Horizontal Vessel Slope Requirment


Saeid Rahimi Mofrad Top Contributors in this Group
Senior Specialty Process Engineer at Fluor
Top Contributor

Can anybody advise a value for sople of horizontal vessel.


I have seen different values from 1:100 to 1:500.
Saeid Rahimi Mofrad
Is there any criteria for selecting slope? Senior Specialty Process Engineer at Fluor

See all members 

Like Comment (4) Share Unfollow April 14, 2011 Business Service
Your group contribution level
Add to Manager's Choice Close Discussion
Congrats! Regularly add great discussions and
comments to stay a Top Contributor.
Comments

 4 comments

Top Contributor
Alireza Rashidkhani
Senior Process Engineer at Aker Solutions

What I have seen is 1:100 but beware of corrosion at the end of the slope due to stagnant liquid
Alireza exposure.
Like Reply privately Delete April 14, 2011

Deepak Goyal (AMIChemE)


Senior Process Engineer at Technip

One of company guideline suggest to slope horizontal vessels 1 inch in


Deepak 10 feet down towards the outlet or low point drain so that the vessel
may be completely drained during shutdown. This slope is equivalent to
a slope of 1:120.

In my view minimum slope should be around 1;200 .


1: 500 is too low for a vessel becaus this cant ensure gravity draining specially if liquid is viscous
and having sand etc .
Latest Activity
Thanks
Like Reply privately Delete April 16, 2011 Dattatray Kolte likes a discussion in
Chemwork. Mojtaba Habibi
Lesson Learned
Saeid Rahimi Mofrad Hysys/UniSim Dynamic
Senior Specialty Process Engineer at Fluor Depressuring Utility: Heater
Top Contributor Type Dears, For dynamic depressuring
utility 2 options are available for heater
Is there any other consideration in determining slope? type which are liquid heater (default
option) and vessel heater. This can be
accessed via: PFD of the depressuring
is tank slope different from horizontal vessel? utility... more
is there any length consideration? for example somebody told me that slope is not required if 43m ago
vessel length is lower than 4.0m. Is slope of 10m long vessel is same as 30m?
what about the effect of slope on liquid level measurement, alarm and trip of long vessel. 1:100 Saeid Rahimi Mofrad commented on
slope results in 200mm elevation difference between two ends of 20m long vessel. a discussion in Chemwork.
is slope of flare KOD is same as production separator? any difference between above ground and Febriyan Nizfa Saputra How
underground horizontal vessels? to Size Gas Filter Dear
Respectable Member, In one
what about the effect of vessel content's properties (viscosity, sand,etc)? of my ongoing project the owner ask
what if there is a vertical column/vessel on top of horizontal vessel (like amine flash drum)? can me to size Gas Filter for Natural Gas. It
high slope impede proper operation of column (liquid distribution, etc)? is used to remove solid particle
passed in gas flow. I have search in
Google but I cant... more
Regards
14h ago
Saeid Nasim Khanmirzaei started a
discussion in Chemwork. Heat
Delete April 22, 2011
Tracing/ Winterization Dears; It would
be highly appreciated if you could
share any criteria and references for
Saeid Rahimi Mofrad Winterization type selection (steam or
Senior Specialty Process Engineer at Fluor electrical).
Top Contributor 17h ago

I got some feedback from my friends: See all activity


- For storage tanks designed as per API-650, the furnished tank grade shall be sloped towards
sump at a slope of 1:120 unless otherwise specified by the Owner.
- For horizontal vessels with boot, slope of 1:100 to 1:200 (for vessel longer than 10m) has been About Feedback Privacy & Terms
proposed. Slope less than 1:200 is not normally used.
LinkedIn Corp. © 2014
- For other cases, no slope is practically required.

Regards
Saeid
Delete July 28, 2011