You are on page 1of 1

MEMENTO

A) FIND THE REVERBERATION VIVERE

TIME MANAV B. JOSHI


1800701040

FOR A CLASSROOM
FOURTH YR. BARCH.

45ft X 36ft X 13ft (height)


NORTH

WHICH HAS PLASTERED WALLS, GEO LOCATION:


TYPICAL PLAN:

HARD PLASTER ON THE CEILING


AND WOODEN FLOORING
1. VOLUME OF THE ROOM

45 X 36 X 13 (ft)
=21060 (cubic ft)

2. We use the metric Reverberation Time 60 (RT60).


RT60 is defined as the measure of the time after the
sound source ceases that it takes for the sound pressure SOUND ABSORPTION COEFFICIENT DATA SPECIFIC AREAS
level to reduce by 60 dB.

3. RT60 = 0.05 V/a


RT60 = Reverberation Time
V = volume of the space (feet cubed) 6. RT60 = 0.05 X V/ a1xa2xa3 PROJECT NAME:

REVERBERATION TIME SHEET


a = sabins (total room absorption at given frequency)
RT60 = 0.05 X 21060 / (610.74 + 32.4 + 162)
STUDENT NAME :

MANAV B. JOSHI
4. sabins = Surface area of Material X coefficient of absorption
PROFESSOR / MENTOR :

5. sabins calculation RT60 = 1053 / 805.14 PLAN TYPE:

45

WALLS TOTAL SHEETS: PLAN NUMBER:

SA of walls (plaster) = (45 X 13 X 2) + (36 X 13 X 2) = 2106 ft2 RT60 = 1.3078 seconds 06

a1 = 2106 x 0.29 (plaster coefficient) = 610.74 SUBJECT:

BUILDING SERVICES

13
CEILING
SA of ceiling (hard plaster) = (45 X 36 ) = 1620 ft2 PLEASE NOTE THAT
a2 = 1620 x 0.02 (hard plaster coefficient) = 32.4 ALL DIMENSIONS ARE SEMESTER VII
36
IN FEET AND SECONDS SCALE
1:100
SIGN

FLOOR ANNOTATION

SA of floor (wood flooring) = (45 X 36 ) = 1620 ft2 METERS

a3 = 1620 x 0.1 (wooden flooring coefficient) = 162 ISOMETERIC VIEW OF ROOM DATE

10/10/23