFC side, ping the IP address and telnet
using the port 7138. The installer may need to open the ports manually before continuing.

• Report that Offline PMS Client is running and communicating with the Offline IFC in the Chat, and
continue with the Testing.

MOVE DEVICES TESTING (Preinstall phase)


In order to test, indicate the following to the property staff:

1 – Head to a workstation on a Revenue Center.


2 – Open a Check and copy the Check Number.
3 – Send it to the Move Device.
4 – On the Move Device, select the same RVC where it was created and have the property staff
swipe their Micros Card (or key in their employee number). It should be the same employee that
created the Check in the workstation.
5 – Select the check created using the Check Number copied.
6 – Process a payment through the Move Device with something cheap.
7 – Once the payment goes through, and does not appear in the workstation anymore (indicating
that the check has indeed been closed), then proceed with a full refund of that amount (create a
check with a negative amount).
8 – Ask property staff or Marriott POC to check the FreedomPay Portal to see if the transaction is
coming through.

If it is, then proceed with the remainder of the Move Devices.

• Once all Move Devices have been tested, the Preinstallation is complete.
• If testing was not complete, clarify it in the notes and the reason why, so that the engineer in
charge of the Cutover can follow through with the process.

82
BACK TO INDEX
V1.1 – Released 08/23/2023

Before leaving the call, you must retrieve the following files for the completion email:
• OPI.xml config – You can export this from OPI itself, rename it as [INNCODE]_OPI.xml
• AntonioService.exe.config – You will find this file in C:/Program Files
(x86)/FreedomPay/Antonio
• MF_PMS_IFC_Client.xml – You will find this file in C:\Micros\Simphony\Custom\MF_PMS_IFC_Client
in the CAPS server.

MOVE DEVICES TESTING (Cutover phase)


At the Cutover phase, the installer must:

• Unlink the PMS Interface for the CC Tenders in EMC (as covered in the Tender Media section).
• Remove the CC Tenders off of the exceptions in the Offline PMS Client.
• Re-test the Move Devices, ask the Property to check both Opera and the FreedomPay Portal.
• Remind the property that payments in Opera will show up after every 30 minutes.

In order to remove the CC Tenders off of the Offline PMS Client:

• Navigate to C:\Micros\Simphony\Custom\MF_PMS_IFC_Client
• Right Click on the MF_PMS_IFC_Client.xml and Edit

• Delete the Tender numbers that correspond to Credit Card Tenders in EMC, so that those numbers
are the only ones that are NOT within the exceptions.

83
BACK TO INDEX
V1.1 – Released 08/23/2023

REMOVE THESE TENDERS

• Save.
• Restart MF_PMS_IFC_Client_Service (can be found as either “Micros-Fidelio Offline PMS IFC
Service” or “Oracle FBGBU Offline PMS IFC Service”, depending on the version installed).

1 – Head to a workstation on a Revenue Center.


2 – Open a Check and copy the Check Number.
3 – Send it to the Move Device.
4 – On the Move Device, select the same RVC where it was created and have the property staff
swipe their Micros Card (or key in their employee number). It should be the same employee that
created the Check in the workstation.
5 – Select the check created using the Check Number copied.
6 – Process a payment through the Move Device with something cheap.
7 – Once the payment goes through, and does not appear in the workstation anymore (indicating
that the check has indeed been closed), then proceed with a full refund of that amount (create a
check with a negative amount).
8 – Ask property staff or Marriott POC to check the FreedomPay Portal to see if the transaction is
coming through.

If it is, then proceed with the remainder of the Move Devices.

84
BACK TO INDEX
V1.1 – Released 08/23/2023

Once they do, run the Offline PMS Client in order to force the transactions to go through Opera, and ask
the property POC to check Opera and see if they show up.

Before leaving the call, you must retrieve the following files for the completion email:
OPI.xml config – You can export this from OPI itself, rename it as [INNCODE]_OPI.xml
AntonioService.exe.config – You will find this file in C:/Program Files (x86)/FreedomPay/Antonio
MF_PMS_IFC_Client.xml – You will find this file in C:\Micros\Simphony\Custom\MF_PMS_IFC_Client in the
CAPS server. Make a copy as it will reflect the new CC Tenders.

After everything is working, answer any questions the property POC may have and report that the Cutover
has been complete.

This concludes the CUTOVER for Move Devices.

ANOMALIES AND TROUBLESHOOTING SCENARIOS


More than 8 RVCs
Due to a limitation within EMC, having more than 8 Revenue Centers implies changes in the
configuration of the following elements:

1. POS API Workstations (EMC Configuration).


2. Antonio Service Configuration.
3. OPI Configuration.

1. On EMC, the installer must create a new POS API workstation based off of another workstation
other than the CAPS. While all workstations should be able to process payments for it, ask the
property POC if there is a workstation that is guaranteed will be active while the property is open.

85
BACK TO INDEX
V1.1 – Released 08/23/2023

Once the POS API workstation has been created, we need to head to the Revenue Center tab, and make
sure that ONLY the Revenue Centers that were left out in the previous POS API are selected here. In the
example below, the property has 9 RVCs, so only the last one is selected as active for that POS API.

2. Antonio Service Configuration.

Within the AntonioService.exe.config, it is necessary to change which POS API it will have to connect to in
order to process the payments for that specific RVC. In order to do that, we need to add lines in
“opi.TSURI” so that it looks like this (example given with 9RVCs):

Here, the last RVC will be pointing at the new POS API (usually indicated by an IP Address) we have just
created. That way, whenever a transaction is done in that RVC, it will be processed in the indicated POS
API Workstation instead of the CAPS.

The rest of the Antonio Config file will reflect the amount of segments/RVCs as before (1 line for each).

86
BACK TO INDEX
V1.1 – Released 08/23/2023

• Save the changes within AntonioService.exe.config.

• Restart the Antonio Service.

3. OPI Configuration.

Within OPI, we must create a New Merchant that will contain the same basic information as the previous
one:

• Name
• City
• State or Province
• Country/Region
• Tenders Employee Number
• Users Employee Number
• Tables Employee Number

The only things that will be different are:

• StoreID (it can be any number)


• POS API
• Pay at Table Devices

87
BACK TO INDEX
V1.1 – Released 08/23/2023

• Enter the POS API website to validate there is communication between the POS API and OPI.

As it is the case, the RVC number must reflect the correct number within EMC and Antonio.

• Save the changes in OPI

• Restart the OPI Service.

88
BACK TO INDEX
V1.1 – Released 08/23/2023

Once everything is set up properly, each time a transaction is made in the 9th + RVC, it will trigger a
response from the second merchant we created, which points to the previously created POS API and allow
transactions.

Click here to get back to OPI CONFIGURATION.

More than 4 RVCs for UPP (Americas) Devices


UPP Move Devices have a limitation in the amount of RVCs that the devices can connect to at the same
time and can only display 4 Revenue Centers. While this limitation cannot be overcome, the installer must
inform of this limitation and provide alternatives on how to proceed.

A common practice is to assign RVCs 1,2,3 and 4 to Device 1, then RVCs 5,6,7 and 8 to Device 2. If that is
the case, then proceed with that. In the below example, there are 6 RVCs, so 1,2,3 and 4 were assigned to
Device 1, and 3,4,5 and 6 were assigned to Device 2.

There is however, a possibility that the property POC wants to have RVCs 1,3,5 and 9 to be run with a
specific Device.

If that is the case, the installer must indicate to the property POC which ports to connect to depending on
which RVCs they will be using. See the following example:

In this particular case, the Devices assigned to ports 7001 to 7008 will be assigned to RVCs 100 to 800,
and the Devices assigned to port 7009 will be assigned to RVCs 100, 300, 500 and 900.

Click here to go back to ANTONIO CONFIGURATION.

SA user and password not working


If the Property do not have the SQL credentials, then it will be necessary to create a temporary username
and password through CMD.

Take into account that running this script will temporarily shut down the CAPS ServiceHost (Simphony),
and the property POC needs to be warned about this.

• Open CMD as Administrator


• Run the following, line by line:
89
BACK TO INDEX
V1.1 – Released 08/23/2023

taskkill /IM Servicehost.exe /F


taskkill /IM Servicehost.exe /F
net stop MSSQL$SQLEXPRESS
net start MSSQL$SQLEXPRESS /m
sqlcmd -S .\SQLEXPRESS
alter login sa with password='Marriott18.2.2Now!' unlock
alter login datastoredb enable
Go
Exit
net stop MSSQL$SQLEXPRESS
net start MSSQL$SQLEXPRESS
After running this script, you should be able to log into QueryExPlus or run the PMS installer using SA and
Marriott18.2.2Now!

Click here to go back to Simphony 19.1 and Below

Click here to go back to Simphony 19.2 and Above

MF_EAME credentials not working after using QueryExPlus


After creating the MF_EAME db account for use with QueryExPlus, and when trying to launch the
application in order to run the script, you get an error regarding MF_EAME, there may be an issue with the
password created.

In the case this happens, you will have to:

• Run Microsoft SQL Server Management Studio


• Go to Databases > Security > Logins > MF_EAME
Right Click > Properties

90
BACK TO INDEX
V1.1 – Released 08/23/2023

On the General tab:

• Replace the Password for “MF_EAME” and confirm it with the same password.

You should now be able to log back into QueryExPlus with the MF_EAME db credentials.

Click here to go back to Simphony 19.1 and Below

Click here to go back to Simphony 19.2 and Above

OPI is not properly installing


After installing MySQL, but OPI is not being installed, and the correct version of Java is installed, then there
is a possibility that MySQL is not running under the correct timezone. If that is the case, the installer will
need to change the timezone manually.

• Go to C:/Programdata/mySQL and edit the my.ini file.

Within it, go to the Server Section, and under it, add the following lines:

#Set default time zone


default-time-zone = ‘xx:xx’

XX:XX being the time zone corresponding to the region the property is in. Once that is done, restarting the
mySQL service and trying again should work.

Click here to go back to OPI Installation.