You are on page 1of 6

1.

2 Motor Driven Metering Pump Sigma/ 1

Sigma Basic Type (S1Ba)


S1Ba Drive type
H Main drive, diaphragm
Pump type
bar l/h
12017 12 17
12035 12 35
10050 10 50
1 10022
10044
10
10
22
44
07065 7 65
07042 7 42
04084 4 84
04120 4 120
Material of liquid end
PV PVDF (max. 10 bar)
SS Stainless steel
Seal material
T PTFE seal
Diaphragm
S Multi-layer safety diaphragm with visual rupture indicator
A Multi-layer safety diaphragm with rupture signalling (contact)
Liquid end version
0 No spring
1 With 2 valve springs, Hastelloy C, 0.1 bar
4** With pressure relief valve, FKM seal, no valve spring
5** With pressure relief valve, FKM seal with valve springs
6** With pressure relief valve, EPDM seal, without valve spring
7** With pressure relief valve, EPDM seal, with valve spring
Hydraulic connection
0 Standard
1 Union nut and PVC insert
2 Union nut and PP insert
3 Union nut and PVDF insert
4 Union nut and SS insert
7 Union nut and PVDF hose nozzle
8 Union nut and SS hose nozzle
9 Union nut and stainless steel hose nozzle
Version
0 With ProMinent® logo (standard)
1 Without ProMinent® logo
M Modified
F with physiological safety (FDA) in respect of wetted materials
5 Left liquid end
Electrical power supply
S 3 ph, 230 V/400 V 50/60 Hz, 0.09 kW
T 3 ph, 230 V/400 V 50/60 Hz, with PTC
R Variable speed motor 3 ph, 230/400 V, with PTC, with external fan 1 ph 230 V 50/60 Hz
V (0) Variable speed motor with integrated frequency converter 1 pH, 230 V, 50/60 Hz
Z Speed control compl 1 ph 230 V, 50/60 Hz (variable speed motor + FC)
M 1 ph, AC, 230 V/50/60 Hz, 0.09 kW
N 1 ph, AC 115 V 60 Hz, 0.09 kW
L 3 ph, 230 V/400 V, 50 Hz, (Exe, Exd)
P 3 ph, 265 V/440 V, 60 Hz, (Exe, Exd)
2 No motor, C 42 flange (NEMA)
3 No motor, B 5, size 56 (DIN)
Enclosure rating
0 IP 55 (standard)
Motor Driven Metering Pumps

1 Exe motor version ATEX-T3


2 Exd motor version ATEX-T4
Stroke sensor
0 No stroke sensor (standard)
2 Pacing relay (reed relay)
3 Stroke sensor (Namur) for hazardous locations
Stroke length adjustment
0 Manual (standard)
1 With stroke positioning motor, 230 V/50/60 Hz
2 With stroke positioning motor, 115 V/60 Hz
3 With stroke control motor, 0...20 mA 230 V/50/60 Hz
4 With stroke control motor 4...20 mA 230 V/50/60 Hz
5 With stroke control motor 0...20 mA 115 V/60 Hz
6 With stroke control motor 4...20 mA 115 V/60 Hz

* 10 bar for PVDF version.


** As standard with tube nozzle in the bypass. Threaded connection on request.
EHEDG-certified (European Hygienic Eng. Design Group) type EL class 1 stainless steel dosing heads are
available on request.

1-10 Product Catalogue 2014 1.1.2014


1.2 Motor Driven Metering Pump Sigma/ 1

1.2.1 Sigma/ 1 Basic Type (S1Ba)

The Sigma/ 1 basic type is a motor-driven metering pump without internal electronics. The pump offers a
variety of different drive variations, whether fitted with the standard three phase motor or the single phase
AC motor. We also supply metering pumps with ATEX certification for use in EXe and EXde zones.
Different flange versions are available at any time and allow customers to use their own motors to drive the
1 pumps.

Sigma Basic Type Control Functions (S1Ba)


Stroke length actuator/controller
Actuator for automatic stroke length adjustment, actuating period approx. 1 sec for 1 % stroke length,
1 k Ohm response signal potentiometer, enclosure rating IP 54.
Controller consists of actuator with servomotor and integrated servo control for stroke length adjustment
via a standard signal. Standard signal input 0/4-20 mA corresponds to stroke length 0 - 100 %. Automatic/
manual operation selection key for manual stroke adjustment. Mechanical status display of actual stroke
length value output 0/4-20 mA for remote display.

Variable speed motors with integrated frequency converter (identity code specification V)
Power supply 1ph 230 V, 50/60 Hz, 0.18 kW
Externally controllable with 0/4-20 mA (see Fig. pk_2_103).
Upon request externally controllable via PROFIBUS® DP

Speed controllers with frequency converter (identity code specification Z)


The speed controller assembly consists of a frequency converter and a variable speed motor of 0.09 kW
pk_2_103

"Physiologically safe (FDA) in respect of wetted materials" version.


All wetted materials in the "Physiologically safe (FDA) in respect of wetted materials" version as per the
FDA guideline.
FDA guidelines:

K Material PTFE: FDA No. 21 CFR § 177.1550


K Material PVDF: FDA No. 21 CFR § 177.2510

Available for material version PVT and SST.


Identity code example: S1BaH04084PVTS00 F S000

Sigma / 1 Basic Type version "left liquid end "


This version offers additional adaptability to special installation situations, e.g. in combination with storage
tanks, brackets, etc.
Motor Driven Metering Pumps

Identity code example: S1BaH07042PVTS00 5 S000

P_SI_0152_SW

1-8 Product Catalogue 2014 1.1.2014


1.2 Motor Driven Metering Pump Sigma/ 1

Technical Data
Type S1Ba With 1500 rpm motor at 50 Hz With 1800 rpm motor at 60 Hz Suc- Perm. Connection, Shipping
tion pre-pres- suction/dis- weight
Delivery rate at Max. Delivery rate at max. Max. lift sure suc- charge side
max. back pressure stroke back pressure stroke rate tion side
rate
bar l/h ml/ Strokes/ psi l/h / gph (US) Strokes/ mWC bar G–DN kg
stroke min min 1
12017 PVT 10 17 3.8 73 174 20.4/5.3 88 7 1 3/4–10 9
12017 SST 12 17 3.8 73 174 20.4/5.3 88 7 1 3/4–10 12
12035 PVT 10 35 4.0 143 174 42.0/11.0 172 7 1 3/4–10 9
12035 SST 12 35 4.0 143 174 42.0/11.0 172 7 1 3/4–10 12
10050 PVT 10 50 4.0 205 145 60.0/15.8 246 7 1 3/4–10 9
10050 SST 10 50 4.0 205 145 60.0/15.8 246 7 1 3/4–10 12
10022 PVT 10 22 5.0 73 145 26.4/6.9 88 6 1 3/4–10 9
10022 SST 10 22 5.0 73 145 26.4/6.9 88 6 1 3/4–10 12
10044 PVT 10 44 5.1 143 145 52.8/13.9 172 6 1 3/4–10 9
10044 SST 10 44 5.1 143 145 52.8/13.9 172 6 1 3/4–10 12
07065 PVT 7 65 5.2 205 102 78.0/20.6 246 6 1 3/4–10 9
07065 SST 7 65 5.2 205 102 78.0/20.6 246 6 1 3/4–10 12
07042 PVT 7 42 9.5 73 102 50.4/13.3 88 3 1 1–15 10
07042 SST 7 42 9.5 73 102 50.4/13.3 88 3 1 1–15 14
04084 PVT 4 84 9.7 143 58 100.8/26.6 172 3 1 1–15 10
04084 SST 4 84 9.7 143 58 100.8/26.6 172 3 1 1–15 14
04120 PVT 4 120 9.7 205 58 144.0/38.0 246 3 1 1–15 10
04120 SST 4 120 9.7 205 58 144.0/38.0 246 3 1 1–15 14

Materials in contact with the medium


Material Dosing head Suction/pressure Seals/ball seat Balls Integral relief valve
connector
PVT PVDF PVDF PTFE/PTFE Ceramic PVDF/FKM or EPDM
SST Stainless steel 1.4404 Stainless steel 1.4581 PTFE/PTFE Stainless steel 1.4404 Stainless steel/FKM or EPDM

In version "F" the ball seat is made of PVDF

Motor Data
Identity code Power supply ǎ/Y Remarks
specification
S 3 ph, IP 55 220-240 V/380-420 V 50 Hz 0.09 kW
265-280 V/440-480 V 60 Hz 0.09 kW
T 3 ph, IP 55 220-240 V/380-420 V 50 Hz 0.09 kW with PTC, speed adjustment range 1:5
265-280 V/440-480 V 60 Hz 0.09 kW
R 3 ph, IP 55 220-240 V/380-420 V 50 Hz 0.09 kW with PTC, speed adjustment range 1:20
with external fan 1ph 230 V; 50/60Hz
V0 1 ph, IP 55 230 V ±10 % 50/60 Hz 0.18 kW Variable speed motor with integrated
frequency converter control range 1:20
Motor Driven Metering Pumps

M 1 ph AC, IP 55 230 V ±5% 50/60 Hz 0.12 kW


N 1 ph AC, IP 55 115 V ±5 % 60 Hz 0.12 kW
L1 3 ph, II2GEExellT3 220-240 V/380-420 V 50 Hz 0.12 kW
L2 3 ph, II2GEExdllCT4 220-240 V/380-420 V 50 Hz 0.18 kW with PTC, speed adjustment range 1:5
P1 3 ph, II2GEExellT3 250-280 V/440-480 V 60 Hz 0.12 kW
P2 3 ph, II2GEExdllCT4 250-280 V/440-480 V 60 Hz 0.18 kW with PTC, speed adjustment range 1:5

Motor data sheets can be requested for more information.


Special motors or special motor flanges are available on request.
Motors less than 0.75 kW and motors designed for speed-controllable operation are not subject to the IEC2
standard in compliance with the Ecodesign Directive 2005/32/EC.
Note concerning installation in Ex-zones:
With effect from 01.07.2003, only pumps with a suitable identification and rating plate in accordance with
ATEX Directive 94/9/EC should be used in areas with potentially explosive atmospheres. The explosion
group, category and degree of protection stated on the rating plate should correspond to, or be higher than,
the conditions specified in the intended application.

1.1.2014 Product Catalogue 2014 1-9


1.3 Motor Driven Metering Pump Sigma/ 2

Sigma Basic Type (S2Ba)


S2Ba Drive type
HM Main drive, diaphragm
Pump type
bar l/h
16050 16 47
16090 16 82

1 16130 16
07120 7
124
126
07220 7 220
04350 4 350
Liquid end material
PV PVDF (max. 10 bar)
SS Stainless steel
Seal material
T PTFE seal
Diaphragm
S Multi-layer safety diaphragm with visual rupture indicator
A Multi-layer safety diaphragm with rupture signalling (contact)
Liquid end version
0 No spring
1 With 2 valve springs, Hastelloy C4, 0.1 bar
4** With pressure relief valve, FKM seal, no valve spring
5** With pressure relief valve, FKM seal with valve springs
6** With pressure relief valve, EPDM seal, without valve spring
7** With pressure relief valve, EPDM seal, with valve spring
Hydraulic connection
0 Standard
1 Union nut and PVC insert
2 Union nut and PP insert
3 Union nut and PVDF insert
4 Union nut and SS insert
7 Union nut and PVDF hose nozzle
8 Union nut and SS hose nozzle
9 Union nut and stainless steel hose nozzle
Version
0 With ProMinent® logo (standard)
1 Without ProMinent® logo
M Modified
F with physiological safety (FDA) in respect of wetted materials
Electrical power supply
S 3 ph, 230 V/400 V 50/60 Hz
T 3 ph, 230 V/400 V 50/60 Hz, with PTC
R Variable speed motor 3 ph, 230/400 V, with PTC, with external fan 1 ph 230 V 50/60 Hz
V (0) Variable speed motor with integrated frequency converter 1 pH, 230 V, 50/60 Hz
Z Speed control compl 1 ph 230 V, 50/60 Hz (variable speed motor + FC)
M 1 ph, AC, 230 V/50/60 Hz
N 1 ph, AC, 115 V, 60 Hz
L 3 ph, 230 V/400 V, 50 Hz, (Exe, Exd)
P 3 ph, 265 V/440 V, 60 Hz, (Exe, Exd)
1 No motor, with B14 flange, Gr. 71 DIN
2 No motor, with flange NEMA 56 C
3 No motor, with B5 flange, Gr. 63 DIN
Enclosure rating
0 IP 55 (standard)
1 Exe motor version ATEX-T3
2 Exd motor version ATEX-T4
Motor Driven Metering Pumps

Stroke sensor
0 No stroke sensor (standard)
2 Pacing relay (reed relay)
3 Stroke sensor (Namur) for hazardous locations
Stroke length adjustment
0 Manual (standard)
1 With stroke positioning motor, 230 V/50/60 Hz
2 With stroke positioning motor, 115 V/50/60 Hz
3 With stroke control motor, 0...20 mA 230 V/50/60 Hz
4 With stroke control motor, 4...20 mA 230 V/50/60 Hz
5 With stroke control motor, 0...20 mA 115 V/50/60 Hz
6 With stroke control motor, 4...20 mA 115 V/50/60 Hz

* 10 bar for PVDF version.


** As standard with tube nozzle in the bypass. Threaded connection on request.
EHEDG-certified (European Hygienic Eng. Design Group) type EL class 1 stainless steel dosing heads are
available on request.

1-22 Product Catalogue 2014 1.1.2014


1.3 Motor Driven Metering Pump Sigma/ 2

1.3.1 Sigma/ 2 Basic Type (S2Ba)

The Sigma/ 2 basic type is a motor-driven metering pump without internal electronics. The pump offers a
variety of different drive variations, whether the standard three phase motor or the single phase AC motor.
We also supply metering pumps with ATEX-certification for use in EXe and EXde zones.
Different flange versions are available at any time and allow customers to use their own motors to drive the
1 pumps.

Sigma Basic Type Control Functions (S2Ba)

Stroke length actuator/controller


Actuator for automatic stroke length adjustment, actuating period approx. 1 sec for 1 % stroke length,
1 k Ohm response signal potentiometer, enclosure rating IP 54.
Controller consists of actuator with servomotor and integrated servo control for stroke length adjustment
via a standard signal. Standard signal input 0/4-20 mA corresponds to stroke length 0 - 100 %. Automatic/
manual operation selection key for manual stroke adjustment. Mechanical status display of actual stroke
length value output 0/4-20 mA for remote display.

Variable speed motors with integrated frequency converter (identity code specification V)
Power supply 1ph 230 V, 50/60 Hz, 0.37 kW
Externally controllable with 0/4-20 mA (see Fig. pk_2_103)
On request externally controllable via PROFIBUS® DP

pk_2_103
Speed controllers with frequency converter (identity code specification Z)
The speed controller assembly consists of a frequency converter and a variable speed motor of 0.37 kW.

"Physiologically safe (FDA) in respect of wetted materials" version.


All wetted materials in the "Physiologically safe (FDA) in respect of wetted materials" version comply with
the FDA guideline.
FDA guidelines:

K Material PTFE: FDA No. 21 CFR § 177.1550


K Material PVDF: FDA No. 21 CFR § 177.2510

Available for material version PVT and SST.


Identity code example: S2BaHM07220PVTS00 F S000
Motor Driven Metering Pumps

1-20 Product Catalogue 2014 1.1.2014


1.3 Motor Driven Metering Pump Sigma/ 2

Technical Data
Type With 1500 rpm motor at 50 Hz With 1800 rpm motor at 60 Hz Suction Perm. pre- Connection Shipping
S2Ba lift pressure suction/dis- weight
suction charge side
Delivery rate at max. Max. Delivery rate at Max. side
back pressure stroke max. back pressure stroke
rate rate
bar l/h ml/
stroke
Strokes/
min
psi l/h / gph (US) Strokes/
min
mWC bar G–DN kg 1
16050 PVT 10 50 11.4 73 145 60.0/15.8 87 7 3 1–15 15
16050 SST 16 47 11.4 73 232 56.0/14.7 87 7 3 1–15 20
16090 PVT 10 88 11.4 132 145 106.0/28.0 158 7 3 1–15 15
16090 SST 16 82 11.4 132 232 98.4/25.9 158 7 3 1–15 20
16130 PVT 10 135 10.9 198 145 156.0/41.2 238 7 3 1–15 15
16130 SST 16 124 10.9 198 232 148.0/39.0 238 7 3 1–15 20
07120 PVT 7 126 27.4 73 102 150.0/39.6 87 5 1 1 1/2–25* 16
07120 SST 7 126 27.4 73 102 150.0/39.6 87 5 1 1 1/2–25* 24
07220 PVT 7 220 27.7 132 102 264.0/69.7 158 5 1 1 1/2–25* 16
07220 SST 7 220 27.7 132 102 264.0/69.7 158 5 1 1 1/2–25* 24
04350 PVT 4 350 29.4 198 58 420.0/110.9 238 5 1 1 1/2–25* 16
04350 SST 4 350 29.4 198 58 420.0/110.9 238 5 1 1 1/2–25* 24

* With Sigma types 07120, 07220 and 04350, the dosing head is fitted with DN 25 (G 1 1/2) valves. As DN 20 is generally sufficient for these
types of pipes (see technical data, suction/discharge side connector), the connector parts that can be ordered under the identity code
(e.g. inserts) are already reduced to DN 20, i.e. piping and accessories can be installed in DN 20.

Materials in contact with the medium


Material Liquid end Suction/discharge Seals/ Balls Integrated overflow valve
connector ball seat
PVT PVDF PVDF PTFE/PTFE Ceramic/glass * PVDF/FKM or EPDM
SST Stainless steel 1.4404 Stainless steel 1.4581 PTFE/PTFE Stainless steel 1.4404 Stainless steel/FKM or EPDM

* for 07120, 07220, 04350


In version "F" the ball seat is made of PVDF

Motor Data
Identity code Power supply ǎ/Y Remarks
specification
S 3 ph, IP 55 220-240 V/380-420 V 50 Hz 0.25 kW
265-280 V/440-480 V 60 Hz 0.25 kW
T 3 ph, IP 55 220-240 V/380-420 V 50 Hz 0.25 kW with PTC, speed adjustment range 1:5
265-280 V/440-480 V 60 Hz
R 3 ph, IP 55 220-240 V/380-420 V 50 Hz 0.37 kW with PTC, speed adjustment range 1:20 with
external fan 1ph 230 V; 50/60Hz
V0 1 ph, IP 55 230 V ±5 % 50/60 Hz 0.37 kW Variable speed motor with integrated
frequency converter control range 1:20
Motor Driven Metering Pumps

M 1 ph AC, IP 55 230 V ±5% 50/60 Hz 0.18 kW


N 1 ph AC, IP 55 115 V ±5 % 60 Hz 0.18 kW
L1 3 ph, II2GEExellT4 220-240 V/380-420 V 50 Hz 0.18 kW
L2 3 ph, II2GEExdllCT4 220-240 V/380-420 V 50 Hz 0.18 kW with PTC, speed adjustment range 1:5
P1 3 ph, II2GEExellT3 250-280 V/440-480 V 60 Hz 0.18 kW
P2 3 ph, II2GEExdllCT4 250-280 V/440-480 V 60 Hz 0.21 kW with PTC, speed adjustment range 1:5

Motor data sheets can be requested for more information.


Special motors or special motor flanges are available on request.
Motors less than 0.75 kW and motors designed for speed-controllable operation are not subject to the IEC2
standard in compliance with the Ecodesign Directive 2005/32/EC.
Note concerning installation in Ex-zones:
With effect from 01.07.2003, only pumps with a suitable identification and rating plate in accordance with
ATEX Directive 94/9/EC should be used in areas with potentially explosive atmospheres. The explosion
group, category and degree of protection stated on the rating plate should correspond to, or be higher than,
the conditions specified in the intended application.

1.1.2014 Product Catalogue 2014 1-21